Geizhals ECS2800 Static Content
Specifications
- CS Module Model: ECS2800
- CM Module Model: CM2800
- CS2800 Specifications:
- Dimensions (L*W*H) (mm)
- Weight (Kg)
- Communication interfaces
- CM2800 Specifications:
- Model NO.
- Max. charge/discharge current (A)
- Humidity (%)
- Normal voltage (V)
- Normal capacity (Ah)
- Normal energy (kWh)
- Battery voltage range (V)
- Max. Continuous discharge/charge current (A) (CC-CV)
- Standard charging current (A)
- Constant current and voltage charging cut-off
Product Usage Instructions
Installation
Qualified personnel should perform the installation of the high voltage battery system. Ensure that all safety precautions are followed during installation.
Commissioning
After installation, a qualified technician must commission the system. Verify that all connections are secure and the system is
functioning properly.
Maintenance
Regular maintenance checks should be conducted by authorized technicians to ensure the proper functioning of the battery system. Follow the maintenance schedule outlined in the user manual.
Troubleshooting
If any issues arise with the battery system, refer to the troubleshooting section of the user manual. Only authorized technicians should attempt to troubleshoot and repair the system.
FAQ
- Q: Who should handle maintenance and installation of the battery system?
A: Maintenance and installation tasks should be carried out by authorized technicians who have familiarized themselves with the contents of the user manual. - Q: What is the maximum configuration for the battery system?
A: The system can consist of at least 1 CM+1 CS and up to 1 CM+6 CS. In the US market, only ECS4000 can be used with a maximum configuration of 1 CM+4 CS.
User Manual
In order to prevent improper operation before use, please carefully read this manual.
Introduction
The document describes the installation, commissioning, maintenance and troubleshooting of the following high voltage battery listed below.
ECS
Note: ECS = CM+CS
The battery chemistry of these products is Lithium Iron Phosphate. This manual is designed for qualified personnel only. The tasks described in this document should be performed by authorized and qualified technicians only.
After Installation the Installer must explain the user manual to the end user.
Symbols
Safety
Any work on the Batteries should be handled by authorized technicians and hence it is understood that the technicians should familiarize themselves with the contents of this manual before any maintenance or installation is carried out on the system.
Handling
- Do not expose battery to open flame.
- Do not place the product under direct sunlight.
- Do not place the product near flammable materials. It may lead to fire or explosion in case of accident.
- Store in a cool and dry place with ample ventilation.
- Do not store the product near water sources.
- Store the product on a flat surface.
- Store the product out of reach of children and animals.
- Do not damage the unit by dropping, deforming, impacting, cutting or penetrating with a sharp object. It may cause leakage of electrolyte or fire.
- Do not touch any liquid spilled from the product. There is a risk of electric shock or damage to skin.
- Always handle the battery wearing the insulated gloves.
- Do not step on the product or place any foreign objects on it. This can result in damage.
- Do not charge or discharge damaged battery.
- Do not store the battery near water sources.
Installation
- Do not connect the ECS to inverter conductors or Photo-Voltaic conductors. This will damage the battery and may result in explosion.
- After unpacking, please check the product for damages and missing parts.
- Make sure that the inverter and battery is completely turned off before commencing installation.
- Do not interchange the positive and negative terminals of the battery.
- Ensure that there is no short circuit of the terminals or with any external device.
- Do not exceed the battery voltage rating of the inverter.
- Do not connect the battery to any incompatible inverter.
- Do not connect different battery types together.
- Please ensure that all the batteries are grounded properly.
- Do not open the battery to repair or disassemble. Only Fox ESS is allowed to carry out any such repairs.
- In case of fire, use only dry powder fire extinguisher. Liquid extinguishers should not be used.
- Install the batteries only inside approved Fox ESS enclosure. Installing the battery anywhere outside is strictly forbidden.
- Do not install the battery near water sources or places where the battery can get wet.
- Do not use battery in high static environment where the protection device might be damaged.
- Do not install with other batteries or cells.
- Please ensure on installation site that the deviation of voltages between new batteries and every single present battery is less than 0.5V.
- Please ensure the new batteries mounted on-site comply to the warranty scope or have ever been re-charged within 5 months; on top of that, please make sure the SOC of present battery system onsite is 50%±5%.
Response to Emergency Situations
The batteries comprise of multiple batteries connected in series. It is designed to prevent hazards or failures. However, Fox ESS cannot guarantee their absolute safety.
