GATEXPERT PY2500AC Sliding Gate Opener
Specifications
- Models: PY1200AC, PY1800AC, PY2500AC
- Power Supply: AC110V/AC220V
- Warranty Period: 1 year
- Compatible with: Automatic sliding gates
Installation
- Read the instructions carefully before installation.
- Ensure power cable is unplugged when mounting and positioning the product.
- Motor cover must be removed to mount the motor to the mounting plate or concrete footing.
- Settings adjustments should only be made by a licensed electrician.
- Product is powered by AC110V/AC220V only; not compatible with DC backup battery or solar power.
Default Setting Instruction
The gate opener defaults to open the gate to the right-hand side. Test the gate opener before installation by plugging it into a power source and pressing the remote buttons. Ensure the gate opener is unplugged before proceeding with installation.
Safety Instruction
All work on the gate opener should be done with the power off and the opener unplugged. Keep fingers away from the motor output gear while it is turning.
Changing Opening Direction
If your gate needs to open from the left, refer to figure 3 in the manual. Mount the opener on the left-hand side, swap over the relative wires, and follow Terminal Instructions for swapping.
Frequently Asked Questions
Q: What is the warranty period for the gate opener?
A: The warranty period is 1 year from the date of the invoice. Refer to the warranty card and invoice for repair services.
Q: Can I use a DC backup battery with this product?
A: No, this product is only compatible with AC110V/AC220V power supply. DC backup battery or solar power is not compatible.
Sliding Gate Opener User Manual
PY1200AC/PY1800AC/PY2500AC
Website: www.gatexpert.com E-mail: sales@gatexpert.com
Instructions for PY1200AC/PY1800AC/PY2500AC
WARNING
Instructions must be read before installation. Please follow these instructions carefully, incorrect installation could affect gate operation.
When mounting and positioning this product please ensure the power cable is unplugged.
The motor cover will need to be removed to mount the motor to the mounting plate or directly to the concrete footing.
Any changes to the settings on this product can only be made by a licensed electrician. This product is only powered by AC110V/AC220V power supply; DC backup battery or
solar power is not compatible.
Instructions for PY1200AC/PY1800AC/PY2500AC
WARRANTY
1. To repair against this warranty card and invoice during the warranty period. 2. Warranty period: 1 year after the date of invoice. 3. Without unauthorized dismantling, any product broken or damage due to quality problem, we’ll offer the repair service for free or replace for free. 4. The malfunction and damages caused by incorrect use or man fault is not covered by this warranty.
CONTACT US
E-mail: sales@gatexpert.com
Please fill in the order information in the form below. All personal information you provided will be only used for warranty service and kept
strictly confidential. Refer to this list when contacting GATEXPERT for technical service or assistance with
your automatic gate opener.
Before installation: Test the gate opener by plugging it into a power source and pressing the
remote. Press the opening button, the output gear rotates, then press the stop button, the output
gear stops rotating. Finally, press the closing button, the output gear rotates to the opposite
direction. This will give you an understanding of the way in which the opener will move the gate.
Press the first/top button on the remote.
Rotating output gear will drive the gate frame.
Then the gate will move in the set direction.
Figure 2
Note: Ensure that the gate opener is unplugged before proceeding with installation. Please keep fingers away from the motor output gear whilst it is turning.
If your gate needs to open from the other direction (to the left, refer to figure 3), your opener needs to be mounted on the left-hand side as shown, the relative wires need to be swapped over, please check under “Terminal Instructions” for swapping. (Factory default setting is for right-hand opening: opener mounted on the right-hand side).
Figure 3 Any works done to the gate opener must be completed whilst the power is off, and the opener is
unplugged.
