FENIX Ecosun Basic Radiant Panels

Specifications
- Model: ECOSUN Basic
- Power Output: 300W, 600W, 850W
Product Usage Instructions
Installation:
Before starting the installation process, make sure you have the necessary measurements for your specific model:
- Ecosun 300 Basic: X(mm) 592, Y(mm) 592, A(mm) 340, B(mm) 355
- Ecosun 600 Basic: X(mm) 1192, Y(mm) 592, A(mm) 940, B(mm) 355
- Ecosun 850 Basic: X(mm) 1192, Y(mm) 800, A(mm) 940, B(mm) 355
Ensure the thickness of the panel is 30mm and follow the height and distance guidelines based on the power output and room size.
Important Warnings:
Follow these important warnings to ensure safe usage of the product:
- Use a residual current device with a release current of In=30mA.
- Avoid pollution of the radiant front surface of the panel.
- Consult a specialized firm for anchoring advice, especially for specific wall structures.
- Children must not play with the appliance and must be supervised around it at all times.
- Avoid covering the heater to prevent overheating.
Function of the Control Unit:
The control unit is essential for complying with mandatory ecodesign requirements. Refer to the code TW for specific control functions and heat output details.
Important Warnings
- WARNING: In order to avoid overheating, do not cover the heater.
- Installation, electrical connection, and the first commissioning are permitted to be performed by a worker with relevant qualifications.
- The temperature ofthe environment (surrounding air) where the radiant panel is situated must not exceed 40°C!
- The electrical installation must allow the disconnection of all working wires supplying the heating panel. Always use a residual current device with the release current IΔn=30mA.
- The damaged lead-in cable of the appliance shall only be replaced by the manufacturer or a service technician.
- The product type number means the input of the product (ECOSUN 600 Basic = 600W ).
- We recommend using gloves when manipulating the panel to prevent any pollution of the radiant front surface of the panel.
- Clean the panel with water and detergent, using a fine brush.
- The panel should not be arranged right under a fixed connection socket.
- Be careful to choose the right type of anchoring element (wall plug), particularly when dealing with plasterboard/gypsum fibreboard and porous concrete structures. If necessary, consult a specialised firm or manufacturer about anchoring – for example, http://www.fischer.co.uk/Home.aspx.
- It is forbidden to use wall anchors with a self-tapping thread to attach panels to plasterboard/gypsum fibreboard ceilings, see Fig. 2. Examples of suitable types of wall anchors can be seen in Fig. 3.
- This heater isn´t fitted with a room temperature control device. Do not use this heater in small rooms if they are occupied by people who cannot be left in the room by themselves unless permanent supervision is provided.
- This appliance can be used by children from the age of 8 and older, and persons with lower physical, sensory o, or mental abilities o, or a lack of experience or knowledge pr, provided they are under supervision or have been trained in the use of the appliance in a safe manner and understand the possible danger. Children may not play with the appliance. Cleaning and maintenance by the user must not be carried out by children without supervision.
- Children under 3 years of age should be prevented from accessing the appliance, unless they are constantly supervised. Children from 3 to 8 years of age may switch the appliance on/off only if it is placed or installed in its intended standard operating position, and if they are under supervision or have been instructed in the safe use of the appliance, and if they understand the possible danger. Children from 3 to 8 years of age mustn´t insert the plug into the socket, control or clean the appliance o, or carry out maintenance that is to be done by the user.
WARNING: Some parts of this product may become very hot and cause burns. Special attention must be paid to this fact in the presence of children and handicapped persons.

