1. Introducción
The Renogy All-in-One Hybrid Solar Inverter integrates a 24V 3000W inverter, an 80A AC charger, and an 80A MPPT charge controller. It features high-efficiency MPPT technology (up to 99.9%) for maximum solar energy harvesting. With four charging modes and three output modes, it caters to diverse power needs. Comprehensive electronic protection functions ensure system safety and stability.

Figura 1: Renogy 24V 3000W All-in-One Hybrid Solar Inverter with key specifications and dimensions. This image displays the Renogy 24V 3000W All-in-One Hybrid Solar Inverter, highlighting its 3300W pure sine wave output, 80A MPPT solar charge controller, and 80A maximum AC charger. The dimensions are shown as 378 mm (height), 280 mm (width), and 103 mm (depth).
2. Información de seguridad
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, severe injury, or death. Keep this manual for future reference.
- La instalación debe ser realizada por personal calificado.
- Asegúrese de que todo el cableado tenga el tamaño correcto y esté conectado adecuadamente.
- No desmonte ni intente reparar la unidad usted mismo. Contacte con personal de servicio técnico cualificado.
- Keep the unit away from water, flammable materials, and corrosive substances.
- Asegúrese de que haya una ventilación adecuada alrededor del inversor para evitar el sobrecalentamiento.
- Desconecte siempre las fuentes de alimentación antes de realizar cualquier mantenimiento o cableado.
3. Características del producto
- All-in-One Hybrid Solar Solution: This system combines solar power and AC power input. It integrates an 80A MPPT solar charge controller, an AC/generator battery charger, and a battery inverter, providing a comprehensive solution for off-grid systems and Uninterruptible Power Supply (UPS) functionality.
- Compatibilidad de batería universal: Supports various battery types including AGM/Sealed, Gel, Lead-Acid, and Lithium, with a customizable user mode for optimal performance.
- Reliable Pure Sine Wave Output: Built on a fully digital intelligent design, the DC-AC inverter module utilizes advanced SPWM technology to produce a pure sine wave output, ensuring stable and clean power for sensitive electronics.
- Cuatro modos de carga: Offers four selectable charging modes: Solar Only, Mains Power Priority, Solar Priority, and Hybrid (Mains & Solar) Charging.
- Función de fuente de alimentación ininterrumpida (UPS): Features an integrated UPS function, allowing the device to seamlessly switch to battery power during a grid outage, preventing interruptions to connected computers and other critical appliances.
4. Configuración e instalación
Proper installation is crucial for the safe and efficient operation of your Renogy Hybrid Solar Inverter. Refer to the diagrams below for connection details.

Figura 2: Sistema completo terminadoview. This diagram shows how the Renogy Hybrid Solar Inverter integrates into a complete system. It depicts solar charging from PV panels, AC/grid charging, 24V battery storage, and AC output to various household appliances like refrigerators, lights, TVs, and fans. This illustrates the inverter's role in managing power flow from multiple sources to loads.
4.1 Puertos de conexión
Identify the various connection points on the back panel of the inverter as shown in Figure 3.

Figura 3: Back Panel Connections. This image provides a detailed view of the inverter's rear panel, clearly labeling all connection ports and controls. These include: 1. AC Input, 2. AC Output, 3. CAN Communication, 4. USB Communication, 5. RS485 Communication, 6. Dry Contact, 7. Grounding Terminal, 8. Overload Protection, 9. Fan, 10. Battery Connection, 11. Fan, 12. ON/OFF Rocker Switch, 13. PV Connection, 14. Touch Buttons, 15. LED Indicators, and 16. LCD Screen. This visual guide is essential for proper installation and wiring.
4.2 Conexión de la batería
The inverter supports various battery types. Ensure your battery type is correctly configured in the settings for optimal charging and discharge performance.

Figura 4: Battery Compatibility. This image highlights the inverter's compatibility with different battery types, including Flooded (FLD), GEL, Lithium Iron Phosphate, Lithium-ion, AGM/Sealed (SLD), and a customizable User-defined battery mode. This versatility ensures the inverter can be integrated into a wide range of solar power systems.
- Connect the battery cables to the Battery Connection terminals (10) on the inverter. Observe correct polarity.
- Asegúrese de que el volumen de la bateríatage matches the inverter's operating voltage (24 V).
4.3 Conexión fotovoltaica (panel solar)
- Connect your solar panel array to the PV Connection terminals (13).
- Asegúrese de que el voltaje del circuito abiertotage and short-circuit current of your solar array are within the inverter's specifications.
4.4 Conexión de entrada/salida de CA
- Connect the AC grid power to the AC Input Connection (1).
- Connect your AC loads to the AC Output Connection (2).
- Ensure all AC wiring is properly grounded and protected by circuit breakers.
5. Instrucciones de funcionamiento
The inverter features an intuitive LCD display and various operating modes to suit your power needs.
5.1 Pantalla LCD e indicadores
The LCD screen (16) and LED indicators (15) provide real-time status and information about the system.

