1. Introduction
The KETOTEK AC 40-300V 100A Single-Phase Digital Energy Meter is a versatile device designed for accurate measurement and display of various electrical parameters. This meter is suitable for DIN rail installation and provides real-time data for voltage, current, active power, energy consumption, frequency, and power factor.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your energy meter. Please read it thoroughly before use.
2. Principales caractéristiques
- Multimètre 6 en 1 : Affiche simultanément le volume CAtage (40-300V), AC Current (0-100A), Active Power (0-30000W), Electric Energy (0-99999kWh), Frequency (45-65Hz), and Power Factor (0-1PF).
- Écran LCD haute définition : Features a colorful HD LCD screen with a 178° wide viewing angle and backlight function for clear visibility in various lighting conditions.
- Durable et fiable : Constructed from high-quality ABS flame-retardant material with a high-precision chip, ensuring safe operation, good electromagnetic anti-interference, low power consumption, and long service life.
- Data Retention and Reset: Automatically saves electrical energy data upon power loss and resumes accumulation when power is restored. A dedicated reset button allows for clearing accumulated data.
- Large application : Suitable for various environments including schools, markets, homes, industrial settings, and laboratories. Capable of measuring non-standard sine waves from inverters.
KETOTEK 6-in-1 Electricity Meter displaying AC Current, Power Factor, Frequency, AC Voltage, Active Power, and Electricity Consumption (KWh).
3. Spécifications
| Paramètre | Valeur |
|---|---|
| Fabricant | CÉTOTEK |
| Numéro de modèle | D52-2047HD |
| Dimensions (L x l x H) | 5.4 x 6.4 x 8 cm |
| Poids | 141 grammes |
| Voltaget gamme | 40-300 V CA |
| Gamme de courant | 0-100A |
| Plage de puissance active | 0-30000W |
| Gamme d'énergie électrique | 0-99999 kWh |
| Gamme de fréquences | 45-65 Hz |
| Plage de facteur de puissance | 0-1PF |
| Matériel | ABS |
| Type d'affichage | Écran LCD |
| Certification | CE |
Product parameters for the KETOTEK energy meter, showing ranges for Voltage, Current, Frequency, Power Factor, Electric Energy, and Power.
Technical drawing with precise dimensions of the KETOTEK single-phase energy meter, indicating its length, width, height, and DIN rail installation compatibility.
4. Consignes de sécurité
AVERTISSEMENT: Installation and maintenance should only be performed by qualified personnel to prevent electric shock or damage to the device. Always disconnect power before working on electrical circuits.
- Ensure the power supply is completely disconnected before installation or wiring.
- Vérifiez que le voltage and current ratings of the meter match your application requirements.
- N'utilisez pas l'appareil dans des conditions humides ou damp conditions.
- Avoid exposing the meter to direct sunlight or extreme temperatures.
- Utilisez un équipement de protection individuelle (EPI) approprié lors de l'installation.
5. Installation
5.1 Montage sur rail DIN
The KETOTEK energy meter is designed for standard 35mm DIN rail installation. Simply clip the meter onto the DIN rail in your electrical panel.
The KETOTEK energy meter installed on a 35mm DIN rail within an electrical panel.
5.2 Instructions de câblage
Refer to the wiring diagram below for correct connection. The meter requires both a live (L) and neutral (N) connection for its own power supply and for voltage measurement. For current measurement, one of the load cables (either live or neutral) must pass through the integrated current transformer hole.
- Connectez le vol d'entrée ACtage (Live and Neutral) to terminals 1 and 2 of the meter.
- Pass one of the load cables (Live or Neutral) through the current sensing hole on the right side of the meter. The direction in which the cable passes through the hole does not affect the measurement.
- Assurez-vous que toutes les connexions sont sécurisées et correctement isolées.
- For three-phase systems, connect only one live wire and the neutral wire to the meter for measurement.
Wiring diagram for the KETOTEK single-phase energy meter, showing connections with circuit breakers and loads.
Detailed diagram of the integrated current transformer, showing how to pass the load cable through the 10mm hole.
6. Fonctionnement
6.1 Mise sous tension
Once properly wired and power is supplied, the meter will automatically power on and display the measured electrical parameters on its LCD screen.
6.2 Modes d'affichage
The meter cycles through different display screens, showing various parameters such as voltage, current, active power, energy, frequency, and power factor. The colorful HD LCD ensures clear readability.
Examples of the KETOTEK energy meter displaying real-time electrical measurements in various applications.
6.3 Data Reset
To reset the accumulated electrical energy (kWh) data, press and hold the blue "RESET" button on the front panel for approximately five seconds. The energy value will reset to zero.
The meter automatically stores the accumulated energy data even if power is interrupted. When power is restored, it will continue to accumulate from the last saved value.
7. Dépannage
- Pas d'affichage : Vérifiez si le vol d'entrée ACtage is correctly connected to terminals 1 and 2 and within the specified range (AC 40-300V). Ensure power is supplied to the circuit.
- Current/Power Reading is Zero: Verify that one of the load cables is correctly passed through the integrated current transformer hole. Ensure there is an active load drawing current.
- Lectures inexactes : Confirm that the wiring is correct according to the diagram. Ensure the meter is not exposed to strong electromagnetic interference.
- Affichage scintillant : While some minor fluctuations in decimal values are normal for real-time measurements, ensure stable power supply. If flickering is excessive or constant, recheck connections.
8. Entretien
- Veillez à ce que le compteur reste propre et exempt de poussière. Utilisez un chiffon doux et sec pour le nettoyer. N'utilisez pas de produits abrasifs ni de solvants.
- Regularly inspect wiring connections to ensure they remain tight and secure.
- Évitez les chocs physiques et les chutes de l'appareil.
- No user-serviceable parts inside. Do not attempt to open or repair the meter yourself.
9. Garantie et assistance
Les produits KETOTEK sont fabriqués selon des normes de qualité élevées. Pour toute information concernant la garantie ou l'assistance technique, veuillez consulter les coordonnées fournies avec votre achat ou visiter le site officiel de KETOTEK. website.
Veuillez conserver votre preuve d'achat pour toute réclamation au titre de la garantie.