Introdución
This manual provides instructions for the installation and maintenance of the Pentair 350090 Cam and Ramp Clamp. This component is designed as a direct replacement part for Pentair SuperFlo Inground Pool and Spa Pumps, ensuring a secure seal for the pump's lid.
The Pentair 350090 clamp is crucial for maintaining the integrity of your pump's filtration system, preventing leaks and ensuring optimal performance. Proper installation and care will extend the life of your pump and its components.
Produto rematadoview
The Pentair 350090 is a cam and ramp clamp specifically engineered for SuperFlo Inground Pool and Spa Pumps. It measures approximately 13 inches in length, 1.25 inches in height, and 12 inches in width, and weighs about 1.28 ounces. This clamp secures the pump lid, which typically includes a clear cover and an O-ring (not included with this replacement clamp).

Figura 1: Arriba view of the Pentair 350090 Cam and Ramp Clamp. This image shows the circular design with two extended handles for gripping and the internal cam and ramp mechanism for securing the pump lid.

Figura 2: Abaixo view of the Pentair 350090 Cam and Ramp Clamp. This perspective highlights the underside of the clamp, showing the grooves and structure that engage with the pump housing and lid.
Instrucións de instalación
Follow these steps to replace the cam and ramp clamp on your Pentair SuperFlo pump. Ensure the pump is turned off and disconnected from power before beginning any maintenance.
- A seguridade primeiro: Turn off the pump at the circuit breaker and disconnect all power. Relieve any pressure in the system before attempting to open the pump.
- Remove Old Clamp: Carefully remove the existing cam and ramp clamp. If it is broken, remove all fragments.
- Inspect Lid and O-Ring: Inspect your pump's clear lid and O-ring for any signs of wear, cracks, or damage. This replacement part includes only the clamp; the lid and O-ring must be reused from your existing pump or replaced separately if damaged.
- Install Lid and O-Ring: Ensure the O-ring is properly seated around the pump lid. Place the lid onto the pump housing, aligning it correctly.
- Position New Clamp: Place the new Pentair 350090 Cam and Ramp Clamp over the pump lid and housing. Ensure it sits flush and evenly around the entire circumference.
- Asegure o Clamp: Xire o clamp clockwise until it is firmly seated and the lid is securely held in place. The cam and ramp mechanism will create a tight seal. Do not overtighten, but ensure it is snug enough to prevent leaks.
- Comprobar fugas: Unha vez que o clamp is installed, restore power to the pump and turn it on. Carefully observe the pump lid area for any signs of water leaks. If leaks occur, turn off the pump, relieve pressure, and re-adjust the clamp or inspect the O-ring and lid for proper seating.
Note: Always refer to your specific Pentair SuperFlo pump's original manual for detailed instructions on pump disassembly and reassembly, especially regarding pressure relief and electrical safety.
Mantemento
To ensure the longevity and proper function of your Pentair 350090 Cam and Ramp Clamp and your SuperFlo pump, consider the following maintenance tips:
- Inspección periódica: Inspeccionar periodicamente o clamp for any signs of cracks, warping, or damage. Replace immediately if any damage is observed to prevent pump failure or leaks.
- Coidado da xunta tórica: The O-ring (not included with this clamp) is critical for a watertight seal. Inspect it regularly for dryness, cracks, or flattening. Lubricate the O-ring with a silicone-based lubricant designed for pool equipment to keep it pliable and ensure a good seal.
- Invernización: During freezing weather, ensure your pump is properly drained to prevent water from freezing and expanding, which can cause damage to the clamp and other pump components.
- Limpeza: Manteña o clamp and the area around the pump lid clean from debris, dirt, and chemical residue that could degrade the material over time.
Resolución de problemas
If you encounter issues after replacing the cam and ramp clamp, consulte os seguintes problemas e solucións comúns:
- Water Leakage from Pump Lid:
- Asegúrese de que o clamp is fully and evenly tightened.
- Check the O-ring for proper seating, damage, or dryness. Replace the O-ring if necessary.
- Inspect the pump lid for cracks or warping. Replace the lid if damaged.
- Air Entering the Pump (Loss of Prime):
- A loose or improperly seated clamp can allow air to be drawn into the pump. Re-tighten the clamp.
- Verify the O-ring is in good condition and correctly positioned.
- Check other pump connections for air leaks.
- Clamp Non encaixa:
- Confirm that the pump model is a Pentair SuperFlo Inground Pool/Spa Pump. This clamp is specifically designed for these models.
- Verify the part number 350090 matches the required replacement part for your pump.
Especificacións
| Número de peza | 350090 |
| Bombas compatibles | Pentair SuperFlo Inground Pool and Spa Pumps |
| Dimensións (L x W x H) | 13 x 12 x 1.25 polgadas |
| Peso do elemento | 1.28 onzas |
| Material | Plástico duradeiro |
| Fabricante | Pentair |
| Número de modelo do artigo | PEN350090Z |
Garantía e Soporte
Information regarding specific warranty terms for the Pentair 350090 Cam and Ramp Clamp is not provided in this document. For warranty details, technical support, or further assistance, please contact Pentair customer service or refer to the official Pentair websitio.
A miúdo podes atopar recursos adicionais e información de contacto na Pentair Store on Amazon or the main Pentair corporate websitio.