1
Instructions for PY1200AC/PY1800AC/PY2500AC
Safety Instruction
Warning: Incorrect or improper use of this product can cause damage to persons, animals or properties. · Please ensure that the input voltage used matches with the supply voltage of gate opener. · All modifications to wiring or electrics, and any adjustment or maintenance to input voltage
must be done by a qualified electrician. · All potential hazards and exposed pinch points of the gate must be eliminated or guarded prior
to installation of this gate opener. · Never mount any device that operates the gate opener where the user can reach over (under,
around or through) the gate to operate the controls. These must be placed away from any moving range of the moving gate. · Ensure power plug is disconnected from the power socket during installation or maintenance. · Keep remote control and other control devices out of children’s reach, in order to avoid unintentional activation. · To ensure safety, before installing the motor, mount a Gate End Catch and a Gate Stop at each end of the rail to prevent the gate travelling off the track. · If required, install infrared photocell to detect obstructions and prevent injury to person or damage to property. · Instruct all users about the control systems provided and the manual opening operation in case of emergency. · Ensure that the power cable is connected to a RCD protected weatherproof power outlet installed by a qualified electrician. · Do not install this product in an explosive atmosphere or where there is any danger of flooding. · This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous. · Only use original parts for any maintenance or repair operation. Our company declines all responsibility with respect to the automation safety and correct operation when other supplier’s components are used. · Do not modify the automation components, unless explicitly authorized by our company. · The user must avoid any attempt to carry out any works or repairs on this product, and should always request the assistance of qualified personnel. · This product is suitable for use on one sliding gate only. · Anything which is not expressly provided for in these instructions is not allowed and will void warranty. · Dispose of all packing materials (plastic, cardboard, polystyrene etc.) according to current guidelines. Keep plastic bags and polystyrene out of children’s reach. · Save these instructions for future use.
2
Instructions for PY1200AC/PY1800AC/PY2500AC
Parts List
Parts List (standard configuration)
No.
Picture
1
Name Motor
Quantity 1
2 3 4 4-1-1
4-1-2
Manual Release Keys
2
Remote Controls
2
Spring Limit Switch Accessories Box/ Magnetic Limit Switch Accessories Box
1
Spring Limit Switch Stop
Spring Limit Switch Stop Mounting Screw M6X10
Magnetic Limit Switch Stop
1 set 4
1 set
Magnets
2
Magnetic Limit Switch Stop Mounting Screws M6X16
4
Nuts M10
4
Flat Washers 10
2
Spring Washers 10
2
3
Instructions for PY1200AC/PY1800AC/PY2500AC
No.
Picture
5
Name Anchor Bolt M10
Quantity 4
5-1 5-2 5-3
Parts List (optional)
No.
Picture
1
2
3
4
5
Nuts M10
8
Flat Washers 10
8
Spring Washers 10
8
Note: Extra flat washers and spring washers are spare parts.
Name Galvanized Gear Rack
Nylon Gear Rack Infrared Photocell
Quantity 1m/pc 1m/pc 1
Wireless Keypad
1
Alarm Lamp
1
6
Mounting Plate
1
7
Hexagon Head Bolt M10X50
4
Additional remote controls: Spare/Additional remotes for the automatic gate kit, these will need to be paired to the motor. Infrared photocell: Detects pedestrians, vehicles and objects that cross an infrared beam and prevents the gate from closing. Wireless keypad: Allows secure access through the gate used with a user set code. Wired control: Allow users to control the opening and closing of the door through an external push-button. Alarm lamp: Alerts people near the gate and users that the gate is in operation.
4
Instructions for PY1200AC/PY1800AC/PY2500AC
Technical Parameters
Model Power Supply Motor Power Gate Moving Speed Maximum Loading Weight Remote Control Distance Remote Control Mode Limit Switch Working Noise Working Duty Recording of up Remote Controls Remote Frequency Working Temperature Package Weight
PY1200AC
PY1800AC
PY2500AC
110VAC/60Hz; 220VAC/50Hz
450W
600W
800W
11-13m/min
1200KG
1800KG
2500KG
30m
Single button mode / Three button mode
Spring limit switch / Magnetic limit switch
60dB
S2, 20min
Standard control board: 25; Intelligent control board: 40
433.92 MHz
-20°C – +70°C
16KG
17KG
17.5KG
Installation
Before You Start · PY1200AC/PY1800AC/PY2500AC Sliding Gate Automation Kit is suitable for powering the opening and closing motion of gates up to 1200, 1800, 2500kg in weight, up to a length of 12m. · Gate motion is achieved by the rotating output gear of the gate opener driving the gear rack
(sold separately) fitted to the moving gate. · The gate opener requires you to press the remote control once to open, and once again to
close. This is a safety feature to ensure safe operation. · The opener must be fitted within private property, never externally to a property’s boundary.