Under exposure to the internal materials of the battery the following recommendations should be carried out by the user.
- If there has been inhalation, please leave the contaminated area immediately and seek medical attention.
- If there has been contact with eyes, rinse the eyes with running water for 15 minutes and seek medical attention immediately.
- If there has been contact with the skin, wash the contacted area with soap thoroughly and seek medical attention immediately.
- If there has been ingestion, induce vomiting and seek medical attention.
Fire Situation
In situations where the battery is on fire, if it is safe to do so, disconnect the battery pack by turn off the circuit breaker to shut off the power to the system. Use FM-200 or Co2 fire extinguisher for the battery and an ABC fire extinguisher for the other parts of the system. Under any fire situation, please evacuate the people from the building immediately before trying to extinguish it.
Water Situation
The battery modules are not water resistant. Hence care should be taken not to get it wet. If you find the battery completely or partially submerged in water do not try to open. Contact an authorized personnel or Fox ESS for further instructions.
Product Information
- CS is the battery module, and CM includes system controller and battery module;
- CM contains the controller of the entire system, so each system must have one CM;
- Our system consists of at least 1 CM+1 CS and up to 1 CM+6 CS.
- Only ECS4000 can be used in the US market and the max battery system consists of 1CM+4CS. 5.1 ECS2800 Specifications
CS2800 Specifications
Specifications for CS | |
Model NO. | CS2800 |
Max. charge/discharge current (A) | 48 |
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -10~35 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 48 |
Normal energy (kWh) | 2.76 |
Battery voltage range (V) | 52.2~66.2 |
Max. Continuous discharge/charge current (A) | 48/48 |
(CC-CV) Standard charging current (A) | 24 |
Constant current and voltage charging cut-off current (A) | 3 |
Peak discharge current (60s) (A) | 65 |
Dimensions (L*W*H) (mm) | 570*380*163 |
Weight (Kg) | 31±1 |
Communication interfaces | CAN |
CM2800 Specifications
Specifications for CM | |
Model NO. | CM2800 |
Max. charge/discharge current (A) | 48 |
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -10~35 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 48 |
Normal energy (kWh) | 2.76 |
Battery voltage range (V) | 52.2~66.2 |
Max. Continuous discharge/charge current (A) | 48/48 |
(CC-CV) Standard charging current (A) | 24 |
Constant current and voltage charging cut-off current (A) | 3 |
Peak discharge current (60s) (A) | 65 |
Dimensions (L*W*H) (mm) | 570*380*178 |
Weight (Kg) | 35±1 |
Communication interfaces | CAN |
Battery System Specifications for ECS2800
Model No. | ECS2800-H2 | ECS2800-H3 | ECS2800-H4 | ECS2800-H5 | ECS2800-H6 | ECS2800-H7 | |||
Technical Properties |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||
Battery designation* |
IFpP/21/115/ 103/[(2P18S)
2S]M/-10+50 /90 |
IFpP/21/115/ 103/[(2P18S)
3S]M/-10+50 /90 |
IFpP/21/115/ 103/[(2P18S)
4S]M/-10+50 /90 |
IFpP/21/115/ 103/[(2P18S)
5S]M/-10+50 /90 |
IFpP/21/115/ 103/[(2P18S)
6S]M/-10+50 /90 |
IFpP/21/115/ 103/[(2P18S)
7S]M/-10+50 /90 |
|||
The number of batteries | 1CM+1CS | 1CM+2CS | 1CM+3CS | 1CM+4CS | 1CM+5CS | 1CM+6CS | |||
Normal voltage (V) | 115.2 | 172.8 | 230.4 | 288 | 345.6 | 403.2 | |||
Normal capacity (Ah) | 48 | 48 | 48 | 48 | 48 | 48 | |||
Normal energy (kWh) | 5.53 | 8.29 | 11.06 | 13.82 | 16.59 | 19.35 | |||
