محصولات اندرسون پاور 5915-BK

دفترچه راهنمای کنتاکت پاورپل اندرسون پاور پروداکتس مدل ۵۹۱۵-BK

مدل: 5915-BK

1. مقدمه

This manual provides essential instructions for the proper use, installation, and maintenance of Anderson Power Products 5915-BK PowerPole contacts. These contacts are designed for reliable electrical connections in various applications, supporting 10 or 12 AWG wire and rated for up to 75 ampارس

Please read this manual thoroughly before proceeding with installation or use to ensure safety and optimal performance.

2. محصول تمام شدview

The Anderson Power Products 5915-BK is a non-insulated copper contact specifically engineered for use with Anderson PowerPole connectors. Key features include:

  • سازگاری گیج سیم: Designed for 10 AWG (American Wire Gauge) and 12 AWG wires.
  • رتبه فعلی: Capable of handling up to 75 Ampارس
  • مواد: Constructed from high-conductivity copper for efficient power transfer.
  • نوع اتصال: Crimp terminal for secure and durable wire attachment.
  • کاربرد: Integral component for creating custom PowerPole cable assemblies.
Anderson Power Products 5915-BK PowerPole Contact

Figure 1: Anderson Power Products 5915-BK PowerPole Contact. This image shows a single copper contact, designed for crimping onto 10 or 12 AWG wire. The contact features a flat, spade-like end for insertion into a PowerPole housing and a cylindrical barrel for wire crimping.

3. اطلاعات ایمنی

Always observe the following safety precautions when working with electrical components:

  • قطع برق: Ensure all power sources are disconnected before installing or servicing electrical connections.
  • ابزار مناسب: Use appropriate crimping tools designed for the specified wire gauge and contact type to ensure a secure connection.
  • سنج سنج: Match the wire gauge to the contact's specifications (10-12 AWG) to prevent overheating or poor connections.
  • عایق بندی: Although these contacts are non-insulated, ensure proper insulation is applied to exposed wires and connections after assembly, typically by using PowerPole housings.
  • نصب حرفه ای: If you are unsure about any aspect of the installation, consult a qualified electrician.

4. راه اندازی و نصب

Follow these steps to properly install the 5915-BK PowerPole contact onto your wire:

  1. آماده سازی سیم: Strip approximately 1/4 to 3/8 inch (6-9 mm) of insulation from the end of your 10 or 12 AWG wire. Ensure the wire strands are clean and untwisted.
  2. سیم را وارد کنید: Insert the stripped end of the wire fully into the barrel of the 5915-BK contact. The wire strands should be visible through the inspection hole (if present) or reach the end of the barrel.
  3. Crimp Contact: Using a suitable crimping tool for PowerPole contacts, crimp the contact barrel securely onto the wire. Ensure a firm, permanent connection. A good crimp will be mechanically strong and electrically sound.
  4. بازرسی چین و چروک: Visually inspect the crimp for any loose strands or improper deformation. Gently tug on the wire to confirm it is securely held by the contact.
  5. Assemble into Housing (Optional): If using with PowerPole housings (sold separately), insert the crimped contact into the appropriate housing cavity until it clicks into place. Ensure correct polarity.

For optimal performance, always use a dedicated PowerPole crimping tool.

5. دستورالعمل های عملیاتی

Once the contacts are properly crimped onto wires and assembled into PowerPole housings (if applicable), they are ready for use. PowerPole connectors are designed for quick and reliable connection and disconnection.

  • اتصال: Align the PowerPole connectors (with contacts inserted) and push them firmly together until they lock. Ensure correct polarity (typically red for positive, black for negative).
  • قطع شدن: Pull the PowerPole connectors apart with a firm, steady motion. Avoid pulling directly on the wires.

These contacts are designed for high current applications, ensuring minimal resistance and heat generation when properly installed.

