GIRA 2472 00 1 Way Switch and Control Light Instruction Manual

2472 00 1 Way Switch and Control Light

Specifications

  • Product: RTC 230 V~ with NC / NO contact, 1-way switch and
    control light
  • Order Number: 2472 00

Product Information

Safety Instructions

Electrical devices must be installed and connected by
electrically skilled persons to prevent injuries, fire, or property
damage. Always disconnect before working on the device or load to
avoid electric shock.

Device Components

Components include room temperature controller insert, cover
frame, status LED, central plate, control knob, internal
temperature sensor, and adjustment rings for temperature limit.
Ensure the temperature sensor remains clean during renovation
work.

Intended Use

The product is designed for controlling temperature and
switching between heating and cooling modes.

Product Characteristics

The product features NC / NO contact, 1-way switch, and a
control light.

Functional Description

The product offers features like ECO mode, cooling mode,
temperature drop detection, offset adjustment, controller
adaptation, and setting valve type.

Product Usage Instructions

Operation

Brief Overview:

  • Function: Change room temperature
  • Control Knob: Turn right or left to adjust
    temperature
  • Display Operating Mode: Press the control knob
    briefly
  • Status LED: Indicates current operating
    mode

Increasing or Reducing Room Temperature: Turn
the control knob to the right or left. If the setpoint temperature
is not reached, the LED lights up for a maximum of 2 minutes in the
color of the current operating mode.

Indication of Current Operating Mode: Press the
control knob briefly. The LED lights up for 10 seconds in the color
of the current operating mode (Orange = frost protection, Blue =
cooling mode, Red = heating mode).

FAQ

Q: Can this product be installed by non-electrically skilled
persons?

A: No, electrical devices should only be mounted and connected
by electrically skilled persons to prevent accidents.

Q: How do I switch between heating and cooling modes?

A: You can switch between heating and cooling modes via the
control knob or by wiring the input terminal C with 230 V.

“`

Operating instructions RTC 230 V~ with NC / NO contact, 1-way switch and control light Order no. 2472 00
Product image non-binding

82404022 / 20.06.2025

RTC 230 V~ with NC / NO contact, 1-way switch and control light
Table of Contents
1 Safety instructions ……………………………………………………………………………………………… 3 2 Device components ……………………………………………………………………………………………. 3 3 Intended use ……………………………………………………………………………………………………… 3 4 Product characteristics ……………………………………………………………………………………….. 4 5 Functional description…………………………………………………………………………………………. 4 6 Operation ………………………………………………………………………………………………………….. 5 7 Information for electrically skilled persons ……………………………………………………………… 6
7.1 Commissioning ………………………………………………………………………………………… 8 8 Technical data …………………………………………………………………………………………………. 10 9 Warranty …………………………………………………………………………………………………………. 10

82404022

20.06.2025

2 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light
1 Safety instructions
Electrical devices may be mounted and connected only by electrically skilled persons. Serious injuries, fire or property damage are possible. Please read and follow the manual fully. Danger of electric shock. Always disconnect before carrying out work on the device or load. In so doing, take all the circuit breakers into account, which support dangerous voltages to the device and or load. These instructions are an integral part of the product, and must remain with the end customer.
2 Device components

Figure 1: Device components

(1)

Room temperature controller insert

(2)

Cover frame

(3)

Status LED

(4)

Central plate

(5)

Control knob

(6)

Internal temperature sensor

(7)

Adjustment rings for temperature limit

During renovation work, the temperature sensor (6) must not become dirty or be painted over.

3 Intended use
­ Electronic room temperature controller for controlling electrothermal valve drives for 230 V~
­ Control of the room temperature in closed rooms

82404022

20.06.2025

3 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light
­ Mounting in appliance box with dimensions according to DIN 49073
4 Product characteristics
­ Manually setting a comfort temperature ­ Manually switching off the temperature control ­ Input terminal for activation of reduction temperature (ECO) via central clock ­ Input terminal for activating the cooling mode via central control ­ Internal temperature sensor ­ Frost protection function ­ Silent switching ­ Temperature drop detection (adjusting to frost protection temperature when
window is opened) ­ Controller output working method: pulse width modulation (PWM) or two-point
switchable ­ Adaptation to valve type (deenergised opened or deenergised closed, switch-
able) ­ Offset adjustment (correction value for measured temperature) ­ Valve protection function (once a week opening and closing of valve)
5 Functional description
Lowering mode (ECO)
In many areas of the building it makes sense for the temperature to be set to a lower level at certain times rather than to heat permanently to the comfort temperature. By connecting the input terminal Ø to 230 V, the temperature is reduced by 4 °C. This should be controlled by a central clock.
Cooling mode
Modern heat pump systems often also provide the option of cooling rooms. In cooling mode, it is possible to change the cooling temperature using the control knob. Switching between heating and cooling mode is done via the control knob or by wiring the input terminal “C” with 230 V.
Temperature drop detection
In the event of a sharp drop in temperature, e.g. after opening a window, the system regulates to the frost protection temperature of 5 °C for a maximum of 30 minutes. Pressing or turning the control knob cancels the operation.