Battery voltage range (V) | 104.4~132.4 | 156.6~198.7 | 208.8~264.9 | 261.0~331.2 | 313.2~397.4 | 365.4~463.6 | |||
Max. charge/discharge
current (A) |
48/48 |
||||||||
(CC-CV) Standard charging current (A) | 24 | ||||||||
Constant current and constant voltage charging cut-off current (A) |
3 |
||||||||
Peak discharge Current (60s) (A) | 65 | ||||||||
Storage temperature (°C) | -10~35 | ||||||||
Operating Temperature range
(°C) |
Charge: 0~55 Discharge: -10~55 | ||||||||
Discharge capacity (Ah) | 36@-20±2°C @1C
48@25±2°C @0.5C 48@55±2°C @0.5C |
||||||||
Cycle life | ≥6000 @25°C @ 70%SOH | ||||||||
Ingress protection | IP65 | ||||||||
Protective class | Class Ⅰ | ||||||||
Dimensions (L*W*H)(mm) |
570*380*366 |
570*380*494 |
570*380*622 |
570*380*750 |
570*380*878 |
570*380*1006 |
|||
Weight (kg) | 69.6 | 100.1 | 130.6 | 161.1 | 191.6 | 222.1 | |||
Communication interfaces | CAN | ||||||||
Specifications for CS | |||||||||
Model NO. | CS2900 | ||||||||
Max. charge/discharge current (A) | 50 |
ECS2900 Specifications
CS2900 Specifications
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -20~55 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 50 |
Normal energy (kWh) | 2.88 |
Battery voltage range (V) | 48.6~65.7 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 25 |
Constant current and voltage charging cut-off current (A) | 2.5 |
Peak discharge current (60s) (A) | 65 |
Altitude (m) | ≤2000 |
Dimensions (L*W*H) (mm) | 570*380*155 |
Weight (Kg) | 31±1 |
Communication interfaces | CAN |
CM2900 Specifications
Specifications for CM | |
Model NO. | CM2900 |
Max. charge/discharge current (A) | 50 |
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -20~55 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 50 |
Normal energy (kWh) | 2.88 |
Battery voltage range (V) | 48.6~65.7 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 25 |
Constant current and voltage charging cut-off current (A) | 2.5 |
Peak discharge current (60s) (A) | 65 |
Altitude (m) | ≤2000 |
Dimensions (L*W*H) (mm) | 570*380*170 |
Weight (Kg) | 35±1 |
Communication interfaces | CAN |
Battery System Specifications for ECS2900
Specifications for ECS2900 | ||||||
Model No. | ECS2900-H2 | ECS2900-H3 | ECS2900-H4 | ECS2900-H5 | ECS2900-H6 | ECS2900-H7 |
Technical Properties |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||
Battery designation* |
IFpP/41/150/ 102/[(18S)2S
]M/-10+50/90 |
IFpP/41/150/ 102/[(18S)3S
]M/-10+50/90 |
IFpP/41/150/ 102/[(18S)4S
]M/-10+50/90 |
IFpP/41/150/ 102/[(18S)5S
]M/-10+50/90 |
IFpP/41/150/ 102/[(18S)6S
]M/-10+50/90 |
IFpP/41/150/ 102/[(18S)7S
]M/-10+50/90 |
|||
The number of batteries | 1CM+1CS | 1CM+2CS | 1CM+3CS | 1CM+4CS | 1CM+5CS | 1CM+6CS | |||
Normal voltage (V) | 115.2 | 172.8 | 230.4 | 288 | 345.6 | 403.2 | |||
Normal capacity (Ah) | 50 | 50 | 50 | 50 | 50 | 50 | |||
Normal energy (kWh) | 5.76 | 8.64 | 11.52 | 14.4 | 17.28 | 20.16 | |||
Battery voltage range (V) | 97.2~131.4 | 145.8~197.1 | 194.4~262.8 | 243.0~328.5 | 291.6~394.2 | 340.2~459.9 | |||
Max. charge/discharge current (A) |
50/50 |
||||||||
(CC-CV) Standard charging current (A) | 25 | ||||||||
Constant current and constant voltage charging cut-off
current (A) |
2.5 |
||||||||
Peak discharge Current (60s) (A) | 65 | ||||||||
Storage temperature (°C) | -20~55 | ||||||||
Operating Temperature range (°C) | Charge: 0~55 Discharge: -10~55 | ||||||||
Discharge capacity (Ah) | 35@-10±2°C @0.5C
50@25±2°C @0.5C 47@55±2°C @0.5C |
||||||||
Cycle life | ≥6000 @25°C @ 70%SOH | ||||||||
