GETINGE Corin and Otesus Operating Tables Instruction Manual

Corin and Otesus Operating Tables

Product Information

Specifications:

  • Product Name: Maquet Corin & Maquet Otesus Operating Tables
    with Traction Adapter
  • Applications: Orthopedics and Traumatology
  • Supports: Hyperextension, abduction, adduction, and rotation of
    the legs
  • Traction Adapter Compatibility: All Maquet Otesus Table
    stationary and mobile columns
  • Tensioning Capacity: Up to 80 kg (~800 N)
  • Material: Carbon Fiber

Product Usage Instructions:

Step 1: Remove Laminated Paper Plate

Begin by removing the laminated paper plate from the operating
table.

Step 2: Attaching the Traction Adapter

Attach the traction adapter (1003.72AC) to convert the table
into a specialized orthopedic setup.

Step 3: Install Carbon Fiber Extension Plate

Install the 3D radiolucent carbon fiber extension plate with
three holes (1433.66AC) including the counter traction post for
imaging access to the pelvic and hip area.

Recommended Uses:

  • 1-hole version (1433.66BC): Direct Anterior Approach
    procedures
  • 3-hole version (1433.66AC): Femur nailing and dynamic hip screw
    procedures

Step 4: Attach Carbon Fiber Traction Bars

Attach carbon fiber traction bars for leg positioning control
and stability.

Note: Detaching the bars is simple with the
snap-in mechanism for easy removal.

Frequently Asked Questions (FAQ):

Q: Can the traction adapter be used with other operating
tables?

A: The traction adapter is compatible only with Maquet Otesus
Table stationary and mobile columns.

Q: What is the tensioning capacity of the screw tension
device?

A: The screw tension device supports tensioning up to 80 kg
(~800 N).

“`

Maquet Corin & Maquet Otesus Operating Tables
Facilitating procedures in Orthopedics and Traumatology with the Traction Adapter

Maquet Corin & Maquet Otesus
Facilitating procedures in Orthopedics and Traumatology with the Traction Adapter

Proper positioning can make all the difference in orthopedic procedures, enabling less invasive techniques that can improve patient outcomes and accelerate recovery.
Getinge has set a new standard to support specialized orthopedic and traumatology applications enabling hyperextension, abduction, adduction and rotation of the legs.
Applications scopes
· Direct Anterior Approach total hip arthroplasty / replacement · Dynamic hip screw / Hip pinning · Hip arthroscopy · Pelvic fracture · Femoral nailing · Femoral plating

The traction adapter is compatible with all Maquet Otesus Table stationary and mobile columns, enabling full use of your existing resources

2

Maquet Corin & Maquet Otesus
Overview
Screw tension device
Enables smooth sliding along the entire carbon fiber (CF) bars and can be easily operated from the foot end without disrupting the surgical workflow. It supports tensioning up to 80 kg (~ 800 N), providing optimal stability for physically active or athletic patients. Surgeons have full control over leg positioning, including angulation, rotation, and height adjustment.
Traction bar 1007.41B0 for horizontal movements
Enables effortless horizontal adjustments with one-hand operation, eliminating the need to support the leg’s weight during repositioning.
Versatile configuration
Use identical bars on both sides, or mix and match setups to suit your specific needs.

Carbon fiber extension plates
Provides good imaging access for 3D acquisitions, as well as for both inlet and outlet view.
The 1-hole version (1433.66BC) is ideal for DAA (Direct Anterior Approach) procedures, offering greater freedom to adjust leg positioning without obstructing downward movements. Best used in combination with the Carbon Fiber traction bar with ball joint (1007.40B0).
The 3-hole version (1433.66AC) is ideal for femur nailing and dynamic hip screw procedures, as it offers enhanced support for the patient’s pelvic area through selectable countertraction post positions. Best used in combination with the CF traction bar (1007.41B0) for optimized horizontal movements.
Traction bar 1007.40B0 with ball joint
Allows complete freedom of leg adjustment thanks to its 360° movement capability. The automatic locking function helps prevent injuries in case the user accidentally loses grip on the handle.
3

Maquet Corin & Maquet Otesus
Easily convert your Maquet Corin or Otesus into specialized operating tables

Step 1
Remove the laminated paper plate.

Step 2
Attaching the traction adapter (1003.72AC) enables an easy conversion from a universal operating table to a specialized orthopedic setup.