6. تعمیر و نگهداری

Anderson Power Products 5915-BK contacts require minimal maintenance. However, periodic inspection can help ensure long-term reliability:

  • بازرسی بصری: Periodically check contacts and connections for signs of corrosion, discoloration, or physical damage.
  • پاکیزگی: Keep contacts free from dirt, dust, and moisture. Use a clean, dry cloth for cleaning.
  • اتصالات امن: Ensure that contacts remain securely seated within their housings and that crimps are still firm.
  • جلوگیری از بارگذاری بیش از حد: از 75 تجاوز نکنید Ampere rating to prevent overheating and potential damage.

7 عیب یابی

If you experience issues with your PowerPole connections, consider the following:

  • Poor Connection/Intermittent Power:
    • Check crimp quality: Ensure the wire is securely crimped to the contact. Re-crimp if necessary.
    • Verify contact seating: Make sure the contact is fully inserted and locked into the PowerPole housing.
    • Inspect for corrosion: Clean any corrosion on the contact surfaces.
  • Overheating Connections:
    • Check wire gauge: Ensure the wire gauge (10 or 12 AWG) is appropriate for the current draw.
    • Verify current draw: Confirm that the current flowing through the connection does not exceed 75 Ampارس
    • Inspect crimp: A poor crimp can lead to high resistance and heat.
  • مشکل در اتصال/قطع اتصال:
    • Check for debris: Ensure no foreign objects are obstructing the connection.
    • Inspect housing: Verify that the PowerPole housings are not damaged or deformed.

8. مشخصات

نام تجاریمحصولات قدرت اندرسون
شماره مدل5915-BK
سازگاری گیج سیم10 AWG, 12 AWG
رتبه بندی فعلی75 Ampارس
نوع رابطچین دار
مواد تماسمس
مواد عایقغیر عایق
ابعاد بسته بندی6 x 3 x 0.5 اینچ
وزن مورد0.16 ounces (per 5 pieces)

۹. اطلاعات پشتیبانی

For further assistance or inquiries regarding Anderson Power Products, please refer to the official manufacturer's website or contact their customer support. Specific warranty information is not provided in the product data.

سازنده: Anderson Power Products, Inc.

اسناد مرتبط - 5915-BK

قبلview مرجع مشخصات پرس و عمق ابزار برای اتصالات برق و زمین SBS محصولات اندرسون پاور
Comprehensive guide detailing Anderson Power Products SBS power and ground contacts crimp specifications, including dimensional requirements, pull-out force, resistance, and nominal tool depth references for pneumatic and hand tools. Includes quality verification methods and acceptance criteria.
قبلview ابزار پرس هیدرولیک محصولات اندرسون پاور ۱۳۶۸: دستورالعمل پرس کردن
دستورالعمل‌های دقیق برای استفاده از ابزار پرس هیدرولیک Anderson Power Products 1368، شامل راه‌اندازی، مراحل پرس و نصب آداپتور موقعیت‌یاب B00508G. مناسب برای اندازه‌های تماس #4 تا 4/0 AWG.
قبلview دستورالعمل مونتاژ کانکتورهای SBE® برای سری‌های SBE 160 و SBE 320
دستورالعمل‌های دقیق مونتاژ برای کانکتورهای باتری دو قطبی سری SBE® 160 و SBE 320 از محصولات Anderson Power، شامل مشخصات، پرس، مونتاژ و نصب کنتاکت کمکی.
قبلview Anderson Powerpole PP75 Connectors: Specifications, Ordering, and Accessories
Detailed datasheet for Anderson Powerpole PP75 connectors, covering specifications, wire ranges, housing types, contacts, temperature charts, and accessories. Rated up to 120 Amps.
قبلview Anderson Power Products SB350 Cable Assembly Specifications
Technical specifications and outline for Anderson Power Products SB350 charging cable assemblies, detailing part numbers, connector types, cable specifications, ratings, and compliance information.
قبلview Powerpole® Modular Connectors Datasheet
Product specifications and part numbers for Anderson Power Products' Powerpole® Modular Connectors, including 25 amp Printed Circuit Board Contacts, 25 amp Printed Circuit Board Reel Contacts, 30 amp Series Connectors, and 30 amp مخاطبین