Ingress protection | IP65 | ||||||||
Protective class | Class Ⅰ | ||||||||
Dimensions (L*W*H) (mm) |
570*380*350 |
570*380*470 |
570*380*590 |
570*380*710 |
570*380*830 |
570*380*950 |
|||
Weight (kg) | 71.1 | 102.9 | 134.7 | 166.5 | 198.3 | 230.1 | |||
Communication interfaces | CAN | ||||||||
Specifications for CS | |||||||||
Model NO. | CS4000 | ||||||||
Max. charge/discharge current (A) | 50 |
ECS4000 Specifications
CS4000 Specifications
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -20~55 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 69 |
Normal energy (kWh) | 3.97 |
Battery voltage range (V) | 48.6~65.7 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 35 |
Constant current and voltage charging cut-off current (A) | 3.5 |
Peak discharge current (60s) (A) | 65 |
Dimensions (L*W*H) (mm) | 570*380*155 |
Weight (Kg) | 35±1 |
Communication interfaces | CAN |
CM4000 Specifications
Specifications for CM | |
Model NO. | CM4000 |
Max. charge/discharge current (A) | 50 |
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -20~55 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 69 |
Normal energy (kWh) | 3.97 |
Battery voltage range (V) | 48.6~65.7 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 35 |
Constant current and voltage charging cut-off current (A) | 3.5 |
Peak discharge current (60s) (A) | 65 |
Dimensions (L*W*H) (mm) | 570*380*170 |
Weight (Kg) | 39±1 |
Communication interfaces | CAN |
Battery System Specifications for ECS4000
Specifications for ECS4000 | ||||||
Model No. | ECS4000-H2 | ECS4000-H3 | ECS4000-H4 | ECS4000-H5 | ECS4000-H6 | ECS4000-H7 |
Technical Properties |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||
Battery designation* |
IFpP42/151/1 08/[(18S)2S] E/-10+50/90 | IFpP42/151/1 08/[(18S)3S] E/-10+50/90 | IFpP42/151/1 08/[(18S)4S] E/-10+50/90 | IFpP42/151/1 08/[(18S)5S] E/-10+50/90 | IFpP42/151/1 08/[(18S)6S] E/-10+50/90 | IFpP42/151/1 08/[(18S)7S] E/-10+50/90 | |||
The number of batteries | 1CM+1CS | 1CM+2CS | 1CM+3CS | 1CM+4CS | 1CM+5CS | 1CM+6CS | |||
Normal voltage (V) | 115.2 | 172.8 | 230.4 | 288 | 345.6 | 403.2 | |||
Normal capacity (Ah) | 69 | 69 | 69 | 69 | 69 | 69 | |||
Normal energy (kWh) | 7.95 | 11.92 | 15.90 | 19.87 | 23.85 | 27.82 | |||
Battery voltage range (V) | 97.2~131.4 | 145.8~197.1 | 194.4~262.8 | 243.0~328.5 | 291.6~394.2 | 340.2~459.9 | |||
Max. charge/discharge current (A) | 50/50 | ||||||||
(CC-CV) Standard charging current (A) | 35 | ||||||||
Constant current and constant voltage charging cut-off current
(A) |
3.5 |
||||||||
Peak discharge Current (60s) (A) | 65 | ||||||||
Storage temperature (°C) | -20~55 | ||||||||
Operating Temperature range (°C) | Charge: 0~55 Discharge: -10~55 | ||||||||
Discharge capacity (Ah) | 55@-20±2°C @0.5C
69@25±2°C @0.5C 69@55±2°C @0.5C |
||||||||
Cycle life | ≥6000 @25°C @ 70%SOH | ||||||||
Ingress protection | IP65 | ||||||||
Protective class | Class Ⅰ | ||||||||
Dimensions (L*W*H) (mm) |
570*380*350 |
570*380*470 |
570*380*590 |
570*380*710 |
570*380*830 |
570*380*950 |
|||
Weight (kg) | 75.5 | 110.5 | 145.5 | 180.5 | 215.5 | 250.5 | |||
Communication interfaces | CAN | ||||||||
Specifications for CS | |||||||||
Model NO. | CS4100 | ||||||||
Max. charge/discharge current (A) | 50 | ||||||||
Operating temperature (°C) | -10~55 |
ECS4100 Specifications
CS4100 Specifications
Storage temperature (°C) | -20~55 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 70 |
Normal energy (kWh) | 4.03 |
Battery voltage range (V) | 48.6~65.7 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 35 |
