AC2 Array Ceiling Air Purifier
Array AC2
Ceiling Mounted Air Purifier
PLEASE READ THESE INSTRUCTIONS BEFORE USE.
DO NOT DISCARD: KEEP FOR FUTURE REFERENCE.
PACKAGING CONTENTS
- ir Purifier (1X)
- Hybrid Filters w/ Pre-Filter (2X)
- 16ft mounting cables with clutches (2X)
- Thank You Card (1X)
- Quick Start Guide (1X)
- User Manual (1X)
TOOLS REQUIRED FOR INSTALLATION
- Gloves
- Ladder/Step Stool
- Wire Nuts
- Level
NOTE: Three people are recommended for easy and proper installation
NOTE: This product was designed for use in an open ceiling
NOTE: Installation location and hardware must be capable of supporting 501bs per anchor.
If unsure, check with a qualified structural engineer. - Open ceiling at least 10ft tall
- Mounting hooks or location installed to local code and capable of holding the weight of the system
INSTALLATION INSTRUCTIONS
![]() |
||
| Before beginning installation, ensure that a qualified electrician has run a 120V circuit to the installation area. Take out the mounting hardware box and verify induded part quantity. Fellowes strongly recommends a 4in, metallic, octagonal elecirical box because it works best with the provided cover and strain relief. |
Remove unit from packaging and stage on temporary support frays on a tabletop or other surface under or near installation area. |
Open unit door by peeling back the tape as needed and gently pulling outward on the bottom of the door panel. |
Disengage each filter clamp lever until a click is heard.
NOTE: Locking/ unlocking motions are in opposite directions between left and right filter changing mechanisms.
![]() |
||
| Pull each filter out by the strap and set aside for now. | Close door until a lick is heard. | Depending on type of ceiling, attach proper mounting hardware above installation area at proper distances per local regulations for supporting a 45lb (21kg) fixture. |
![]() |
||
| Loop open end of cables through intended fruss. Use provided cable clutch hardware to secure each cable. |
Secure the hooks from the provided aircraft cabling to the housing through the mounting holes. |
Have two people slowly lifting the machine while the other pulls the free end of the cables to keep them taut. Alternate slowly raising each side to keep the unit relatively level during lifting. |
![]() |
||
| Raise the fixture fo at least 8 feet off the ground. For optimum performance, keep at least 12″ of clearance between the top of the unit and the ceiling. Use a level to ensure the product hangs evenly. |
Coil and wrap remaining cable out of the way. Do not rim excess cable lengths. Remove the support trays from the bottom of the unit and dispose of them. |
Ensure power switch located on the power supply is i the off position and the power to the breaker for the area is also off hefore proceeding with connecting. To complete installation, install filters per filter instructions |

![]() |
||
| Thread bale through strain relief bushing. | Thread cable through strain relief base. | Gently twist strain relief components together – strain relief should still be able to move up and down the cable. |
![]() |
||
| Threod cable through plate. | Tighten strain relief nut to the plate with pliers. | |
![]() |
||
| Determine required length of cable and cut allowing 3° that will sick into the electrical box. Tighten strain relief head to secure cord within assembly. |
Connect line, neutral and ground per local regulations. |
|
![]() |
|
| Fasten electrical hox cover to electrical hox. | Flip power switch to the ON (‘T”) position. To complete installation, install filters per instructions helow. |
FILTER INSTALLATION PROCEDURE
![]() |
||
| Open the door by gently pulling outward on the hottom of the door panel. | Remove new filters from protective hags and properly dispose of bags. One at a time, holding each filter by the sirap, dlign support cleat with slot. |
Gently push in filter unfil a dick is heard. NOTE: if top and bottom supports are not properly aligned, the filter will not sit properly and can damage the unit. |
![]() |
||
| Secure filter info place by moving filter clamp lever back into the locked position until a dlick is heard. Repeat steps for second filter. NOTE: Locking/unlocking motions are in opposite directions between left and right filter changing mechanisms. |
Press the power button to turn the unit on. | Close the door until a dlick is heard. |

CUSTOMER SERVICE & SUPPORT
www.fellowes.com
U.S.: 1-800-955-0959
Canada: 1-800-665-4339
Mexico: 001-800-514-9057
1789 Norwood Avenue, lfasca, lllinois 60143 * 1-800-955-0959
wwwifellowes.com
©2023 Fellowes, Inc. Part #412785
Documents / Resources
![]() | AC2 Array Ceiling Air Purifier |
![]() | AC2 Array Ceiling |
References
- arrayviewpoint.fellowes.comarrayviewpoint.fellowes.com
- fellowes.comfellowes.com
- English (United States) - Fellowes®fellowes.com
- English (United States) - Fellowes®support.fellowes.com
- English (United States) - Fellowes®www.fellowes.com
- User Manualmanual.tools
Published: March 9, 2024