Specifications

  • Models: FWF-80F-2R, FWF-81F-2R, FWF-81F-2R-POE, FWF-80F-2R-3G4G-DSL, FWF-81F-2R-3G4G-DSL, FWF-81F-2R-3G4G-POE
  • Package Contents: FortiWiFi Device, DC Power Adapter, Antennas, Power Cable, Ethernet Cable, RJ-11 Cable (DSL models only)

Product Usage Instructions

Before You Begin

Register your device at https://support.fortinet.com for updates, management, and support.

The Essentials

Setup Options
Set up your Fortinet device locally or via forticloud.com using GUI or CLI:

  • GUI Setup:
    1. Connect Port 1 with an Ethernet cable to the management computer.
    2. For static IP configuration, use 192.168.1.1 with subnet mask 255.255.255.0.
  • CLI Setup:
    1. Connect the console port to the management computer using a USB console cable (available for purchase).
    2. Set speed to 9600, data bits to 8, stop bits to 1, parity to None, and flow control to None.

FortiGate Cloud Key Setup

  1. Go to forticloud.com and login or register.
  2. Follow on-screen instructions and click Add FortiGate.
  3. Enter the FortiGate Cloud Key found on your device’s sticker.

FAQ

  • Q: How do I access technical support?
    A: Visit Fortinet Technical Support for Resource Center and services.
  • Q: What are the default login credentials?
    A: For local access, use admin as the username with no password. WiFi SSID is fortinet with password fortinet.
  • Q: How do I know if the device is operating normally?
    A: Check the LED indicators on the front panel for different statuses related to power, WiFi, and connectivity.

This document is prepared in English and French. In case of conflict between them, the English version shall prevail over the French version.
This guide covers: FWF-80F-2R, FWF-81F-2R, FWF-81F-2R-POE, FWF-80F-2R-3G4G-DSL, FWF-81F-2R-3G4G-DSL, and FWF-81F-2R-3G4G-POE
August 16, 2024
Copyright© 2021 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties, whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinet’s General Counsel, with a purchaser that expressly warrants that the identified product will perform according to certain expressly-identified performance metrics and, in such event, only the specific performance metrics expressly identified in such binding written contract shall be binding on Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet’s internal lab tests. In no event does Fortinet make any commitment related to future deliverables, features or development, and circumstances may change such that any forward-looking statements herein are not accurate. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied. Fortinet reserves the right to change, modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable.
For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf

The Essentials

Default Logins
https://192.168.1.99
Username: admin
Password: leave blank
SSID: fortinet
Password: fortinet

Fortinet Documents Library
For a detailed Administration Guide, up-to-date Hardware documentation and Reference Manuals, visit https://docs.fortinet.com/

Customer Service
For contracts, licensing, product registration and account management, contact FortiCare Support at https://www.fortinet.com/support/contact

Technical Support
To access our Resource Center, Professional Services and Technical Support Services, visit https://www.fortinet.com/support

Thank you for choosing Fortinet

Package Contents

FortiWiFi 80F-2R Series
FWF-80F-2R*, FWF-81F-2R*, FWF-81F-2R-POE*, FWF-80F-2R-3G4G-DSL**, FWF-81F-2R-3G4G-DSL**, FWF-81F-2R-3G4G-POE**
FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (1)

Note: FortiWiFi models use the same antennas for WiFi and DSL/3G4G

Setup Options

Set up your Fortinet device locally or connect using forticloud.com

GUI
FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (2)

Note: For static IP configuration, use 192.168.1.1 with subnet mask 255.255.255.0

CLI FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (3)

Note: For a detailed CLI guide, visit docs.fortinet.com

FortiGate Cloud Key

(Connect a WAN port to the Internet)

  1. Go to forticloud.com and login with your FortiCloud Credentials or Register
  2. Follow the on-screen instructions, then click Add FortiGate
  3. Enter the FortiGate Cloud Key located on the sticker of your device

OVERVIEW

Front – FWF 80F-2R SeriesFORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (4) FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (5)

Rear – FWF 80F-2R SeriesFORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (6)

  1. 1 Grounding Screw additional protective earth connection, reserved for applications where a permanent local connection of protective earth is required
  2. Antenna Connection (SMA) passive directional antenna connection
  3. Console (RJ-45) CLI management computer interface
    USB (USB A) USB 3.0 server port
  4. SFP Shared Ports 1 & 2 (SFP) 1 Gbps SFP interface
  5. WAN Shared Ports 1 & 2 (RJ45) 1 Gbps Ethernet interface
  6. Ports 1 to 6 (RJ-45) 1 Gbps Ethernet interface
  7. FortiLink Ports A & B (RJ-45) 1 Gbps Ethernet interface
  8. Power Input 12V DC 5A, 100-240V AC 50/60Hz (optional redundant power adapter and cable available for purchase)