Constant current and voltage charging cut-off current (A) | 3.5 |
Peak discharge current (60s) (A) | 65 |
Dimensions (L*W*H) (mm) | 570*380*155 |
Weight (Kg) | 35±1 |
Communication interfaces | RS485 |
CM4100 Specifications
Specifications for CM | |
Model NO. | CM4100 |
Max. charge/discharge current (A) | 50 |
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -20~55 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 70 |
Normal energy (kWh) | 4.03 |
Battery voltage range (V) | 48.6~65.7 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 35 |
Constant current and voltage charging cut-off current (A) | 3.5 |
Peak discharge current (60s) (A) | 65 |
Dimensions (L*W*H) (mm) | 570*380*170 |
Weight (Kg) | 39±1 |
Communication interfaces | CAN/RS485 |
Battery System Specifications for ECS4100
Specifications for ECS4100 | ||||||
Model No. | ECS4100-H2 | ECS4100-H3 | ECS4100-H4 | ECS4100-H5 | ECS4100-H6 | ECS4100-H7 |
Technical Properties |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||
Battery designation* |
IFpP42/151/1 08/[(18S)2S] E/-10+50/90 | IFpP42/151/1 08/[(18S)3S] E/-10+50/90 | IFpP42/151/1 08/[(18S)4S] E/-10+50/90 | IFpP42/151/1 08/[(18S)5S] E/-10+50/90 | IFpP42/151/1 08/[(18S)6S] E/-10+50/90 | IFpP42/151/1 08/[(18S)7S] E/-10+50/90 | |||
The number of batteries | 1CM+1CS | 1CM+2CS | 1CM+3CS | 1CM+4CS | 1CM+5CS | 1CM+6CS | |||
Normal voltage (V) | 115.2 | 172.8 | 230.4 | 288 | 345.6 | 403.2 | |||
Normal capacity (Ah) | 70 | 70 | 70 | 70 | 70 | 70 | |||
Normal energy (kWh) | 8.06 | 12.09 | 16.12 | 20.15 | 24.18 | 28.21 | |||
Battery voltage range (V) | 97.2~131.4 | 145.8~197.1 | 194.4~262.8 | 243.0~328.5 | 291.6~394.2 | 340.2~459.9 | |||
Max. charge/discharge current (A) | 50/50 | ||||||||
(CC-CV) Standard charging current (A) | 35 | ||||||||
Constant current and constant voltage charging cut-off current
(A) |
3.5 |
||||||||
Peak discharge Current (60s) (A) | 65 | ||||||||
Storage temperature (°C) | -20~55 | ||||||||
Operating Temperature range (°C) | Charge: 0~55 Discharge: -10~55 | ||||||||
Discharge capacity (Ah) | 61@-20±2°C @0.5C
70@25±2°C @0.5C 70@55±2°C @0.5C |
||||||||
Cycle life | ≥6000 @25°C @ 70%SOH | ||||||||
Ingress protection | IP65 | ||||||||
Protective class | Class Ⅰ | ||||||||
Dimensions (L*W*H) (mm) |
570*380*350 |
570*380*470 |
570*380*590 |
570*380*710 |
570*380*830 |
570*380*950 |
|||
Weight (kg) | 75.5 | 110.5 | 145.5 | 180.5 | 215.5 | 250.5 | |||
Communication interfaces | CAN | ||||||||
Specifications for CS | |||||||||
Model NO. | CS4300H |
ECS4300H Specifications
CS4300H Specifications
Max. charge/discharge current (A) | 50 |
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -20~55 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 72 |
Normal energy (kWh) | 4.14 |
Battery voltage range (V) | 48.6~65.7 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 35 |
Constant current and voltage charging cut-off current (A) | 3.5 |
Peak discharge current (60s) (A) | 65 |
Altitude (m) | ≤2000 |
Dimensions (L*W*H) (mm) | 570*380*163 |
Weight (Kg) | 37±1 |
Communication interfaces | CAN |
CM4300H Specifications
Specifications for CM | |
Model NO. | CM4300H |
Max. charge/discharge current (A) | 50 |
Operating temperature (°C) | -10~55 |
Storage temperature (°C) | -20~55 |
Humidity (%) | 5~95 |
Normal voltage (V) | 57.6 |
Normal capacity (Ah) | 72 |
Normal energy (kWh) | 4.14 |
Battery voltage range (V) | 48.6~65.7 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 35 |
Constant current and voltage charging cut-off current (A) | 3.5 |
