Touch Screen Display and Communication Box
Touch Screen Display & Communication Box
Specifications
- Rated Input Voltage: Not specified
- Rated Power: Not specified
Product Information
Welcome to the user manual for the Touch Screen Display &
Communication Box, part of Epoch Batteries’ Pro Series battery
ecosystem. This guide provides clear instructions on installation,
configuration, and operation. By following these guidelines, you
can ensure the best possible performance and extend the lifespan of
your system.
The Touch Screen Display & Communication Box work together
as advanced monitoring devices for Epoch Pro Series batteries. With
these components, you gain real-time insights into critical battery
performance metrics, enabling you to manage your energy storage
system safely and effectively.
Installation
1. Direct Connection: Plug the Touch Screen Display directly
into the Pro Series battery using the supplied wiring harness. This
is ideal for straightforward systems that require minimal
setup.
2. Via Communication Box: For more advanced communication
protocols or complex systems, connect the Touch Screen Display to
the T-monitor port on the Communication Box. The Communication Box
then links to the Pro Series battery bank, creating a flexible
networking solution.
The Touch Screen Display provides an intuitive interface for
users to navigate through different parameters and settings related
to the Pro Series batteries. Use the touchscreen to access
real-time data and configure the system according to your
needs.
Warnings & Protections
Ensure that all connections are made securely and according to
the provided instructions to prevent any electrical hazards or
malfunctions. Follow safety guidelines when handling the Touch
Screen Display & Communication Box to avoid damage or
injury.
FAQ
Q: What should I do if the Touch Screen Display is
unresponsive?
A: If the Touch Screen Display is unresponsive, try restarting
the system by disconnecting and reconnecting the power source. If
the issue persists, contact customer support for further
assistance.
Touch Screen Display & Communication Box
Last Updated: March 3, 2025
Table of Contents
Introduction
3
Dimensions
5
Technical Specifications
6
Installation
7
Interface & Navigation
9
Warnings & Protections
11
Page 2
Introduction
Welcome to the user manual for the Touch Screen Display & Communication Box, part of Epoch Batteries’ Pro Series battery ecosystem. This guide provides clear instructions on installation, configuration, and operation. By following these guidelines, you can ensure the best possible performance and extend the lifespan of your system.
Overview
The Touch Screen Display & Communication Box work together as advanced monitoring devices for Epoch Pro Series batteries. With these components, you gain real-time insights into critical battery performance metrics, enabling you to manage your energy storage system safely and effectively.
Key parameters displayed include:
· State of Charge (SOC): Indicates the remaining battery capacity as a percentage.
· Voltage and Current: Shows the real-time electrical status of your battery system. · Remaining Capacity: Reveals how many ampere-hours (Ah) remain in the battery bank. · Temperature: Monitors internal battery temperature, helping to preserve battery health. · Configuration Data: Displays series/parallel setup details and other system settings.
All communication utilizes an RS485 interface, delivering reliable data transfer even in complex or noisy electrical environments.
Connection Methods
1. Direct Connection: Plug the Touch Screen Display directly into the Pro Series battery using the supplied wiring harness. This is ideal for straightforward systems that require minimal setup.
2. Via Communication Box: For more advanced communication protocols or complex systems, connect the Touch Screen Display to the T-monitor port on the Communication Box. The Communication Box then links to the Pro Series battery bank, creating a flexible networking solution..
Page 3
Features
1. Pro Series Software · Intuitive Interface: The included Pro Series software simplifies system monitoring and configuration through graphical menus.
· Reliable Performance: Optimized for real-time data processing without compromising accuracy or speed.
2. Versatile Connection Options · Direct to Battery: Ideal for single-battery or smaller systems.
· Through the Communication Box: Suited for larger, multi-battery setups or advanced communication protocols.
3. Display · Screen Size and Quality: A 5.0-inch IPS LCD (800×480 resolution, 262K true color) provides crisp, vivid visuals and broad viewing angles.
· Capacitive Touch Panel: Ensures a responsive and user-friendly experience when navigating menus and reviewing data.
4. Built-in Speaker and LED · Audible Alarms: Receive immediate alerts for various warnings or when the SOC dips below specified thresholds.
· Photosensitive Sensor: Automatically adjusts screen brightness based on ambient light, improving visibility and reducing power draw.
5. Robust Construction · Enhanced Durability: Anti-UV and conformal protective coatings help guard against environmental stress.
· IP65 Front Enclosure: Provides dust and water resistance, making the device suitable for both indoor and outdoor scenarios.
Page 4
Dimensions
Page 5
Technical Specifications
Parameter
Specification
Rated Input Voltage
960V
Rated Power
<5W
Maximum Operating Current 170mA (VCC=12V)
Minimum Operating Current 55mA (VCC=12V)
Resolution
800×480
Operating Humidity
10%90%RH
Ingress Protection
IP65 (Front)
Communication Interface RS485
Operating Temperature
20°C to 70°C
Storage Temperature
30°C to 80°C
Net Weight
340 g
Display Type
LCD
Screen Size
5″
Terminal Block
Terminal Label
Description
1
RS485 B RS485 communication (low signal)
2
RS485 A RS485 communication (high signal)
3
CAN L CAN communication (low signal)
4
CAN H CAN communication (high signal)
5
RX
RS232 receive
6
TX
RS232 transmit
7
GND
Negative electrode (power)
8
VIN
Positive electrode (960V)
Page 6
Installation
1. Connect Power and Communication Cables 1. Power Connection
· Ensure correct polarity: positive to positive, negative to negative.
