EXSYS-LOGO

EXSYS EX-61004 Serial Device Server

EXSYS-EX-61004-Serial-Device-Server-PRODUCT

Description

The EX-61004 is a multiprotocol RS-232/422/485 serial device server for integrating RS-232/422/485 serial devices, such as barcode scanners, weighing systems and payment terminals, into an IP-based Ethernet network. The serial devices are connected to the network and are available for sharing on the subnet and the Internet. Extensive network protocols such as TCP Server, TCP Client, UDP, VCOM, Remote Pair Master-Slave, Modbus Server, Modbus Client and SNMP are supported.

In addition, serial devices with remote pair master-slave mode can communicate with each other via peer-to-peer mode without the need for an intermediate PC or conversion software. With the Virtual COM (VCOM) software available for download, a perfectly migrated virtual serial port can be created on Windows computers for each serial device.

Features

  • 4x RS-232/422/485 port via RJ45 Ethernet 10/100Mbps
  • Up to 921.6 Kbps baud rate
  • Serial modes: RS-232, RS-422, RS-485 2-wire
  • Ethernet protocols: ARP, IP, ICMP, UDP, TCP, HTTP, DHCP, SNMP, MQTT, MODBUS
  • Operating modes: VCOM, MCP, TCP Server, TCP Client, UDP, Remote Pair mode, Modbus TCP Server, Modbus TCP Client
  • Configuration: Windows-based VCOM administrator utility and web browser
  • Certificate forEXSYS-EX-61004-Serial-Device-Server-FIG- (1)

Extent of delivery

Before you integrate the EX-61004 into your network, you should first check the contents of the delivery:

  • EX-61004
  • 4x RJ45 to DB9 adapter cable 20 cm
  • Power Supply (12V/1A)
  • Wall mounting brackets
  • Quick Start Guide

Layout, Connections & LED’sEXSYS-EX-61004-Serial-Device-Server-FIG- (1)

LED’s

LED NameColorLED Function
Activity LED (RJ45) 

Yellow

Steady on: Network is connected

Blinking: Transferring data on the Network

Off: No connection

LAN LED (RJ45) 

Green

Steady on: Network ist connected

Off: No connection

 

Power LED

 

Red

Steady on: Device is powered

Off: No power connected

 

RUN LED

 

Green

Steady on: Device is booting

Blinking: Server is ready for end devices

Off: Server is not ready

Connections

Serial
EXSYS-EX-61004-Serial-Device-Server-FIG- (3)

Serial RJ45 Port
PinRS232RS422RS485PinRS232RS422RS485
1TxDTxD+Data+5DSR  
2RxDTxD-Data-6GNDGNDGND
3RTSRxD+ 7DTR  
4CTSRxD- 8DCD  

Ethernet

EXSYS-EX-61004-Serial-Device-Server-FIG- (4)

RJ45 Port
PinSignalPinSignalPinSignal
1BI_DA+4BI_DC+7BI_DD+
2BI_DA-5BI_DC-8BI_DD-
3BI_DB+6BI_DB- 

+12V to +48V DC socket

ATTENTION!
Only for use with the power supply unit included in the scope of delivery or another compliant power supply unit!

EXSYS-EX-61004-Serial-Device-Server-FIG- (5)

+12V to +48V T-Block

ATTENTION!
Never connect power to the enclosure earth, this can destroy your hardware!

EXSYS-EX-61004-Serial-Device-Server-FIG- (6)

Hardware Installation

Please observe the following installation instructions. Since there are major differences between PCs, we can only give you general instructions for connecting the EX-61004. If anything is unclear, please refer to the operating instructions of your computer system.

  1. Install the EX-61004 on a wall or a device shelf.EXSYS-EX-61004-Serial-Device-Server-FIG- (7)
  2. Connect your serial devices to the device server. If necessary, use the adapter cables supplied.
  3. Connect the EX-61004 to your network using an RJ45 Ethernet CAT.5/6 patch cable.
  4. Now connect the 12V power supply included in the scope of delivery to the 12V socket provided for this purpose on the EX-61004.
  5. Alternatively, you can connect the EX-61004 device server to an existing DIN-Rail power supply unit 12-48 VDC via the terminal block.
  6. The LED display shows the status of the device server (see page 18).

Configuration of the Device Server
The EX-61004 is delivered with the following factory settings: By pressing and holding the “Reset” button for 5 seconds, the device will be reset to the factory settings.

Login User Name:admin
Password:admin
IP Address:DHCP
Network Operation Mode:VCOM
Serial Interface:RS232

Configuration

  • Install the VCOM software (download, see below) as administrator (right-click, “run as administrator”). Then restart the computer.
  • As soon as you have connected the server (details can be found on the next pages), you can access the unit via the button “Open in Browser”.
  • If you know the IP address assigned by the DHCP server, you can also type it directly into your browser and log into the unit.

For the Virtual COM Utility go to
www.exsys.ch/en or www.exsys.de/en Search for: EX-61004 Alternatively, you can scan the QR Code on the right:

EXSYS-EX-61004-Serial-Device-Server-FIG- (8)

VCOM Utility
For virtual COM applications, a VCOM utility is provided on the EXSYS website (download see page 20).
Important! Please run the installation programme by right-clicking “Run as administrator”! After completing the installation, restart the computer.

