GASDOC GS2001 Propane Gas Detector
Please strictly follow the instructions before operating the product Support@gasdoctools.com
Installation and Operation
Installation
Propane is a combustible gas heavier than air that accumulates in the lower parts of the home. The GasDoc GS2001 Propone Monitor should be installed where gas accumulates, such as next to a stove, water henter, furnace or oven. Mount your detector around 4° 12 inches (10-30 centimeters) away from the floor to ensure the earliest opportunity to detect a leak. If there are several potential gas leak areas, we recommend installing one for each area. Refer to Figures 1 and 2.
Regarding the installation location, the following locations are not recommended:
- Locations that have an odor.
- Vaporous places.
- On outside walls.
- Within 12 inches (30 centimeters) of doors, windows, vents, vacuuming fon (exhaust fan, etc.).
- Locations with dirt and dust that may block the detector.
- Locations behind furniture, drapes or large items that will block air movement.
- In a location with wiring controlled by a wall switch or a ground fault protector.
- Other drafty areas that aren’t mentioned above.
The device must be powered from the RV’s 12V DC power system and connected to a properly fused circuit.
For the FLUSH MOUNT type, please install with the following steps:
- Disconnect 12V DV power supply until installation is completed;
- Cut a hole with dimensions of 3 3/8″width x 2″‘height (90×50 mm);
- Connect the power with the GS2001 alarm (Referred to “Connect the Power”);
- Fasten the alarm to the wall using the two screw holes at the two ends of the bracket;
- Recheck the Power Connection (12V [+) to red & Ground [-] to black);
- Reconnect the power supply.
For the SURFACE MOUNT type, please install with the following steps:
- Disconnect 12V DV power supply until installation is completed;
- Choose a suitable bracket from the included two surface mount brackets (Long & Short),
- Drill o 5/8″ hole for the wire and wire connector;
- Connect the power with the 652001 alarm (Referred to “Connect the Power”);
- Fasten the alarm to the wall using the two screw holes at the two ends of the bracket;
- Recheck the Power Connection (12V [+] to red & Ground [-] to black);
- Reconnect the power supply.
Connect the Power
To power the device, it should be connected to the RV’s 12V DC power system through a properly fused circuit. Please follow these steps while ensuring the power supply remains off:
- Strip the wire of insulation in 1/2 inch (12mm).
- Straighten the orange operation handle and insert the wire into the hole
- Connect the 12V DC Power Wire to the red [+] wire and Ground to the black I-] wire.
- Push the lever horizontally to securely fasten the wire for brake purposes.
- Refer to the Wire Diagram provided for additional guidance on proper connections.
Documents / Resources
![]() |
GASDOC GS2001 Propane Gas Detector [pdf] Instruction Manual GS2001 Propane Gas Detector, GS2001, Propane Gas Detector, Gas Detector, Detector |