Figura 5: LCD Display and LED Indicators. A detailed view of the inverter's dynamic LCD display and intelligent LED indicators. The LCD provides critical system information such as input/output data, load status, and battery voltage. The LEDs indicate AC/Inverter status, Charge status, and Fault conditions, allowing for quick identification of operational status and potential issues.
5.2 Modos de carga y salida
Select the appropriate charging and output modes using the touch buttons (14) on the control panel.

Figura 6: Charging and Output Modes. This diagram illustrates the four available charging modes: PV Priority, Grid Priority, Hybrid Charging, and Solar Only. It also shows three output modes: PV Priority, Grid Priority, and Inverter Priority. These modes allow users to select the most suitable power management strategy for their system.
Modos de carga:
- Solo solares: Prioriza la energía solar para la carga de la batería.
- Mains Power Priority: Prioritizes AC grid power for battery charging.
- Prioridad solar: Prioriza la energía solar tanto para la carga como para el suministro de cargas.
- Hybrid (Mains & Solar) Charging: Uses both solar and grid power for charging as needed.
Modos de salida:
- Prioridad fotovoltaica: Prioriza la energía solar para las cargas.
- Prioridad de la red: Prioritizes AC grid power for loads.
- Prioridad del inversor: Prioriza la energía de la batería (a través del inversor) para las cargas.
6. Mantenimiento
El mantenimiento regular garantiza la longevidad y el rendimiento óptimo de su inversor.
- Limpieza: Mantenga el exterior del inversor limpio y sin polvo. Asegúrese de que las aberturas de ventilación no estén obstruidas.
- Conexiones: Revise periódicamente todas las conexiones eléctricas para verificar su estanqueidad y ausencia de corrosión.
- Ambiente: Asegúrese de que el inversor funcione dentro de los rangos de temperatura y humedad especificados.
- Estado de la batería: Supervisar el volumen de la bateríatage y salud según las pautas del fabricante de la batería.
7. Solución de problemas
If you encounter issues, refer to the following common troubleshooting steps. For persistent problems, contact Renogy customer support.
| Problema | Posible causa | Solución |
|---|---|---|
| No hay salida de potencia del inversor | Battery low/disconnected, Overload, Inverter fault, AC input issue | Verifique las conexiones de la batería y el vol.tage. Reduce load. Check for fault codes on LCD. Verify AC input power. |
| Las baterías no se cargan con energía solar | PV panels disconnected/damaged, Incorrect PV voltage, Charge controller fault, Incorrect charging mode selected | Verifique las conexiones y el volumen del panel fotovoltaico.tage. Ensure PV voltage is within range. Check charge controller settings and selected charging mode. |
| La pantalla LCD no funciona | No power to inverter, Display fault | Check main power switch and battery connection. If power is present, contact support. |
| Advertencia/apagado por sobrecarga | Too many appliances connected, Short circuit in load | Disconnect some loads. Check for short circuits in connected appliances. Restart the inverter. |
8. Especificaciones
Key technical specifications for the Renogy 24V 3000W All-in-One Hybrid Solar Inverter.
| Especificación | Valor |
|---|---|
| Número de modelo del artículo | RIV2430HCS-2SS |
| Fabricante | Renogy |
| Volumentage | 24 voltios |
| Potencia de salida | 3000 W |
| Controlador de carga MPPT | 80A |
| Cargador de CA | 80A |
| Tipo de pantalla | Pantalla LCD |
| Dimensiones del producto (L x An x Al) | 37.8 x 28 x 10.3 cm |
| Peso del artículo | 7.4 kilogramos |
| Color | Negro, Azul |
| Pilas necesarias | No |
| Código Postal | 840315216822 |
| ASIN | B0CBJTPY5P |
| Fecha de primera disponibilidad | 10 de julio de 2023 |
9. Garantía y soporte
Renogy products are designed for reliability and performance. For warranty information, product registration, or technical support, please visit the official Renogy websitio o comuníquese con su departamento de servicio al cliente.
- Oficial Websitio: Www.renogy.com
- Atención al cliente: Consulte la sección de contacto en el sitio oficial. webSitio para obtener números de teléfono o soporte por correo electrónico.