Any works done to the gate opener must be completed whilst the power is off and the opener is unplugged. Any modifications/alterations/works to AC power components must only be completed by
a licensed electrician.
Tools Required
· Tape measure · Level · 12mm concrete drill and hammer (when uses expansion screws) · Phillips head screwdriver · Straight screwdriver
5
Instructions for PY1200AC/PY1800AC/PY2500AC
Example Sliding Gate
Gate Track and Track Wheels Gate End Catch
Gate Guide Rollers
Gate Stop
Figure 4 Please ensure that the gate opener power cable is not plugged in at any stage before Step 8.
Step 1 – Gate Preparation
· Ensure that the sliding gate is correctly installed. · The gate is horizontal and level and the gate can glide back and forth smoothly when moved by
hand before installing the gate opener. · Wheels and guide rollers should rotate easily and be free from dirt or grime. · Track should be flat, level and firmly affixed. · Any misalignment in the gate will affect performance of the automatic gate opener.
The gate should slide smoothly by hand before attempting to install the gate opener. Figure 5
Step 2 – Checking Manual Release
· Insert the key and open the manual release bar to enable the motor get into manual mode and check that the motor output gear rotates freely by hand (Figure 6).
6
Instructions for PY1200AC/PY1800AC/PY2500AC
Turn 90°
To make the motor into manual mode, insert the key and open the manual release bar till it rotates by 90°.
Figure 6
In manual mode, the gear can turn freely and the gate can be operated by hand.
Step 3 – Removing / Installing Motor Cover
· Unscrew the two cover screws located at each side of the motor cover. · Remove the rubber grommet below the limit switch (Figure 7).
Figure 7 Please Note: the rubber grommet must be fitted back onto the motor cover once the
cover has been re-fitted/replaced onto the base of the motor.
7
Instructions for PY1200AC/PY1800AC/PY2500AC
Step 4 – Motor Pad Footing
· The motor pad concrete footing requires an area of no less than 450mm long x 300mm wide and a minimum depth of 200mm (Standard requirement).
· Ensure surface is level and parallel to the driveway.
Mounting Plate Dimensions Figure 8
Step 5 – Fitting Mounting Plate and Motor
Without Mounting Plate · Pre embed the anchor bolts according to holes in motor base before concerting (as per Figure
9). · Afater concrete hardening, bolt the motor with M10x50mm bolts, spring and flat washers
provided and tighten as required. (The height can be slightly adjusted by bottom bolts as per Figure 10).
Figure 9
8
Instructions for PY1200AC/PY1800AC/PY2500AC
Nut Spring Washer Flat Washer
Flat Washer Nut
The bolts and flat washer between mounting plate and motor base are used for adjusting the height of the motor. Figure 10
With Mounting Plate · Pre embed the anchor bolts as per 10 holes in Figure 8 before concreting, after hardening,
place the mounting plate, fit and tighten anchor bolts.(as per figure 11). · Bolt motor to the mounting plate using the M10 x 50mm bolts with spring and flat washers
provided and tighten as required (as per figure 12).
Figure 11
Nut Spring Washer Flat Washer
Flat Washer Nut
The bolts and flat washer between mounting plate and motor base are used for adjusting the height of the motor. Figure 12
9
Instructions for PY1200AC/PY1800AC/PY2500AC Fitting Motor · Fit motor and mounting plate(if with) on the concrete footing. · Ensure the motor output gear and gear rack are correctly aligned. Gear and gear rack should
be centered as much as possible. · Take the motor away from mounting plate.
Sliding Gate Frame (in open position)
Use pencil, chalk or similar tools to mark at the corners of mounting plate
Figure 13
Step 6 – Gear Rack & Motor Alignment
· See Figure 15 for recommended gear rack mounting height. · Ensure that the output gear has a minimum clearance of 1-2mm along the entire length of gear
rack fitted to the gate (as per Figure 14) · Ensure output gear and gear rack are correctly aligned. Under no circumstances should the
gate opener output gear carry any weight of the gate. It is the task of the gate castors or wheels to carry the weight of the gate (as per Figure 14). · If the gate doesn’t slide freely by hand, adjust the height of the gear rack accordingly until the full length of gate slides freely by hand.