Peak discharge current (60s) (A) | 65 |
Altitude (m) | ≤2000 |
Dimensions (L*W*H) (mm) | 570*380*178 |
Weight (Kg) | 40±1 |
Communication interfaces | CAN |
Battery System Specifications for ECS4300H
Specifications for ECS4300H | ||||||
Model No. | ECS4300H-H2 | ECS4300H-H3 | ECS4300H-H4 | ECS4300H-H5 | ECS4300H-H6 | ECS4300H-H7 |
Technical Properties |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||
Battery designation* |
IFpP/41/150/ 112/[(18S)2S] E/-10+50/90 | IFpP/41/150/ 112/[(18S)3S] E/-10+50/90 | IFpP/41/150/ 112/[(18S)4S] E/-10+50/90 | IFpP/41/150/ 112/[(18S)5S]E
/-10+50/90 |
IFpP/41/150/ 112/[(18S)6S]E
/-10+50/90 |
IFpP/41/150/ 112/[(18S)7S]E
/-10+50/90 |
|||
The number of batteries | 1CM+1CS | 1CM+2CS | 1CM+3CS | 1CM+4CS | 1CM+5CS | 1CM+6CS | |||
Normal voltage (V) | 115.2 | 172.8 | 230.4 | 288 | 345.6 | 403.2 | |||
Normal capacity (Ah) | 72 | 72 | 72 | 72 | 72 | 72 | |||
Normal energy (kWh) | 8.29 | 12.44 | 16.59 | 20.74 | 24.88 | 29.03 | |||
Battery voltage range (V) | 97.2~131.4 | 145.8~197.1 | 194.4~262.8 | 243.0~328.5 | 291.6~394.2 | 340.2~459.9 | |||
Max. charge/discharge current (A) | 50/50 | ||||||||
(CC-CV) Standard charging current (A) | 35 | ||||||||
Constant current and constant voltage charging cut-off current
(A) |
3.5 |
||||||||
Peak discharge Current (60s) (A) | 65 | ||||||||
Storage temperature (°C) | -20~55 | ||||||||
Operating Temperature range (°C) | Charge: 0~55 Discharge: -10~55 | ||||||||
Discharge capacity (Ah) | 50@-10±2°C @0.5C
72@25±2°C @0.5C 72@55±2°C @0.5C |
||||||||
Cycle life | ≥6000 @25°C @ 70%SOH | ||||||||
Ingress protection | IP65 | ||||||||
Protective class | Class Ⅰ | ||||||||
Dimensions (L*W*H) (mm) |
570*380*366 |
570*380*494 |
570*380*622 |
570*380*750 |
570*380*878 |
570*380*1006 |
|||
Weight (kg) | 78.5 | 115.5 | 152.5 | 189.5 | 226.5 | 263.5 | |||
Communication interfaces | CAN | ||||||||
Specifications for CS | |||||||||
Model NO. | CS4800 | ||||||||
Max. charge/discharge current (A) | 50 | ||||||||
Operating temperature (°C) | Charge: 0~55 |
ECS4800 Specifications
CS4800 Specifications
Discharge: -10~55 | |
Storage temperature (°C) | -10~35 |
Humidity (%) | 5~95 |
Normal voltage (V) | 44.8 |
Normal capacity (Ah) | 104 |
Normal energy (kWh) | 4.66 |
Battery voltage range (V) | 40.6~51.5 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 30 |
Constant current and voltage charging cut-off current (A) | 5.3 |
Peak discharge current (60s) (A) | 65 |
Dimensions (L*W*H) (mm) | 570*380*172 |
Weight (Kg) | 39±1 |
Communication interfaces | CAN |
CM4800 Specifications
Specifications for CM | |
Model NO. | CM4800 |
Max. charge/discharge current (A) | 50 |
Operating temperature (°C) | Charge: 0~55 Discharge: -10~55 |
Storage temperature (°C) | -10~35 |
Humidity (%) | 5~95 |
Normal voltage (V) | 44.8 |
Normal capacity (Ah) | 104 |
Normal energy (kWh) | 4.66 |
Battery voltage range (V) | 40.6~51.5 |
Max. Continuous discharge/charge current (A) | 50/50 |
(CC-CV) Standard charging current (A) | 30 |
Constant current and voltage charging cut-off current (A) | 5.3 |
Peak discharge current (60s) (A) | 65 |
Dimensions (L*W*H) (mm) | 570*380*188 |
Weight (Kg) | 43±1 |
Communication interfaces | CAN |
Battery System Specifications for ECS4800
Specifications for ECS4800 | ||||||
Model No. | ECS4800-H2 | ECS4800-H3 | ECS4800-H4 | ECS4800-H5 | ECS4800-H6 | ECS4800-H7 |
Note:The battery designation is a series of numbers that represent the battery’s positive and negative electrode types, structure and size, charge and discharge rate, and operating temperature range.
