GeoSIG GMS-xx Datastream Ethernet
Product Specifications
- Product Name: GMS-xx
- Connection: Ethernet (LAN)
- System Requirements: GeoDAS installed on Windows Computer
Product Usage Instructions:
Setup Datastream from GMS-xx Serial Console
- Connect to the serial console of your GMS-xx.
- Press ‘C’ to enter the configuration menu and press ‘C’ again to edit current configuration.
- Press ‘F’ and enter the number of output streams (1 stream per 3 channels).
- For a GMS-xx with 3 channels, enter 1 output stream.
- Press ‘J’ to enter Stream Parameters.
- Press ‘B’ until Stream type shows GSBU.
- Press ‘C’ to enter Port configuration.
- Press ‘A’ until Communication port shows TCP/IP.
- Press ‘C’ until Protocol shows TCP (Server).
- Press ‘E’ to enter the communication port (default is 4001).
- Only one stream with max. 3 channels can use the same port!
- A second stream would need to use a different port (e.g. 4002).
- Press Esc followed by ENTER and again Esc followed by ENTER to get back to the main menu.
- Press Esc to exit the menu.
- Press ‘C’ to save the configuration as current.
- In the main menu, press ‘R’ followed by Enter to restart the instrument.
- After the restart, the configuration changes are applied.
FAQ GMS-xx Setup Datastream Ethernet
Introduction
This procedure describes how to setup datastream on a GMS-xx through ethernet (LAN)
Required Tools
- GeoDAS installed on Windows Computer
- GMS-xx, connected via Ethernet
- Serial connection to console of GMS-xx http://www.geosig.com/files/FAQ_GMS-xx_How_to_Connect_Serial_Console_with_uCon.pdf
Setup Datastream from GMS-xx Serial Console
- Connect to the serial console of your GMS-xx
- Press C to enter the configuration menu and press C again to edit current configuration
- Press F and enter the number of output streams (1 stream per 3 channels)
- Means for a GMS-xx with 3 channels, you enter 1 output stream
- Press J to enter Stream Parameters
- Press B until Stream type shows GSBU
- Press C to enter Port configuration
- Press A until Communication port shows TCP/IP
- Press C until Protocol shows TCP (Server)
- Press E to enter the communication port (default is 4001)
Only one stream with max. 3 channels can use the same port! A second stream would need to use a different port (e.g. 4002) - Press Esc followed by ENTER and again Esc followed by ENTER to get back to the main menu
- Press Esc to exit the menu
- Press C to save the configuration as “current”
- In the main menu, press R followed by Enter to restart the instrument
- After the restart, the configuration changes are applied
Setup Datastream in GeoDAS
- In GeoDAS, open Settings-> Channels of Digitizers…
- Enter a name for the stream (3-letter code)
- Under Type, choose GeoSIG Packet Digitizer from the dropdown
- Tick Remote host IP address and port and enter the IP address of your GMS-xx and the port defined for the stream
- Click the button [Add/Modify]
- Tick the box Use channel parameters provided by the digitizer
- To add another stream, repeat from step 4.
- Make sure to use a different port for each stream!
- Click the button [OK]
- Confirm the appearing pop-up with [Yes]
- Restart GeoDAS