FSP Smart Power Distribution Unit User Manual

Smart Power Distribution Unit

Specifications

  • Model: Power Distribution Unit
  • Version: 1.0
  • Designed to distribute AC power from a single source to 8
    outputs
  • Advanced load monitoring
  • Local or remote ON/OFF switching control of individual
    outlets

Product Usage Instructions

1. Installation

2-1 Rack Mounting

Follow the steps below to install the PDU module in a 19-inch
bay:

  1. Ensure the rack has a depth of 600mm.
  2. Place the PDU at the desired height in the cabinet
    uprights.
  3. Secure the device to the cabinet using four screws.

2-2 Connections

To connect the PDU:

  1. Plug the input to the mains or UPS based on requirements.
  2. Plug the equipment into the output sockets.

2. Operation & Display

3-1 Panel Overview

The panel includes:

  1. On/Off button
  2. Select button
  3. LCD display showing various information like input voltage,
    current, output details, and fault codes.
  4. Power indicator (Yellow)
  5. Fault indicator (Red)
  6. Mute/Function button

FAQ

Q: What should I do if the fault indicator is showing a red
light?

A: If the fault indicator is lit red, check the detailed fault
codes in section 3-2-4 of the manual to identify the issue.

Q: Can I use extension cords with this PDU?

A: No, it is advised not to use extension cords or adapters with
the PDU for safety reasons.

Q: How can I silence the buzzer on the PDU?

A: Press the MUTE/FUNCTION button to silence the buzzer on the
PDU.

“`

User Manual Power Distribution Unit
Version: 1.0

Table Of Contents
1. Introduction …………………………………………………………………………………………………….. 1 1-1 Package Contents………………………………………………………………………………………. 1 1-2 Safety……………………………………………………………………………………………………… 1 1-3 Disposing of PDU ………………………………………………………………………………………. 1 1-4 Function ………………………………………………………………………………………………….. 1 1-5 Overview …………………………………………………………………………………………………. 2
2. Installation ………………………………………………………………………………………………………. 3 2-1 Rack Mounting ………………………………………………………………………………………….. 3 2-2 Connections ……………………………………………………………………………………………… 3
3 Operation & Display ……………………………………………………………………………………………. 4 3-1 Panel Overview …………………………………………………………………………………………. 4 3-2 Operation ………………………………………………………………………………………………… 4
4. Technical Specification ……………………………………………………………………………………… 10

1. Introduction
1-1 Package Contents
PDU x 1 User Manual x 1 USB cable x 1 Input IEC-SCHUCKO 16A cable
1-2 Safety
The PDU must be connected to earth while in use. Do not use extension cords or adapters with this PDU. Ensure the power cord and sockets are in good condition. To reduce the risk of fire or electrical shock, PDU installation has to be in a
temperature and humidity controlled indoor environment. Ambient temperature must not exceed 50°C. The PDU is not intended for outdoor use.
1-3 Disposing of PDU
The PDU contains internal components that are considered toxic or hazardous waste such as electronic circuit boards. For proper disposal, contact your local recycling/reuse or hazardous waste center.
1-4 Function
The PDU is designed to distribute AC power from a single source to 8 outputs with advanced load monitoring and local or remote ON/OFF switching control of individual outlets.
1

1-5 Overview

FRONT VIEW

REAR VIEW

Input switch
USB communication port
RS232 communication port SELECT button: to toggle the different status screens in LCD display ON/OFF button: to turn on or off the outputs LCD display
Mains indicator

Fault indicator MUTE/FUNCTION button: to silence the buzzer Expansion slot for communication boards
Output IEC 10A sockets
Input 16A plug

2

2. Installation
2-1 Rack Mounting
Following figure shows how to install the PDU module in a 19-inch bay (with a depth of 600mm) at the desired height in the cabinet uprights. Secure the device adequately to cabinet with four screws.
2-2 Connections
For connecting the PDU, plug the input to the mains or to the UPS depending on user’s requirements. Plug the equipment to the outputs.
3

3 Operation & Display
3-1 Panel Overview
1. On/Off button 2. Select button 3. LCD display: for detailed LCD operation, please check section 3-2. 4. Power indicator (Yellow) 5. Fault indicator (Red) 6. Mute/Function button On the LCD display, it will show the following information:
Input voltage Input current Output current for each output socket Output watt for each output socket Output watt-hour for each output socket Numerical pug icon to represent each output socket
icon on = output on icon off = output off icon blinking = output overload (alarm overload or output shutdown due to overload) Fault code (please check section 3-2-4 for detailed codes)
3-2 Operation
The LCD display allows you to view the status of each output (ON / OFF), input voltage, input current, the current on each output and any alarm codes present. Eight digital numbers displayed on the bottom of LCD to represent the eight output sockets. If the numerical icon is on, the represented output socket is powered on. If the numerical icon is off, the represented output socket is powered off. If the numerical icon is blinking, the represented output socket is overload.
4

3-2-1 SELECT Button The SELECT button allows you to scroll through different status screen. The LCD displayed information will be switched in turns by pressing SELECT button. The displayed information is switched as below order: Total input voltage/input current, input voltage/output current for each active numerical plug and fault codes.