Front – FWF 81F-2R-POEFORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (7) FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (8)

Rear- FWF 81F-2R-POEFORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (9)

  1. Grounding Screw additional protective earth connection, reserved for applications where a permanent local connection of protective earth is required Antenna Connection (SMA) passive directional antenna connection
  2. Console (RJ-45) CLI management computer interface
  3. USB (USB A) USB 3.0 server port
  4. SFP Shared Ports 1 & 2 (SFP) 1 Gbps SFP interface
  5. WAN Shared Ports 1 & 2 (RJ45) 1 Gbps Ethernet interface
  6. Ports 1 to 6 (RJ-45) 1 Gbps Ethernet interface
  7. FortiLink Ports A & B (RJ-45) 1 Gbps Ethernet interface
  8. Power Input 54V DC 2.78A, 100-240V AC, 50/60Hz (optional redundant power adapter and cable available for purchase)

Front – FWF 81F-2R-3G4G-POEFORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (10) FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (11)

Rear – FWF 81F-2R-3G4G-POEFORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (12)

  1. Grounding Screw additional protective earth connection, reserved for applications where a permanent local connection of protective earth is required Antenna Connections (SMA) passive directional antenna connections
    (rear connectors are for 3G4G, side connectors are for WiFi; they use the same antennas)
  2. Console (RJ-45) CLI management computer interface
  3. USB (USB A) USB 3.0 server port
  4. SFP Shared Ports 1 & 2 (SFP) 1 Gbps SFP interface
  5. WAN Shared Ports 1 & 2 (RJ45) 1 Gbps Ethernet interface
  6. Ports 1 to 6 (RJ-45) 1 Gbps Ethernet interface
  7. FortiLink Ports A & B (RJ-45) 1 Gbps Ethernet interface
  8. Power Input 54V DC 2.78A, 100-240V AC, 50/60Hz (optional redundant power adapter and cable available for purchase)
  9. Sim Slot Nano Sim FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (13)

Front FWF 80F-2R-3G4G-DSLFORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (14) FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (15)

Rear – FWF 80F-2R-3G4G-DSLFORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (16)

  1. Grounding Screw additional protective earth connection, reserved for applications where a permanent local connection of protective earth is required Antenna Connections (SMA) passive directional antenna connections
    (rear connectors are for 3G4G, side connectors are for WiFi; they use the same antennas)
  2. Console (RJ-45) CLI management computer interface
  3. USB (USB A) USB 3.0 server port
  4. SFP Shared Ports 1 & 2 (SFP) 1 Gbps SFP interface
  5. WAN Shared Ports 1 & 2 (RJ45) 1 Gbps Ethernet interface
  6. Ports 1 to 6 (RJ-45) 1 Gbps Ethernet interface
  7. FortiLink Ports A & B (RJ-45) 1 Gbps Ethernet interface
  8. Power Input 12V DC 5A, 100-240V AC, 50/60Hz (optional redundant power adapter and cable available for purchase)
  9. Sim Slot Nano Sim FORTINET-FWF-80F-2R-Network-Securit-Firewall-Appliance-FIG- (17)

Cautions and Warnings

Environmental specifications

  • Ambient operating temperature: 0°C to 40°C
  • Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude)

Safety
Battery – Risk of explosion if the battery is replaced by an incorrect type. Do not dispose of batteries in a fire. They may explode. Dispose of used batteries according to your local regula-tions. IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries.

CAUTION:

  • There is a danger of explosion if a battery is incorrect replaced. Replace only with the same or equivalent type.
  • Dispose batteries of according to the manufacturer’s instructions.
  • Disposing a battery into fire, a hot oven, mechanically crushing, or cutting it can result in an explosion.
  • Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion.
  • If a battery is subjected to extremely low air pressure, it may result in leakage of flammable liquid, gas, or an explosion.

CAUTION: Shock Hazard. Disconnect all power sources.
This product is intended to be supplied by a Listed pluggable A via Class I external power supply adapter by means of a power cord connected to a socket-outlet with earthing connection. Ce produit est destiné à être alimenté par un adaptateur d’alimentation externe de classe I par l’intermédiaire d’un cordon d’alimentation enfichable de classe A qui doit être branché à une prise de courant avec terre.
Caution: This equipment is to be used in a Network Environment 0 per IECTR 62101. This product is connected only to PoE networks without routing to the outside plant.
This product has a separate protective earthing terminal provided on the back of the product in addition to the grounding terminal of the attachment plug. This separate protective earthing terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size #12AWG and the connection is to be installed by a qualified service personnel.
Disconnect ES2 (TNV) circuit connector before removing cover.
IMPORTANT SAFETY INSTRUCTIONS – When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

  • Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool.
  • Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.
  • Do not use the telephone to report a gas leak in the vicinity of the leak.
  • Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for possible special disposal instructions.

