FORTINET FGR-70G-5G Network Security Gateway User Guide

FGR-70G-5G Network Security Gateway

Specifications

  • Model: FortiGate Rugged 70G-5G
  • Dimensions: 122.0mm x 89.5mm x 139mm
  • Power Input: +12V to +125V DC, -12V to -125V DC

Product Usage Instructions

1. Power Installation

Warnings: Ensure you use a suitable wire gauge
and length for installation.

Connector Pinout:

  • Connect DC1+ or DC2+ on the device terminal block to the DC
    power source.
  • Connect the negative DC1- or DC2- on the terminal block.
  • Terminal block does not support hot-plugging.

2. Wiring

Connect DC1+ and DC2+ to the positive power source and DC1- and
DC2- to the negative power source within the specified voltage
range.

3. Grounding

It is optional but recommended to connect earth ground using the
lug plate or grounding screw for safety.

4. DIN Rail Mounting

Mount the device using the DIN Rail Bracket provided in the
package. Follow the side panel or rear panel position for
installation.

FAQ (Frequently Asked Questions)

Q: How do I access the device GUI?

A: Connect Port 1 to your computer using an Ethernet cable and
open a browser to https://192.168.1.99.

Q: What is the default login information?

A: Username: admin, Password: leave blank. Access through
https://192.168.1.99.

Q: How do I power the device?

A: Connect DC1+ or DC2+ to the DC power source and ensure proper
grounding as per the instructions.

“`

QuickStart Guide
FortiGate Rugged 70G-5G FGR-70G-5G

FGR-70G-5G-QSG-20250718.indd 1

7/22/2025 12:31:51 PM

FortiGate Rugged 70G-5G
The Essentials
Register at https://support.fortinet.com for the latest threat protection updates
GUI
1 Connect Port 1 to an Ethernet port or USB-RJ45 Ethernet adapter on your computer using the provided Ethernet cable
2 Open a browser to https://192.168.1.99
CLI
1 Connect a console cable (not included) to the Console Port 2 Open a Terminal app using 9600-8-N-1
Default Login
https://192.168.1.99 Username: admin Password: leave blank
Fortinet Documents Library
For getting started documentation, admin guides, up-to-date hardware manuals and reference resources, visit https://docs.fortinet.com/
FortiGate Cloud
Experience simplified cloud provisioning, security analytics, remote access, hosted log retention and reporting at https://fortigate.forticloud.com
FortiExplorer Go
Rapidly provision, deploy and manage your Fortinet Security Fabric Platform, free on iOS and Android: https://docs.fortinet.com/product/fortiexplorer-go/

2
FGR-70G-5G-QSG-20250718.indd 2

7/22/2025 12:31:51 PM

Package Contents
FortiGate Rugged 70G-5G FGR-70G-5G

QUICKSTART GUIDE

1x FGR-70G-5G

1x QuickStart Guide

1x CAT5e Ethernet Cable

1x DIN Rail Bracket w/Screws (4x M3x10)

1x Digital I/O Connector

1x DC Power Connector

5x Antennas (4x WWAN, 1x GPS)
FGR-70G-5G-QSG-20250718.indd 3

3
7/22/2025 12:31:52 PM

FortiGate Rugged 70G-5G
Power Installation
Warnings
· The redundant DC inputs support negative ground (+12V to +125V DC) and positive ground (-12V to -125V DC), 2.5A Max
· With the optional failover redundancy, if the primary DC input fails, the secondary DC input will supply power
· DC1+ and DC2+ are the higher voltage potential pins and DC1- and DC2- are the lower voltage potential pins
· Do not connect the DC+ terminal to a lower voltage potential than the DC- terminal
· The voltage between DC+ and DC- must be +12V to +125V DC · The DC wire gauge maximum is 12 AWG; the minimum is 22 AWG · Consult a professional electrician to install the device and determine a
suitable wire gauge and length
Connector Pinout
Connect DC1+ or DC2+ on the device terminal block to the DC power source, then connect the negative DC1- or DC2- on the terminal block. Terminal block does not support hot-plugging.

DC1- DC1+ DC2+ DC2-

DC Input Power Negative Ground Positive Ground

DC+ Terminal +12V to +125V DC
Ground

DC- Terminal Ground
-12V to -125V DC

4

FGR-70G-5G-QSG-20250718.indd 4

7/22/2025 12:31:52 PM

Wiring

QUICKSTART GUIDE

DC2DC2+ DC1+ DC1-

12-125V

IN1 DC1

DC2

DC1DC1+

DC2DC2+

Grounding
Optional but recommended, connect earth ground using the lug plate or grounding screw.

