1. Introducción
The UNI-T UT202R is a high-precision digital clamp meter designed for accurate electrical measurements. It features automatic ranging, True RMS capabilities, and a clear LCD backlight display. This manual provides essential information for the safe and effective operation of your device.
2. Información de seguridad
Always adhere to local and national safety codes. Use appropriate personal protective equipment (PPE) such as insulated gloves and eye protection. Do not attempt to measure voltages or currents exceeding the specified maximum ratings. Ensure the device is in good working condition before use. Refer to the safety markings on the device and in the full product documentation.
- CAT III 300V / CAT II 600V: Indicates the measurement category and maximum voltage para una operación segura.
- No utilizar si está dañado: Inspect the meter and test leads for any damage before each use.
- Evite las condiciones húmedas: Do not operate the meter in wet environments.
- Seguridad de la batería: Reemplace las baterías cuando aparezca el indicador de batería baja.
3. Producto terminadoview
3.1. Componentes

Imagen: Detallada view of the UNI-T UT202R Digital Clamp Meter with labels pointing to its various parts, including the clamp head, NCV sensor, NCV warning lamp, function turntable, function switch button, LED display, relative value button, Max/Min button, data hold/backlight button, black probe socket, and red probe socket.
- Clamp Cabeza: Se utiliza para medición de corriente sin contacto.
- Sensor de velocidad de conducción nerviosa: Vol sin contactotage detección.
- NCV Warning Lamp: Se ilumina durante la detección de NCV.
- Tong Head Trigger: Abre el clamp mandíbula.
- Function Turntable (Dial): Selecciona los modos de medición.
- Function Switch Button (SELECT): Toggles between functions within a dial setting.
- Pantalla LED: High-definition display for measurement readings.
- REL/Zero Button: For relative measurement or zeroing.
- Botón MÁX./MÍN.: Registra valores máximos y mínimos.
- Botón HOLD/Iluminación de fondo: Freezes the display reading or activates backlight.
- Probe Sockets (COM, VΩHz): Conecte los cables de prueba para vol.tage, resistance, frequency, and other measurements.
3.2. Características de la pantalla
- Pantalla LCD HD: Proporciona mediciones claras y fáciles de leer.
- Función de luz de fondo: Mejora la visibilidad en condiciones de poca luz.
- Larger Screen and Display Digits: Improves readability of measurement values.
4. Configuración
4.1. Instalación de la batería
The UNI-T UT202R requires 2 AA batteries (included). To install or replace batteries:
- Asegúrese de que el medidor esté apagado.
- Localice la tapa de la batería en la parte posterior del dispositivo.
- Utilice un destornillador para abrir la tapa de la batería.
- Inserte las 2 pilas AA, observando la polaridad correcta (+/-).
- Cierre de forma segura la tapa de la batería.
5. Instrucciones de funcionamiento
This section details the various measurement functions of the UNI-T UT202R Digital Clamp Meter. Always select the appropriate function on the dial before making any measurements.
5.1. Medición de corriente CA
To measure AC current, rotate the function dial to the 'A~' position. Open the clamp jaw using the trigger and enclose a single conductor. The display will show the AC current reading. The meter supports selectable frequency for AC current measurements.
Video: Demonstration of AC current measurement using the clamp meter on an electrical panel, showing the current reading on the display. The video also highlights selectable frequency.
5.2. Vol. CAtagMedición electrónica
Para medir el voltaje CAtage, rotate the function dial to the 'V~' position. Connect the red test lead to the VΩHz input jack and the black test lead to the COM input jack. Apply the test leads across the circuit points to measure AC voltage. The meter supports selectable frequency for AC voltagy mediciones.
Video: Demonstration of AC voltage measurement using test leads on an electrical panel, showing the voltage reading on the display. The video also highlights selectable frequency.
5.3. Vol. CCtagMedición electrónica
Para medir DC voltage, rotate the function dial to the 'V=' position. Connect the red test lead to the VΩHz input jack and the black test lead to the COM input jack. Apply the test leads across the circuit points to measure DC voltage. This is demonstrated on a car battery and an electric bicycle battery.
Video: Demonstration of DC voltage measurement on a car battery and an electric bicycle battery, showing the voltage readings on the display.
5.4. Medida de resistencia
To measure resistance, rotate the function dial to the 'Ω' position. Connect the test leads across the component to be measured. The display will show the resistance value in Ohms (Ω).
Video: Demonstration of resistance measurement on a circuit board, showing the resistance value on the display.
5.5. Medición de diodos
To test diodes, rotate the function dial to the 'Diode' symbol position. Connect the test leads across the diode. A healthy diode will show a voltaguna caída en una dirección y un circuito abierto (OL) en la dirección inversa.
Video: Demonstration of diode measurement on a circuit board, showing the voltage drop reading on the display.
5.6. Prueba de continuidad
To perform a continuity test, rotate the function dial to the 'Continuity' symbol position. Connect the test leads across the circuit or component. The meter will emit an audible beep if continuity is detected (low resistance).
Video: Demonstration of a continuity test using test leads on a wire, showing the audible beep and display reading for continuity.
5.7. Medición de capacitancia
To measure capacitance, rotate the function dial to the 'Capacitance' symbol position. Connect the test leads across the capacitor. The display will show the capacitance value. The UT202R supports capacitance measurement up to 4mF.
Video: Demonstration of capacitance measurement on a capacitor, showing the capacitance value on the display.
5.8. Medición de temperatura
To measure temperature, rotate the function dial to the 'Temperature' symbol position. Connect a K-type thermocouple (not included) to the meter. Place the thermocouple tip on the object or area to be measured. The display will show the temperature reading. The UT202R supports temperature measurement from -40°C to 1000°C.
Video: Demonstration of temperature measurement using a thermocouple on an air conditioning unit, showing the temperature reading on the display.
5.9. Medición de frecuencia
To measure frequency, rotate the function dial to the 'Hz%' position. Connect the test leads to the circuit. The display will show the frequency value. The UT202R supports frequency measurement up to 10MHz.
Video: Demonstration of low voltage frequency measurement using a signal generator, showing the readings on the display.
5.10. Vol sin contactotagMedición de e (NCV)
Para detectar el volumen de CAtage without contact, rotate the function dial to the 'NCV' position. Bring the NCV sensor near the conductor. The NCV warning lamp will illuminate, and the meter will beep, indicating the presence of AC voltage. The UT202R features 4-level NCV measurement for varying signal strengths.
Video: Demonstration of 4-level NCV measurement on electrical busbars, showing the NCV indicator and audible alerts.
5.11. Current Usage with Splitter (Optional Accessory)
For convenient measurement of home appliance current usage, the UT200+ series can be used with a splitter (e.g., UNI-T UT-LS15-US, sold separately). This accessory separates the live and ground wires, allowing the clamp meter to accurately measure the current of a plugged-in appliance.
Video: Demonstration of measuring current usage of a home appliance using the clamp meter with a UT-LS15-US splitter.
6. Especificaciones
The following table outlines the key specifications for the UNI-T UT202R Digital Clamp Metro.