Step 3
Install the 3D radiolucent carbon fiber extension plate with three holes (1433.66AC) including the counter traction post to ensure good imaging access to the pelvic and hip area. For example, in cases of femoral and pelvic fractures, the use of the 3-hole version is recommended. An alternative with one position for the countertraction post (1433.66BC) is recommended for total hip arthroplasty.

Step 4
Attach the carbon fiber traction bars. Thanks to the trolley and the newly designed interface, the CF traction bars can be easily attached from the foot end by a single operator.

Detaching is just as easy as attaching. Thanks to the snap-in mechanism, a simple push with a finger releases the CF traction bars effortlessly.

4

Maquet Corin & Maquet Otesus
Focus on your patient while reducing your workload
Thanks to our leg plates, the patient remains securely positioned on the operating table throughout the procedure. This minimizes physical strain on the surgical team and protects the fracture from unnecessary stress. Every detail has been designed to ensure a smooth workflow.

Step 1 to 3

Workflow:
1 Position the patient on the setup equipped with leg plates.
2 Induce anesthesia. 3 Install the traction bars underneath the leg plates. 4 Position the patient’s legs in the traction boots. 5 Remove the leg plates. 6 Perform surgery. 7 Attach the leg plates and place the patient’s legs back on them. 8 Remove the carbon fiber traction bars.

Step 4 & 5 Step 6

5

Maquet Corin & Maquet Otesus
Easily convert your Maquet Corin or Otesus into specialized operating tables

Femur hook
Versatility during the procedure: The holder system is quick and easy to adjust to accommodate any patient anatomy.
Flexibility: Each femur hook includes components for both the left and right sides of the patient.
Ease of use: The motorized joint allows for smooth and precise adjustment of the femur hook.

Rotation of the leg
Leg alignment

Screw tensions device
Fast learning curve thanks to color-coded components and ergonomic design, allowing all adjustments to be made from the foot end.
· Slider: Enables quick leg positioning along the carbon fiber bars. Simply open the lever, slide to the desired position, adjust, and close the lever. The slider can be moved very close to the operating table, making it suitable even for pediatric procedures or hip surgeries following amputation.
· Traction: A crank mechanism allows easy application of traction up to 80 kg (~ 800 N). Fine-tuning and precise adjustments are also possible.
· Rotation: Any angle can be easily set using the star-shaped handle with an integrated degree indicator. Rotation can be locked or left free, allowing surgeons to work independently if needed.
· Clamping lever for ball joint: Enables full 360° leg alignment at the beginning of the procedure, thanks to the ball joint mechanism.
6

Movement for gross traction

Fine traction of the leg

Maquet Corin & Maquet Otesus
Easily convert your Maquet Corin or Otesus into specialized operating tables

Benefit from Maquet Corin smart features
· Tipping prevention ensures safe positioning and prevents tipping hazards, during longitudinal shift or OR table repositioning for instance.
· Collision detection: protects staff working near the OR table and nearby equipment, such as C-arms.
· Overload detection protects the OR table against structural damage with a warning when the load limit is reached or exceeded.

Traction Boot · Provides firm support for both foot and calf. · Extremely robust shell for maximum durability. · Available in two sizes: EU 32­37 and 37­45. · Compatible with both disposable and reusable inlays. · Made from skin-friendly materials for enhanced patient comfort.

7

Maquet Corin & Maquet Otesus
Technical data

15° 30°

45°45°
45°
45°

Manual movements Leg abduction Leg adduction Upwards Downwards

Traction bar 45°
45°

Traction bar with ball joint
45°
45°
15°
30°

Inlet B A
A

Radiolucency window (A)
Without longitudinal shift
With longitudinal shift

Maquet Corin 598 mm
up to 768 mm

Maquet Otesus 571 mm –

Inlet (B) * max. 30° max. 40°

*Depending on imaging device, longitudinal shift and the load capacity – these three determine how large is the angle of Inlet can be.

8

Maquet Corin & Maquet Otesus
Treatment for hip replacement with Direct Anterior Approach in supine position

Femur hook can be combined to facilitate minimal invasive procedure.
Thanks to the DAA bar and its high degree of mobility, the patient’s femur can be adjusted to any desired position.

13

10 12 6

7

5

1

3

4

8-9

Please note that only the essential accessories are shown here. We recommend checking the patient positioning as well as the accessories catalog for a complete configuration.