82404022

20.06.2025

4 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light
Offset
This function allows the adjustment of the position of the control knob so that it corresponds to the room temperature. Thus, the indication of the temperature via the control button is comparable in different rooms. An adaptation of up to +/- 3 °C is possible.
Controller adaptation
Depending on the heating system, the control behaviour can be adjusted. Pulse width modulated control (factory setting): Optimised for electrothermal valve drives (see Technical data): The output is not permanently actuated, but for a time period (pulse width) that depends on the difference between setpoint and actual temperature. This method brings the actual temperature gradually closer to the setpoint temperature. Two-point control: The output remains switched on until the selected setpoint temperature has been exceeded by 0.5 °C. The output will not be switched on again until the setpoint value is undercut by 0.5 °C. Since most heating systems respond very slowly, this type of control can entail temperature overshooting.
Setting the valve type
Depending on the electrothermal valve drive used, an adaptation to the valve type must be made. There are valve drives where the valve is opened (deenergised opened) or closed (deenergised closed, factory setting) when no supply voltage is applied.

6 Operation

Brief overview

Function

Control knob

Change room tem- … turn right or left perature

Display operating … press briefly mode

Status LED

LED colour

maximum 2 minutes Red = heating mode Blue = cooling mode

Orange = frost protection (10 seconds)

10 seconds.

Red = heating mode Blue = cooling mode Orange = frost protection

Increasing or reducing the room temperature

Turn the control knob to the right or left.
If the setpoint temperature is not reached, the LED lights up for a maximum of 2 minutes in the colour of the current operating mode.

82404022

20.06.2025

5 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light
In the middle position, the device regulates to approx. 20 °C target temperature. The room temperature reached depends on the installation location of the device and the ambient conditions. The lowest setpoint temperature is approx. 5 °C and the highest setpoint temperature is approx. 30 °C (see figure 4).
Indication of the current operating mode
Press the control knob briefly. The LED lights up for 10 seconds in the colour of the current operating mode. Orange = frost protection, blue = cooling mode, red = heating mode.
Switching off the temperature control
Press the control knob for longer than 2 seconds until the LED lights up orange. The device has switched to frost protection. The frost protection prevents the temperature from falling below 5 °C. Each time the control knob is turned, the LED lights up orange for 10 seconds.
To activate the temperature control, press the control knob again for more than two seconds.
The device switches back to the previous operating mode. The LED lights up for 10 seconds. Red = heating mode, blue = cooling mode.
Manual switching between heating and cooling mode
If 230 V is present at the input terminal C, manual switching to heating mode is not possible.
Press the control knob for longer than 4 seconds until the LED flashes red in heating mode or flashes blue in cooling mode.
Briefly press the control knob again to change the operating mode. Press the control knob for longer than one second until the LED lights up con-
tinuously to accept the displayed operating mode. After 10 seconds without actuation, the displayed operating mode is automatically adopted.
Red = heating mode, blue = cooling mode.
7 Information for electrically skilled persons
Selecting a suitable installation location
­ Recommended installation height: 1.50 m on interior walls. ­ Do not mount the device near sources of interference, such as ovens, refriger-
ators, draughts (e.g. next to the door) or direct sunlight. This affects the temperature measurement of the internal temperature sensor.

82404022

20.06.2025

6 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light
­ Do not mount the device within shelf walls or behind curtains and similar covers.
­ Do not use the device in multiple combinations with heat-generating devices such as dimmers.
DANGER!
Mortal danger of electric shock. Disconnect the device. Cover up live parts.
Connecting and fitting the device

Figure 2: Connection example of the insert

Figure 3: Clampable conductor cross-section
Connect electrothermal valve drive (10) to insert (1) according to connection diagram (see figure 2). Observe the conductor cross-sections (see figure 3).