FGR-70G-5G-QSG-20250718.indd 5

5
7/22/2025 12:31:52 PM

FortiGate Rugged 70G-5G
Dimensions
NOTE: Drawings are for dimensional purposes only. Refer to the following pages for connector details.

122.0mm (4.80in)

89.5mm (3.52in)

139mm (5.47in)

6
FGR-70G-5G-QSG-20250718.indd 6

With connectors and terminal blocks 136.6mm (5.38in)
7/22/2025 12:31:53 PM

QUICKSTART GUIDE

90mm (3.54in)
48.3mm (1.90in)

10.5mm (0.41in)

205mm (8.07in)

25mm (.98in)

FGR-70G-5G-QSG-20250718.indd 7

7
7/22/2025 12:31:53 PM

FortiGate Rugged 70G-5G
DIN Rail Mounting Bracket

Side Panel Position

Rear Panel Position (Includes 4x M3 Pan Head Screws)

8
FGR-70G-5G-QSG-20250718.indd 8

7/22/2025 12:31:53 PM

59.50 20.00

89.5 44.00

QUICKSTART GUIDE 16.35

139

29.15 44.00

Rear Panel Position

FGR-70G-5G-QSG-20250718.indd 9

20.00

51.00

122

Side Panel Position 9

7/22/2025 12:31:53 PM

FortiGate Rugged 70G-5G
Digital I/O Connector

IN1+ REF IN2+ NC1 COM1 NO1 NC2 COM2 NO2

Connector NO2 COM2 NC2 NO1 COM1 NC1 IN2+ REF IN1+

Description Normally Open 2 Terminal
Common 2 Terminal Normally Closed 2 Terminal
Normally Open Terminal Common 1 Terminal
Normally Closed 1 Terminal Alarm Input 2
Alarm Input 1/2 Reference Ground Alarm Input 1

10
FGR-70G-5G-QSG-20250718.indd 10

7/22/2025 12:31:53 PM

QUICKSTART GUIDE
Dual 5G Nano SIM Slot
SIM type is 4FF – Nano SIM. Industrial SIM card recommended for extreme temperature environments. Refer to the datasheet for supported operating temperatures. For wireless configuration, visit https://docs.fortinet.com
SIM1 SIM2

FGR-70G-5G-QSG-20250718.indd 11

11
7/22/2025 12:31:53 PM

FortiGate Rugged 70G-5G
Setup
FortiExplorer Go

Install FortiExplorer Go

Enable Bluetooth

Follow the on-screen instructions

GUI
Port 1

UhtsNteporsn:P/a/a1ms9se2w:.1a6od8rdm.1.9in9

Ethernet Cable

If Static IP: 192.168.1.1/24

12
FGR-70G-5G-QSG-20250718.indd 12

7/22/2025 12:31:53 PM

QUICKSTART GUIDE

CLI

Console Port

USB Console Cable (available for purchase)

Speed (default): 9600

Data bits:

8

Stop bits:

1

Parity:

None

Flow Control: None

Management Computer

FGR-70G-5G-QSG-20250718.indd 13

13
7/22/2025 12:31:53 PM

FortiGate Rugged 70G-5G
Front FGR-70G-5G

1
ANT1

FortiGate Rugged 70G-5G GPS

ANT3

DC2DC2+ DC1+ DC1-
IN1+ REF IN2+ NC1 COM1 NO1 NC2 COM2 NO2

GPS SIM2 SIM1
5G

BLE

2 6
78

3
9
CONSOLE

SIM1

SIM2

4

OUT2 OUT1
10
BYPASS

SIGNED
FIRMWARE
L H 11

5
12-125V IN2 IN1 DC1
12
SFP1

DC2
13
SFP2

RST/ BLE
STA HA ALM PWR

ANT2

SERIAL

1/2

3/4 WAN1/WAN2
14

ANT0

1 Antenna Connector (5x SMA) 2 5G
Green: 5G connected Amber: 4G/3G connected Off: Not connected
3 5G SIM slots (2x Nano 4FF)

SIM1, SIM2 Green: SIM slot active Off: SIM slot inactive
GPS Green: On Off: Off

4 Alarm Inputs (IN1, IN2)
Green: Alarm defined Red: Alarm detected Off: Alarm not defined

Alarm Outputs (OUT1, OUT2)
Green: Alarm defined Flashing Red: Major alarm detected Red: Minor alarm detected Off: Alarm not defined

5 Power Connectors (DC1, DC2) Alarm disabled by default
Green: Power detected Red: Alarm is on; no power detected Off: No power detected

