Ledvion LVT10001_2m5s

Siostam Solais Rèile LED Ledvion

Model: LVT10001_2m5s

Ro-ràdh

Thank you for choosing the Ledvion LED Track Lighting System. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new lighting system. Please read these instructions carefully before installation and retain them for future reference.

Fiosrachadh Sàbhailteachd Cudromach

Susbaint pacaid

Dèan cinnteach gu bheil na pàirtean uile an làthair agus gun mhilleadh mus lean thu air adhart leis an stàladh.

Contents of the Ledvion LED Track Lighting System package, showing the 2-meter track rail, five black GU10 spotlights, mounting screws, wall plugs, power connector, and end cap.

Image: Components included in the Ledvion LED Track Lighting System package (SKU: LVT10001_2m5s).

Suidheachadh: Stiùireadh Stàlaidh

1. Mounting the Track Rail

  1. Choose a suitable location for the track rail, ensuring it is a flat and stable surface.
  2. Mark the drilling points on the ceiling or wall using the track rail as a template.
  3. Drill holes at the marked points and insert the wall plugs (if necessary).
  4. Secure the track rail to the surface using the provided screws.
  5. Connect the power supply wires to the power connector on the track rail, ensuring correct polarity (Live, Neutral, Earth). Consult a qualified electrician if unsure.
  6. Attach the end cap to the opposite end of the track rail.

2. Attaching the Spotlights

The spotlights feature a plug-and-play installation system for easy attachment and repositioning.

  1. Ensure the power is OFF at the main circuit breaker.
  2. Align the spotlight connector with the track rail slot.
  3. Push the spotlight firmly into the track until it clicks into place.
  4. Rotate the locking mechanism on the spotlight connector to secure it.
  5. Repeat for all five spotlights.
  6. Insert GU10 bulbs (not included) into each spotlight by twisting them into the socket.
Diagram showing the plug-and-play installation process for the track spotlights, illustrating how to insert and lock the spotlight onto the track rail.

Image: Plug and Play Installation for Ledvion track spotlights.

Technical drawing showing the dimensions of the 2-meter track rail and the individual spotlights, including length, height, and diameter.

Image: Dimensions of the Ledvion 2M track rail and spotlights.

Stiùireadh Obrachaidh

1. A ’toirt cumhachd air / dheth

Once installed, restore power at the main circuit breaker. Operate the track lighting system using your standard wall switch connected to the circuit.

2. Adjusting Spotlights

Each spotlight can be individually adjusted to direct light precisely where needed. The spotlights can be tilted 350 degrees in all directions and rotated 90 degrees.

Diagram illustrating the adjustable and rotatable features of the track spotlights, showing a spotlight tilting 350 degrees and rotating 90 degrees.

Image: Adjustable and Rotatable features of Ledvion track spotlights.

3. Gnìomhachd Dimmable

If you are using dimmable GU10 LED bulbs and an external dimmer switch compatible with LED lighting, you can adjust the light intensity to create the desired ambiance.

Cùram is cumail suas

Image showing an optional anti-glare grid for the spotlight, demonstrating how it can be easily added or removed to prevent glare.

Image: Optional anti-glare grid for Ledvion spotlights.

Fuasgladh thrioblaidean

Thoir sùil air a’ chlàr gu h-ìosal airson cùisean cumanta agus na fuasglaidhean aca.

TrioblaidAdhbhar a dh’fhaodadh a bhith annFuasgladh
Cha bhith solas a ’tionndadh.No power, loose connection, faulty bulb.Check circuit breaker. Ensure all connections are secure. Replace bulb.
Solais priobadh.Bulb sgaoilte, dimmer neo-fhreagarrach, uèirleadh lochtach.Tighten bulb. Ensure dimmer is LED compatible. Consult electrician for wiring check.
Spotlight not secure on track.Locking mechanism not engaged.Ensure spotlight is fully inserted and locking mechanism is rotated to secure position.

