FESTO P2 Guide Unit Eagf Instruction Manual

FESTO-Logo

FESTO P2 Guide Unit Eagf

FESTO-P2-Guide-Unit-Eagf-Product

Product Information

Specifications:

  • Product: Guide unit EAGF
  • Segmentation: Guide unit, for electric cylinder
  • Series: EAGF
  • Size Options: 16mm, 25mm, 32mm, 40mm, 45mm, 50mm, 60mm, 63mm, 80mm, 100mm
  • Stroke Options: 50mm, 100mm, 150mm, 200mm, 300mm, 320mm, 400mm

Product Usage Instructions

Installation:

  1. Ensure the guide unit is compatible with your electric cylinder.
  2. Select the appropriate size based on your application requirements.
  3. Mount the guide unit securely in the desired position.

Maintenance:
Regularly inspect the guide unit for any signs of wear or damage. Clean and lubricate the guide components as needed to ensure smooth operation.

Load Capacity:
Refer to the characteristic load values provided in the datasheet to ensure the guide unit can handle the required forces and torques in your application.

FAQ:

  • What materials are used in the construction of the Guide unit EAGF?
    The Guide unit EAGF is constructed with wrought aluminum alloy for the yoke plate and housing, tempered steel for the guide component, and is RoHS-compliant.
  • How can I calculate the load comparison factor for the Guide unit EAGF?
    To calculate the load comparison factor, follow the equation provided in the manual when subjecting the guide unit to multiple forces and torques simultaneously.

Characteristics

At a glance

  • The guide unit EAGF provides anti-twist protection for electric cylinders in the case of high-torque loads
  • It offers a high level of guide precision for workpiece handling and other applications
  • The interface enables simple and fast mounting on many Festo drives/axes

Product segmentation

FESTO-P2-Guide-Unit-Eagf-Fig- (49)

Festo Core Range
Solves the majority of your automation tasks With the Festo Core Range, we have selected the most important products and functions from our broad product catalog and added the quickest delivery. the Core Range offers you the best value with the expected high Festo quality.

  • Quickest delivery, worldwide – wherever, whenever
  • Expected high Festo quality
  • Easy and fast to select

Diagrams

FESTO-P2-Guide-Unit-Eagf-Fig- (1)

Further information → eagf

Allocation

Allocation        
[P2] Version P2 (EPCC)   [V2] Version V2 (ESBF)
FESTO-P2-Guide-Unit-Eagf-Fig- (2) FESTO-P2-Guide-Unit-Eagf-Fig- (3)

Type code

001 Series
EAGF Guide unit, for electric cylinder  
002 Allocation
P2 Version P2 (EPCC)  
V2 Version V2 (ESBF)  
003 Guide
KF Recirculating ball bearing guide  
004 Size [mm]
16 16  
25 25  
32 32  
40 40  
45 45  
50 50  
60 60  
63 63  
80 80  
100 100  
005 Stroke [mm]
50 50  
100 100  
150 150  
200 200  
300 300  
320 320  
400 400  

Datasheet

Guide unit EAGF, for electric cylinder EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (4)

General technical data for EAGF-P2-KF with EPCC

Size 32 45 60
Stroke 1 … 200 mm 1 … 300 mm 1 … 500 mm
Design Guidance
Guide Recirculating ball bearing guide
Displacement force 1.6 N 2 N 3 N
Max. speed 1 m/s
Max. acceleration 25 m/s2
Reversing backlash theoretical 0 µm
Type of mounting Via female thread
Mounting position optional

Operating and environmental conditions for EAGF-P2-KF with EPCC

Size 32 45 60
Ambient temperature 0 … 60°C
Degree of protection IP40
Corrosion resistance class

CRC 1)

0 – No corrosion stress
  1. More information: www.festo.com/x/topic/crc.

