LinkIQ Cable Plus Network Tester
“
Product Information
Specifications:
- Product Name: LinkIQTM/LinkIQTM Duo Cable+Network Tester
- Manufacturer: Fluke Corporation
- Warranty: 1-Year Limited Warranty
- Power Supply: Fluke Networks approved power adapters
- Battery Type: Lithium-ion battery
- Usage: Indoor use only
Product Usage Instructions
Safety Information:
Before using the Product, ensure you read all safety information
and instructions provided in the User Manual. Failure to follow
these instructions may result in electrical shock, fire, or
personal injury.
Battery Usage:
Replace the rechargeable battery after 5 years of moderate use
or 2 years of heavy use. Moderate use is defined as recharged twice
a week, while heavy use is defined as discharged to cutoff and
recharged daily. Do not disassemble the battery or expose it to
heat, fire, or sunlight.
Product Operation:
To activate the input protection circuitry, turn on the Product
before connecting a cable. Do not connect or disconnect a cable
during a test to prevent any issues.
Maintenance:
If the Product operates incorrectly, do not use it and have an
approved technician repair it. Follow proper disposal guidelines
for spent batteries to protect the environment.
Power Supply:
Use only Fluke Networks approved power adapters to charge the
battery and ensure proper functioning of the Product.
FAQ (Frequently Asked Questions)
Q: How often should I replace the rechargeable battery?
A: Replace the rechargeable battery after 5 years of moderate
use or 2 years of heavy use.
Q: Can I use any power adapter to charge the battery?
A: No, use only Fluke Networks approved power adapters to charge
the battery and maintain product safety.
Q: What should I do if the Product operates incorrectly?
A: Do not use the Product and contact an approved technician for
repair.
“`
LinkIQTM/LinkIQTM Duo
Cable+Network Tester
Safety Information
1-Year Limited Warranty. See the Users Manual for the full warranty.
Contact Fluke Corporation
Fluke Corporation operates worldwide. For local contact information, go to our website: www.flukenetworks.com.
To register your product, or to view, print, or download the latest manual or manual supplement, go to our website.
Fluke Corporation 6920 Seaway Blvd Everett WA 98203 U.S.A.
Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands
+1-425-446-5500 info@flukenetworks.com
A Warning identifies hazardous conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test.
Warning
To prevent possible electrical shock, fire, or personal injury: Read all safety information before you use the Product. Carefully read all instructions. Do not alter the Product and use only as specified, or the protection
supplied by the Product can be compromised. Do not use the Product if it operates incorrectly.
*5241339*
PN 5241339 (English) 10/2020 Rev. 5, 11/2024 ©2020-2024 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
Do not use the Product if it is altered or damaged.
The tester is not intended to be connected to active telephone inputs, systems, or equipment, including ISDN devices. Exposure to the voltages applied by these interfaces may damage the tester and create a potential shock hazard.
Use caution when working in potentially hazardous locations such as an elevated location on a ladder or roof top, especially if work is occurring in proximity to a lightning storm. Also use caution if external communication cables are run at length in parallel to electrical power installation cables. These types of installations may expose communication cables to coupled electrical transients that could be accessible on exposed conductive parts of the equipment during operation. While in general these transients are not expected to be an electric shock hazard, startle reaction from these transients could lead to a secondary hazard such as loss of balance and lead to a fall or other injury. To reduce risk of exposure, limit contact to accessible conductive parts of I/O terminals during operation.
Use only Fluke Networks approved power adapters to charge the battery.
Batteries contain hazardous chemicals that can cause burns or explode. If exposure to chemicals occurs, clean with water and get medical aid.
Do not disassemble the battery.
Do not put battery cells and battery packs near heat or fire. Do not put in sunlight.
Do not disassemble or crush battery cells and battery packs.
Do not short the battery terminals together.
Use only the external mains power supply included with the Product.
Disconnect the battery charger and move the Product or battery to a cool, non-flammable location if the rechargeable battery becomes hot (>50 °C) during the charge period.
