FIELDCONTROLS FCPV Fresh Command Ventilation System
DESCRIPTION
The FCPV is an intelligent, automatic, year-round ventilation system that integrates with an existing HVAC system and thermostat to meet ASHRAE 62.2 requirements.
ITEMS INCLUDED IN KIT
- Fresh Air Power Ventilator (FAPV-180AC)
- Fresh Command Multi Family Control (FCMC)
- Mounting Hole Template
- Instruction Manual
- MERV-6 Washable Filter
- Mounting Brackets (2)
- Mounting Packet containing Sheet Metal Screws
REPLACEMENT PARTS
Description | Part Number |
FAPV-Pre filter | 602604700 |
Motorized Impeller | 602604800 |
Electronic Speed Control | 04312200 |
24VAC Relay | 46161400 |
8 Microfarad Motor Capacitor | 602604900 |
FAPV FEATURES
- Electronic Speed Control with readily accessible Off switch
- Continuous or intermittent Ventilation options
- Passive air flow-operated backdraft damper
- Included MERV6 Washable Air Filter
- Internal Slot for easy slide-in installation of a standard 10”x10”x2” air fi liter
- ETL Listed
FCMC FEATURES
- Complies to ASHRAE 62.2 with built-in
calculations for easy setup and installation - Auto-senses 8 key factors at startup to balance temperature and humidity regardless of climate zone
- Built-in temperature and humidity sensors with no additional wiring needed
- Quick-Start Test feature for an immediate test cycle
- Fast Click, lock cover deters tenant or renter interference
- Seeks to ventilate with a heating or cooling call for optimal comfort and efficiency
- One dial to adjust intermittent ventilation• On/off switch with easy access that does not require cover removal
FAPV PRODUCT SPECIFICATIONS
Motorized Impeller Specifications | PSC Motor Class F Insulated Thermally protected UL, CSA recognized Impeller rated UL 94-5VA flam- mobility Sealed ball bearings Nominal RPM: 2600 |
Power Supply | 115 VAC, 60 Hz |
Watts (mx speed) | 85W |
Amps (max speed) | 0.90A |
Temperature Range | -22 to 140°F Ambient Outdoor Temperature |
Control Voltage (optional) | 24 VAC |
Air Flow Range | 30 to 220 cfm @ 0.20 Static Pressure |
Filtration | MERV 6, Washable, UL-900 rated |
FCMC PRODUCT SPECIFICATIONS
Power Requirements (Class 2 Appliance)
Power | |
Input Voltage | 16-32 VAC |
Full Load Power | 1.28W 27.4VAC |
Idle Power | 270mW @ 27.4 VAC |
Wiring Requirements | 18-22 AWG, 24 VAC (Min) |
Operating Temperature Range | 10°F to 160°F |
Operating Humidity Range | 5 to 95% RH (non-condensing) |
Outputs | |
Fan Output GF (Maximum Load Current) | 8A inductive @30VAC |
Vent (V,V) (Maximum Load Current) | 8A inductive @30VAC, or 30ADC |
Field Controls LLC reserves the right to modify a product, without prior notice, whether in design, color or specifications, in order to offer at all times a quality product that is highly competitive. Please consult your national and local building codes to find out whether the installation of electrical products requires the services of a certified technician or electrician. Field Controls is a registered Trademark used under license by Field Controls LLC. All rights reserved.
DIMENSIONAL DATA
INSTALLATION
MECHANICAL CLOSET TYPICAL INSTALLATION
WIRING DIAGRAM OF TYPICAL INSTALLATION
CUSTOMER SUPPORT
Field Controls 2630 Airport Road Kinston, NC 28504
252 522-3031
Fax: 1 800-367-7942
Visit us at: www.fieldcontrols.com
Documents / Resources
![]() |
FIELDCONTROLS FCPV Fresh Command Ventilation System [pdf] Owner's Manual FCPV, FCPV Fresh Command Ventilation System, Fresh Command Ventilation System, Command Ventilation System, Ventilation System, System |