First Co VMBE Series Variable Speed High Efficiency Variable Speed Motor Instruction Manual
First Co VMBE Series Variable Speed High Efficiency Variable Speed Motor

The VMBE Series includes a programmable, high efficiency motor that redefines comfort and energy savings.

The VMBE Series includes a programmable, high efficiency motor that redefines comfort and energy savings. The VMBE motor automatically adjusts its torque and speed to maintain a preprogrammed level of constant airflow over a wide range of external static pressures. This variable speed technology offers better indoor air quality, more precise humidity control, quieter operation, consistent indoor air temperature, and lower utility bills.

High Efficiency – At full load conditions the VMBE motor is 20% more efficient than an induction motor and at constant fan speed it consumes only 60-80 watts of power compared to 400 watts for a standard induction motor
High Efficiency

Quiet Operation – The versatile VMBE motor quietly “ramps up” when the unit is turned on and “ramps down” when the thermostat is satisfied, eliminating the annoying sounds of changing airflow.

Self-Regulating Constant Airflow – The VMBE motor is factory programmed to maintain a predetermined level of airflow over a wide range of external static pressures, ensuring optimum system performance and whole-house comfort. The benefits of constant fan operation are:

  • Consistent air distribution (and temperature) throughout the home
  • Better indoor air quality (further improved with the addition of high efficiency filter) – This allows the air to be filtered without excessive drafts and without sacrificing efficiency.
  • Better humidity control – The VMBE is designed to  extract much more moisture from the air than a conventional system by slowing the airflow over the cooling coil. The result is an improved summer comfort level at higher indoor temperatures.

Variable Speed ECM Motor

Variable Speed ECM Motor

PHYSICAL DIMENSIONS
UNIT MODEL A B C D E F G H FILTER SIZE
8VMBE 40 20 20 18-1/2 16 2 18 16 18 X 20 X 1
12VMBE 42 23 20 21-1/2 16 2 18 17 20 X 22 X 1
16/20VMBE 48 28 21-1/4 26-1/4 17-1/4 2 19-1/4 18 20 X 25 X 1

Product Overawe

AIR FLOW DATA (see “heating select taps” below each table for proper field set-up)
 

 

MODEL

 

 

OPERATING MODE

THERMOSTAT TERMINALS CONTROL BOARD SELECT TAPS
 

COOL TAP

HEAT TAP
“X” ENERGIZED TERMI- NALS
(See notes below)
Y1 G W1 A B C D A B C D
 

 

8VMBE

COOLING X X   800 720 600 525        
CONTINUOUS BLOW- ER   X   400 360 300 265        
ELECTRIC HEAT     X         790 730 660 600
Heating Select Taps

800 CFM unit with 0 – 15kW electric heat

800 CFM unit with 0 – 5kW max. electric heat

600 CFM unit with 0 – 10kW electric heat

600 CFM unit with 0 – 5kW max. electric heat

 
 

 

12VMBE

COOLING X X   1200 1050 950 850        
CONTINUOUS BLOW- ER   X   600 525 475 425        
ELECTRIC HEAT     X         1130 1000 875 790
Heating Select Taps

1200 CFM unit with 0 – 15kW electric heat

1200 CFM unit with 0 – 10kW max. electric heat

950 CFM unit with 0 – 10kW electric heat

950 CFM unit with 0 – 5kW max. electric heat

 
 

 

16VMBE

COOLING X X   1600 1400 1250 1100        
CONTINUOUS BLOW- ER   X   800 700 625 550        
ELECTRIC HEAT     X         1500 1360 1190 1060
Heating Select Taps

A+10% 1600 CFM unit with 20kW electric heat

A 1600 CFM unit with 10 – 20kW max. electric heat B 1600 CFM unit with 0 – 10kW max. electric heat C 1250 CFM unit with 10 – 15kW electric heat

D 1250 CFM unit with 0 – 10kW max. electric heat

 
 

 

20VMBE

COOLING X X   1825 1700 1600 1400        
CONTINUOUS BLOW- ER   X   900 850 800 700        
ELECTRIC HEAT     X         1825 1700 1500 1300
Heating Select Taps

2000 CFM unit with 15 – 20kW electric heat

2000 CFM unit with 0 – 15kW max. electric heat

1600 CFM unit with 10 – 20kW electric heat

1600 CFM unit with 0 – 10kW max. electric heat

Airflow shown are dry coil at 230 volts.
Max. ext. static pressure is 0.50″ wtr

Notes: The cooling and heating speed taps are factory set on “A”. The delay profile is factory set on “A” (Arid setting). The adjust profile is factory set on Normal. If humidistat function is activated the cooling CFM will be reduced by 20%. Adjust profile (+) will increase airflow by 10%, while tap (-) will decrease airflow by 10%.

For additional sales and technical information on variable speed motors visit: www.thedealertoolbox.com

Digital thermostats for these units must have a “C” terminal.

