Goodman MBVB Variable Speed Modular Blower User Manual

Goodman-LOGO

Goodman MBVB Variable Speed Modular Blower

Goodman-MBVB-Variable-Speed-Modular-Blower-PRODUCT

Product Features

  • Variable-speed ECM blower motor
  • Integrated communicating ComfortBridge™ Technology
  • Commissioning and diagnostics via on-board Bluetooth with the CoolCloud™ phone and tablet application
  • Advanced configuration of the airflow and tonnage in communicating mode
  • Provides constant CFM over a wide range of static pressure conditions independent of duct system
  • CFM indicator
  • Fault recall of six most recent faults
  • Provides adjustable low CFM for efficient fan-only operation
  • Improved humidity and comfort control
  • Built-in compatibility with multi-stage heat pump and cooling applications
  • UL 60335 2-40 Compliant
  • AHRI certified; ETL listed

Cabinet Features

  • Blower section usable as electric heater
  • Horizontal or vertical configuration capabilities
  • 21” depth for easier attic access
  • Foil-faced insulation covers the internal casing to reduce cabinet condensation
  • Galvanized, leather grain-embossed finish
  • Cabinet air leakage less than 2% at 1.0 inch H₂0 when tested in accordance with ASHRE standard 193
  • Cabinet air leakage less than 1.4% at 0.5 inch H₂0 when tested in accordance with ASHRE standard 193
  • Field-installed 3 kW – 20 kW electric heater kits available

Nomenclature

Goodman-MBVB-Variable-Speed-Modular-Blower-FIG-1

Product Specifications

Model MBVB12BP1X00 MBVB16CP1X00 MBVB20DP1X00
Blower
Diameter 10″ 10″ 11″
Width 8″ 8″ 10″
Electrical Data
Voltage (V) 208/230 208/230 208/230
MCA (A) 4.9 6.5 6.5
MOP (A) 15
Blower Motor Power (HP) ½ ¾ ¾
Dimensions
Width 17½” 21″ 24½”
Depth 21″ 21″ 21″
Height 26″ 30″ 30″
Ship Weight (Lbs.) 67 80 86
  • Minimum Circuit Ampacity and Maximum Overcurrent Protection Device (MOD) for blower without supplemental heat installed. Refer to unit nameplate for these specifications with approved accessory heaters installed.
  • Condensate management kits are available for units installed in high temperature and high humidity areas.
  • Kit number MBK0002 has been developed to resolve condensate issues in the field and is available from the Service Parts Department. Refer to IO-849 for installation instructions.

Airflow Data

Model Speed Tap Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
MBVB12

BP1X00A*

A B C D Low Low Low

Low

420

550

680

810

415

545

675

805

400

540

670

800

400

540

665

800

395

535

660

800

390

530

655

795

390

530

655

790

390

525

650

785

380

520

640

785

A B C D High High High

High

615

805

1010

1210

605

805

1005

1205

600

800

1000

1200

600

800

1000

1200

595

800

995

1200

590

795

995

1195

590

790

990

1195

585

785

985

1190

580

780

975

1180

MBVB16

CP1X00A*

A B C D Low Low Low

Low

690

850

980

1110

680

830

970

1085

670

800

940

1070

665

795

935

1055

660

790

930

1045

655

785

910

1025

625

775

890

1000

595

750

865

990

575

725

860

975

A B C D High High High

High

1045

1245

1415

1605

1015

1215

1410

1600

1000

1200

1400

1600

990

1180

1365

1540

975

1175

1360

1530

950

1165

1350

1520

935

1150

1340

1510

920

1130

1330

1500

900

1115

1320

1490

MBVB20 DP1X00A* A B C D Low Low Low

Low

835

1075

1210

1345

815

1070

1205

1340

800

1070

1200

1340

800

1065

1200

1320

795

1050

1195

1320

795

1045

1190

1315

790

1045

1190

1315

775

1040

1185

1305

750

1035

1175

1305

A B C D High High High

High

1210

1610

1830

2020

1205

1605

1805

2010

1200

1600

1800

2000

1195

1540

1785

1995

1150

1535

1760

1995

1150

1535

1760

1970

1145

1530

1755

1970

1135

1520

1750

1965

1115

1510

1715

1955

Cooling and Heat Pump Airflow

S1 S2 Speed Tap MBVB12BP1X00

Airflow (SCFM)

MBVB16CP1X00

Airflow (SCFM)

MBVB20DP1X00

Airflow (SCFM)

off off A 600 1000 1200
on off B 800 1200 1600
off on C 1000 1400 1800
on on D 1200 1600 2000
Cooling / HP / Aux Trim Cooling Profile
S3 S4 Trim Value S5 S6
off off 0 off off A
on off 10% on off B
off on -10% off on C
on on 0 on on D

Heat Kit Airflow

S9                       S10                      S11 Heater KW MBVB12BP1X00

Airflow (SCFM)

MBVB16CP1X00

Airflow (SCFM)

MBVB20DP1X00

Airflow (SCFM)

off off on 20 NA NA 2000
off on off 15 1400 1500 1500
off on on 10 1000 1000 1200
on off off 8 740 1000 1000
on off on 6 635 800 800
 