Sònrachaidhean Bathar

FeartMion-fhiosrachadh
BrandLedvion
Modail ÀireamhLVT10001_2m5s
Fad Track2 meters (2000 mm)
Overall Product Dimensions (packaged)105 x 20 x 15 cm
Cuideam nì2.14 cileagram
StuthAluminium
DathDubh
Voltage230 Volt
Seòrsa bulbLED (GU10 fitting)
DimmableYes (with compatible GU10 bulbs and external dimmer)
StoidhleSET 1 de sholais rèilichean
Dùthaich TùsSìona

Ùrachaidhean is Goireasan Roghainneil

The Ledvion track lighting system is expandable with various optional accessories to customize your lighting setup. These include different connectors and pendant spots.

Image displaying various optional accessories for the track lighting system, such as power feeders with cover plates or I-connectors, X-connectors, T-connectors, and adjustable cord pendant spots.

Image: Optional upgrades and accessories for Ledvion track lighting.

Fiosrachadh Barantais

Ledvion products are manufactured to high-quality standards. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. Please refer to your purchase documentation or contact customer support for specific warranty terms and conditions applicable in your region.

Taic Luchd-cleachdaidh

If you have any questions, require technical assistance, or need to report an issue, please contact your retailer or visit the official Ledvion weblàrach-lìn airson goireasan taic.

Dèanadair: Ledvion

Weblàrach: www.ledvion.com

Sgrìobhainnean co-cheangailte - LVT10001_2m5s

Ro-làimhview Leabhar-làimhe Stàlaidh Spot Talmhainn Ledvion GU10
Stiùireadh stàlaidh agus fiosrachadh sàbhailteachd airson an t-Solais Talmhainn Ledvion GU10 (ART.NO.LVO10137 & LVO10139). A’ gabhail a-steach mion-fhiosrachadh mu shàbhailteachd dealain, cumail suas, agus faighinn cuidhteas.
Ro-làimhview Balla a-muigh Ledvion LV010040 LampStiùireadh Stàlaidh & Fiosrachadh Sàbhailteachd
Stiùireadh stàlaidh coileanta, stiùiridhean sàbhailteachd, agus sònrachaidhean teicnigeach airson lampa balla a-muigh Ledvion LV010040ampDèan cinnteach gu bheil an solas agad air a shuidheachadh gu sàbhailte agus gu ceart.
Ro-làimhview Ledvion LVO10056 Outdoor Garden Spike Light Installation Guide
Step-by-step installation instructions for the Ledvion LVO10056 outdoor garden spike light. Learn how to safely install your GU10 5W 220-240V LED light, including safety precautions and care information.
Ro-làimhview Ledvion ART.NO.LV010023 Balla a-muigh Lamp - Stiùireadh Stàlaidh agus Fiosrachadh Sàbhailteachd
Stiùireadh stàlaidh mionaideach, rabhaidhean sàbhailteachd, sònrachaidhean teicnigeach, agus fiosrachadh gèillidh airson balla a-muigh Ledvion ART.NO.LV010023ampIonnsaich mar a stàlaicheas agus a chleachdas tu solais a-muigh Ledvion gu sàbhailte.
Ro-làimhview Leabhar-làimhe agus Dàta Teicnigeach airson Dimmer LED Ledvion
Leabhar-làimhe coileanta airson suidse Dimmer LED Ledvion (LV10001_1), a’ gabhail a-steach stiùireadh stàlaidh, diagraman uèiridh, sònrachaidhean teicnigeach, agus rabhaidhean sàbhailteachd. Ionnsaich mar a stàlaicheas agus a chleachdas tu an dimmer gu ceart airson an coileanadh as fheàrr le solais LED a ghabhas dimmadh.amps.
Ro-làimhview Leabhar-làimhe Stàlaidh is Cleachdaiche Socaidean a-muigh Ledvion
Tha an sgrìobhainn seo a’ toirt seachad stiùireadh stàlaidh, cleachdaidh, sàbhailteachd agus faighinn cuidhteas airson Socaidean a-muigh Ledvion. Tha ceumannan mionaideach ann airson an toradh a chuir suas, a uèirleadh agus obrachadh, còmhla ri rabhaidhean cudromach agus stiùiridhean cumail suas.