Symbol
In keeping with its policy of continuous progress and product improvement, First Operations reserves the right to make changes without notice. Maintenance for all First Co. products is available under “Product Maintenance” at www.firstco.com.

PERFORMANCE DATA – 230V CIRCUIT 1 CIRCUIT 2 CIRCUIT 3
 

UNIT MODEL

 

kW (@ 230V)

 

MOTOR AMPS

MO- TOR HP L1 – L2 TOTAL AMPS 230V/208V L1 – L2 MIN. CIR. AMPACITY 230V/208V L1 – L2 MAX. CIR.

PROTECTION 230V/208V

L3 – L4 TOTAL AMPS 230V/208V L3 – L4 MIN. CIR. AMPACITY 230V/208V L3 – L4 MAX. CIR.

PROTECTION 230V/208V

L5 – L6 TOTAL AMPS 230V/208V L5 – L6 MIN. CIR. AMPACITY 230V/208V L5 – L6 MAX. CIR.

PROTECTION 230V/208V

8VMBE0 0 1.9 1/3 1.9 3/3 15/15
8VMBE3 3 1.9 1/3 15/13 18/16 20/20
8VMBE4 4 1.9 1/3 17/15 24/20 25/20
8VMBE5 5 1.9 1/3 21/18 29/25 30/25
8VMBE6 6 1.9 1/3 25/22 36/30 40/30
8VMBE8 8 1.9 1/3 33/29 46/39 50/40
8VMBE10 10 1.9 1/3 42/36 55/48 60/50
12VMBE0 0 2.8 1/2 2.8 4/4 15/15
12VMBE5 5 2.8 1/2 24/21 30/26 30/30
12VMBE8 8 2.8 1/2 36/32 46/40 50/40
12VMBE10 10 2.8 1/2 45/39 56/49 60/50
12VMBE15 15 2.8 1/2 45/39 56/49 60/50 21/18 27/23 30/25
16VMBE0 0 4.7 3/4 4.7 6/6 15/15
16VMBE5 5 4.7 3/4 26/23 32/29 35/30
16VMBE8 8 4.7 3/4 33/29 48/42 50/45
16VMBE10 10 4.7 3/4 46/41 58/50 60/50
16VMBE15 15 4.7 3/4 46/41 58/50 60/50 21/18 27/23 30/25
16VMBE20 20 4.7 3/4 46/41 58/50 60/50 42/36 53/46 60/50
20VMBE0 0 7.1 1 7.1 9/9 15/15
20VMBE5 5 7.1 1 28/26 36/32 40/35
20VMBE8 8 7.1 1 41/36 52/46 60/50
20VMBE10 10 7.1 1 47/42 59/53 60/60
20VMBE15 15 7.1 1 47/42 59/53 60/60 21/18 27/23 30/25
20VMBE20 20 7.1 1 47/42 59/53 60/60 42/36 53/46 60/50

NOTES:

  1. 15kW and 20kW models require 2 supply circuits.
  2. Units suitable for installation with 0” clearance to combustible material.
CHILLED WATER COOLING CAPACITY – 4 ROW
 

 

UNIT MODEL

 

 

CFM

 

 

GPM

 

P.D.

(FT.

WTR.)

45oF ENTERING WATER 42oF ENTERING WATER
80oF DB/67oF WB ENT. AIR 75oF DB/63oF WB ENT. AIR 80oF DB/67oF WB ENT. AIR 75oF DB/63oF WB ENT. AIR
TOTAL MBH SENS. MBH TEMP. RISE TOTAL MBH SENS. MBH TEMP. RISE TOTAL MBH SENS. MBH TEMP. RISE TOTAL MBH SENS. MBH TEMP. RISE
 

 

 

8VMBE

 

600

3.0

4.5

6.0

2.5

5.5

9.5

19.0

22.4

24.4

13.8

15.1

15.9

12.7

9.9

8.2

14.5

17.1

18.7

12.1

13.1

13.7

9.7

7.6

6.2

20.7

24.4

26.6

14.4

15.9

16.8

13.8

10.8

8.9

15.8

18.6

20.3

12.6

13.7

14.4

10.5

8.3

6.8

 

800

3.5

5.0

6.5

3.4

6.7

11.0

23.1

26.9

29.2

17.3

18.7

19.6

13.2

10.7

9.0

17.6

20.5

22.3

15.2

16.3

17.0

10.1

8.2

6.9

25.2

29.3

31.8

18.1

19.6

20.6

14.4

11.7

9.8

19.2

22.4

24.3

15.8

17.1

17.8

11.0

8.9

7.5

 

 

 

12VMBE

 

1000

4.0

6.0

8.0

2.4

4.8

7.9

28.3

33.9

37.3

21.6

23.7

25.0

14.1

11.3

9.3

21.6

25.9

28.5

19.0

20.6

21.7

10.8

8.6

7.1

30.8

36.9

40.6

22.5

24.8

26.3

15.4

12.3

10.2

23.6

28.2

31.0

19.7

21.6

22.7

11.8

9.4

7.8

 

