Fronius logoTS 65A-3 Smart Meter TS 5KA-3 Bidirectional Power Meter
User Guide

BOSCH GCM 12 SDE Professional Heavy Duty Mitre Saw - iconWARNING! Incorrect operation and incorrectly performed work can cause serious personal injury or material damage. The Fronius Smart meters may only be installed and commissioned by trained personnel and only within the scope of the technical regulations. Before working with the device, read and understand all enclosed, printed, and online documents! This document does not describe all of the possible system configurations.

Fronius TS 65A 3 Smart Meter TS 5KA 3 Bidirectional Power Meter -1

Fronius TS 65A 3 Smart Meter TS 5KA 3 Bidirectional Power Meter -2

SOFTWARE REQUIREMENTS
Fronius Datamanager 2.0 ≥ 3.16.1 version
Fronius Symo Hybrid ≥ 1.16.1 version
MEASURING INPUT
Nominal voltage (4-conductor) range 208 – 400 V (±20%)
Power consumption in the voltage path (max. voltage) ≤ 10 VA
Nominal frequency
Tolerance
50 – 60 Hz
45 – 65 Hz
Nominal current, lb 5 A
Maximum current, Imax 65 A
Starting current 20 mA
Short-time overload (EN IEC 62053-21, EN IEC 62053-23) 30 lmax / 0.001 s
Self-consumption – current path (max. current) ≤ 1 W
Power factor
Operating range
(EN IEC 62053-21, EN IEC 62053-23)
active cosφ 0.5 ind – 0.8 cap,
reactive sinφ 0.5 ind – 0.5 cap
Current distortion factor in acc. with EN 50470
OUTPUT
RS485 communication (Electrically isolated from measuring input)
Standard RS485 – 3 conductors
Protocol Compatible with Modbus RTU
Addresses 1 – 255
Baud rate 300, 2400, 9600 bit/s
Response time ≤ 200 ms
INSULATION (EN IEC 62052-11, EN IEC 62053-21)
Installation category III
Degree of pollution 2
Insulation voltage 4 kVAC RMS (1 min)
ELECTROMAGNETIC COMPATIBILITY
Emission test In acc. with EN IEC 62052-11, EN 50470-3
Immunity test In acc. with EN IEC 62052-11, EN 50470-3
OPERATING CONDITIONS
Reference temperature 25 °C (± 5 °C)
Operating range -25 to +55 °C
Temperature limit for storage and transport -30 to +80 °C
Mechanical environment
Electromechanical environment
M2
E2
HOUSING
Housing 3 modules according to DIN 43880
Sealable housing/terminal cover
Connection Screw connection
Mounting Can be snapped onto 35 mm DIN rail
Housing material Noryl, self-extinguishing
Degree of protection (EN 60529) IP51 housing, IP20 connections
Weight 240 grams
TERMINALS – MEASURING INPUT
Wire min. 1 mm² / max. 16 mm²
Recommended torque max. 2.8 Nm
TERMINALS – DATA OUTPUT (N-CONNECTOR)
Wire min 0.05 mm²
Recommended torque max. 0.4 Nm

Detailed, country-specific warranty terms are available on: www.fronius.com/solar/warranty

FIND MORE INFORMATION
manuals.fronius.com/html/4204260349

Fronius TS 65A 3 Smart Meter TS 5KA 3 Bidirectional Power Meter - qr code

https://manuals.fronius.com/html/4204260349/en.html
Fronius TS 65A 3 Smart Meter TS 5KA 3 Bidirectional Power Meter - icon42,0410,2496 006-22042021

FRONIUS INTERNATIONAL GMBH

Documents / Resources

Fronius TS 65A-3 Smart Meter TS 5KA-3 Bidirectional Power Meter [pdf] User Guide
TS 65A-3, Smart Meter TS 5KA-3 Bidirectional Power Meter
Fronius TS 65A-3 Smart Meter [pdf] Instruction Manual
TS 65A-3 Smart Meter, TS 65A-3, Smart Meter

References

Leave a comment

Your email address will not be published. Required fields are marked *