EXTECH-LOGO

EXTECH RHT510 HygroThermometer

EXTECH-RHT510-HygroThermometer-PRODUCT

Product Usage Instructions

Introduction
Thank you for selecting the Extech Model RHT510. This hand-held device measures Relative Humidity, Air temperature, Dew point temperature, Wet bulb temperature, and Type K temperature (using external probe). This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version and translations of this User Manual, Product Updates, Product Registration, and Customer Support.

Features

  • Backlit LCD with Display Hold
  • Lightweight, ergonomic design with lanyard
  • Displays Relative Humidity and Temperature (Air, Type-K, Dew point, and Wet bulb)
  • Selectable temperature units C/F
  • MAX-MIN Recording
  • Tripod Mounting
  • Battery operated

Safety
Please read the entire User Manual and Quick Start before operating this device. Use the meter only as specified and do not attempt to service or open the meter housing. Do not allow children to handle the meter. Please dispose of batteries and meters responsibly, and by all applicable laws and regulations.

Meter Description

  1. Air Temperature/Humidity Sensor
  2. Type K Temperature Probe Input
  3. LCD Display
  4. ON-OFF button
  5. EXTECH-RHT510-HygroThermometer-FIG- (7)button
  6. Mode button
  7. Backlight button
  8. SET and EXTECH-RHT510-HygroThermometer-FIG- (8) button
  9. Record button (MAX-MIN)
  10. Display Hold buttonEXTECH-RHT510-HygroThermometer-FIG- (1)

Note: Battery compartment and tripod mount on the back of the meter

LCD Description

  1. Type K Temperature Icon
  2. Function Icons
  3. MAX-MIN Record Icon
  4. MAX Display Icon
  5. MIN Display Icon
  6. Display Hold Icon
  7. Battery Status Indicator
  8. Auto Power OFF (APO)
  9. Primary Display
  10. Secondary DisplayEXTECH-RHT510-HygroThermometer-FIG- (2)

Operation

Basic Use

  1. Short press theEXTECH-RHT510-HygroThermometer-FIG- (3) power button to power the meter. If the LCD does not switch on, check the batteries located in the rear battery compartment.
  2. Place the sensor in the testing environment.
  3. View the measurement on the meter’s display.
  4. To power OFF the meter, short press theEXTECH-RHT510-HygroThermometer-FIG- (3) button.

Mode Selection
Press the M button to select the mode of operation. The meter has four (4) modes: Relative Humidity %, Dew point temperature, Wet bulb temperature and Type K temperature (external probe required). Release the M button to make a selection.

Display Hold
Short-press the H button to freeze or unfreeze a reading on the display. The Display Hold and APO functions are not operational in record mode.

LCD Backlight
The LCD is equipped withEXTECH-RHT510-HygroThermometer-FIG- (4) backlighting for easier viewing, especially in dimly lit areas. Press the backlight button to turn the backlight on. The backlight will automatically turn off after 10 seconds.

Type K Measurement
Insert the optional Type K temperature probe into the Type K temperature probe socket (left side of meter). Use the mode (M) button to set the mode of operation to Type K temperature and view the readings on the display.

MAX-MIN Recording
The meter records the maximum and minimum values over time.

Note:
Display Hold, Auto Power OFF setup, and the Power button do not function in Record mode.

  1. Press the R button to enter the Record mode. The record icon will appear on the display. The maximum and minimum values will be recorded and updated during the measurement period.
  2. Press the R button to display the maximum value recorded over time. TheEXTECH-RHT510-HygroThermometer-FIG- (5) icon and maximum value will appear on the display.
  3. Press the R button to display the minimum value recorded over time. TheEXTECH-RHT510-HygroThermometer-FIG- (6) icon and minimum value will appear on the display.
  4. Press the H button to reset the recorded data. The previously recorded MAX-MIN readings will be cleared, and the meter will start recording new MAX-MIN readings.
  5. Long-press the R button to exit the record mode.

