HY369 TRV Thermostatic Radiator Valve User Manual
Search for ” Smart RM or Smart life ” Download the Wifi App with the following icon. Remark: The phone and the gateway must be connected to the same router |
After the actuator stroke detection is completed, long-press the key combination “ ![]() ![]() |
APP need to connect to gateway,then connect to device Initial Setting
![]() |
![]() |
![]() |
![]() |
First-time open thermostat, it displays all icons for 3s | ![]() ![]() ![]() ![]() |
, Test One. “ADA” displays. Press ![]() |
Test Two. Finished |
! Adjustment Error(If solved errors restart by pressing )
Er1 Short route: the pin was stuck which is away from terminus 2mm
Er2 The temperature sensor is disconnected or damaged
Low battery, the icon of battery is blinking After putting batteries inside,
is on display then mean okay, if flashing, then breakdown.
Technical Data
Power: 3*2 AA* 1.5V alkaline batteries | Maximum current:90mA |
Working temperature::-10~60°C | Display accuracy::0.5℃ |
The default range of temperature adjustment:5~35°C | Probe sensor::NTC(10k)1% |
Range of temperature display::0~70°C | Thread size: M30*1.5 |
Insulating condition: Normal environment | Size(mm):66*52*100mm |
Running program: Set per 1 week as a cycle | Maximum route:4.5mm |
NO | Explain |
A | 7 days program 6 times period, Low battery icon![]() ![]() |
B | Energy-saving mode![]() ![]() |
C | |
Holiday mode ![]() ![]() ![]() ![]() |
|
D | |
Clock![]() ![]() |
|
E | Room temperature![]() ![]() ![]() |
I: | ![]() 2 Long press 3s to access programmable mode |
G | ![]() 2) Long press to activate force close valve (display (OFF] ) |
H | ![]() |
2) Press ![]() ![]() ![]() |
|
I | ![]() 2) Long press to activate force open valve (display OP) |
J | ![]() |
1)Confirm function 2)BOOST is the quick heating mode, short press BOOST to open or close quick heating mode, press ![]() 3)Long press to unlock ( about 10min will auto-lock) |
Function
1) Time Setting
Long press for 3s to access Time Setting. Press
to switch, then press
to confirm. Press, to change
minutes, hours, week. Press
to confirm.
2) Holiday Mode
Press to switch into
Holiday Mode. Press to confirm. Press,
to change temperature and days. Press
to confirm, short press
switch to manual mode or auto model, and exit holiday mode
3) Open Window Detection
It is the default that the open window function was closed after being put into batteries and display – – ,
And open it on advance setting A2 (once change batteries, should set it again)
When room temperature suddenly drops into temp threshold (adjust range 5 ℃-25℃), the valve closes for 15 minutes (adjust range 5-60 min). After finishing, if the room temp is still lower than the temp threshold, it will keep this mode.
4) Programmable Mode
P2 5+2 days programmable (Default)
Long press for 3s to access Programmable Mode. Press
to switch into P (5+2 Days, 6+1 Days, 7 Days). Press to
confirm.Press,
to change value.
P0 Manual Programmable(Default)
Period | Default Period | Default temperature |
1 | 6:00-8:00 | 20℃ |
2 | 8:00-11:30 | 15℃ |
3 | 11:30—12:30 | 15℃ |
4 | 12:30—17:30 | 15℃ |
5 | 17:30—22:00 | 20℃ |
6 | 22:00—6:00 | 15℃ |
Advanced Options
Long press for 3-5 to access Advanced Option. Press
to switch
into. Press
to confirm. Press
, to change value. After 10s will save and exit
NO | Description | Range |
Default |
||
Al | Temperature Calibration | -9-+9°C | 0.5°C | ||
A3 | Open Window Detection | I open and set open window temperature: – – mean closed it ,press IA ![]() 2 Valve closing time(running time of open window): 0: 05-1: 00 (press one time ,change 5min) , after time is 0,then closed it |
1 Temp threshold:
– – °C( Default:Close ) 2 0:15 mean valve close time |
||
Auto be locked | 0: cancel this function 1: open this function | 0 | |||
A4 | MM Temperature | 1-15°C | 5°C | ||
AS | Max Temperature | 16-70°C | 35°C | ||
A6 | BOOST Extension Per press ![]() |
100s-900s | 300 | ||
A– | Valve Opening | 100 mean valve opening100% 5 mean valve opening 5% | |||
A8 | Temperature Tolerance | 0.5-1.5°C | 1℃ | ||
A9 | Factory Default | BOOST
Display Ao, press whole |
|||
Display Ao, press ![]() |
|||||
RISK OF ELECTRICAL SHOCK
Please arrange for a professional technician to install the product according to drawings and instructions. Disconnect the power supply before making any connection. Contact with components carrying hazardous voltage can cause electrical shock.
Documents / Resources
![]() |