10
Instructions for PY1200AC/PY1800AC/PY2500AC
Output Gear
Figure 14
Figure 15
Step 7 – Limit Switch Stops
Included in your gate opener kit are two limit switch stops which must be fitted to the gear racks on your gate to ensure safe operation.
11
Limit switch stop
Instructions for PY1200AC/PY1800AC/PY2500AC
Limit switch stop mounting screws
The limit switch stops are designed to set the desired opening and closing position of yoGuearr ragckate. These limit switch stops are designed to come into contact with the spring/magnetic limit switch. It is extremely dangerous that without or incorrect installation of the limit switch stops can cause crash of gate, damage of internal structure of the motor, moreover, the gate may slide off the guide rail.
Setting the Limit Switch Stops Closed Position · Position gate 150-200mm back from the gate end catch closed position. This will help in
making sure you do not slam the gate into the end stop/catch when setting the closed position under power. · Fit limit switch stop onto the top of gear rack at the point where it meets the Spring/Magnetic limit switch on the motor. · Tighten locking screws of limit switch stop.
Magnetic limit switch
Spring limit switch
12
Instructions for PY1200AC/PY1800AC/PY2500AC Open Position · Position gate 150-200mm back from the gate stop open position. This will help in making sure
you do not slam the gate into the end stop/catch when setting the open position under power. · Fit limit switch stop onto the top of gear rack at the point where it meets the Spring/Magnetic
limit switch on the motor. · Tighten locking screws of limit switch stop.
Spring limit switch
Magnetic limit switch
Test the spring/magnetic limit switch stops by moving the gate manually until you hear a click, making sure contact is made with the spring/magnetic limit switch on the motor. To Reset: Turning the power off will reset the limit switch stop memory. Power on the gate opener again, pressing remote control or external push button switch to open and then close the gate once, then new limit switch stop setting is completed.
13
Instructions for PY1200AC/PY1800AC/PY2500AC
Open Position Limit Switch Stop
Closed Position Limit Switch Stop
The installation of spring limit switch stops is shown in figure above.
Open Position Limit Switch Stop
Closed Position Limit Switch Stop
The installation of magnetic limit switch stops is shown in figure above.
Motor cover
Spring limit switch Limit switch stop
Mounting plate
14
Instructions for PY1200AC/PY1800AC/PY2500AC
Motor cover
Magnetic limit switch
Mounting plate
Open Position
Step 8 – Powering on
· Ensure that the outer cover has been fitted and fastened back onto the motor base. · Before powering up the gate opener make sure the gate can travel by hand in manual mode
(key unlocked). · Slide the gate to between the middle of the posts, approximately (see below diagrams). · Lock the manual release spanner (key locked) in readiness for automatic mode. · Plug the power cord into an approved RCD protected weatherproof outlet. · Remote controls included in this kit are factory paired ready for use.
Figure 16
Step 9 – Testing Travel and Limit Stops
Testing the Closed Position
15
Instructions for PY1200AC/PY1800AC/PY2500AC · Ensure gate opener is installed as per step 5, 6 and 7 and the sliding gate is in the middle
position. · Press remote (remotes included in kit are factory paired to the motor). The sliding gate will
begin to close. · The limit switch stop will hit the limit switch and the sliding gate will stop. · When the gate stops, measure the distance remaining between the sliding gate and the desired
closed position. · You have now determined the closed position of the sliding gate when the limit switch stop hits
the limit switch. · Adjust the limit switch stop from the measurement you have taken to get your final gate closed
position. The ideal closed final position for the gate frame is 10-15mm from closed gate end catch.
Testing the Open Position · Press remote, the sliding gate will begin to open. · The limit switch stop will hit the limit switch and the sliding gate will stop. · When the gate stops, measure the distance remaining between the sliding gate and the desired
open position. · You have now determined the open position of the sliding gate when the limit switch stop hits
the limit switch · Adjust the limit switch stops from the measurement you have taken to get your final gate open
position. The ideal open final position for the gate frame is 10-15mm from the gate stop.
