global sources HY02TP Programmable Plug In Thermostat Instructions
Product Model
- HY02TP
- HY02TPR(without backlight)
Product Instruction
This is programmable plug in thermostat, it is used for controlling air conditioner, carbon crystal heating panel, electric heating oven, heater and so on cooling heating devices, it is used conveniently and beautiful structure.
Technical Data
- Voltage: AC200~240V, 50HZ or 110V
- Load Current: 16A(electric heating)
- Temperature Control Precision: ±1ºC
- Temperature Setting Range: 5ºC – 35ºC
- Self Consumption Power: <0.3W
- Temperature Sensor: NTC
NO. |
symbols |
Represent |
1 |
![]() |
Power On/Off |
2 | ![]() |
Selection Setting: short press SET button to switch manual control/automatic control; long press SET button for 3 seconds to enter into set clock and timing power on/off. |
3 |
![]() |
Confirm Button/Enter Button |
4 | ![]() |
Increase Button |
5 |
![]() ![]() |
Decrease Button |
6 | Indicator![]() |
Light on is power on, light off is power off. Light on is heating on, light offer is heating off(Australian socket) |
Display And Function Instruction
NO. | symbols | Explanation |
1 |
|
Automatic control mode: when automatic control, manual control “ |
2 | ![]() |
Manual control mode: when manual control, automatic control “ |
3 |
![]() ![]() |
When automatic control, it need reset temperature, it can press “ ![]() ![]() ![]() ![]() ![]() |
4 | ![]() |
Heating mode: relay connect, it will display “ |
5 |
![]() |
Cooling mode: relay connect, it will display“ ![]() |
6 | ![]() ![]() |
6 periods programmable icon |
7 |
![]() |
Timing power on/off icon, it set time of power on/off: if press ” |
8 |
![]() |
Room temperature |
9 | ![]() |
Children lock: no any operation for 10 minutes, buttons will lock automatically, Press down button “ |
10 |
![]() |
Ventilation mode |
11 | ![]() |
Clock setting icon |
Quick Instruction Of Operation Icon
Clock, timing power on/off setting
Setting Screen
Clock Setting
Long press“” for 3 seconds then move your finger to enter into setting screen, short press “
”to choose “
” icon(
flashing),press “
” enter into clock setting, it displays minute, hour, week, press “
” or “
” to adjust value. Press “
” to confirm and switch to next hour ,week setting, it is the same as minute setting. Press “
” button to save all time setting and return to previous screen.
Timing Power On/Off Setting
Long press“ ” for 3 seconds then move your finger to enter into setting screen, short press“
”to choose“
”(
lashing) to set time of timing power on; press “
” or “
” to adjust value. Press“
” to choose“
” and set timing power off. Cancel timing power on/off: press ”
” to set
as 00:00,press ”
” to set
as 00:00.It will quit automatically after setting finished 5 seconds, or press “
” button return to previous screen.
6 Periods Programmable Setting
Explanation |
Print screen |
Long press“ ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() ![]()
|
Note1. the usage of temporary manual mode: When thermostat is in period control, such as current time is 16:00,thermostat will set corresponding room temperature(factory setting is 15ºC) as per current period(factory setting afternoon going out period is 12:30-17:30),if current day you end work 1 hour earlier,(16:30 is 1 hour earlier than 17:30),you can press increase/decrease button temporarily to modify temperature to the temperature you wanted(such as 20ºC),then the thermostat will keep the room temperature in 20ºC until next period, no any operation, thermostat will run the setting temperature (thermostat default 20ºC) automatically of afternoon entering room period(17:30-22:00) at 17:30.
Factory default periods programmable
Period |
Icon | Default Time |
Default Temperature |
|
Working Day |
1 |
![]() |
06:00 | 20℃ |
2 | ![]() |
08:00 |
15℃ |
|
3 |
![]() |
11:30 | 15℃ | |
4 | ![]() |
12:30 |
15℃ |
|
5 |
![]() |
17:30 | 20℃ | |
6 | ![]() |
22:00 |
15℃ |
|
Weekend |
1 | ![]() |
08:00 | 20℃ |
2 | ![]() |
23:00 |
15℃ |
Advanced Setting(Suggest To Operate By Professional People)
Under power on state, press “ ” for 3 seconds then move your finger, enter into advanced setting, then press“
”to choose one option, press“
” or “
”to adjust value. To press“
” to next option. It will save setting and quit after setting finished 5 seconds.
No. |
Display | Setting Option | Data Setting Function |
Factory Default Setting |
1 | A1 | Ventilation function setting | “ ![]() ![]() |
15 Minutes |
2 | A2 | External Sensors Limit Temperature Control Return Difference |
1-9ºC | 2ºC |
3 | A3 | Setting Temperature Highest Limit |
20-70ºC |
35ºC |
4 | A4 | Setting Temperature Lowest Limit | 1-10ºC | 5ºC |
5 | A5 | Measuring Temperature Calibration | ±5ºC | 0.5ºC Accuracy Calibration |
6 | A6 | Anti-freezing Function | 00:Anti-freezing function close
01:Anti-freezing function open |
00:Anti-freezing function close |
7 | A7 | Power On Memory Function | 0:Power On Memory Function
1:No Power On Memory Function |
0:No Power On Memory Function |
8 | A8 | Working Mode | 00:Cooling Mode
01:Heating Mode |
01:Heating Mode |
9 | A9 | Programmable And Non-programmable | 00:Programmable
01:Non-programmable |
00:Programmable |
10 | A0 | Factory Setting | 88:it just display, no any meaning
00:Return to factory setting |
88:it just display, no any meaning |
Documents / Resources
![]() |