2. Communication Connection · Direct to Battery: Plug the Touch Screen Display’s communication cable into the LINK IN port of the Pro Series master battery. · Using the Communication Box: Connect the Touch Screen Display’s cable to the Tmonitor port on the Communication Box, then verify the Communication Box is wired correctly to the Pro Series batteries.
Best Practice: Double-check all connections for security and correctness before powering on the system to avoid communication issues or potential damage.
2. Enable Communication Networking (with Pro Series Batteries) The Touch Screen Display shows battery data only if the Pro Series battery system is in communication networking mode.
1. Link Battery Modules
· Connect LINK OUT of the first battery to LINK IN of the second battery, and so on.
· Turn on the power switches for every battery.
Page 7
2. Enter Disconnected State
· On the first Pro Series battery’s display panel, press and hold the Config button for 3 seconds.
· All SOC indicators should flash simultaneously. If not, repeat until successful..
3. Enter Communication Network Mode
· (Skip this step for single-battery systems.)
· Again, press and hold the Config button on the first battery for 10 seconds or more.
· The SOC indicators on all batteries will flash alternately for about 23 minutes. When
complete, they revert to normal display. If not, repeat the process.
4. System Configuration (via Bluetooth App)
· Use the Epoch Pro Bluetooth app to create a wired network setup.
· Enter system information: system name and the number of series/parallel connections.
· Assign the first battery as the primary battery so the Touch Screen Display shows
overall system data accurately.
3. Mounting
Page 8
Interface & Navigation
1. Parameter Page Displays the essential battery system parameters:
· SOC (%): Overall State of Charge. When SOC 10%, the on-screen indicator may change color (e.g., from green to yellow).
· Voltage (V): Total battery system voltage.
· Current (A): Real-time current flow (charging or discharging).
· Remaining Capacity (Ah): Calculated capacity available in the battery system.
· Max Temp / Min Temp: Highest and lowest temperatures within the system (°C or °F).
· Configuration: Number of series and parallel connections in the system.
2. Detail Page Allows you to view comprehensive information about a selected battery pack:
· SOC (%), Voltage (V), Current (A), Capacity (Ah), Temperature, Power (W), and Cycles Page 9
3. Setting Page
· Time Setting: Adjust the internal clock for accurate time-stamping of data and alarms. Modify year, month, day, hour, minute, second, then press Confirm to save.
· Language Selection: Toggle between English and Chinese.
· Temperature Unit: Switch the display from °C to °F (or vice versa).
4. Select Protocol Choose the correct communication protocol for your particular inverter or equipment:
Protocol ID Protocol 1
Inverter/Equipment Support Victron / SMA / Studer Innotec / Sofar
Page 10
Protocol ID Protocol 2
Protocol 3 Protocol 4 Protocol 5 Protocol 6 Protocol 11
Others
Inverter/Equipment Support
Sol-Ark / Solis / Goodwe / Deye / Growatt / SAJ / LUXPOWER / Megarevo / INVT / Sermatec / TBB / MUST / SUNGOLDPOWERSG / Sunsynk Schneider
NMEA-2000
CIBUS
RV-C
Voltronic / SUNGOLDPOWERSPH / RCT / MPP / Alpha Outback / Phocos Pending
Warnings & Protections
The system displays messages related to battery health, performance, and safety. If any warning or protection message persists, immediately discontinue use and contact technical support.
Warning
Protection
Cell under voltage warning
Cell under voltage protection
Cell over voltage warning
Cell over voltage protection
Battery under voltage warning
Battery under voltage protection
Battery over voltage warning
Secondary charge over current protection
Charge over current warning
Secondary discharge over current protection
Discharge over current warning
Short circuit protection
Low ambient temperature warning
Cell failure protection
High ambient temperature warning
Charge over current protection
MOS low temperature warning
Discharge over current protection
MOS high temperature warning
Low ambient temperature protection
Cell charge low temperature warning
High ambient temperature protection
Cell charge high temperature warning
MOS low temperature protection
Cell discharge low temperature warning
MOS high temperature protection
Cell discharge high temperature warning
Cell charge low temperature protection
Page 11
Warning Low capacity warning Low insulating resistance warning Cell disconnected warning Cell failure warning Cell heating abnormal warning Cell/System over voltage warning Cell/System under voltage warning Discharge high temperature warning Discharge low temperature warning Charge high temperature warning Charge low temperature warning Internal communication failure warning Cells unbalance warning
Protection Cell charge high temperature protection Cell discharge low temperature protection Cell discharge high temperature protection Low capacity protection Low insulating resistance protection Cell disconnected protection MOS failure protection AFE failure protection Cells voltage difference protection Cell/System over voltage protection Cell/System under voltage protection Discharge high temperature protection Discharge low temperature protection Charge high temperature protection Charge low temperature protection Discharge over current protection Charge over current protection System failure protection Cells unbalance protection
These warnings and protections are designed to prevent permanent damage to the battery system and ensure user safety. Always address any issues before resuming operation.
Support
For further assistance or inquiries not covered in this guide, please visit:
https://www.epochbatteries.com/support
Page 12
Documents / Resources
![]() |
EPOCH BATTERIES Touch Screen Display and Communication Box [pdf] User Guide Touch Screen Display and Communication Box, Screen Display and Communication Box, Display and Communication Box, Communication Box |