WinAPEX ET8101/ET8102

WINAPEX 6000 Counts Digital Multimeter User Manual

Modelos: ET8101 / ET8102

Brand: WinAPEX

1. Másview

The WINAPEX 6000 Counts Digital Multimeter is a pocket-sized 3 5/6-bit automatic digital instrument designed for stable performance, high precision, and clear, reliable readings with overload protection. Powered by AAA 1.5V batteries, it features a large-screen LCD display with high brightness backlight, even in low battery conditions. The backlight can be automatically turned off after 15 seconds to conserve power. This series of instruments is versatile, capable of measuring DC voltage, vol. CAtage, DC current, AC current, resistance, capacitance, diode, continuity, zero fire wire judgment, frequency, and True RMS. The ET8102 model specifically includes temperature measurement functionality, while the ET8101 does not. It is an ideal tool for use in laboratories, factories, and by radio enthusiasts and families.

WINAPEX ET8102 Digital Multimeter showing various functions like AC/DC voltage, current, temperature, capacitance, diodes, continuity, data hold, backlight, frequency, NCV, and duty cycle.
WINAPEX ET8102 Digital Multimeter highlighting its various measurement functions.

2. Precauciones de seguridad

This instrument is designed to comply with IEC1010 safety standards. Please read the following precautions carefully before use:

  1. Al medir el volumentage, no exceda el límite vol.tage of DC 1000V or AC 750V RMS.
  2. Volumentages below 36V are considered safe. When measuring above 36V DC or 25V AC, ensure test leads have reliable contact, are correctly connected, and have proper insulation to prevent electric shock.
  3. When changing functions or ranges, ensure the test leads are removed from the test point.
  4. Always select the correct function and range to prevent accidental operation. While the instrument has full-range protection, caution is advised.
  5. Al medir la corriente, no introduzca más de 10 A.
  6. Descripción del símbolo de seguridad:
    • !: Indica volumen peligrosotage.
    • : Suelo.
    • :Doble aislamiento.
    • :El operador debe consultar el manual de instrucciones.
    • : Vol bajotage símbolo.

3. Configuración

3.1. Instalación de la batería

The multimeter requires AAA 1.5V batteries (not included). To install or replace batteries:

  1. Ubique el compartimiento de la batería en la parte posterior del multímetro.
  2. Abra la tapa de la batería.
  3. Insert the AAA 1.5V batteries, ensuring correct polarity as indicated inside the compartment.
  4. Cierre bien la tapa de la batería.
Back of the multimeter with the battery compartment open, showing where to insert batteries.
Battery compartment for AAA 1.5V batteries.

3.2. Conexión de los cables de prueba

Before performing any measurements, ensure the test leads are correctly connected to the multimeter:

  • Inserte el cable de prueba negro en el
    Documents - WinAPEX – ET8101/ET8102