1200

5.0

6.5

8.0

3.5

5.5

7.9

33.7

38.0

41.0

25.5

27.1

28.2

13.5

11.7

10.3

25.8

29.1

31.3

22.4

23.7

24.6

10.3

8.9

7.8

36.8

41.5

44.7

26.6

28.4

29.6

14.7

12.8

11.2

28.1

31.7

34.1

23.3

24.7

25.7

11.3

9.7

8.5

 

 

 

16VMBE

 

1400

4.5

6.0

7.5

2.0

3.3

4.8

36.2

42.4

46.9

29.2

31.4

33.1

16.1

14.1

12.5

27.7

32.4

35.8

25.8

27.6

28.9

12.3

10.8

9.6

39.5

46.2

51.1

30.3

32.8

34.7

17.5

15.4

13.6

30.1

35.3

39.0

26.7

28.7

30.2

13.4

11.8

10.4

 

1600

6.0

8.0

10.0

3.3

5.4

7.9

44.2

51.0

55.7

34.1

36.6

38.4

14.7

12.7

11.1

33.8

38.9

42.5

30.0

32.0

33.4

11.3

9.7

8.5

48.2

55.5

60.7

35.5

38.3

40.3

16.1

13.9

12.1

36.8

42.4

46.3

31.2

33.4

34.9

12.3

10.6

9.3

 

 

 

20VMBE

 

1600

6.5

8.5

10.5

3.8

6.0

8.6

46.1

52.3

46.6

34.8

37.1

38.7

14.2

12.3

10.8

35.2

39.9

43.2

30.6

32.4

33.7

10.8

9.4

8.2

50.3

57.0

61.7

36.3

38.8

40.7

15.5

13.4

11.8

38.4

43.5

47.1

31.8

33..8

35.2

11.8

10.2

9.0

 

2000

7.0

10.0

13.0

4.3

7.9

12.5

52.4

61.7

67.5

40.9

44.3

46.5

15.0

12.3

10.4

40.0

47.1

51.6

36.1

38.8

40.5

11.4

9.4

7.9

57.1

67.3

73.6

42.6

46.4

48.8

16.3

13.5

11.3

43.6

51.4

56.2

37.4

40.5

42.4

12.5

10.3

8.6

3-WAY AIRFLOW 

Installations

(Standard Harizontal Position)
Standard Harizontal Position

(Alternate Horiziontal Position)  ( Field convertible )

Field convertible

Power Head
Valve Body
CP905

ACCESSORIES: (for chilled water coil)
Power Heads:
E50131180 24V
Separate Valve Bodies: (order power heads separately) (mount outside cabinet)
E421317 E431317 E421417 E431417 3/4″ 2-way – For 8-12VMBE-2773/4″ 3-way – For 8-12VMBE-2771″ 2-way – For 16-20VMBE-2771″ 3-way – For 16-20VMBE-277
Hand Valves: (Combination balance / shut-off) (2 usually req’d per coil)
CP90 CP905 For 8-12VMBE-277 For 16-20VMBE-277

NOTE:

  1. Power head leads are 18”.

Warning iconWARNING AVERTISSEMENT ADVERTENCIA Cancer and Reproductive Harm Cancer et Troubles de l’appareil reproducer Cancer y Dart° Reproductivo www.P65Warnings.ca.flOVLOYOOS7

Power Head

CP905
Valve Body

ACCESSORIES: (field installed) (all components mount outside the cabinet)
POWER HEADS:
E50131180 24V
SEPARATE VALVE BODIES: (order power heads separately)
E421317 E431317 E421417 E431417 3/4″ 2-way – For 8-12VMB3/4″ 3-way – For 8-12VMB1″ 2-way – For 16-20VMB1″ 3-way – For 16-20VMB
HAND VALVES: (Combination balance / shut-off) (2 usually req’d per coil)
CP90 CP905 3/4″ – For 8-12VMB1″ – For 16-20VMB

NOTE:

  1. Power head leads are 18”.

FIRST CO.
P.O. BOX 270969 – DALLAS, TEXAS 75227
PH. 214-388-5751 | SALES@FIRSTCO.CO
WWW.FIRSTCO.COM

FISST EA LOGO

Documents / Resources

First Co VMBE Series Variable Speed High Efficiency Variable Speed Motor [pdf] Instruction Manual
VMBE Series Variable Speed High Efficiency Variable Speed Motor, VMBE Series, Variable Speed High Efficiency Variable Speed Motor, Speed High Efficiency Variable Speed Motor, High Efficiency Variable Speed Motor, Efficiency Variable Speed Motor, Variable Speed Motor, Speed Motor, Motor

References

Leave a comment

Your email address will not be published. Required fields are marked *