FX Luminaire XN-70 In Grade Light
Specifications
- Product Name: IN-GRADE LIGHT | XN-70
- Input Voltage: 11-15 V
- Energy Efficiency Class: G
Product Usage Instructions
Before installing or using the IN-GRADE LIGHT XN-70, please read and understand all safety and use instructions provided in the manual.
Installation
- Ensure the input voltage is within the range of 11-15 V.
- Refer to the XN-70 Core Drill Guide at fxl.help/XN70drill for proper installation guidelines.
- Position the light fixture in the desired location, typically 12 to 18 inches from the surface.
- Connect the low-voltage cable following the specifications mentioned in the manual.
Operation
Once installed, turn on the power source to activate the IN-GRADE LIGHT XN-70. The energy-efficient light source will provide illumination for landscape and architectural lighting purposes.
Maintenance
Regularly inspect the fixture for any damage or wear. Clean the light surface gently with a damp cloth if needed. Ensure the connections are secure and free of corrosion.
INSTALLATION INSTRUCTION
INTRODUCTION
- Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at fxl.com/support.
SAFETY INSTRUCTION
WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:
- Turn off /unplug and allow to cool before replacing the lamp.
- The lamp gets HOT quickly. Contact only the switch/plug when turning on.
- Do not touch the hot lens, guard, or enclosure.
- Keep the lamp away from materials that may burn.
- Do not touch the lamp at any time. Use a soft cloth.
- Oil from skin may damage the lamp.
- Do not operate the fixture fitting with a missing or damaged shield.
WARNING – Risk of Electric Shock
- May be installed less than 5′ (1.5 m) from a pool, spa, or fountain, when used with a UL 379 listed transformer.
- A fixture shall not use tungsten halogen lamps unless the fixture is marked for such lamps.
- Supply connections and electrical components are located above ground level, except for the secondary cord, which is suitable for wet locations.
LOW-VOLTAGE CABLE SHALL
- Be protected by routing in proximity to the fixture or fitting, or next to a building structure such as a house or deck.
- Not to be buried except for a maximum of 6″ (152 mm) to connect to the main low-voltage cable.
- Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a fixture, or a fitting.
FCC
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by taking one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not expressly approved by Hunter Industries could void the user’s authority to operate this device.
If necessary, consult a representative of Hunter Industries Inc. or an experienced radio/television technician for additional suggestions.
CUSTOMER SERVICE
- LANDSCAPE & ARCHITECTURAL LIGHTING | Learn more. Visit fxl.com
- fxl.com/support.
- These products contain a light source of energy efficiency class G.
- Voltage Drop Calculator fxl.com/voltage-drop-calculator.
- XN-70 Core Drill Guide fxl.help/XN70drill.
FAQ
What should I do if the light is not turning on?
Check the power source and connections to ensure they are properly set up. If the issue persists, contact your local distributor or visit fxl.com/support for further assistance.
Can I use a different voltage input for this light?
No, it is recommended to operate the IN-GRADE LIGHT XN-70 within the specified voltage range of 11-15 V to ensure optimal performance and safety.
Documents / Resources
![]() |