To Reset: · When setting new limit stop positions please ensure that you turn the power off and
then on again. Turning the power off will reset the limit stop memory, allowing for new limit switch stop positions to be recognized by the motor.
Now the basic open and closed positions are set, for further setting functions and adjusting parameters, please refer to pages 17-30 in this manual.
16
Instructions for PY1200AC/PY1800AC/PY2500AC
Intelligent Control Board
Programming and Wiring
Any works to the 110V/220V AC must only be performed by a licensed electrician. Ensure power is off before any modifications are made.
Potentiometers
Dip Switches
Learn Button
Hall Sensor
J6 Terminal
J5 Terminal
Fuse (10A 250V fuse)
J4 Terminal
J1 Terminal
J2 Terminal Figure 17
J3 Terminal
17
Instructions for PY1200AC/PY1800AC/PY2500AC
DIP Switch Adjustment
All changes to these settings must be completed by a licensed electrician.
Figure 18
Number Function
Description
OFF-enable; ON-disable.
1
Slow Start Function Default OFF
OFF-normally open limit; ON-normally closed limit.
2
Limit Mode Switching Default ON, used with motor limit status, not
recommended to be modified by the user
Automatic close time setting: the gate is operated to
3
open by remote control operation and will close
automatically after a few seconds delay.
3 OFF 4 ON: automatic close delay time is 12s.
Automatic Close Time 3 ON 4 OFF: automatic close delay time is 24s.
4
3 ON 4 ON: automatic close delay time is 36s. 3 OFF 4 OFF: no automatic close function.
Default setting: 3 OFF 4 OFF
Disable the automatic close function.
OFF-enable
5
Auto-reverse Function
ON-disable Default position is OFF, this should align with the opener status and is not recommended to be
modified by the users.
OFF – Single channel
6
Remote Channel
ON – Three channels
18
Instructions for PY1200AC/PY1800AC/PY2500AC
Potentiometer Adjustment
All changes to these settings must be completed by a licensed electrician.
Figure 19
VR1: Stall Force Mode Maximum = More Force = Less sensitive Minimum = Less Force = More sensitive When Stall Force Mode is enabled (Dip switch 5 is at OFF position), the gate opener will detect obstacles and impacts to the gate. If this is during opening, the gate will stop, if this is during closing the gate will stop, and then re-open. Rotate VR1 clockwise to increase the stall force, anti-clockwise to decrease. For safety, we strongly recommend that Stall Force Mode is left enabled (Dip switch 5 is at the OFF position). Do not turn Dip switch 5 to the ON position. VR2: Brake Force Adjustment For adjusting brake force at the limit position during gate opening and closing. This should only be adjusted for heavy gates that need additional force to brake when limit switch is detected. Rotate VR2 clockwise to increase, counter-clockwise to decrease. Default setting is at minimum. VR3: Slow Stop Width Adjustment This switch controls how many seconds the gate opener operates at maximum speed. Rotate VR3 clockwise to increase, rotate counter-clockwise to reduce. When VR3 switches to minimum, slow start/stop function is disable. VR4: Motor Output Force Adjustment For best performance, set the torque at the lowest setting for secure use. Rotate clockwise to increase, counter-clockwise to decrease. Default setting is at maximum.
19
Instructions for PY1200AC/PY1800AC/PY2500AC
Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
L N PE
LAM P MOT M O T1M O T2
PE L N COM
J1
J1 Terminal
PE: Earth (yellow/green wire).
L: Power (brown wire). N: Power (blue wire).
J2 Terminal
J2
MOT1: Motor Terminal, swap with MOT2 to change gate
moving direction.
MOT2: Motor Terminal, swap with MOT1 to change gate
moving direction. MOTCOM: Motor Common Terminal.
LAMP (L&N): Connection for warning lamp.
PE: Motor and warning lamp earth
Note: If require to change the moving direction, not
only MOT1 and MOT2 wires need to be swapped, but
also the wires of 11 and 13 on J5 Terminal have to be
J3
swapped with each other.
J3 Terminal
Motor Capacitor
CAP
20
1 2 3 4 5 6 7 8 9 10 11 12 13 14
J6
J5
Instructions for PY1200AC/PY1800AC/PY2500AC
J6 Terminal: Port 13 and Port 14 output door closing in place feedback signals.