SAVE THESE INSTRUCTIONS

Warning: Equipment intended for installation in a Restricted Access Location.
CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG) UL Listed or CSA Certified Telecommunication Line Cord
Grounding — To prevent damage to your equipment, connections that enter from outside the building should pass through a lightning/surge protector, and be properly grounded. Use an electrostatic discharge workstation (ESD) and/or wear an anti-static wrist strap while you work. In addition to the grounding terminal of the plug, on the back panel, there is another, separate terminal for earthing.
This product has a separate protective earthing terminal provided on the back of the product in addition to the grounding terminal of the attachment plug. This separate protective earthing terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size # 12AWG and the connection is to be installed by a qualified service personnel.

Regulatory Notices

Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received; including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Model: FWF-80F-2R, FWF-81F-2R, FWF-80F-2R-3G4G-DSL, FWF-81F-2R-3G4G-DSL FWF-80F-2R-POE, FWF-81F-2R-POE, FWF-81F-2R-3G4G-POE
Caution: Operation of this device is restricted to indoor use only.
For operation within 5.15 ~ 5.25GHz frequency range, it is restricted to indoor environment
This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
This equipment complies with ANSI TIA/EIA/968-B and Part 68 of the FCC rules and the requirements adopted by the ACTA. On the base of this equipment is a label that contains, among other information, a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
This equipment uses the following USOC jacks: RJ11.
A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details.
The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined
by the total REN, contact the local telephone company. The REN for this product is separately shown on the label and also part of the product identifier that has the format US: AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3).
If you experience trouble with this equipment, for repair or warranty information, please refer to Fortinet’s End-User License Agreement which set forth the terms and limitation of Fortinet’s product warranty and contact the following address and phone number for additional information. Fortinet, Inc.
899 Kifer Road, Sunnyvale, CA 94086 USA 1-866-393-9960 (US and Canada) 1-613-725-2466 (International)
http://www.fortinet.com

It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges.
This equipment may not be used on coin service provided by the telephone company. Connection to party line service is subject to state tariffs.
Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada
This Class B digital apparatus complies with Canadian ICES-003.

Industry Canada (IC CS) – Canada
NOTICE: This product meets the applicable Industry Canada terminal technical specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada’s technical specifications were met. It does not guarantee the equipment will operate to the user’s satisfaction.
NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment is 0.1. The REN assigned to each terminal equipment indicates the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five.

Innovation, Science and Economic Development (ISED) – Canada
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Model: FWF-80F-2R, FWF-81F-2R, FWF-80F-2R-3G4G-DSL, FWF-81F-2R-3G4G-DSL FWF-80F-2R-POE, FWF-81F-2R-POE, FWF-81F-2R-3G4G-POE
For products available in the USA/Canada market, only channels 1~11 can be operated. Selection of other channels is not possible.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate.
The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit; and  (iii) where applicable, antenna type(s), antenna models(s), and worst-case tilt angle(s) necessary to remain compliant with the e.i.r.p. elevation mask requirement outlined in section 6.2.2.3 shall be indicated..
Caution: The device for the band 5150-5250 MHz is only for indoor usage to reduce the potential for harmful interference to co-channel mobile satellite systems.
Caution: The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit, and the maximum antenna gain permitted for devices in the band 5725-5825 MHz shall comply with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate
This radio transmitter (IC: 7280B-3417T0695A / Model: FWF-80F-2R, FWF-81F-2R, FWF-80F-2R-3G4G-DSL, FWF-81F-2R-3G4G-DSL) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
This radio transmitter (IC: 7280B-3417T0695A / Model: FWF-80F-2R-POE, FWF-81F-2R-POE, FWF-81F-2R-3G4G-POE) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
This device and it’s antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except by IC multi-transmitter product procedures.
Model: FWF-80F-2R, FWF-81F-2R, FWF-80F-2R-3G4G-DSL, FWF-81F-2R-3G4G-DSL FWF-80F-2R-POE, FWF-81F-2R-POE, FWF-81F-2R-3G4G-POE

Antenna Gain (dBi)
Type: Dipole Connector: SMA  

2400MHz

 

2450MHz

 

2500MHz

 

5150MHz

 

5600MHz

 

5850MHz

ANT1 2 3.24 2.64 3.27 2.01 1.58
ANT2 2 3.24 2.64 3.27 2.01 1.58
ANT3 2 3.24 2.64 3.27 2.01 1.58
Antenna Gain (dBi)
Type: PIFA Connector: IPEX  

2400MHz

 

2450MHz

 

2500MHz

BLE -2.76 0.74 -0.83

IMPORTANT: The device must be professionally installed and must use the supplied antenna.