Auto Power OFF Control
To conserve battery life, the meter will automatically shut off after approximately 10 minutes of inactivity. The APO icon appears in the display when APO is selected. To set APO ON or OFF as the default condition:

  1. Long-press press SET button to enter APO mode. The bottom display will show ‘PoFF’.
  2. Press the EXTECH-RHT510-HygroThermometer-FIG- (7) or EXTECH-RHT510-HygroThermometer-FIG- (8) button to turn the APO ON (YES) or APO OFF (NO).
  3. Press the R button to save the selection.
  4. Wait approximately 10 seconds for the meter to return to normal operation.

Temperature Units Selection (C/F)

  1. Long-press press SET button. The bottom display will show ‘PoFF’.
  2. Press the R button. The bottom display will show t-CF.
  3. Press the EXTECH-RHT510-HygroThermometer-FIG- (7) or EXTECH-RHT510-HygroThermometer-FIG- (8)button to select C or F.
  4. Press the R button to save the selection.
  5. Wait approximately 10 seconds for the meter to return to normal operation.

Maintenance

Battery Replacement

  1. Power OFF the meter.
  2. Remove the flat head screw that secures the battery compartment at the back of the meter.
  3. Open the battery compartment and replace the 3 AAA batteries, observing correct polarity.

Reassemble the meter before use.
Safety: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may explode or leak. If the meter is not to be used for 60 days or more, remove the batteries and store separately. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold.

EXTECH-RHT510-HygroThermometer-FIG- (9)Disposal:
Do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment.

Cleaning and Storage
Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents.

Specifications

Electrical Specifications (23±5°C)

Humidity/Air Temperature
Unit Range Resolution Accuracy
%RH 10 to 95 0.1 <70%: ±(4%RH)

≥70%: ±(4%rdg + 1.2%RH)

Temp oC 0 to 50 0.1 ±1.2oC
Temp oF 32 to 122 0.1 ±2.5oF
Type K Thermocouple (external probe)
Unit Range Resolution Accuracy*
 

Type K Temp oC

-50.0 to 1300.0 0.1 ±(0.4%rdg + 0.5 oC)
-50.1 to -100.0 0.1 ±(0.4%rdg + 1.0 oC)
 

Type K Temp oF

-58.0 to 2372.0 0.1 ±(0.4%rdg + 1.0 oF)
-58.1 to -148.0 0.1 ±(0.4%rdg + 1.8 oF)
*Accuracy spec. Does not include additional errors introduced by the external probe
Dew Point Temperature
oC -25.3 to 49.0 0.1 Calculation based on humidity/temp values.
oF -13.5 to 120.0 0.1
Wet Bulb Temperature
oC -5.4 to 49.0 0.1 Calculation based on humidity/temp values.
oF 22.2 to 120.0 0.1

General Specifications

Display Backlit LCD 35 x 30mm (1.38 x 1.18”)
Measurements Humidity/Temp; Dew Point; Wet Bulb; Type K Temp.
Input Overload Display “—-
Tripod Mount On the rear panel
Power 1.5V AAA batteries (3)
Power Consumption Approx. 5mA DC
Automatic Power Off After approx. 10 minutes of inactivity
Operating Temperature 0 to 50oC (32 to 122oF)
Operating Humidity 95% RH max
Storage Temperature -10 to 60oC (14 to 140oF)
Storage Humidity 10 to 75% RH
Dimensions/Weight 153 x 45 x 20mm (6.0 x 1.8 x 1.2”) /160g (5.64oz)
  • Copyright © 2017 FLIR Systems, Inc.
  • All rights reserved, including the right of reproduction in whole or in part in any form, ISO 9001 Certified
  • www.extech.com

FAQS

Q: How do I replace the batteries?
A: To replace the batteries, open the rear battery compartment and replace with new batteries following the correct polarity.

Q: Can children handle this meter?
A: It is advised not to allow children to handle this meter for safety reasons.

Documents / Resources

EXTECH RHT510 HygroThermometer [pdf] User Manual
RHT510, RHT510 Hygro Thermometer, RHT510, Hygro Thermometer, Thermometer