WARNING: To prevent overheating, do not cover the heater

Use
- Flats, offices, schools, hospitals, shops, industry, and agricultural premises, etc.
- The panels can be installed on flammable materials.
Wiring
- Power supply: 230V/50Hz
- Protection class I
- IP 44
- The panel is fitted with a thermal fuse.
This product is an electric fixed local space heater and, to comply with the mandatory ecodesign requirements laid down in Commission Regulation (EU) 2024/1103, it must be equipped with a control unit that provides at least the following control functions:
- TW (0/f2/0/0/0/0/0/0)
- TW (0/0/f3/0/0/0/0/0)
- TW (0/0/0/f4/0/0/0/0)
- TW (0/0/0/0/0/0/0/f8)
Function of the control unit according to the code TW (0/0/0/0/0/0/0/f8)
| This product needs a control to comply with the mandatory ecodesign requirements set out in Regulation (EU) 2024/1103 | |||||
| Contact details | FENIX s.r.o., Jaroslava Ježka 1338/18a, 790 01 Jeseník, Czech Republic | ||||
| Model identifier(s): | ECOSUN Basic | ||||
| Item | Symbol | Value | Unit | Item | Unit |
| Control functions necessary to comply with the mandatory ecodesign requirements set out in Regulation (EU) 2024/1103. | |||||
| Heat output | Type of heat output/room temperature control (select one) | ||||
| Nominal heat output
Minimum heat output (indicative) Maximum continuous heat output |
Pnom
Pmin Pmax,c |
0,3 – 0,85 | kW
kW kW |
Single-stage heat output and no room temperature control
Two or more manual stages, no room temperature control, a mechanical thermostat, and room temperature control |
No
No No |
| N/A | |||||
| 0,3 – 0,85 | |||||
| Electronic room temperature control | No | ||||
| Electronic room temperature control plus a day timer | No | ||||
| Electronic room temperature control plus a week timer | Yes | ||||
| Other control options (multiple selections possible) | |||||
| Presence detection | No | ||||
| Open window detection | No | ||||
| Distance control option | No | ||||
| Adaptive start control | No | ||||
| Working time limitation | No | ||||
| Black bulb sensor | No | ||||
| Self-learning functionality | No | ||||
| Control accuracy | Yes | ||||
| Code of temperature control (CT) | Control functions | |||||||||
| f1 | f2 | f3 | f4 | f5 | f6 | f7 | f8 | |||
| Type of temperature control | Single stage, no temperature control | NC | ||||||||
| Two or more manual stages, no temperature control | TX | |||||||||
| Mechanical thermostat room temperature control | TM | |||||||||
| Electronic room temperature control | TE | |||||||||
| Electronic room temperature control plus daytime | TD | |||||||||
| Electronic room temperature control plus a week timer | TW | |||||||||
| Control functions | Presence detection | 1 | ||||||||
| Open window detection | 2 | |||||||||
| Distance control option | 3 | |||||||||
| Adaptive start control | 4 | |||||||||
| Working time limitation | 5 | |||||||||
| Black bulb sensor | 6 | |||||||||
| Self-learning functionality | 7 | |||||||||
| Control accuracy with CA < 2 Kelvin and CSD < 2 Kelvin | 8 | |||||||||
Instructions for dismantling, disposal, or recycling of the product at the end of its life:
Products marked with this symbol must not be disposed of with normal household waste, but must be disposed of separately and recycled.- The collection and recycling of products at the end of their life must be ensured in accordance with local rules and regulations.
Installing
- The panels are intended for vertical installation. In case of horizontal installation on the ceiling of a room, hang the panel on a mounting frame, or use chains or cords.
- The minimum distance of the panel front wall and lateral walls from inflammable objects is 10 cm.
- In order to comply with the IP protection, it is necessary that the connection of the supply cord of the panel meets the minimum coverage of the product indicated on the label.
Procedure — vertical mounting:
- Mark the holes according to the table, drill out the holes, insert the dowels, and drive the screw in to protrude approximately. 5 mm.
- Always fix the panel on two upper locks; two lower locks serve to reverse the suspension of the panel.
- Connect the lead-in cable to a fixed power distribution in accordance with the colour marking of wires.
- Put the panel on the two upper locks.
Procedure – horizontal mounting
- Position the mounting frame in the location where the panel is to be placed, using a pen, and mark holes according to the holes on the frame.
- Drill the holes, insert the wall anchors, and attach the mounting frame with the screws.
- Connect the lead-in cable to the mains in accordance with the colour of the conductors.
- Slide the panel into the mounting frame.

| Ecosun | X (mm) | Y (mm) | A (mm) | B (mm) | Thickness |
| 300 Basic | 592 | 592 | 340 | 355 |
30 |
| 600 Basic | 1192 | 592 | 940 | 355 | |
| 850 Basic | 1192 | 800 | 940 | 355 |
| Ecosun | A (mm) | B (mm) |
| 300 Basic | 340 | 280 |
| 600 Basic | 935 | 280 |
| 850 Basic |
MINIMUM DISTANCES

| 300W | h = 2,5m | x = 0,6m |
| 600W | h = 2,5m | x = 0,6m |
| 850W | h ≥ 3m | x ≥1,2m |
- The installation height and distance between panels stated here are recommended; other distances must be discussed with
Clearance distances
The distance between the bottom edge of the appliance and the floor mustn’t be less than 50 mm; 150 mm is recommended. The clearance distance on the side (e.,g. from furniture) must be at least 100 mm, and 100 mm is the minimum in the upward direction (see Fig. ).

Warranty
- This product is covered with a 24-month warranty since the date of purchase, which applies to defects of material and processing. The complete wording of the Warranty Guidelines is available at the supplier’s office or at the website www.fenixgroup.eu. The warranty does not apply to defects caused by unprofessional intervention, negligence, incorrect use, transport,/or inconvenient storage of the panel. The manufacturer is not responsible for any indirect damage caused by the use of this panel.
- Product type:
- Date:
- Stamp, signature:
- Serial number (label on the panel rear side):_ _ _ — _ _ _ — _ _ _ — _ _ _ — _ _ _
Fenix s.r.o.
- Jaroslava Ježka 1338/18a, 790 01 Jeseník
- tel.: +420 584 495 442, fax: +420 584 495 431
- e-mail: fenix@fenixgroup.cz , http://www.fenixgroup.cz
Fenix Trading s.r.o.
- Slezská 2, 790 01 Jeseník
- tel.: +420 584 495 304, fax: +420 584 495 303
- e-mail: fenix@fenixgroup.cz , http://www.fenixgroup.cz
FAQs
Q: Can children operate the appliance?
Documents / Resources
![]() | Ecosun Basic Radiant Panels |
References
- FENIXwww.fenixgroup.cz
- FENIXwww.fenixgroup.eu
- Drží v díÅe jako zvíÅe! - Hmoždinky fischer - fischerwww.fischer-cz.cz
- Home - fischer fixingswww.fischer.co.uk
- Innovative Befestigungstechnik vom Spezialisten | fischerwww.fischer.de
- Ðа главнÑÑwww.fischerfixing.ru
- User Manualmanual.tools