GENESIS 1070 Tray Mini Split Cable

Product Specifications
- Conductor Color Codes: Mini Split Cable
- Conductor Number
- Color
- 1 – Black
- 2 – White
- 3 – Red
- 4 – Green
- 5 – Brown
- 6 – Blue
- 7 – Orange
Construction
- Conductor: Bare Copper conductors forexcellent conductivity and low voltage drop
- Insulation: THHN
- Jacket: PVC
Applications
Installed in-wall without conduit in one- and two-family dwellings (2017 NEC and later units). In burial applications with or without conduit.
Sample Print Legend
| Part Number | Conductor Size (AWG) | Number of Conductors | Stranding | Insulation Thickness (in) | Jacket Thickness (in) | Nominal Diameter (in) | DC Resistance (Ohms/1000ft) | Weight (lbs/1000ft) |
|---|---|---|---|---|---|---|---|---|
| 1068 | 16 | 4 | 26-strand | 0.015 | 0.047 | 0.343 | 4.19 | 71.3 |
| 1069 | 14 | 3 | 7-strand | 0.015 | 0.047 | 0.335 | 2.62 | 75.0 |
| 1070 | 14 | 4 | 7-strand | 0.015 | 0.047 | 0.363 | 2.62 | 94.0 |
Product Usage Instructions
Indoor Installation without Conduit:
- Select the appropriate Mini Split Tray Cable based on your needs.
- Carefully route the cable through the designated area for installation.
- Connect the conductors to the respective terminals following the provided color codes.
- Safely secure the cable in place to prevent any accidental damage.
Burial Application:
- Determine if conduit is required based on your specific installation requirements.
- If using a conduit, install it following standard practices.
- If burying the cable directly, ensure proper depth and protection against environmental factors.
- Maintain proper grounding and connections as per local electrical codes.
Construction

- Conductor: Bare Copper conductors for excellent conductivity and low voltage drop
- Insulation: THHN
- Jacket: PVC
Applications
- Installed in-wall without conduit in one- and two-family dwelling (2017 NEC and later units)
- In burial applications with or without conduit
Specifications
- UL 1277 – Electrical Power and Control Tray Cables
- Direct Burial Rated
- Sunlight Resistant Rated
- REACH/RoHS Compliant
- Rated for 600 Volts
- Rated for -20°C to 90°C Dry/75°C Wet
Color Coding

Mini Split Cable, Tray
|
Number of Conductors |
Stranding |
Insulation Thickness (in) |
Jacket Thickness (in) |
Nominal Diameter (in) | DC Resistance (Ohms/1000ft at 20°C) |
Weight (lbs/1000ft) |
| 4 | 26-strand | 0.015 | 0.047 | 0.343 | 4.19 | 71.3 |
| 3 | 7-strand | 0.015 | 0.047 | 0.335 | 2.62 | 75.0 |
| 4 | 7-strand | 0.015 | 0.047 | 0.363 | 2.62 | 94.0 |
ABOUT COMPANY
- Genesis Cable
- 7701 95th Street
- Pleasant Prairie, WI 53158
- Office: 800.222.0060
- www.genesiscable.com
Frequently Asked Questions (FAQ)
Can Mini Split Tray Cables be used outdoors?
Yes, Mini Split Tray Cables are designed to accommodate both indoor and outdoor installations, including harsh and wet environments.
Are the cables sunlight resistant?
Yes, these cables feature sunlight resistance, making them suitable for outdoor use where exposure to sunlight is a concern.
How do I determine the appropriate cable size for my installation?
Refer to the provided sample print legend which includes details such as conductor size, stranding, insulation thickness, and more to select the right cable for your needs.
What are the recommended installation practices for burying Mini Split Tray Cables?
When burying the cables, ensure proper depth, protection against moisture, and compliance with local electrical codes to maintain safety and performance.
Documents / Resources
![]() | 1070 Tray Mini Split Cable |
References
- genesiscable.comwww.genesiscable.com
- User Manualmanual.tools
Published: February 22, 2025
Updated: February 23, 2025