14

FGR-70G-5G-QSG-20250718.indd 14

7/22/2025 12:31:53 PM

QUICKSTART GUIDE

6 STA
Green: Operating normally Flashing Green: Reset window Off: Device is off
ALM Red: Major alarm detected Amber: Minor alarm detected Off: No alarm detected

HA Green: HA enabled (normal) Red: HA enabled (failover) Off: HA disabled
PWR Green: Power detected Off: Power not detected

7 RST / BLE Press to enable BLE; press and hold for system reset during STA reset window
BLE Blue: BLE on Flashing Blue: BLE in discovery Off: BLE off

8 USB 2.0 (USB-A)

9 CONSOLE (RJ45) CLI management

SERIAL (RJ45) Data port

10 Ports 1 to 4 (RJ45)

BYPASS Ports 1 & 2 only; bypass disabled by default

Green: Bypass off

Red: Bypass on

Speed (Left LED)

Activity/Link (Right LED)

Green: 1 Gbps Amber: 100 Mbps

Green: Link established Flashing Green: Data activity

Off: 10 Mbps or not connected

Off: No link established

11 SIGNED FIRMWARE BIOS Security Level Controlled by Signed Firmware Switch (covered), see Admin Guide at https://docs.fortinet.com High: Unsigned firmware blocked (default) Low: Unsigned firmware allowed with a warning
12 SFP1 & SFP2 (SFP) Green: Link established Flashing Green: Data activity Off: No link established
13 BLE Antenna

14 WAN1 (Top) & WAN2 (Bottom) (RJ45)
Speed (Left LED) Green: 1 Gbps Amber: 100 Mbps Off: 10 Mbps or not connected

Activity/Link (Right LED) Green: Link established Flashing Green: Data activity Off: No link established
15

FGR-70G-5G-QSG-20250718.indd 15

7/22/2025 12:31:53 PM

FortiGate Rugged 70G-5G
Cautions and Warnings
Environmental specifications
Ambient operating temperature: -40°C to 75°C
Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude) Référez à la Fiche Technique de ce produit pour les caractéristiques environnementales (Température de fonctionnement, température de stockage, humidité et l’altitude).
Safety
Warning: Equipment intended for installation in Restricted Access Location. Avertissement: Le matériel est conçu pour être installé dans un endroit où l’accès est restreint.
A skilled person must install the equipment. L’équipement doit être installé par une personne qualifiée.
Warning: A readily accessible disconnect device shall be incorporated in the building installation wiring. Avertissement: Un dispositif de déconnexion facilement accessible doit être incorporé dans l’installation électrique du bâtiment.
Warning: A UL Listed external disconnect device, i.e. circuit breaker or other, with over current protection suitable for local code(rated 15A recommended) shall be installed with this equipment Avertissement: Un dispositif de déconnection externe homologué UL, exemple d’un disjoncteur ou autre, avec des protections de surintensité appropriées (nominal 15A recommandé) à I’installation de ce matériel.
Battery ­ Risk of explosion if the battery is replaced by an incorrect type. Do not dispose of batteries in a fire. They may explode. Dispose of used batteries according to your local regulations. IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries.
Batterie ­ Risque d’explosion si la batterie est remplacée par un type incorrect. Ne jetez pas les batteries au feu. Ils peuvent exploser. Jetez les piles usagées conformément aux réglementations locales. IMPORTANT: Suisse: l’annexe 4.10 de SR814.013 s’appliquent aux batteries.

