GYS 73502 Smart Hub Module
Product Information
Specifications:
- Product Name: SMART HUB MODULE
- Model Number: 73502 V1
- Date: 23/01/2024
- Manufacturer Website: www.gys.fr
Product Usage Instructions
Installation:
To install the SMART HUB MODULE, follow these steps:
- Connect a GYSFLASH CNT charger to channel 1 using the supplied SMC cable.
- Ensure the device is connected to a single-phase 230 V (50 – 60 Hz) three-wire electrical installation with an earth.
- If using in a Multi-Charger configuration, connect the module to the same channel as a Gysflash without connecting the mains lead.
- Verify that the LED corresponding to the module’s channel is illuminated to confirm activation.
Usage:
To use the SMART HUB MODULE, follow these guidelines:
- The module must be connected to a Gysflash on the same channel to draw power.
- For Multi-Charger configuration, no mains lead connection is required for the SHM device.
Maintenance:
For maintenance, ensure that the machine is connected to an earthed socket and follow the manufacturer’s maintenance instructions provided in the manual.
FAQ
- How many modules can be connected to a single Gysflash CNT charger using the SHM device?
The Smart Hub Module allows a maximum of 4 modules to be connected to a single Gysflash CNT charger. - What should I do if I encounter error codes like Err27, Err28, Err31, or Err32?
Refer to the troubleshooting section in the manual for specific error code details and recommended actions to resolve them.
SAFETY INSTRUCTIONS
- This user manual includes operation instructions, and the safety precautions to be followed by the user. Please read it carefully before first use and keep it for future reference. These instructions must be read and fully understood before use. Do not carry out any alterations or maintenance work that is not directly specified in this manual. The manufacturer shall not be liable for any damage to persons or property resulting from use not in accordance with the instructions in this manual. If you have any problems or queries, please consult a qualified person to correctly operate the equipment. This device may only be used for ticket printing and/or data transmission within the limits indicated on the device and manual. The safety instructions must be followed. The manufacturer cannot be held responsible in the event of improper or dangerous use.
- The device is designed to be used indoors. Must not be exposed to the rain.
- Do not use the charger if the mains cable or plug is damaged.
- Do not place the unit near a heat source, direct sunlight or continuously high temperatures (above 50 °C).
- This machine must be connected to an earthed socket.
Maintenance
- Maintenance should only be carried out by a qualified person.
- Warning! Always disconnect from the mains before carrying out maintenance on this machine.
- Never use solvents or other aggressive cleaning agents.
- Clean the surfaces of the unit with a dry cloth.
Regulations:
- Equipment complies with European directives
- The Declaration of Conformity is available on our website.
- The Eurasian Economic Community (EAEC) mark of conformity.
- This equipment conforms to UK requirements.
- The UK Declaration of Conformity is available on our website (see cover page).
- This device complies with Moroccan standards.
- The C م (CMIM) declaration of conformity is available on our website.
Disposal:
This machine is subject to selective collection. Do not dispose of in domestic waste.
PRODUCT OVERVIEW
- SMC output for CNT Module (x4)
- SMC input for GYSFLASH CNT (x4)
- 230 Vac power cable socket
- SMC cord
- Power supply cable
CHANNEL NUMBERS
MULTI-MODULE CONFIGURATION
The Smart Hub Module (SHM) is an accessory that allows several modules (maximum 4) to be connected to a single Gysflash CNT charger.
Set up
For the SHM device to work, a GYSFLASH CNT charger must be connected to channel 1 (FIG II) via the SMC cable supplied.
Can be used with or without power cable
- This device is supplied with a 16 A CEE7/7 plug and must only be used in a single-phase 230 V (50 – 60 Hz) three-wire electrical installation that includes an earth.
- If there are as many (or more) chargers as there are modules connected to the SHM, then a mains supply is not required. Each Gysflash can supply power to the module connected to its respective channel.
- To draw power from a charger, the module must be connected to the same channel as a Gysflash.
- In Multi-Charger configuration, it is not necessary to connect the SHM mains lead.
- If there are more modules than chargers connected to the SHM, it is necessary to connect the SHM’s mains cable in order to activate all the channels.
- To check that the channel corresponding to a module is activated, confirm that the associated LED is lit.
Usage
- Make sure that the Gysflash and the modules are properly connected to the SHM (see Installation section above).
- Switch on the Gysflash and, if necessary, connect the SHM to the mains power.
- Make sure that the LEDs corresponding to the different modules are illuminated.
- The Gysflash is now ready to be used in conjunction with the attached modules.
MULTI-CHARGER CONFIGURATION ̶ PARALLELIZATION (PARALLEL)
When identical Gysflash CNT chargers are connected in parallel, the SHM handles comunication between them in order to become an ultra-powerful charging system.
To use this function, the SHM must be combined with a Power Hub Module (PHM – ref. 056589) to manage the power.
Paralleling can only be done with identical GYSFLASH CNT units (maximum 4).
Master/Slave communication:
Gysflash CNT chargers are installed in parallel using a Master/Slave configuration. One Gysflash (the Master) controls all the others (the Slaves).