Models

Circuit 1 (208V/240V) Circuit 2 (208V/240V) Single-Point Kit (208V/240V)
Heater Amps MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP²
MBVB12BP1X00AB 0/0 4.9/4.9 15/15
HKTAN031 10.8/12.5 18.4/20.5 20/25
HKTA*051 18.1/20.8 27.4/30.9 30/35
HKTAN061 21.7/25.0 32.0/36.1 35/40
HKTA*081 25.3/29.2 36.5/41.3 40/45
HKTA*101 36.1/41.7 50.0/57.0 50/60
HKTAD151 36.1/41.7 50.0/57.0 50/60 18/20.8 22.5/26.0 25/30 72.6/83.0 80/90
MBVB16CP1X00AB 0/0 6.5/6.5 15/15
HKTAN031 10.8/12.5 20.0/22.1 20/25
HKTA*051 18.1/20.8 29.1/32.5 30/35
HKTAN061 21.7/25.0 33.6/37.8 35/40
HKTA*081 25.3/29.2 38.1/43.0 40/45
HKTA*101 36.1/41.7 51.6/58.6 60/60
HKTAD151 36.1/41.7 51.6/58.6 60/60 18/20.8 22.5/26.0 25/30 74.2/84.6 80/90
MBVB20DP1X00AB 0/0 6.5/6.5 15/15
HKTAN031 10.8/12.5 20.0/22.1 20/25
HKTA*051 18.1/20.8 29.1/32.5 30/35
HKTAN061 21.7/25.0 33.6/37.8 35/40
HKTA*081 25.3/29.2 38.1/43.0 40/45
HKTA*101 36.1/41.7 51.6/58.6 60/60
HKTAD151 36.1/41.7 51.6/58.6 60/60 18/20.8 22.5/26.0 25/30 74.2/84.6 80/90
HKTAD201 36.1/41.7 51.6/58.6 60/60 36.1/41.7 45.2/52.1 50/60 96.8/111 100/125
  • All ampacities noted above include air handler motor amps
  • Circuit 1: Single-phase for Air Handlers / Circuit 2: Three-phase for HKR3 Heater Kits ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25
  • ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps
  • * D – Service disconnect, N – No service disconnect
  • — indicates Not Required

Heating kW Correction Factor

Supply Voltage 240 230 220 210 208
Correction Factor 1.00 0.92 0.84 0.77 0.75

Multiply the 240-volt heating capacity by correction factors.

Dimensions

Side and Front ViewsGoodman-MBVB-Variable-Speed-Modular-Blower-FIG-2

 

Model

Dimensions
Width Depth Height
MBVB12BP1X00 17½” 21″ 26″
MBVB16CP1X00 21″ 21″ 30″
MBVB20DP1X00 24½” 21″ 30″

Top ViewGoodman-MBVB-Variable-Speed-Modular-Blower-FIG-3Goodman-MBVB-Variable-Speed-Modular-Blower-FIG-4

  • Warning: High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
  • Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Accessories

Single Point Kit

HKTAD151 HKTAD201
SPW-01 X X
  • Can only be installed along with the above heat kits. This kit will fit any MBVK blower as long as a compatible heat kit is installed in the unit.

MBVB Blower Performance Data Dipswitch Summary

Dipswitch Number Function Default Setting
S1 – S2* Cooling / HP Airflow A/B/C/D Airflow D
S3 – S4* Cooling / HP / Aux Trim

(-10%, 0, +10%)

No Trim
S5 – S6* Cooling Profile

A, B, C, D

Profile 1
S7* Dehum (on/off) Off
S8 Unused On
S9 – S11 Heater Kit Kw Off/Off/Off
  • Valid only if the system is wired in legacy mode. If the system is wired in the 4-wire communicating mode, these functions are selected via the user menu in the CTK01AA T-STAT.

Heat Kit Selection

Model MBVB12BP1X00 MBVB16CP1X00 MBVB20DP1X00
HKTAN031 X X X
HKTAN051 X X X
HKTAD051 X X X
HKTAN061 X X X
HKTAN081 X X X
HKTAD081 X X X
HKTAN101 X X X
HKTAD101 X X X
HKTAD151 X X X
HKTAD201 X

CUSTOMER SERVICE

  • Refer to the minimum airflow requirements for each of the heat kits.
  • Indicates Not Permitted.
  • Our continuing commitment to quality products may mean a change in specifications without notice.
  • 2023 DAIKINCOMFORTTECHNOLOGIES MANUFACTURING L.P.
  • Houston, Texas
  • Printed in the USA.
  • www.goodmanmfg.com

Warranty

  • Complete warranty details available from your local dealer or at www.goodmanmfg.com.
  • To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation.
  • Online registration is not required in California or Québec.
  • The duration of warranty coverage in Texas and Florida differs in some cases.

Documents / Resources

PDF thumbnailMBVB Variable Speed Modular Blower
User Manual · Multi-position, Variable speed, ECM-based, Modular Blower, Comfortbridge Compatible, MBVB Variable Speed Modular Blower, MBVB, Variable Speed Modular Blower

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.