CAUTION: There is a danger of explosion if a battery is incorrect replaced. Replace only with the same or equivalent type. Dispose batteries of according to the manufacturer’s instructions. Disposing a battery into fire, a hot oven, mechanically crushing, or cutting it can result in an explosion. Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion. If a battery is subjected to extremely low air pressure, it may result in leakage of flammable liquid, gas, or an explosion.
WARNUNG: Lithium-Batterie Achtung: Explosionsgefahr bei fehlerhafter Batteriewechsel. Ersetzen Sie nur den gleichen oder gleichwertigen Typ. Batterien gemäß den Anweisungen des Herstellers entsorgen.
Beseitigung einer BATTERIE in Feuer oder einen heißen Ofen oder mechanisches Zerkleinern oder Schneiden einer BATTERIE, die zu einer EXPLOSION führen kann
Verlassen einer BATTERIE in einer extrem hohen Umgebungstemperatur, die zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder Gas führen kann
Eine BATTERIE, die einem extrem niedrigen Luftdruck ausgesetzt ist, der zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder Gas führen kann.
CAUTION: Shock Hazard. Disconnect all power sources. ATTENTION: Risque d’électrocution. Débranchez toutes les sources d’alimentation.
Grounding — To prevent damage to your equipment, connections that enter from outside the building should pass through a lightning / surge protector, and be properly grounded. Use an electrostatic discharge workstation (ESD) and/or wear an anti-static wrist strap while you work. In addition to the grounding terminal of the plug, on the back panel, there is another, separate terminal for earthing.
Mise à la terre — Pour éviter d’endommager votre matériel, assurez-vous que les branchements qui entrent à partir de l’extérieur du bâtiment passent par un parafoudre / parasurtenseur et sont correctement mis à la terre. Utilisez un poste de travail de décharge électrostatique (ESD) et / ou portez un bracelet anti-statique lorsque vous travaillez. Ce produit possède une borne de mise à la terre qui est prévu à l’arrière du produit, à ceci s’ajoute la mise à la terre de la prise.
This product has a separate protective earthing terminal provided on the back of the product in addition to the grounding terminal of the attachment plug. This separate protective earthing terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size # 20 AWG and the connection is to be installed by a qualified service personnel. Ce produit a une borne de mise à la terre séparé sur le dos de l’appareil, en plus de la borne de mise à la terre de la fiche de raccordement. Cette borne de mise à la terre séparée doit être connecté en permanence à la terre avec un conducteur vert avec la taille bande jaune de minimum # 20 AWG et la connexion doit être installé par un personnel qualifié.
Connect to NEC Class 2 power source Connectez-vous à une source d’alimentation NEC Classe 2
Regulatory Notices
Federal Communication Commission (FCC) ­ USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
WARNING: Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

16
FGR-70G-5G-QSG-20250718.indd 16

7/22/2025 12:31:54 PM

QUICKSTART GUIDE

Innovation, Science and Economic Development (ISED) ­ Canada

CAN ICES (A) / NMB (A)
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Cet appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicte par le ministère des Communications du Canada.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1. L’appareil ne doit pas produire de brouillage; 2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20cm de distance entre la source de rayonnement et votre corps.
This radio transmitter (IC: 7280B-21001T57) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (IC: 7280B-21001T57) a été approuvé par ISED pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
This device and it’s antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC multi-transmitter product procedures.
Cet appareil et son antenne (s) ne doit pas être co-localisés ou fonctionnement en association avec une autre antenne ou transmetteur.

Antenna type Connector Gain (dBi)

Monopole

I-PEX

1.53

Network Bluetooth

European Conformity (CE) – EU
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

The product transmits within the frequency ranges and less than or equal to the power listed below:

Standard Bluetooth

Frequency Range 2402­2480 MHz

Transmit Power Less than 10 dBm (EIRP)

Standard WCDMA
LTE
5G NR

Frequency Range
Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) Band 8: 880-915MHz(Uplink);925-960MHz(Downlink)
Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) Band 3: 1710-1785MHz(Uplink); 1805-1880MHz(Downlink) Band 7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink) Band 8: 880-915MHz(Uplink);925-960MHz(Downlink) Band 20: 832-862MHz(Uplink); 791-821MHz(Downlink) Band 28: 703-748MHz(Uplink); 758-803MHz(Downlink) Band 34: 2010-2025MHz Band 38: 2570-2620MHz Band 40: 2300-2400MHz Band 41: 2496-2690MHz Band 42: 3400-3600MHz Band 43: 3600-3800MHz
Band 41: 2496-2690MHz
n1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) n3: 1710-1785MHz(Uplink); 1805-1880MHz(Downlink) n7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink) n8: 880-915MHz(Uplink);925-960MHz(Downlink) n20: 832-862MHz(Uplink); 791-821MHz(Downlink) n28: 703-748MHz(Uplink); 758-803MHz(Downlink) n38: 2570-2620MHz n40: 2300-2400MHz n41: 2496-2690MHz n77: 3300-4200MHz n78: 3300-3800MHz
n41: 2496-2690MHz n77: 3300-4200MHz n78: 3300-3800MHz

Transmit Power 24 dBm (Conducted) 24 dBm (Conducted) 27 dBm (Conducted) 24 dBm (Conducted)
29 dBm (Conducted)

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including combinations of software, firmware and hardware) provided by Fortinet or Fortinet’s authorized partners to the end-customer directly for use within the EU or countries that have implemented the EU Directives and/or spectrum regulation. Any Fortinet products not obtained directly from Fortinet or Fortinet’s authorized partners may not comply with EU Directives and Fortinet makes no assurances for such products.

2014/53/.

Cesky

17

Tento produkt je v souladu se smrnicí 2014/53/EU.