82404022

20.06.2025

7 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light
Device defect due to incorrect or excessive load. Observe information on valve drives (technical data), check performance data if necessary.
Optionally, connect the lowering mode input Ø via a switching contact of a central clock (8). If 230 V is applied to the input, the setpoint temperature is reduced by 4 °C.
Optionally, connect the cooling input C via a switching contact of the heating system (9). If 230 V is applied to input C, the cooling mode is active. If 230 V is switched off, the device automatically switches to heating mode. After each switchover, the LED lights up for 10 seconds in the colour of the current operating mode.
Fit device in appliance box; device connection terminals must be at the bottom.
Fit cover frame (2), central plate (4) and control knob (5). Switch on mains voltage.
When testing the function of the device, make sure that the output is activated with a delay of up to 30 seconds.
7.1 Commissioning
Setting the control mode and valve type
Default setting: ­ Pulse width modulated control (PWM) ­ Valve type deenergised closed (NC)
This setting can be used with most heating systems without adaptation.
Changing the settings
Press the control knob for longer than 20 seconds. The LED flashes green for PWM control and green/blue for 2-point control.
Press the control knob briefly: The control behaviour is changed. Press the control knob for longer than one second: The control behaviour is
saved. Adapting the valve type. The LED flashes red for valve type “deenergised closed” (NC) and red/blue for valve type “deenergised opened” (NO).
Press the control knob briefly: The valve type is changed. Press the control knob for longer than one second: The valve type is saved.
The setting mode is exited automatically.

82404022

20.06.2025

8 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light
After approx. 2 minutes without any operation the menu is exited without saving.
Setting the temperature limits The room temperature controller has a setting range of 5 … 30 °C. The adjustment rings on the central plate can be used to limit the temperature setting range. The specified temperature values may deviate from the actual room temperature depending on the installation location.

Figure 4: Adjustment rings for temperature limit
Pull the control knob (5) off the central plate (4) so that the adjustment rings (7) are visible (see figure 4). The temperature values shown in the picture are for orientation purposes.
Turn the large blue adjustment ring clockwise to the desired minimum temperature. Each notch corresponds to a change of about 1 °C.
Turn the small red adjustment ring anticlockwise to the desired maximum temperature.
Replace the control knob, observing the coding of the control knob and rotary axle.
Setting the offset
This function allows the adjustment of the position of the control knob so that it corresponds to the room temperature. Thus, the indication of the temperature via the control button is comparable in different rooms. An adaptation of up to +/- 3 °C is possible.

82404022

20.06.2025

9 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light

This setting is only possible if the lower temperature limit has not been raised by the blue setting ring (see Setting the temperature limits).
Precondition: The desired setpoint temperature has been reached in the room. Turn the control knob to 5 °C (left stop) and press twice in quick succession (double-click). The LED flashes quickly, alternately red and green.
Turn the control knob to the desired position for the current room temperature and press it for longer than one second. The control knob position is saved and the LED lights up green for 5 seconds.
If the LED flashes red for 5 seconds, the change was greater than +/- 3 °C and the adaptation is discarded.

8 Technical data
Rated voltage Mains frequency Standby power Connected load Sum of switch-on currents (100 ms) Connection of thermal valve drives Order no.: 2169 00 Valve drive from other manufacturers Ambient temperature Storage/transport temperature Cable length inputs Controller class (EU 811/2013) Contribution to energy efficiency Data according to DIN EN 60730-1 Type of action Degree of soiling Measured surge voltage

AC 230 V ~ 50 / 60 Hz Max. 0.5 W 20 W Max. 5.5 A
1 … 10 1 … 3
-5 … +45 °C -25 … +70 °C
Max. 100 m IV
2%
1.Y 2
4000 V

9 Warranty
The warranty is provided by the specialist trade in accordance with statutory requirements. Please submit or send faulty devices postage paid together with a fault description to your responsible salesperson (specialist trade / installation company / electrical specialist trade). They will forward the devices to the Gira Service Center.

Gira Giersiepen GmbH & Co. KG

82404022

20.06.2025

10 / 11

RTC 230 V~ with NC / NO contact, 1-way switch and control light
Elektro-InstallationsSysteme
Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald
Postfach 12 20 42461 Radevormwald
Deutschland
Tel +49(0)21 95 – 602-0 Fax +49(0)21 95 – 602-191
www.gira.de info@gira.de

82404022

20.06.2025

11 / 11