Weights for EAGF-P2-KF with EPCC

Size 32 45 60
Basic weight for 0 mm stroke 613 g 1,037 g 1,614 g
Additional weight per 10 mm

stroke

7.9 g 12.3 g 17.8 g
Moving mass for 0 mm stroke 170 g 342 g 583 g
Additional moving mass per

10 mm stroke

7.9 g 12.3 g 17.8 g

Centre of gravity of the moving mass for EAGF-P2-KF with EPCC

Size 32 45 60
Centre of gravity at 0 mm

stroke

26 mm 25 mm 31 mm
Centre of gravity addition of

moving mass per 10 mm

4.3 mm

Materials for EAGF-P2-KF with EPCC

Material yoke plate Wrought aluminum alloy, Anodised
Material housing Wrought aluminum alloy, Anodised
Material guide component Tempered steel, Hard-chrome-plated
Note on materials RoHS-compliant
LABS (PWIS) conformity VDMA24364 zone III

Characteristic load values for EAGF-P2-KF with EPCC

  • The indicated forces and torques refer to the guide center.
  • Calculation example: see separate documentFESTO-P2-Guide-Unit-Eagf-Fig- (5)

Characteristic load values for EAGF-P2-KF with EPCC, static
The indicated forces and moments refer to the guide centre.

Size 32 45 60
Max. force Fy static 355 N 415 N 510 N
Max. force Fz static 355 N 415 N 510 N
Max. torque Mx static 13 Nm 19 Nm 27 Nm
Max. torque My static 9 Nm 12 Nm 20 Nm
Max. torque Mz static 9 Nm 12 Nm 20 Nm

Characteristic load values for EAGF-P2-KF with EPCC; dynamic at a service life of 5000 km
The indicated forces and moments refer to the guide center.

Size 32 45 60
Max. force Fy 160 N 320 N 380 N
Max. force Fz 160 N 320 N 380 N
Max. moment Mx 6 Nm 15 Nm 20 Nm
Max. moment My 4 Nm 10 Nm 15 Nm
Max. moment Mz 4 Nm 10 Nm 15 Nm

Distance X

  • Size: 32/45/60
  • Distance X: 54 mm/63 mm/76 mm

FESTO-P2-Guide-Unit-Eagf-Fig- (6)

Calculating the load comparison factor for EAGF-P2-KF with EPCC
If the guide unit is subjected to two or more of the indicated forces and torques at the same time, the following equation must be satisfied in addition to the indicated maximum loads.

  • F1 / M1 = dynamic value
  • F2 / M2 = maximum value

FESTO-P2-Guide-Unit-Eagf-Fig- (7)

Calculation of the service life for EAGF-P2-KF with EPCC

  • The service life of the guide depends on the load. To be able to make an approximate statement about the service life of the guide, the graph below shows the load comparison factor fv in relation to the service life ratio q.
  • These values are only theoretical. You must consult your local contact person at Festo for load comparison factors fv greater than 1.5.
  • Example: The effect on the service life, deviating from the specified reference service life, can be determined using the service life ratio q:
  • Assuming: Reference service life = 5000 km
  • Required service life = 3000 km
  • q = 3000 km/5000 km = 0.6
  • The graph gives a load comparison factor fv of 1.2. This means that the permissible total load can be utilized up to 120%.
  • fv > 1.5 are only theoretical comparison values.FESTO-P2-Guide-Unit-Eagf-Fig- (8)

Max. payload F and torque M as a function of projection A for EAGF-P2-KF with EPCC

  • A = projection
  • X = distance to center of gravity of the payload
  • S = center of gravity of the payload
  • M = torqueFESTO-P2-Guide-Unit-Eagf-Fig- (9)

Explanation of how to read the graphs in the case of a combined load

  • Determine projection (50 mm)
  • Enter transverse force (50 N)
  • Enter the distance from the curve
  • Permitted torque is the difference between M2 and M1FESTO-P2-Guide-Unit-Eagf-Fig- (10)

Payload F and torque M as a function of projection A for EAGF-P2-KF-32 with EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (11)

Payload F and torque M as a function of projection A for EAGF-P2-KF-45 with EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (12)

Payload F and torque M as a function of projection A for EAGF-P2-KF-60 with EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (13)

Deflection f (due to own weight) as a function of projection A for EAGF-P2-KF with EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (14)

Deflection f (due to own weight) as a function of projection A for EAGF-P2-KF with EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (15)

Deflection f (due to transverse force) as a function of projection A for EAGF-P2-KF with EPCC

The max. permissible transverse force must not be exceeded.