Product Features
Battery System Features
The batteries have been fitted with multiple protection systems to ensure the safe operation of the system. Some of the protection system includes:
- Inverter interface protection: Over voltage, Over current, External Short Circuit, Reverse Polarity, Ground Fault, Over Temp, In rush current
- Battery Protection: Internal Short Circuit, Over voltage, over current, over temp, Under voltage The battery system contains the following Interface to allow it to connect and operate efficiently.
CS Features:
- interface:
CM Features:
- interface:
CM Features:
- interface:
- DC switch
- Power switch, battery charge and discharge circuit switch.
- DC OUT +
- Connect bat + of inverter.
- DC OUT –
- Connect bat – of inverter.
- POWER switches
- System power on switch, press this switch, the system starts to work.
- B-Start switches
- After power on, press this button for 5s.
- BMS Status LED and SOC LED
- LED display specific alarm information and battery system power.
- Operating status LED
- This LED is used to indicate if the battery is operating effectively. A green light on this LED means the battery is ON and operating normally. If the battery is operating failure, a red light on this LED means the battery is operating abnormally.
Installation
Items in the package
Please check if following items are including with the package:
For CS
For CM
For CM4000(US only)
MNOP
No. | Items | No. | Items |
C | Mounting screw pack | J | Expansion tube*2 & Expansion screw*2 |
D | Fixing bracket | K | Waterproof cover |
E | Footstand | L | RJ45 |
F | Communication cable (BMS-Inverter) | M | Junction box (US only) |
G | Grounding cable | N | PLUG*2 (US only) |
H | DC output cable | O | Grounding cable (US only) |
I | Installation guide | P | DC out cable (US only) |
Clearance
Note:Make sure to leave a space of at least 300 mm. A clearance of at least 300 mm must be Ieft around the battery pack for proper cooling.
Note: Make sure that the battery pack is always exposed to the ambient air. The battery pack is cooled by natural convection. If the battery pack is entirely or partially covered or shielded, it may cause the battery pack to stop operating.
Tools
The following tools will be required to install CM and CS.
Installation Steps
- Step 1: Install a CS with four footstand (Item E) and place it on the ground and adjust it to the level. After installing the footstand, use a track level bar to confirm the level. Insert the waterproof cover(Item K) into the bottom of the battery and lock it in place with the clip.
- Step 2: Place the against the wall. Note: Please make Status LED is on your you facing the battery 20mm sure the Operating left handside when model.
- Step 3: Stack the batteries one by one.
- Step 4: Place the two fixing brackets (Item D) close to the wall and install them on both sides of the battery.
Step 5: Mark the wall through the bracket hole.
- Step 6: Punch after removing the CM. Drill holes with electric drill, make sure the holes are at least 50mm deep, and then tighten the expansion tubes (Item J).
- Step 7: After stacking CM again, fix the battery on the wall.
- Step 8: Fix the mounting screw packs (Item C) on both sides of the battery, the installation is over.
Note: Please make sure each system including 1 CM and 1 CS. CS less than 6(1~6) pieces:
For CM4000(US only):
Note: Please make sure each system including 1 CM and 1 CS. CS less than 4(1~4) pieces: Please refer to the video for the installation of the junction box and the cable gland.
For CM4000(US only):
Wiring Steps
- Connect the inverter to make sure the wiring position is correct, as shown in the figure below.
Note: Inverter wiring refer to the inverter user manual.
For outdoor use,please use item L and proceed as follows
Connection steps:
- Step 1: Prepare a standard network cable and cable connector, then insert the network cable through the cable connector.
Step 2: Crimp the cable with a Rj45 plug which is inside of the cable connector.
If the usage is indoor, please use item F-
Step 3: Insert the cable connector into BMS port at the bottom of inverter and screw it tightly.
- Connect the grounding cable to ensure that all batteries are grounded. Wiring shall be connected in the sequence as shown in below.
- Connect the grounding cable to ensure that all batteries are grounded. Wiring shall be connected in the sequence as shown in below.
Note:
Make sure that the power cable connected to the battery is connected vertically and that the vertical length is greater than 30 cm. If the cable is bent close to the terminals, it may cause poor line contact and result in burnt terminals.
System Start up
- When the grid connected system is started, the inverter should be turned on first to avoid the current pulse of the inverter increasing to the battery pack.
- All installation and operation must comply with local electrical standards.
- Check all power cables and communication cables carefully.