Information

LCD Display

Input Voltage

Input Current

Input Voltage

Output 1 Current

Input Voltage

Output 2 Current

Input Voltage

Output 3 Current

Input Voltage

Output 4 Current

Input Voltage

Output 5 Current

5

Input Voltage

Output 6 Current

Input Voltage

Output 7 Current

Input Voltage

Output 8 Current

Input Voltage

Alarm code F05: overload alarm on output 5. Current available outputs are plug 1, 5 and 8.
Fault codes will be displayed in turns automatically if more than two faults or lock alarms occur. (Refer 3-2-4. “Alarm code” for the details)

Back to the top

3-2-2 ON/OFF Button The ON/OFF button allows you to switch on or off output sockets one by one.

Turn on selected output socket To switch on a numerical output socket, you have to switch to specific plug number shown on left corner by keep pressing SELET button. Then, press ON/OFF button (1 to 2 sec) until the represented number is displayed on the bottom of LCD screen.

Turn off selected output socket To switch off a numerical output socket, you have to switch to specific plug number shown on left corner by keep pressing SELET button. Then, press ON/OFF button (1 to 2 sec) until the represented number is faded on the bottom of LCD screen.

The ON/OFF button is no function while it’s shown input current or the Alarm code in LCD display.

6

3-2-3 Mute/Function Button
Two functions by pressing Mute/Function button. Mute function by pressing and hold the button for at least 3 seconds. Function button by quick press the button

Mute Operation When the buzzer is sounding due to alarms, the buzzer can be mute by pressing this button. After buzzer is mute, if warning situation remains, it’s possible to press this button to have buzzer sound again. If one or more alarms occur after buzzer has been mute, the buzzer will sound again.

Function Operation

It’s to switch displayed information on specific output. The displayed information is output

current, output wattage and output wattage-hour in order. You may switch to specific

output by pressing “SELECT” button. When requested plug number is shown on left digital

area, quick press “FUNCTION” button to switch displayed information.

Information

LCD Display

Input Voltage Output 1 Current

Input Voltage Output 1 Wattage

Input Voltage Output 1 Wattage-Hour

Back to
Output 1
Current screen

7

3-2-4 Alarm Code/LED/Buzzer

CODE DESCRIPTION

A01 Low input voltage

A02 High input voltage

S01

Immediate shutdown on Output 1

S02

Immediate shutdown on Output 2

S03

Immediate shutdown on Output 3

S04

Immediate shutdown on Output 4

S05

Immediate shutdown on Output 5

S06

Immediate shutdown on Output 6

S07

Immediate shutdown on Output 7

S08

Immediate shutdown on Output 8

F01 Overload alarm on Output 1

F02 Overload alarm on Output 2

F03 Overload alarm on Output 3

F04 Overload alarm on Output 4

F05 Overload alarm on Output 5

F06 Overload alarm on Output 6

F07 Overload alarm on Output 7

F08 Overload alarm on Output 8

F09 Low input current

Fault LED ON

MAINS LED
Blinking

ON

Blinking

Blinking

OFF

Blinking

OFF

Blinking

OFF

Blinking

OFF

Blinking

OFF

Blinking

OFF

Blinking

OFF

Blinking

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

8

Buzzer
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF
0.5s ON / 0.5s OFF
0.5s ON / 0.5s OFF
0.5s ON / 0.5s OFF
0.5s ON / 0.5s OFF
0.5s ON / 0.5s OFF
0.5s ON / 0.5s OFF
0.5s ON / 0.5s OFF
0.5s ON / 0.5s OFF
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF
0.5s ON / 1.0s OFF

F10 High input current

ON

F11 Power Fail on Auxiliary 1

ON

F12 Power Fail on Auxiliary 2

ON

L01 Lock for overload on Output 1

ON

L02 Lock for overload on Output 2

ON

L03 Lock for overload on Output 3

ON

L04 Lock for overload on Output 4

ON

L05 Lock for overload on Output 5

ON

L06 Lock for overload on Output 6

ON

L07 Lock for overload on Output 7

ON

L08 Lock for overload on Output 8

ON

L13 High input voltage

ON

OFF

0.5s ON / 1.0s OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

NOTE: The output lock due to overload is permanent and only can be reset by switching on the locked output again. Please simply press the ON/OFF button to turn on the output.

9

4. Technical Specification

Input

Input Plug

IEC C20 16A 250V

Cord Entry

Rear feed

Maximum Input Current 16A

Rated Input Current 16A

Nominal Input Voltage 220V/230V/240V

Rated Input Voltage

184 ­ 300V

Input Frequency

50Hz/60Hz

Power Capacity

3.68KVA at 230V

Overload Protection

16A Breaker

Output

Nominal Output Voltage 220V/230V/240V

Rated Output Voltage 184 ­ 300V

Output Connections

(8) IEC C13

Output Current Accuracy

+/- 0.1A

Physical

Dimensions (D x W x H) (mm)

250 x 430 x 44

Color

Black

Weight (Kg)

3.5

Environmental

Operation Environment 0 ­ 50

Operation Relative Humidity Altitude Conformance
EMC
Safety

0 ­ 90% No condensing
<1000m
EN 55022 Class B EN 61000-3-2 EN 61000-3-3 EN 55024 EN60950-1

10

Documents / Resources

FSP Smart Power Distribution Unit [pdf] User Manual
Smart Power Distribution Unit, Power Distribution Unit, Distribution Unit

References

Leave a comment

Your email address will not be published. Required fields are marked *