  • f1 = (F1 / F2) * f2
  • F2 = 10 N
  • A = projection of guide rod
  • f1 = deflection due to transverse force
  • F1 = transverse force
  • F2 = standardised transverse force
  • f2 = deflection due to standardised transverse force (value from graph)

FESTO-P2-Guide-Unit-Eagf-Fig- (16)

Deflection f (due to transverse force) as a function of projection A for EAGF-P2-KF with EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (17)

Incline a (due to torque) as a function of projection A for EAGF-P2-KF with EPCC

  • a1 = (M1 / M2) * a2
  • M2 = 2 Nm
  • (valid for a ≤ 10°)
  • A = projection of guide rod
  • a1 = incline due to torque
  • M1 = torque
  • M2 = standardized torque
  • a2 = deflection due to standardized transverse force (value from graph)

FESTO-P2-Guide-Unit-Eagf-Fig- (18)

Incline a (due to torque) as a function of projection A for EAGF-P2-KF with EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (19)

Option to combine EAGF-P2 with EAGF-P2 by direct mounting

  • Base axis EAGF-P2-KF-45 with assembly axis EAGF-P2-KF-32
  • Base axis EAGF-P2-KF-60 with assembly axis EAGF-P2-KF-45FESTO-P2-Guide-Unit-Eagf-Fig- (20)

Option to combine EAGF-P2 with EGSC/EGSS using an adapter kit

  • Base axis EAGF-P2-KF-32 with assembly axis EGSC/EGSS-25
  • Base axis EAGF-P2-KF-45 with assembly axis EGSC/EGSS-32
  • Base axis EAGF-P2-KF-60 with assembly axis EGSC/EGSS-45FESTO-P2-Guide-Unit-Eagf-Fig- (21)

Option to combine ELGC/ELGS with EAGF-P2 by direct mounting

  • Base axis ELGC/ELGS-45 with assembly axis EAGF-P2-KF-32
  • Base axis ELGC/ELGS-60 with assembly axis EAGF-P2-KF-45
  • Base axis ELGC/ELGS-80 with assembly axis EAGF-P2-KF-60FESTO-P2-Guide-Unit-Eagf-Fig- (22)

Option to combine EAGF-P2 with ERMO/ERMS by direct mounting

  • Base axis EAGF-P2-KF-32 with assembly axis ERMO/ERMS-12
  • Base axis EAGF-P2-KF-45 with assembly axis ERMO/ERMS-16
  • Base axis EAGF-P2-KF-60 with assembly axis ERMO/ERMS-25FESTO-P2-Guide-Unit-Eagf-Fig- (23)

Guide unit EAGF, for electric cylinder ESBFFESTO-P2-Guide-Unit-Eagf-Fig- (24)

General technical data for EAGF-V2-KF with ESBF

Size 32 40 50 63 80 100
Stroke 1 … 500 mm 1 … 550 mm
Design Guidance
Guide Recirculating ball bearing guide
Displacement force 15 N 40 N
Reversing backlash theoretical 0 µm
Type of mounting Via female thread
Mounting position optional

Operating and environmental conditions for EAGF-V2-KF with ESBF

Operating and environmental conditions for EAGF-V2-KF with ESBF
Size 32 40 50 63 80 100
Ambient temperature -20 … 80°C
Corrosion resistance class

CRC 1)

0 – No corrosion stress
  1. More information: www.festo.com/x/topic/crc.