Basic configuration 1 – Maquet Corin OR Table Other configuration options with Maquet Otesus: Maquet Otesus mobile column Maquet Otesus stationary column Maquet Otesus table top Positioning specific accessories 2 – Traction adapter (not visible) 3 – Carbon fiber extension plate (1 hole) 4 – Traction bar with ball joint (x2) 5 – Screw tension device (x2) 6 – Femur hook, set 7 – Foot plate 8 – Traction boot 9 – Disposable inlay and mounting brackets General side rail accessories 10 – Arm rest 11 – Radial setting clamp (not visible) 12 – Arm support Positioning aids 13 – Oasis Elite supine head rest adult * manufactured by company Trulife ** manufactured by company Condor

7700.01XX 1160.01C0 1160.01D0 1160.01A0 1160.01B0 1160.10A0/B0/D0 1160.30A0/B0/D0
1003.72AC 1433.66BC 1007.40B0 1007.43A0 1433.42A0 1001.97A0 1003.75A0** 1003.76A0**
1002.49A0 1003.23C0 1001.6000
4006.21A0* 9

Maquet Corin & Maquet Otesus
Treatment for femur neck fracture with femur nailing

Back-friendly patient positioning and easy approach to the surgical site. Large radiolucent window of the hip joint area. Facilitating daily practice: easy adjustment of the operated leg with the Traction bar.

17

15

11

8

76

17

15 14

11

9+10

7

1-A 10

4

5-A

Maquet Corin

1-B

4

5-B

Maquet Otesus

Maquet Corin & Maquet Otesus
Treatment for femur neck fracture with femur nailing

Basic configuration 1-A – Maquet Corin OR Table 1-B – Maquet Otesus mobile column 2 – Pair of leg plates (not visible) Other configuration options with Maquet Otesus: Maquet Otesus stationary columns Maquet Otesus table top Positioning specific accessories 3 – Traction adapter (not visible) 4 – Carbon fiber extension plate with 3 holes 5-A – Traction bar 5-B – Traction bar with ball joint 6 – Short vertical adjustment 7 – Screw tension device 8 – Foot plate 9 – Traction Boot

7700.01XX 1160.01C0 or 1160.01D0
1007.42AC 1160.01A0 1160.01B0 1160.10A0/B0/D0 1160.30A0/B0/D0
1003.72AC 1433.66AC 1007.41B0 1007.40B0 1007.51B0 1007.43A0 1001.97A0 1003.75 A0**

10 – Disposable inlay and mounting brackets 11 – Leg holder 12 – Radial setting clamp for leg holder (not visible) 13 – Side rail extension (not visible)

1003.76 A0** 1001.65A0 1003.23A0 1004.91A0

General side rail accessories 14 – Arm support 15 – Arm rest 16 – Radial setting clamp for arm rest (not visible) Positioning aids 17 – Oasis Elite supine head rest adult

1001.6000 1002.49A0 1003.23A0
4006.21A0*

* manufactured by company Trulife ** manufactured by company Condor
Please note that only the essential accessories are shown here. We recommend checking the patient positioning and as well as the accessories catalog for a complete configuration.

11

Maquet Corin & Maquet Otesus
Treatment of hip joint by hip arthroscopy

Precise positioning. Enables a strong traction of up to 80 kg (~ 800 N). External rotation of the hip joint is quick and easy enabling surgeons to work independently.

12 11

6

5

18

16

9+10

1

74

Maquet Corin configuration with Traction bar with ball joint (1007.40B0) on the operated right leg.

12

8

14

Maquet Corin configuration with traction bar (1007.41B0) on the operated right leg.

Maquet Corin & Maquet Otesus
Treatment of hip joint by hip arthroscopy

Basic configuration 1 – Maquet Corin OR Table Other configuration options with Maquet Otesus: Maquet Otesus mobile column Maquet Otesus stationary column Maquet Otesus table top 2 – Pair of leg plates (not visible) Positioning specific accessories 3 – Traction adapter (not visible) 4 – Carbon fiber extension plate with 3 holes 5 – Short vertical adjustment 6 – Screw tension device (x2) 7 – Traction bar with ball joint 8 – Traction bar 9 – Traction boot 10 – Disposable inlay and mounting brackets