FGR-70G-5G-QSG-20250718.indd 17

7/22/2025 12:31:54 PM

FortiGate Rugged 70G-5G
Dansk Dette produkt er i overensstemmelse med direktiv 2014/53/EU.
Deutsch Dieses Produkt entspricht der Richtlinie 2014/53/EU.
Eesti See toode vastab direktiivile 2014/53/EL.
English This product is in compliance with Directive 2014/53/EU.
Español Este producto cumple con la Directiva 2014/53/UE.
2014/53/.
Français Ce produit est conforme à la Directive 2014/53/UE.
Hrvatski Ovaj proizvod je u skladu s Direktivom 2014/53/EU.
Italiano Questo prodotto è conforme alla Direttiva 2014/53/EU.
Latviski Sis produkts atbilst Direktvai 2014/53/ES.
Lietuvi Sis gaminys atitinka direktyv 2014/53/ES.
Malti Dan il-prodott huwa konformi mad-Direttiva 2014/53/UE.
Magyar Ez a termék megfelel a 2014/53/EU irányelvnek.
Nederlands Dit product is in overeenstemming met Richtlijn 2014/53/EU.
Norsk Dette produktet er i samsvar med direktiv 2014/53/EU.
Polski Ten produkt jest zgodny z dyrektyw 2014/53/UE.
Português Este produto está em conformidade com a Diretiva 2014/53/UE.
Rumunski Acest produs este în conformitate cu Directiva 2014/53/UE.
Slovensky Tento produkt je v súlade so smernicou 2014/53/EÚ.
Slovensko Ta izdelek je v skladu z Direktivo 2014/53/EU.
Suomi Tämä tuote on direktiivin 2014/53/EU mukainen.
Svenska Denna produkt överensstämmer med direktiv 2014/53/EU.
Note: The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/EU

18
FGR-70G-5G-QSG-20250718.indd 18

7/22/2025 12:31:54 PM

UK Conformity Assessed (UKCA) ­ United Kingdom

The product transmits within the frequency ranges and less than or equal to the power listed below:

Standard Bluetooth

Frequency Range 2402­2480 MHz

Transmit Power Less than 10 dBm (EIRP)

Standard WCDMA
LTE
5G NR

Frequency Range
Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) Band 8: 880-915MHz(Uplink);925-960MHz(Downlink)
Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) Band 3: 1710-1785MHz(Uplink); 1805-1880MHz(Downlink) Band 7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink) Band 8: 880-915MHz(Uplink);925-960MHz(Downlink) Band 20: 832-862MHz(Uplink); 791-821MHz(Downlink) Band 28: 703-748MHz(Uplink); 758-803MHz(Downlink) Band 34: 2010-2025MHz Band 38: 2570-2620MHz Band 40: 2300-2400MHz Band 41: 2496-2690MHz Band 42: 3400-3600MHz Band 43: 3600-3800MHz
Band 41: 2496-2690MHz
n1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) n3: 1710-1785MHz(Uplink); 1805-1880MHz(Downlink) n7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink) n8: 880-915MHz(Uplink);925-960MHz(Downlink) n20: 832-862MHz(Uplink); 791-821MHz(Downlink) n28: 703-748MHz(Uplink); 758-803MHz(Downlink) n38: 2570-2620MHz n40: 2300-2400MHz n41: 2496-2690MHz n77: 3300-4200MHz n78: 3300-3800MHz
n41: 2496-2690MHz n77: 3300-4200MHz n78: 3300-3800MHz

Transmit Power 24 dBm (Conducted) 24 dBm (Conducted) 27 dBm (Conducted) 24 dBm (Conducted)
29 dBm (Conducted)

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
This product is in compliance with Statutory Instrument 1206 Radio Equipment Regulations 2017.
The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/UK

QUICKSTART GUIDE

FGR-70G-5G-QSG-20250718.indd 19

19
7/22/2025 12:31:54 PM

www.fortinet.com
July 21, 2025
Copyright © 2025 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties, whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinet’s SVP Legal and above, with a purchaser that expressly warrants that the identified product will perform according to certain expressly-identified performance metrics and, in such event, only the specific performance metrics expressly identified in such binding written contract shall be binding on Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet’s internal lab tests. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied. Fortinet reserves the right to change, modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable.
For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf
FGR-70G-5G-QSG-20250718

FGR-70G-5G-QSG-20250718.indd 20

7/22/2025 12:31:54 PM

Documents / Resources

FORTINET FGR-70G-5G Network Security Gateway [pdf] User Guide
FGR-70G-5G, TVE-21001T57, TVE21001T57, 21001t57, FGR-70G-5G Network Security Gateway, FGR-70G-5G, Network Security Gateway, Security Gateway, Gateway

References

Leave a comment