Set up
- Connecting the Gysflash to the SHM:
- Connect the Gysflash units you wish to run in parallel to a channel on the SHM. The Master Gysflash must be connected to channel 1 (FIG II).
- The Slave Gysflashes units can be connected to channels 2 , 3 , or 4 (FIG II).
Make sure that the Gysflash output cables are properly interconnected via the PHM. For more detail, refer to the PHM manual.
For Gysflash units manufactured before January 2024 (serial number less than 24.01.xxxxxx. xxxxxx), please refer to the «SHM supplementary leaflet» available on the website www.gys.fr for more details on the specific installation requirements for this version of charger.
- Gysflash configuration:
Turn on all the Gysflash units. For each Gysflash, open the Multi-charger menu (see Gysflash manual) and select the appropriate configuration: - Cable calibration
- On the Gysflash Master interface, go to the Cable calibration menu (see Gysflash manual).
- Cables can be calibrated either automatically (recommended) or manually (OLED screen only).
- This procedure is used to calibrate the charging cables of the unit, so that the Gysflash can compensate effectively for any drop in voltage caused by the cables.
Usage
- Switch on all Gysflash units
- Check that the Gysflash units are correctly connected to the SHM and PHM (Installation section).
- Use the Gysflash Master interface to control the multi-charger.
MULTI-CHARGER CONFIGURATION – EQUALIZATION (EQUALIZE)
The SHM manages communication between Gysflash CNT chargers, so that battery charge levels can be equalised.
Equalisation can only be carried out with identical Gysflash CNTs (maximum of 4).
Master/Slave communication:
Battery equalisation is performed using Gysflash CNT chargers in a Master/Slave configuration.
One Gysflash (the Master) controls all the others (the Slaves).
Set up
- Connecting the Gysflash to the SHM:
- Connect each Gysflash to a channel on the SHM.
- The Master Gysflash must be connected to channel 1 (FIG II).
- The Slave Gysflashes units can be connected to channels 2 , 3 , or 4 (FIG II).
For Gysflash units manufactured before January 2024 (serial number less than 24.01.xxxxxx. xxxxxx), please refer to the «SHM supplementary leaflet» available on the website www.gys.fr for more details on the specific installation requirements for this version of charger.
- Gysflash configuration:
Turn on all the Gysflash units. For each Gysflash, open the Multi-charger menu (see Gysflash manual) and select the appropriate configuration:
Usage
- Switch on all Gysflash units
- Check that the Gysflash units are correctly connected to the SHM (see Installation section).
- Use the Gysflash Master interface to control the multi-charger.
To ensure optimal equalisation, we recommend connecting the clamps of each charger directly to the terminals of each battery (without any intermediary cables).
TROUBLESHOOTING
Err27: Cable_NOK |
Multi-charger mode:
Parallel connection of charging cables failed |
Charging cables to be replaced. |
Poor connection, check assembly (PHM). | ||
Err28 : COM_NOK |
Multi-charger mode: Communication failure between chargers | No communication, check SHM assembly and SLAVE X charger configuration. |
Replace DB9 cable(s). | ||
Err31 : COM_NOK |
Multi-charger mode: Gysflash connected on the wrong SHM channel |
Check that the Master Gysflash is installed on channel 1 of the SHM, and that the Slave Gysflashes are installed on the other channels. |
To revert back to single-charger operation, press the START/STOP button, enter the administrator code, and select OFF for the Multi-charger function. | ||
Err32 : Unbalanced | Equalize mode:
Unbalanced batteries |
Ensure that none of the batteries are faulty. |
FIXING
There are two mounting options:
- to the wall (screws not supplied)
- on the Gysflash XL-ND trolley – ref. 028890 (use the screws supplied with the trolley).
WARRANTY
- The warranty covers all defects or manufacturing faults for a period of two years starting from the date of purchase (parts and labour).
- The warranty does not cover:
- Any other damage caused during transport.
- The general wear and tear of parts (i.e. : cables, clamps, etc.).
- Incidents caused by misuse (incorrect power supply, dropping or dismantling).
- Environment-related faults (such as pollution, rust and dust).
- In the event of a breakdown, please return the item to your distributor, along with:
- a dated proof of purchase (receipt or invoice etc.).
- a note explaining the malfunction.
SPARE PARTS
- Mains terminal block 52431
- Circuit board E0061C
- SMC connection cable 70988
- IEC C13 mains power cord IEC C13
TECHNICAL SPECIFICATIONS
- Reference SMART HUB MODULE
- Rated insulation voltage (Ui ) 250 VRMS
- Rated impulse withstand voltage (Uimp) 2.5 kV
- Protection rating IP40
- Weight (load cables not included) 1,07 kg
- Dimensions (L x H x D) 220 x 180 x 45 mm
- Standards
- EN 60335-1
- CEI EN 60529 (IP)
- EN 55014-1 (CEM)
- EN 55014-2 (CEM)
- EN 55058-1 (RoHS)