Image: Detailed specifications table for the UT200+ and UT200R series, including AC current, AC current frequency response, DC current, AC voltage, vol. CAtage frequency response, high voltagfrecuencia electrónica, volumen de CCtage, resistance, capacitance, temperature, frequency, display count, jaw opening, relative mode, zero mode, and category ratings.

Image: Table outlining features such as auto range, True RMS, continuity test, diode, low battery indication, data hold, Max/Min, and auto power off. Also includes characteristics like standard accessories, batteries, display, product size, product net weight, standard individual packing, standard quantity per carton, standard carton measurement, and standard carton gross weight.
| Parámetro | Valor |
|---|---|
| Número de modelo | UT202R |
| Corriente CA (A) | 400A |
| Corriente continua (A) | No disponible |
| Vol. CAtagmi (V) | 600 V |
| Vol DCtagmi (V) | 600 V |
| Resistencia (Ω) | 40 MΩ |
| Capacitancia (F) | 4 mF |
| Temperatura (°C) | -40 °C ~ 1000 °C |
| Frecuencia (Hz) | 10 Hz ~ 10 MHz |
| Recuento de pantalla | 4000 |
| Apertura de mandíbula | 28 mm |
| Verdadero valor eficaz (RMS) | Sí |
| Iluminar desde el fondo | Sí |
| Fuente de poder | 2 pilas AA (incluidas) |
| Certificaciones | CE, UKCA, cETLus |
7. Mantenimiento
To ensure the longevity and accuracy of your UNI-T UT202R Digital Clamp Medidor, siga estas pautas de mantenimiento:
- Limpieza: Limpie el medidor con un paño seco y suave. No utilice abrasivos ni disolventes.
- Almacenamiento: Guarde el medidor en un lugar fresco y seco, alejado de la luz solar directa y de temperaturas extremas. Retire las pilas si lo va a guardar durante un periodo prolongado.
- Calibración: For professional applications, periodic calibration by qualified personnel is recommended to maintain accuracy.
- Cables de prueba: Inspect test leads regularly for cuts, cracks, or damaged insulation. Replace immediately if any damage is found.
8. Solución de problemas
If you encounter issues with your UNI-T UT202R, refer to the following common troubleshooting steps:
- Sin pantalla/Pantalla débil: Compruebe la instalación de las pilas y sustitúyalas si es necesario. Asegúrese de que el medidor esté encendido.
- Lecturas incorrectas:
- Ensure the correct measurement function is selected.
- Verify test lead connections are secure and undamaged.
- Check for proper contact with the circuit or component.
- Para mediciones de corriente, asegúrese de que solo un conductor esté dentro del clamp mandíbula.
- Visualización "OL" (Sobrecarga): El valor medido excede el rango seleccionado. Cambie a un rango superior o asegúrese de que la medición esté dentro de las capacidades del medidor.
- No hay pitido de continuidad: Check if the circuit is truly continuous or if the resistance is too high for the continuity threshold.
Si los problemas persisten, comuníquese con el servicio de atención al cliente de UNI-T o con un técnico calificado.