Replace the rechargeable battery after 5 years of moderate use or 2 years of heavy use. Moderate use is defined as recharged twice a week. Heavy use is defined as discharged to cutoff and recharged daily.
To activate the input protection circuitry of the Product, turn on the Product before you connect a cable to the Product.
During a test, do not connect a cable to the Product.
During a test, do not disconnect a cable from the Product.
Have an approved technician repair the Product.
Use this Product indoors only.
Symbols
The table below lists the symbols that can be used on the Product or in this document.
Symbol
Description Consult user documentation.
WARNING. RISK OF DANGER.
WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.
Conforms to European Union directives.
This Product contains a lithium-ion battery. Do not mix with the solid waste stream. Spent batteries should be disposed of by a qualified
recycler or hazardous materials handler per local regulations. Contact your authorized Fluke Service Center for recycling information.
This product complies with the WEEE Directive marking
requirements. The affixed label indicates that you must not discard
this electrical/electronic product in domestic household waste.
Product Category: With reference to the equipment types in the
WEEE Directive Annex I, this product is classed as category 9
“Monitoring and Control Instrumentation” product. Do not dispose
of this product as unsorted municipal waste.
Specifications
Size Weight Battery
Ac adapter Input Output
Temperature Operating Storage Charging
Altitude Operating Storage
114 mm x 213 mm x 48 mm <1 kg Lithium-ion, 23 Whr, 3.6 V, 6.4 Ahr, configuration 1ICR19/66-2 Class II 100 V ac to 240 V ac ±10 %, 50/60 Hz 5 V dc, 2 A max
0 °C to 45 °C -20 °C to 50 °C 0 °C to 40 °C
4000 m 12 000 m
Relative humidity
0 % to 90 %, 0 °C to 35 °C 0 % to 70 %, 35 °C to 45 °C Uncontrolled: <0 °C non-condensing
Wireless radio
Frequency range
Output power
Note The complete frequency range may not be available in all countries.
China, Mexico 2400 MHz to 2483.5 MHz
20 dBm (EIRP)
5150 MHz to 5250 MHz
23 dBm (EIRP)
5725 MHz to 5850 MHz
33 dBm (EIRP)
Taiwan
2400 MHz to 2483.5 MHz
20 dBm (EIRP)
5150 MHz to 5850 MHz
33 dBm (EIRP)
5925 MHz to 6425 MHz
33 dBm (EIRP)
Other locales 2400 MHz to 2483.5 MHz
20 dBm (EIRP)
5150 MHz to 5850 MHz
33 dBm (EIRP)
5925 MHz to 7150 MHz
36 dBm (EIRP)
Safety
IEC 61010-1: Pollution Degree 2
Electromagnetic Compatibility (EMC)
International
IEC 61326-1: Basic Electromagnetic Environment, CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)
47 CFR 15 Intentional Radiators: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including inteSrference that may cause undesired operation. (15.19). Changes or modifications not expressly approved by Fluke could void the user’s authority to operate the equipment. (15.21)
Documentation and Software Licensing Notice
CDs or other computer media are no longer included in the box. For user documentation, go to www.flukenetworks.com/products. For products containing software licensed under the GNU General Public License (GPL) or Lesser GNU General Public License (LGPL), the complete corresponding sources are available. You can order a complete machine-readable copy of the source code from Fluke Corporation for a period of three (3) years after receipt of the product. Send a written request to: Open Source Request Fluke Corporation 6920 Seaway Blvd Everett, WA 98203 Please include:
Your full name Your company name Product model, serial number, and software revision level Your return mailing address Your email address (if available) NOTE: Fluke may charge a fee to cover the cost of this distribution. This offer is valid to anyone in receipt of this information.
Download the latest version of the software licensing information and Open Source files at https://www.flukenetworks.com/support/downloads.
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: www.fluke.com/red.
Documents / Resources
![]() |
FLUKE networks LinkIQ Cable Plus Network Tester [pdf] Instructions LinkIQ, LinkIQ Cable Plus Network Tester, Cable Plus Network Tester, Network Tester, Tester |