7700.01XX 1160.01C0 1160.01D0 1160.01A0 1160.01B0 1160.10A0/B0/D0 1160.30A0/B0/D0 1007.42AC
1003.72AC 1433.66AC 1007.51B0 1007.43A0 1007.40B0
1007.41B0
1003.75A0** 1003.76A0**

11 – Foot plate 12 – Support plate 13 – Radial setting clamp (not visible) 14 – Sliding clamp with side rail

1001.97A0 1007.45A0 1003.23C0 1007.44A0/F0

General side rail accessories 15 – Arm support (not visible) 16 – Arm rest 17 – Radial setting clamp (not visible) Positioning aids 18 – Oasis Elite supine head rest adult

1001.6000 1002.49A0 1003.23C0
4006.21A0*

* manufactured by company Trulife ** manufactured by company Condor
Please note that only the essential accessories are shown here. We recommend checking the patient positioning and as well as the accessories catalog for a complete configuration.

13

Maquet Corin & Maquet Otesus
Treatment for pelvic fracture in prone and supine

Perform pelvic surgery in prone position. Enables good approach to the acetabulum. Thanks to the traction frame combined with the traction clamp (1003.35A0) or with the traction stirrup clamp with rotation, the operated leg remains securely positioned throughout the procedure without the need for manual support. In the supine position, a greater distance between the countertraction post and the column facilitates improved inlet imaging.

18

21

10 9

5

20

19

11

12+13

6

1-A 16

17 15 8

7

Example of patient position for treatment of Pelvic fracture in prone position performed on Maquet Corin.

14

1-B

14

4

Example of patient position for treatment of Pelvic fracture in supine position performed on Maquet Otesus.

Maquet Corin & Maquet Otesus
Treatment for pelvic fracture in prone and supine

Basic configuration 1-A – Maquet Corin OR Table 1-B – Maquet Otesus mobile column Other configuration options with Maquet Otesus: Maquet Otesus stationary column Maquet Otesus table top 2 – Pair of leg plates (not visible) 1007.42AC Positioning specific accessories 3 – Traction adapter (not visible) 4 – Traction bar 5 – Short vertical adjustment 6 – Screw tension device (x2) 7 – Traction bar with ball joint 8 – Traction stirrup clamp with rotation 9 – Traction frame 10 – Traction stirrup 11 – Foot plate

7700.01XX 1160.01C0 1160.01D0 1160.01A0 1160.01B0 1160.10A0/B0/D0 1160.30A0/B0/D0
1003.72AC 1007.41B0 1007.51B0 1007.43A0 1007.40A0 1003.35A0 1007.49A0 Not a Getinge product 1001.97A0

12 – Traction boot 13 – Disposable inlay and mounting brackets 14 – Carbon fiber extension plate with 3 holes 15 – Support plate 16 – Radial setting clamp (not visible) 17 – Sliding clamp with side rail

1003.75A0** 1003.76A0** 1433.66AC 1007.45A0 1003.23C0 1007.44A0/F0

General side rail accessories 18 – Arm support (x2) 19 – Arm rest Positioning aids 20 – Oasis Elite supine head rest adult 21 – Oasis Elite Prone Head Rest, large

1001.6000 1002.49A0
4006.21A0* 4006.19A0*

* manufactured by company Trulife ** manufactured by company Condor
Please note that only the essential accessories are shown here. We recommend checking the patient positioning and as well as the accessories catalog for a complete configuration.

15

This information is intended for an international audience outside the US.

This information is aimed exclusively at healthcare professionals or other professional audiences and are for informational purposes only, is not exhaustive and therefore should not be relied upon as a replacement of the Instructions for Use, service manual or medical advice. Getinge shall bear no responsibility or liability for any action or omission of any party based upon this material, and reliance is solely at the user’s risk.

Any therapy, solution or product mentioned might not be available or allowed in your country. Information may not be copied or used, in whole or in part, without written permission by Getinge.

Manufacturer · Maquet GmbH · Kehler Str. 31 · 76437 Rastatt · Germany · info@getinge.com

© 2025 Getinge | Getinge and DMS-0011679 | All rights reserved.

are trademarks or registered trademarks of Getinge AB, its subsidiaries or affiliates.

Documents / Resources

GETINGE Corin and Otesus Operating Tables [pdf] Instruction Manual
Corin and Otesus Operating Tables, Otesus Operating Tables, Operating Tables, Tables

References

Leave a comment

Your email address will not be published. Required fields are marked *