Weights for EAGF-V2-KF with ESBF

Weights for EAGF-V2-KF with ESBF
Size 32 40 50 63 80 100
Basic weight for 0 mm stroke 1,685 g 2,517 g 4,059 g 5,525 g 10,517 g 13,263 g
Additional weight per 10 mm

stroke

18 g 32 g 49 g 76 g
Moving mass for 0 mm stroke 724 g 1,283 g 2,015 g 2,560 g 5,166 g 6,148 g
Additional moving mass per

10 mm stroke

18 g 32 g 49 g 76 g

Centre of gravity of the moving mass for EAGF-V2-KF with ESBF

Centre of gravity of the moving mass for EAGF-V2-KF with ESBF
Size 32 40 50 63 80 100
Centre of gravity at 0 mm

stroke

30 mm 38 mm 46 mm 48 mm 54 mm 47 mm
Centre of gravity addition of

moving mass per 10 mm

4.1 mm 4.2 mm 4.3 mm 4.1 mm 3.8 mm 3.6 mm

Materials for EAGF-V2-KF with ESBF

Materials for EAGF-V2-KF with ESBF
Material yoke plate Steel
Material housing Wrought aluminum alloy, Anodised
Material guide component Tempered steel
Note on materials RoHS-compliant
LABS (PWIS) conformity VDMA24364-B2-L

Characteristic load values for EAGF-V2-KF with ESBF

  • The indicated forces and torques refer to the guide center.
  • Calculation example: see separate document

FESTO-P2-Guide-Unit-Eagf-Fig- (25)

Characteristic load values for EAGF-V2-KF with ESBF, static
The indicated forces and moments refer to the guide center.

Size 32 40 50 63 80 100
Max. force Fy static 1,020 N 1,260 N 1,600 N 3,120 N
Max. force Fz static 1,020 N 1,260 N 1,600 N 3,120 N
Max. torque Mx static 38 Nm 55 Nm 83 Nm 95 Nm 231 Nm 268 Nm
Max. torque My static 46 Nm 65 Nm 89 Nm 115 Nm 259 Nm 267 Nm
Max. torque Mz static 46 Nm 65 Nm 89 Nm 115 Nm 259 Nm 267 Nm

Characteristic load values for EAGF-V2-KF with ESBF, dynamic at a service life of 5000 km
The indicated forces and moments refer to the guide center.

Size 32 40 50 63 80 100
Max. force Fy 750 N 1,000 N 1,260 N 2,300 N
Max. force Fz 750 N 1,000 N 1,260 N 2,300 N
Max. moment Mx 28 Nm 44 Nm 65 Nm 75 Nm 170 Nm 198 Nm
Max. moment My 34 Nm 52 Nm 70 Nm 90 Nm 191 Nm 197 Nm
Max. moment Mz 34 Nm 52 Nm 70 Nm 90 Nm 191 Nm 197 Nm

Distance X

  • Size: 32/40/50/63/80/100
  • Distance X: 83 mm/85 mm/99 mm/117 mm/142 mm/145 mm

FESTO-P2-Guide-Unit-Eagf-Fig- (26)

Calculating the load comparison factor for EAGF-V2-KF with ESBF
If the guide unit is subjected to two or more of the indicated forces and torques at the same time, the following equation must be satisfied in addition to the indicated maximum loads.

  • F1 / M1 = dynamic value
  • F2 / M2 = maximum value

FESTO-P2-Guide-Unit-Eagf-Fig- (27)

Calculation of the service life for EAGF-V2-KF with ESBF

  • The service life of the guide depends on the load. To be able to make an approximate statement about the service life of the guide, the graph below shows the load comparison factor fv with the service life ratio q.
  • These values are only theoretical. You must consult your local contact person at Festo for load comparison factors fv greater than 1.5.
  • Example: The effect on the service life, deviating from the specified reference service life, can be determined using the service life ratio q:
  • Assuming: Reference service life = 5000 km
  • Required service life = 3000 km
  • q = 3000 km/5000 km = 0.6
  • The graph gives a load comparison factor fv of 1.2. This means that the permissible total load can be utilized up to 120%.
  • fv > 1.5 are only theoretical comparison values.