Professional Installation Instruction

  1. Installation personnel
    This product is designed for specific application and needs to be installed by qualified personnel who has RF and related rule knowledge. The general user shall not attempt to install or change the settings.
  2. Installation location
    The product shall be installed at a location where the radiating antenna can be kept 20cm from a nearby person in normal operation conditions to meet Regulatory RF exposure requirements. The installation applies to indoor location.
  3. External antenna(s)
    Use only the antenna(s) that have been approved by the manufacturer. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power that may lead to the violation of FCC/ISED limit and is prohibited.
  4. Warning
    Please carefully select the installation position and ensure that the final output power does not exceed the limit outlined in the relevant rules. The violation of the rule could lead to serious federal penalties.

European Conformity (CE) – EU
This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

The product transmits within the frequency ranges and less than or equal to the power listed below:

Frequency Range (MHz) Transmit Power Less Than (dBm)
2402-2480MHz 20
2412-2472MHz 20**
5180-5240MHz 23**
5260-5320MHz 23*
5500-5700MHz 30*

Only with DFS bands certification. Applies to FortiWiFi 81F-2R Series
Applies to FortiWiFi 81F-2R Series
This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.

Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including combinations of software, firmware and hardware) provided by Fortinet or Fortinet’s authorized partners to the end-customer directly for use within the EU or countries that have implemented the EU Directives and/or spectrum regulation. Any Fortinet products not obtained directly from Fortinet or Fortinet’s authorized partners may not comply with EU Directives and Fortinet makes no assurances for such products.
This product complies with Directive 2014/53/EU.
Note: The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/EU
The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range in the following countries:
Compliance with 2014/53/EU Radio Equipment Directive (RED)
By Article 10.8(a) and 10.8(b) of the RED, the following table provides information on the frequency bands used and the maximum RF transmit power of the product for sale in the EU:

Standard Frequency Range Max Transmit Power dBm (EIRP)
Bluetooth 2402–2480 MHz 2.44
 

 

 

 

WLAN

2412–2472 MHz 19.84
5180–5240MHz 22.77
5260–5320 MHz 22.60
5500–5700 MHz 29.67
Standard Frequency Range Max Transmit Power dBm (Conducted)
 

 

WCDMA*

Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)  

 

25.7

Band 8: 880-915MHz(Uplink);925-960MHz(Downlink)
 

 

 

 

 

 

 

 

 

 

 

LTE*

Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)  

 

 

 

 

 

 

 

 

 

 

25.7

Band 3: 1710-1785MHz(Uplink); 1805~1880MHz(Downlink)
Band 7: 2500-2570MHz(Uplink); 2620~2690MHz(Downlink)
Band 8: 880-915MHz(Uplink);925-960MHz(Downlink)
Band 20: 832-862MHz(Uplink); 791~821MHz(Downlink)
Band 28: 703-748MHz(Uplink); 758~803MHz(Downlink)
Band 32: 1452-1496MHz(Downlink)
Band 42: 3400-3600MHz
Band 43: 3600-3800MHz
Band 46: 5150-5925MHz(Downlink)

UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to the power listed below:

Frequency Range (MHz) Transmit Power Less Than (dBm)
2402-2480MHz 20
2412-2472MHz 20
5180-5240MHz 23
5260-5320MHz 23*
5500-5700MHz 30*

Only with DFS bands certification.

Standard Frequency Range Max Transmit Power dBm (EIRP)
Bluetooth 2402–2480 MHz 2.44
 

 

 

 

WLAN

2412–2472 MHz 19.84
5180–5240MHz 22.77
5260–5320 MHz 22.60
5500–5700 MHz 29.67
Standard Frequency Range Max Transmit Power dBm (Conducted)
 

WCDMA*

Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)  

25.7

Band 8: 880-915MHz(Uplink);925-960MHz(Downlink)
 

 

 

 

 

 

 

LTE*

Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)  

 

 

 

 

 

 

25.7

Band 3: 1710-1785MHz(Uplink); 1805~1880MHz(Downlink)
Band 7: 2500-2570MHz(Uplink); 2620~2690MHz(Downlink)
Band 8: 880-915MHz(Uplink);925-960MHz(Downlink)
Band 20: 832-862MHz(Uplink); 791~821MHz(Downlink)
Band 28: 703-748MHz(Uplink); 758~803MHz(Downlink)
Band 32: 1452-1496MHz(Downlink)
Band 42: 3400-3600MHz
Band 43: 3600-3800MHz
Band 46: 5150-5925MHz(Downlink)

Applies to models FWF-80F-2R-3G4G-DSL, FWF-81F-2R-3G4G-DSL, FWF-81F-2R-3G4G-POE
This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.
This product complies with Statutory Instrument 1206 Radio Equipment Regulations 2017
The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/UK
The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range in the following countries:
Fortinet.com