Sarrera

This manual provides detailed instructions for the installation, operation, and maintenance of your Intermatic Photoelectric Outdoor Timer. This device is designed to automatically control outdoor lighting or other electrical appliances, turning them on at dusk and off after a selected duration (2, 4, 6, or 8 hours) or at dawn. It features an easy-set dial for convenient programming and is suitable for outdoor use.

Segurtasun Informazioa

KONTUZ: This timer must be mounted in a vertical position with the receptacle facing downward. Ensure that the receptacle does not reach the ground level to prevent water accumulation and electrical hazards. Always disconnect power before installation or servicing.

Produktuaren Ezaugarriak

Konfigurazioa eta Instalazioa

Follow these steps to properly set up your Intermatic Photoelectric Outdoor Timer:

Intermatic Photoelectric Outdoor Timer in packaging

Image: Intermatic Photoelectric Outdoor Timer. This image shows the timer in its original packaging, highlighting its design and key features.

  1. Prestatu tenporizadorea: Before plugging in, turn the dial selector to the "OFF" position.
  2. Plug into Receptacle: Insert the timer's plug into a grounded outdoor electrical receptacle. Ensure the receptacle is mounted vertically with the timer's outlet facing downwards, and the timer does not touch the ground.
  3. Set Timing Mode: Turn the dial selector to your desired timing mode. Options include:
    • 2 HR: Lights turn on at dusk and stay on for 2 hours.
    • 4 HR: Lights turn on at dusk and stay on for 4 hours.
    • 6 HR: Lights turn on at dusk and stay on for 6 hours.
    • 8 HR: Lights turn on at dusk and stay on for 8 hours.
    • Iluntzetik iluntzera: Lights turn on at dusk and stay on until dawn.
  4. Konektatu etxetresna elektrikoak: Plug your outdoor lights or other appliances into the timer's outlet. The timer will now operate according to your selected setting.

Funtzionamendu-argibideak

The Intermatic Photoelectric Outdoor Timer operates automatically based on ambient light levels and your chosen setting.

Mantentzea

To ensure optimal performance and longevity of your timer:

Arazoak konpontzea

If your Intermatic Photoelectric Outdoor Timer is not functioning as expected, consider the following:

If issues persist, contact Intermatic customer support.

Zehaztapenak

EzaugarriXehetasuna
Modelo zenbakiaCECOMINOD045609
Zati zenbakiaHB51RC
liburukiatage120V
Amparoa8A
Wattage1000W
Elementuaren pisua8 ontza
Produktuaren neurriak6.2 x 7.4 x 10 hazbete
KoloreaBeltza edo zuria
Beharrezko bateriakEz
FabrikatzaileaINTERMATIC INC

Bermea eta Laguntza

For warranty information or technical support, please refer to the official Intermatic webwebgunera edo jarri harremanetan bezeroarentzako arreta-zerbitzuarekin. Gorde erosketa-agiria berme-erreklamazioetarako.

Erlazionatutako dokumentuak - CECOMINOD045609

Aurreview Intermatic HB61 Digital Outdoor Light Sensor: Operation and Features
Detailed guide for the Intermatic HB61 Digital Outdoor Light Sensor. Learn about its operation, automatic and manual timing modes, and safety precautions for security, holiday, and landscape lighting.
Aurreview Intermatic ST01/ST01K/E1600 In-Wall Timer with Astro Feature: Installation and User Guide
Comprehensive guide for installing and operating the Intermatic ST01, ST01K, and E1600 In-Wall Timers. Features include 24/7 programming, astro functions, and compatibility with various lighting types.
Aurreview Intermatic K4251/K4253 Photoelectric Control Installation and Operation Guide
Comprehensive guide for Intermatic K4251 and K4253 photoelectric controls, covering installation, applications, troubleshooting, and warranty information. Ensure safe and efficient operation of your outdoor lighting.
Aurreview Intermatic EI200 Electronic In-Wall Countdown Timer Installation and Operation Guide
Detailed guide for installing and operating the Intermatic EI200 electronic in-wall countdown timer. Features include 5-30 minute time ranges, continuous HOLD mode, and ratings for 15A general purpose, 1000W tungsten, and 1/4 HP motors. Includes warranty information.
Aurreview Intermatic EJ351 Barruko Hormako Etengailu Tenporizadorea: Instalazio, Programazio eta Arazoak Konpontzeko Gida
Intermatic EJ351 Barruko Hormako etengailu-tenporizadorea instalatzeko, programatzeko eta arazoak konpontzeko gida osoa. Ikasi ordutegiak nola ezarri, modu automatikoak eta eskuzkoak nola erabili eta ohiko arazoak nola konpondu.
Aurreview Intermatic T105 24-Hour Dial Time Switch: Installation, Wiring, and Operation Guide
Comprehensive guide for the Intermatic T105 24-hour mechanical dial time switch. Covers model specifications, safety warnings, wiring instructions for various configurations (SPNO, SPNC, SPDT), programming procedures, and manual operation. Includes a detailed table of electrical ratings and wire gauge recommendations.