FESTO-P2-Guide-Unit-Eagf-Fig- (28)

Max. payload F and torque M as a function of projection A for EAGF-V2-KF with ESBF

  • A = projection
  • X = distance to center of gravity of the payload
  • S = center of gravity of the payload
  • M = torque

FESTO-P2-Guide-Unit-Eagf-Fig- (29)

Explanation of how to read the graphs in the case of a combined load

  • Determine projection (50 mm)
  • Enter transverse force (50 N)
  • Enter the distance from the curve
  • Permitted torque is the difference between M2 and M1

FESTO-P2-Guide-Unit-Eagf-Fig- (30)

Payload F and torque M as a function of projection A for EAGF-V2-KF-32 with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (31)

Payload F and torque M as a function of projection A for EAGF-V2-KF-40 with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (32)

Payload F and torque M as a function of projection A for EAGF-V2-KF-50 with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (33)

Payload F and torque M as a function of projection A for EAGF-V2-KF-63 with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (34)

Payload F and torque M as a function of projection A for EAGF-V2-KF-80 with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (35)

Payload F and torque M as a function of projection A for EAGF-V2-KF-100 with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (36)

Deflection f (due to own weight) as a function of projection A for EAGF-V2-KF with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (37)

Deflection f (due to own weight) as a function of projection A for EAGF-V2-KF with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (38)

Deflection f (due to transverse force) as a function of projection A for EAGF-V2-KF with ESBF

  • The max. permissible transverse force must not be exceeded.
  • f1 = (F1 / F2) * f2
  • F2 = 10 N
  • A = projection of guide rod
  • f1 = deflection due to transverse force
  • F1 = transverse force
  • F2 = standardized transverse force
  • f2 = deflection due to standardized transverse force (value from graph)

FESTO-P2-Guide-Unit-Eagf-Fig- (39)

Deflection f (due to transverse force) as a function of projection A for EAGF-V2-KF with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (40)

Incline a (due to torque) as a function of projection A for EAGF-V2-KF with ESBF

  • a1 = (M1 / M2) * a2
  • M2 = 2 Nm
  • (valid for a ≤ 10°)
  • A = projection of guide rod
  • a1 = incline due to torque
  • M1 = torque
  • M2 = standardised torque
  • a2 = deflection due to standardised transverse force (value from graph)FESTO-P2-Guide-Unit-Eagf-Fig- (41)

Incline a (due to torque) as a function of projection A for EAGF-V2-KF with ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (42)

Dimensions

Dimensions – Guide units EAGF, for electric cylinders EPCC

FESTO-P2-Guide-Unit-Eagf-Fig- (43) FESTO-P2-Guide-Unit-Eagf-Fig- (44)

  B1 B2 B3 B4

 

±0,1

B5

 

±0,05

B6

 

±0,1

B7 B8 B9 B10

 

±0,05

D1

⌀

D2

⌀ H8

EAGF-32 100 98 75 50 30 24 42 33 16 50 8 7
EAGF-45 120 118 90 50 33 22,5 58 46 24 58 10 7
EAGF-60 135 133 105 58 40 34 73 61 30 73 12 7
  D3 D4

⌀

D5

⌀

D6

⌀ H8

D7 D8

⌀

D9

⌀

D10

⌀ H8

D11

⌀

D12

⌀ H8

D13

⌀

D14
EAGF-32 M5 8 4,5 7 M5 8 4,5 7 8 7 5 M3
EAGF-45 M5 10 5,5 7 M5 10 5,5 7 10 7 5,5 M3
EAGF-60 M5 11 6,6 7 M5 10 5,5 7 10 7 5,5 M4
  H1 H2 H3 H4

 

±0,1

H5

 

±0,05

H6

 

±0,05

H7 H8 L1 L2 L3

 

±0,05

L4
EAGF-32 40 28 26 24 16 20 26 4,1 102 75 50 54
EAGF-45 51 37 35 35 20 25 32,5 5,5 116 85 58 63
EAGF-60 60 39 37 42 25 25 40,5 6,9 139 105 73 76
  L5 L6 L7

 

±0,05

L8

 

±0,05

T1

 

+0,1

T2 T3

 

+0,1

T4 T5 T6

 

+0,1

T7 T8

 