J5Terminal: Limit Switch and Accessories Additional accessories sold separately
Port 12Open Limit Switch Port 11Limit Switch Common Port Port 10Close Limit Switch Port 9Ground/Earth (GND) Port 8Photocell input (N.C.). If no photocell is fitted, use a jumper between Ports 8 & 9. Port 7Power supply for accessories (+15V)
J4 Terminal: (as per Figure 18)
Port 6: External Push Button Pedestrian Switch. Port 5: External button Single cycle button. (Cycle open/stop/close) Port 4Common Port for All External Control Push Button Port 3External Stop Push Button Switch. Port 2External Open Push Button Switch. Port 1External Close Push Button Switch.
Note: If require to change the moving direction, the wires of 11 and 13 on J5 Terminal have to be swapped with each other.
Wiring to the Terminal
J4
Using a screwdriver to loosen the screw on the side of the terminal.
Insert the wire into the number on the terminal that you are looking to connect to. Refer to Page 19.
Tighten with a screwdriver to secure the wire in place.
21
Instructions for PY1200AC/PY1800AC/PY2500AC
Connecting Infrared Photocells
The below steps must be completed by licensed electrician. Highly recommend the use of infrared photocells as an additional safety feature.
While closing, if the ray of the Infrared Photocell is blocked, the gate will stop and reverse immediately, to protect user and property security. To install photocells, connect wiring as per Figure 20. You must remove the wire jumper between terminal 8 and terminal 9 on J5 (ref to Figure 21). The distance between photocell receiver and photocell transmitter should not be less than 2 meters; otherwise, the induction effect of photocell may be affected.
Photocell Receiver
Photocell Transmitters
Before Installing Photocells
789
3 3core cable
Figure 20
2 core cable
89
89
Loosen 8 and 9 ports on J5 Terminal with a screwdriver. Make sure the power is disconnected before doing so.
Figure 21
Remove the wire jumper between ports 8 & 9 on J5 Terminal.
22
Instructions for PY1200AC/PY1800AC/PY2500AC
Remote Control Operation
Three button mode remote control: OPEN/CLOSE/STOP of motor are controlled by three buttons separately on the remote control. Single button mode remote control: OPEN/CLOSE/STOP of motor are controlled by one button circularly on the remote control. The forth button on remote control is Pedestrian Mode–press the forth button while the gate is closed, the gate will open 1m wide to allow pedestrian access.
Figure 22
Remote Control Learning Remove motor outer cover and continue to remove the transparent PCB cover, press the button `S1′ on the control board, until the `LEARN’ indicator light turns on, then release the button. While the light is on, press the button intended to be paired on the remote control twice, the `LEARN’ indicator light will flash repeatedly and then turn off when remote control is paired. A maximum 40 remote controls can be paired to one motor.
Press and hold learning button(S1) until the Learn LED flashed on.
While the light is on, press the first button on the remote control twice
The Learn LED will flash repeatedly and then turn off, when the remotes is paired.
Clearing Remote Controls To delete all paired remote controls, press and hold the button `S1′ till LEARN LED turns on. When the LEARN LED turns off, all previously paired remote controls will be deleted.
23
Instructions for PY1200AC/PY1800AC/PY2500AC
WIFI Controller (Optional)
I. Main parameters of the module: 1). Power Supply: AC110V/220V 2). Output single channel signal 3). Can accept closed in place signal
II. Wiring Instruction
Figure 23
As shown above: Output Terminal: Output signal, should connect to “O/S/C” and “COM” terminals on the motor control board. Position Feedback Terminal: Open or Closed in place feedback signal. Should connect to open/closed in place terminal if the motor control board has a standalone terminal for it. If the control board doesn’t have a standalone terminal, then should connect to the door magnetic alarm. Power: Should connect to AC 110V/220V mains power. III. Connect to Equipment Make sure your mobile phone has connected to the internet through 2.4G WIFI. This WIFI device only supports 2.4G WIFI. If you router supports both 5G and 2.4G WIFI, please select 2.4G WIFI. Download the Tuya or Smart Life App from App Store or Google Play Store. During paring, make sure your mobile phone and WIFI device is connected to the same WIFI router.
