EXFO LOGOQuick Reference Guide
HIGH-SPEED MULTISERVICE TEST MODULE
Power Blazer
FTBx-88460

Physical Interfaces

Connect the signal to the corresponding interface on the module. Insert an EXFO supported transceiver into the port’s slot, then carefully connect optical fiber cables to the transceiver IN (RX) and OUT (TX) ports.

EXFO High Speed Multiservice Test Module - Fig5

a. Requires revision B of the FTBx-88460 module and TA4-OSFPv2/TA4-QSFP-DDv2/TA4-CFP2v2.
b. Requires a QSFP28 to SFP28 transceiver adapter.

Starting the Application

EXFO High Speed Multiservice Test Module - Fig6

Configuring and Starting a Test

EXFO High Speed Multiservice Test Module - Fig7

For Intelligent Apps:
EXFO High Speed Multiservice Test Module - Fig8For Transport / Ethernet: 

EXFO High Speed Multiservice Test Module - Fig9

Getting Results

EXFO High Speed Multiservice Test Module - Fig1

Alarm/Error Injection

EXFO High Speed Multiservice Test Module - Fig2

Status Bar

EXFO High Speed Multiservice Test Module - Fig3

Global Indicator

The global indicator displays the pass/fail verdict, global alarm, timer, and/or test duration

EXFO High Speed Multiservice Test Module - Fig4

Test Control Buttons

EXFO High Speed Multiservice Test Module - Button Start Stop Starts test. Available when the test is not running. Stops test. Available when the test is running.
EXFO High Speed Multiservice Test Module - Button1 Save Load Saves, loads, imports, exports, and deletes configuration file(s). Available when the test is not running.
EXFO High Speed Multiservice Test Module - Button2 Report Saves, opens, imports, exports, and deletes test report(s). Available when the test is running or stopped, but the report generation (save) is only possible when the test is stopped.
EXFO High Speed Multiservice Test Module - Button3 Laser (on) Indicates that the laser control is on (for at least one lane for parallel interface); the laser button has a red border. Tapping this button will turn off the laser (for all lanes for parallel interface).
EXFO High Speed Multiservice Test Module - Button4 Laser (off) Indicates that the laser control is off (for all lanes for parallel interface). Tapping this button will activate the laser immediately by emitting an optical laser signal (on all lanes for parallel interface).
EXFO High Speed Multiservice Test Module - Button5 Reset Clears results, statistics, and logger content. Available when the test is running.
EXFO High Speed Multiservice Test Module - Button6 Inject Injects alarms/errors based on settings from the Inject button from the Results – Alarms/Errors tab.
EXFO High Speed Multiservice Test Module - Button7 More/ Less The More/Less button appears when there is not enough room to display all available test control buttons.

EXFO LOGO©2022 EXFO Inc. Al rights reserved
Printed in Canada (2022-08)
PIN: 1082796
Version: 12.0.0.1
For more information,
refer to the user guide.