+0,1

T9
EAGF-32 34 15 34 20 1,6 8,5 1,6 12 4,4 1,6 4,4 1,6 7
EAGF-45 47 19 47 25 1,6 12 1,6 12 7 1,6 5,7 1,6 7
EAGF-60 63 22 73 25 1,6 10 1,6 10 7 1,6 5,5 1,6 9

Dimensions – Guide units EAGF, for electric cylinders ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (45)

  B1

 

–0,3

B2 B3

 

±0,2

B4

 

±0,2

B5

 

±0,2

D1

@

D2

@

h6

D3

@

D4

@

D5

@

H8

D6 D7
EAGF-32 50 45 32,5 32,5 32,5 44 12 11 6,6 34 M6 M6
EAGF-40 58 54 38 38 38 48 16 11 6,6 39 M8 M6
EAGF-50 70 63 46,5 46,5 46,5 60 20 15 9 45 M8 M8
EAGF-63 85 80 56,5 56,5 56,5 60 20 15 9 52 M16 M8
EAGF-80 105 100 72 72 72 78 25 18 11 60 M18 M10
EAGF-100 130 120 89 89 89 78 25 18 11 70 M18 M10
  D8 H1

 

–0,5

H2 H3

 

±0,2

H4

 

±0,2

H5

 

±0,2

H6 H7

 

±0,2

KK L1

 

±1

L2
EAGF-32 M6 97 90 78 32,5 74 50,5±0,3 61 M10x1,25 154,8 125
EAGF-40 M6 115 110 84 38 87 58,5±0,3 69 M12x1,25 172,8 140
EAGF-50 M8 137 130 100 46,5 104 70,5±0,3 85 M16x1,5 187,8 150
EAGF-63 M8 152 145 105 56,5 119 85,5±0,3 100 M16x1,5 219,8 182
EAGF-80 M10 189 180 130 72 148 106+1/–0,6 130 M20x1,5 257,8 215
EAGF-100 M10 213 200 150 89 172 131+1/–0,6 150 M20x1,5 262,8 220
  L4 L5 L6 L7 L8

 

±0,2

L9

 

±0,2

L11 L12 T1 T2 ß1
EAGF-32 24 76 12 4,3 32,5 78 24 12 14 6,5 15
EAGF-40 28 81 15 11 38 84 27 – 14 6,5 15
EAGF-50 34 79 15 18,8 46,5 100 30 37 16 9 19
EAGF-63 34 111 15 15,3 56,5 105 30 – 16 9 19
EAGF-80 40 128 20 21 72 – 39 – 20 11 27
EAGF-100 40 128 20 24,5 89 – 39 – 20 11 27

Dimensions – Screw-in depth of the piston rod for the electric cylinder ESBF

FESTO-P2-Guide-Unit-Eagf-Fig- (46)

  1. EAGF-…
  2. ESBF-…
  3. The dimensions L3 and L10 are only valid in combination with screw-in depth L13.
  L3 L10 L13

 

±0,2

EAGF-32 70,2±1 9,2±1,5 15
EAGF-40 79,3±1 5,3±1,5 16
EAGF-50 96,1±0.9 10,1±1,5 24
EAGF-63 96,3±1 10,3±1,6 24
EAGF-80 121,1±1,1 14,1±1,8 30
EAGF-100 126,1±1,1 14,1±1,8 30