Turn on the POWER switch
- Turn on DC switch and press the POWER switch, firstly Mater LED will light up once, and then the BMS Status LED will light up for 0.5s,Operating Status LED will light up for 1s at the same time,it means that the system works normally.
8. Commissioning
The operating status light on the left side of the battery pack shows its working status.
For CS
Green LED | Red LED | Batteries Status |
On for 0.5s, Off for 0.5s | On for 0.5s, Off for 0.5s | Runing in boot |
On for 0.1s, Off for 0.1s | On for 0.1s, Off for 0.1s | Upgrading |
On for 1s, Off for 1s | Off | Normal Working |
Off | On for 1s, Off for 1s | Alarm |
For CM
Remark:
- LED flash display (on: 0.5s, off: 0.5s)
- LED flash display (on: 0.5s, off: 0.5s)
Exclusion
The warranty shall not cover the defects caused by normal wear and tear, inadequate maintenance, handling, storage faulty repair, modifications to the battery or pack by a third party other than Fox ESS or Fox ESS agent, failure to observe the product specification provided herein or improper use or installation, including but not limited to the following.
- Damage during transport or storage.
- Incorrect Installation of battery into pack or maintenance.
- Use of battery pr pack in an inappropriate environment.
- Improper, inadequate, or incorrect charge, discharge or production circuit other than stipulated herein.
- Incorrect use or inappropriate use.
- Insufficient ventilation.
- Ignoring applicable safety warnings and instructions.
- Altering or attempted repairs y unauthorized personnel.
- In case of force majeure (ex: lightning, storm, flood, fire, earthquake, etc.).
- There are no warranties implied or express other than those stipulated herein. Fox ESS or Fox ESS shall not be liable for any consequential or indirect damages arising or in connection with the product specification, battery or pack.
Troubleshooting and Maintenance
Maintenance
- Regularly check whether the service environment of the battery meets the requirements, and the installation position should be far away from the heat source.
- The battery module should be stored in an environment with a temperature range between -20℃-
+ 55℃, and charged regularly according to the table below with no more than 0.5 C(A C-rate is a measure of the rate at which a battery is discharged relative to its maximum capacity.) to the SOC of 50% after a long time of storage.
Storage environment temperature | Relative humidity of the storage environment | Storage time | SOC |
Below -20℃ | / | Not allowed | / |
-20~35℃ | 5%~70% | ≤ 6 months | 20%≤SOC≤60% |
35~55℃ | 5%~70% | ≤ 3 months | 20%≤SOC≤60% |
Above 55℃ | / | Not allowed | / |
NOTICE
Damage to the system due to under voltages
- Charge the over-discharged system within seven days when the temperature is above 25℃.
- Charge the over-discharged system within seven days when the temperature is below 25℃.
- Regularly check whether the battery and its supporting terminals, connecting cables and indicator lights are normal.
Troubleshooting
When the red / green LED on the panel is flashing or normally on, it does not mean that the CS is abnormal, it may be just an alarm or protection. Please check the ‘LED status indicators’ in chapter 7 for the detailed faulty definition before any trouble-shooting steps. In general, the alarm indication is normal without manual intervention. When the alarm triggering state is removed, CS will automatically return to normal use.
Problem determination based on the following points
- Whether the green light on the power switch is on;
- Whether the buzzer in CM on;
- Whether the battery system can be communicated with inverter;
- Whether the battery can be output voltage or not.
-
Preliminary determination steps
- The LED display of CM and CS is normal, but it cannot charge and discharge. Observe the display screen of inverter and there is no SOC. Please check whether the CAN communication between CM to inverter is well connected. If the connection is good, please replace a CAN communication cable. If the SOC is still not visible on the inverter display screen, please contact the local distributor.
- After the battery system is powered on, if you can see the alarm information on the LED and inverter display screen at the same time, please contact the local distributor.
The copyright of this manual belongs to FOXESS CO., LTD. Any corporation or individual should not plagiarize, partially or fully copy (including software, etc.), and no reproduction or distribution of it in any form or by any means is permitted. All rights reserved. FOXESS CO., LTD.
- Add: No.939, Jinhai Third Road, New Airport Industry Area, Longwan District, Wenzhou, Zhej iang, China
- Tel: 0510- 68092998
WWW.FOX-ESS.COM
V1.0.5
10-500-10068-02
Documents / Resources
![]() |
Geizhals ECS2800 Static Content [pdf] User Manual ECS2800, CS2800, CM2800, ECS2800 Static Content, ECS2800, Static Content, Content |