24
Instructions for PY1200AC/PY1800AC/PY2500AC Make sure the Mac address of your router is open, if not, please close the Mac flittering.
IV. APP Operation
Figure 24
Step 1: Open the App, click “add device”.
Step 2: If your mobile has connected to WIFI(must be 2.4GHz), long press the “reset” button on the WIFI device, your mobile will search the device automatically(Mark ); If the device can not be found automatically, please add it under “Add Manually”(Mark ): select Socket WIFI and follow its instructions to go proceed.
25
Instructions for PY1200AC/PY1800AC/PY2500AC Step 3: After added, the device will be shown in the list, you can re-name it to your required.
26
Instructions for PY1200AC/PY1800AC/PY2500AC Step 4: Before using your mobile to control the motor, please operate your gate for a single(no matter open or close) travel and record the travel time, then go to the settings to set the run time, this run time should be decided according to your gate running travel. For example, the travel time of opening is 23 sec., you can set the run time to be 25s.(recommended to set it a little bit longer than travel time, default setting is 20 sec.) If you set the run time on the APP shorter than travel time, then after the time is up on the APP, but the travel still hasn’t finished, there will be a reminder between this gap time:
Step 5: Now you can operate on your mobile, it will show “opening” while gate is opening, after reaching open limit switch, it will show opened. The same for closing.
Note: If your motor control board doesn’t have open/closed in place feedback signal, the app will send a reminder:
27
Instructions for PY1200AC/PY1800AC/PY2500AC
You can still control the opening and closing, but there is no feedback on the app after opened or closed.
It is suggested to use this WIFI control under your visible sight of the gate to avoid damage to persons or properties. For specific operation teaching, please refer to the video 1(overall operation), video 2(record the travel time) and video 3(operation after adjustment)
28
Instructions for PY1200AC/PY1800AC/PY2500AC
Maintenance
The gate should be checked every month to make sure it operates normally. For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular inspection is required. Before installation and operation of the gate opener, please read all instructions carefully. Our company keep the right to change the instruction without prior notice.
Troubleshooting
Any troubleshooting work below done to the motor must be completed by a licensed electrician and only whilst the power is off and the motor is unplugged!
Problem The gate cannot open or close normally, and LED does not light.
The gate can only open, but cannot close.
Possible Reason 1. The power supply is disconnected. 2. Fuse is blown. 3. Control board X1 terminal wrongly wired. 1. Photocell wrongly wired. 2. Photocell wrongly installed. 3. Photocell is blocked by objects. 4. Sensitivity of obstacle is too high (Intelligent type). 5. Hall sensor parts damaged (Intelligent type).
Remote control doesn’t work.
Press OPEN, CLOSE button, the gate is not moving, motor has noise.
1. Battery level is too low. 2. Remote control not paired. 1. Capacitor damaged. 2. Capacitor is poor connected. 3. Gate moving is not smoothly
Not stop when running to opening or closing limit switch position.
1. The opening or closing limit switch is in opposite. 2. Magnetic limit switch badly installed.
Leakage switch tripped.
Power supply cable short circuit or motor wire short circuit.
Solution 1. Connect the power supply. 2. Check the fuse (FU) and replace if blown. 3. Re-wiring according to user manual. 1. If not connect photocell, please ensure the infrared port and GND port has a jumper wire; if connect photocell, please ensure the wiring is correct and the photocell status is N.C. 2. Ensure that the photocell mounting position can be mutually aligned. 3. Remove the obstacle. 4. Reduce the sensitivity of obstacle. 5. Replace hall sensor parts. 1. Change the battery. 2. Pair the remote control to the gate opener.
1. Change capacitor. 2. Check the capacitor wiring. 3. Adjust the motor or gate according to the actual situation.
1. Check whether the limit switch wiring is consistent with the motor running direction. 2. Check whether the distance and height between magnetic limit switch and motor reaches to standard requirement.
Check wiring.
29
Instructions for PY1200AC/PY1800AC/PY2500AC
Drawing and Measurements
Figure 25
30
Documents / Resources
![]() |