EXSYS-EX-61004-Serial-Device-Server-FIG- (9)

Get the IP address

  • Start the VCOM Utility (right-click on the VCOM Utility shortcut on the Windows desktop and start it with „Run as Administrator“).
  • Click Remote Device Management > ADD Device > Search
  • After the device is found, click Cancel to abort the search. Click OK, to add the EX-61004.EXSYS-EX-61004-Serial-Device-Server-FIG- (10)

VCOM Utility

Assignment of COM-Ports
To create the virtual COM port and assign it to the serial device, click COM Mapping > Add COM > OK

EXSYS-EX-61004-Serial-Device-Server-FIG- (11)

COM2-COM5 have now been added

EXSYS-EX-61004-Serial-Device-Server-FIG- (12)

VCOM Utility
Check whether the COM ports have been added to the device manager! The following entries should now be visible in the device manager:

EXSYS-EX-61004-Serial-Device-Server-FIG- (13)

Server Settings
To change the settings of the serial device server, you must log into the web interface. To open the web configuration menu, click on Remote Device Management in the VCOM software, if you have connected several device servers, select the one you want to access from the list and then click on Open in Browser. Your Internet browser opens and the login window appears. The factory-set login data is:

  • User Name: admin
  • Password: admin

If you know the IP address assigned by the DHCP server, you can also enter it directly into your browser and log in to the unit.

EXSYS-EX-61004-Serial-Device-Server-FIG- (14)

Server Settings

System Home – System Information
General information about the system

EXSYS-EX-61004-Serial-Device-Server-FIG- (15)

System Settings – IP Address Settings
Choose between automatic IP assignment via DHCP or static IP.

EXSYS-EX-61004-Serial-Device-Server-FIG- (16)

Server Settings
System Settings – Address Filter Limit access to the device server by setting authorised IP address ranges.

EXSYS-EX-61004-Serial-Device-Server-FIG- (17)

System Settings – User Management
Create new users and define their authorisation.

EXSYS-EX-61004-Serial-Device-Server-FIG- (18)

Server Settings
Serial Port Settings

AliasSet the serial port alias
Interface typeInterface type (RS232/485/422)
Baud rateSerial port baud rate (the value should be the same as the baud rate of the device

connected)

Data bitData bits (the value should be the same as the baud rate of the device connected),

default is 8

Parity checkCheck bits (none, even, odd), (the value should be the same as the baud rate of

the device connected), default is none

Stop bitStop bit (the value should be the same as the baud rate of the device connected),

default is 8

RST ControlAuto, XON/XOFF, CTS/RTS can be selected
Interval timeData packing interval (if required, default is 0)
Packing lengthLength of data pack (if required, default is 0)
Delimiter enablingEnable packet separation by delimiter if required
DelimiterSet the encoding of the delimiter for the transmitted data (0-0xff)
Delimiter handlingChose to keep und discard
Apply to all serial portsApplies the settings for all serial ports of the device server

EXSYS-EX-61004-Serial-Device-Server-FIG- (19)

Operation mode
Set up the desired operating mode of the serial interfaces.

EXSYS-EX-61004-Serial-Device-Server-FIG- (20)

Device Management

Firmware UpgradeInstalling new device firmware.

Select the locally stored installation package of the new firmware and click on “Start” to perform the upgrade.

Attention! During the upgrade, the device server must always be connected to the network and to the power supply, otherwise the device may be destroyed.

We cannot accept any responsibility for incorrectly executed updates.

Restore FactoryResetting the unit to factory defaults
Port RestartRestarting individual ports (e.g. in case of a malfunction)
System RestartReboot the serial device server

EXSYS-EX-61004-Serial-Device-Server-FIG- (21)

Cleaning
To clean the device, please use only a dry, non-fibrous cloth and remove the dirt with light pressure. In the area of the connections, please make sure that no fibres of the cloth are left in the socket.

Attention!
Never use a moist or wet cloth for cleaning!

Technical Information

  • Data Transfer Rate: 50 to 921.6 Kbps baud rate
  • Connectors: 4x RJ45 serial ports (via adapter cables), 1x RJ45
  • Ethernet port, 1x 12-48V DC Connector, 1x Terminal Block 12-48V
  • Hardware System: Ethernet 10/100 Mbit/s
  • VCOM Utility: Windows XP/Vista/7/8.x/10/11/Server 20xx
  • Operating System: All via IP and Port Number (Direct Control Socket Port)
  • Operating Temperature: -40° to 185° Fahrenheit
  • Storage Temperature: -40° to 185° Fahrenheit
  • Rel. Humidity: 5% to 95%, non-condensing
  • Protection Class: IP30
  • Power: +12-48V
  • Size: 161 x 91 x 37 mm
  • Weight: 530g

Technical Drawing

EXSYS-EX-61004-Serial-Device-Server-FIG- (22)

Copyright 2023 by EXSYS Vertriebs GmbH. All rights reserved

Documents / Resources

EXSYS EX-61004 Serial Device Server [pdf] Instruction Manual
EX-61004, EX-61004 Serial Device Server, Serial Device Server, Device Server, Server

References

Leave a comment

Your email address will not be published. Required fields are marked *