PLUS 2.0 Bottle Contain Built in Lithium Battery
“
Product Information
Specifications:
- Rated Voltage: 5V
- Battery Volume: 2200mAh
- Capacity: 250ml
- H2 Production: 5 min = +/- 3.0ppm, 10 min = +/- 6.0ppm
- H2 Purity: +/- 99.9%
- Size: 61*55*210mm
- Net Weight: 335g
- Accessories: Type C USB charging cable
Product Usage Instructions:
Water:
Type: We recommend using filtered, purified, or
distilled water to maintain the integrity of the electrolysis
plates. Tap water can be used, but it may compromise the bottle’s
lifespan depending on the water quality.
Cleaning:
- Use the cleaning program once per week by pressing the On/Off
Switch for 3 seconds to start the automatic 3-minute backwash
program. - To manually clean, fill the bottle half full with warm water
& white vinegar, shake, let stand for 15 minutes, and rinse
before next use. Clean every 2 weeks.
Storage:
Keep the product in a cool, dry place out of direct sunlight.
Keep the membrane moist and rinse before next use.
Charging:
- Use the provided USB cable to charge the bottle.
- A red light indicates charging, while a green light indicates a
full charge. - Do not leave the bottle connected to a power source after the
battery is fully charged.
Touch Screen Interface:
- Tap the screen gently to activate touch screen options.
- Select desired options by tapping the icons on the screen.
- Slide the screen from left to right or right to left to turn
pages. - Access settings by tapping the Settings icon for further menu
options.
FAQ:
Q: Can tap water be used with this product?
A: Yes, tap water can be used, but it is recommended to use
filtered, purified, or distilled water for better performance and
longevity of the product.
Q: How often should I clean the bottle?
A: It is recommended to use the cleaning program once per week
and manually clean with warm water & white vinegar every two
weeks.
“`
H2ULTRA PLUS 2.0
Product Informa.on
Rated Voltage: Ba6ery Volume: Capacity: H2 Produc.on:
H2 Purity: Size: Net Weight: Accessories:
5VOIA 2200mAh 250ml 5 min = +/- 3.0ppm 10 min = +/- 6.0ppm +/- 99.9% 61*55*210mm 335g Type C USB charging cable
Website:
h2ultra.eu
Opera.ng Instruc.ons 1. Fill the boQle with water. Screw on the cap using the indicated arrows on both the cap and boQle body. 2. Press the On/Off Switch once to start the 5 minute hydrogen producTon program. The LED display will show Tme remaining on the program and beep when the program is complete. 3. Press the On/Off Switch twice in quick succession to start the 10 minute hydrogen producTon program. The LED display will show Tme remaining on the program and beep when the program is complete. 4. For best results drink the Hydrogen enriched water within 5 minutes of program compleTon.
Prior to First Use 1. Prior to first use rinse the inside of the boQle with warm clean water. Discard the used water. 2. Once cleaned fill the boQle with water and iniTate a 5 minute program by pressing the On/Off Switch once. When the program is finished, open the top and discard the water. 3. The baQery comes parTally charged. We recommend fully charging the baQery using the USB charging cable. A red constant light will indicate charging mode. A Green constant light will show the boQle is fully charged.
Water Type 1. We recommended filtered, purified or disTlled water to maintain the integrity of the electrolysis plates. 2. It is possible to use tap water. The boQle does have the ability to filter out chlorine but the life of the boQle may be compromised depending on the quality and amount of chemicals in the tap water.
Cleaning 1. We recommend using the cleaning program once per week. 2. Press the On/Off Switch for 3 seconds to start the automaTc 3 minute backwash program. 3. The boQle may also be cleaning using warm water & white vinegar. Fill the boQle half full with warm water & white vinegar. Shake and let stand for 15 minutes. Rinse before next use. Clean every 2 weeks.
Storage 1. Keep in a cool dry place out of direct sunlight. Keep membrane moist and rinse before next use.
Charging 1. Use USB cable to charge boQle. 2. A red light will be displayed when charging. A green light will indicate a full charge. 3. Do not leave boQle connected to power source aber baQery is fully charged.
Precau.ons / Warnings 1. Read instrucTons carefully before use. 2. Do not disassemble or aQempt to modify the boQle. 3. Do not place or store near heat / stove / open flame. 4. Do not place in a microwave oven. 5. Do not freeze or use frozen water. 6. Do not use juices, milk, alcohol, beer, salt water, tea or other liquid in the boQle. 7. Suitable air temperature 0°C 50°C. Suitable water temperature 0°C 50°C. 8. Do not use chemicals or soap to clean the boQle. 9. Do not charge the water more than the maximum 10 minute program. Overcharging the water will result in excess pressure and risk the boQle cracking or splijng. 10. Do not aQempt to open the boQle during hydrogen producTon. First turn off the hydrogen program by pressing the On/Off switch. 11. Do not immerse the boQle in water or other substance. Do not place in the dishwasher. If you want to clean the outside of the boQle it must be done manually with a damp cloth. 12. Immersing the boQle in water or other cleaning substance will damage the built-in baQery.
Touch Screen Interface
1. Tap the screen gently to acTvate the touch screen opTons. 2. Tap the icon on the screen to select the desired opTon. 3. Slide the screen from “leb to right” or “right to leb” to turn the page. 4. Tap the “Sejngs” icon to enter the second-level menu and tap again to
enter the third-level menu.
Coloured Blue
Light
Light
ON
OFF
ON
OFF
Factory Sejng in English Language
Cleaning
H2 GeneraTng
Charging
Documents / Resources
![]() |
H2Ultra PLUS 2.0 Bottle Contain Built in Lithium Battery [pdf] Instruction Manual PLUS 2.0 Bottle Contain Built in Lithium Battery, PLUS 2.0, Bottle Contain Built in Lithium Battery, Contain Built in Lithium Battery, Built in Lithium Battery, Lithium Battery, Battery |