Ordering Data

Guide units EAGF, for electric cylinder EPCO
  Size Stroke Part no. Type
FESTO-P2-Guide-Unit-Eagf-Fig- (47)  32 1 … 200 mm 8158030 EAGF-P2-KF-32-
50 mm 8158032 EAGF-P2-KF-32-50
100 mm 8158029 EAGF-P2-KF-32-100
150 mm 8158027 EAGF-P2-KF-32-150
200 mm 8158028 EAGF-P2-KF-32-200
45 1 … 300 mm 8158133 EAGF-P2-KF-45-
50 mm 8158131 EAGF-P2-KF-45-50
100 mm 8158123 EAGF-P2-KF-45-100
150 mm 8158125 EAGF-P2-KF-45-150
200 mm 8158127 EAGF-P2-KF-45-200
300 mm 8158130 EAGF-P2-KF-45-300
60 1 … 500 mm 8158150 EAGF-P2-KF-60-
100 mm 8158138 EAGF-P2-KF-60-100
150 mm 8158140 EAGF-P2-KF-60-150
200 mm 8158142 EAGF-P2-KF-60-200
300 mm 8158031 EAGF-P2-KF-60-300
Guide units EAGF, for electric cylinder ESBF
  Size Stroke Part no. Type
FESTO-P2-Guide-Unit-Eagf-Fig- (48) 32 1 … 500 mm 3038083 EAGF-V2-KF-32-
100 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2782679 EAGF-V2-KF-32-100
200 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2782818 EAGF-V2-KF-32-200
320 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2782885 EAGF-V2-KF-32-320
400 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2782923 EAGF-V2-KF-32-400
40 1 … 500 mm 3038089 EAGF-V2-KF-40-
100 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2782939 EAGF-V2-KF-40-100
200 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2782976 EAGF-V2-KF-40-200
320 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2783047 EAGF-V2-KF-40-320
400 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2783080 EAGF-V2-KF-40-400
50 1 … 500 mm 3038094 EAGF-V2-KF-50-
100 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2783639 EAGF-V2-KF-50-100
200 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2784152 EAGF-V2-KF-50-200
320 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2784164 EAGF-V2-KF-50-320
400 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)2784184 EAGF-V2-KF-50-400
63 1 … 500 mm 2608521 EAGF-V2-KF-63-
100 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)1725842 EAGF-V2-KF-63-100
200 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)1725843 EAGF-V2-KF-63-200
320 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)1725844 EAGF-V2-KF-63-320
400 mm FESTO-P2-Guide-Unit-Eagf-Fig- (49)1725845 EAGF-V2-KF-63-400
80 1 … 550 mm 2608528 EAGF-V2-KF-80-
100 mm 1725846 EAGF-V2-KF-80-100
200 mm 1725847 EAGF-V2-KF-80-200
320 mm 1725848 EAGF-V2-KF-80-320
400 mm 1725849 EAGF-V2-KF-80-400
100 1 … 550 mm 2608532 EAGF-V2-KF-100-
100 mm 1725850 EAGF-V2-KF-100-100
200 mm 1725851 EAGF-V2-KF-100-200
320 mm 1725852 EAGF-V2-KF-100-320
400 mm 1725853 EAGF-V2-KF-100-400

Accessories

Centring pin ZBS-4 for guide unit with electric cylinder EPCC
  Description Material sleeve Size of pack Product weight Part no. Type
FESTO-P2-Guide-Unit-Eagf-Fig- (50) For size 32 High-alloy stainless steel 10 0.5 g 562959 ZBS-4
Centering sleeve ZBH-5 for guide unit with electric cylinder EPCC
  Description Material sleeve Size of pack Product weight Part no. Type
FESTO-P2-Guide-Unit-Eagf-Fig- (51) For size 45 Steel 10 1 g 8146543 ZBH-5-B
Centering sleeve ZBH-7 for guide unit with electric cylinder EPCC
  Description Material sleeve Size of pack Product weight Part no. Type
FESTO-P2-Guide-Unit-Eagf-Fig- (52) For sizes 32, 45,

60

Steel 10 1 g 8146544 ZBH-7-B
Adapter kit EHAA for guide unit with electric cylinder EPCC (for mounting the mini slide EGSC, EGSS on the yoke plate)FESTO-P2-Guide-Unit-Eagf-Fig- (53)
Description Product weight Part no. Type
For size 32 56 g 8158473 EHAA-D-L2-32-L2-25
For size 45 60 g 8066713 EHAA-D-L2-32-L2-32
For size 60 136 g 8066714 EHAA-D-L2-45-L2-45

www.festo.com/catalogue/.

Documents / Resources

PDF thumbnailP2 Guide Unit Eagf
Instruction Manual · P2 Guide Unit Eagf, Guide Unit Eagf, Unit Eagf, Eagf

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.