FortiSwitch-SASE 124G Series QuickStart Guide
Models: FS-SASE-124G, FS-SASE-124G-FPOE
The Essentials
Secure your Network
Register at https://support.fortinet.com for the latest threat protection updates.
GUI Setup
- Connect Port 1 to an Ethernet port or USB-RJ45 Ethernet adapter on your computer using an Ethernet cable (not included).
- Open a browser to https://192.168.1.99.
CLI Setup
- Connect a console cable (not included) to the Console Port.
- Open a Terminal app using 115200-8-N-1.
Default Logins
- GUI: https://192.168.1.99, Username: admin, Password: leave blank
- FortiCloud: https://fortilan.forticloud.com, Username: user-defined, Password: user-defined
Fortinet Documents Library
For getting started documentation, admin guides, up-to-date hardware manuals, and reference resources, visit https://docs.fortinet.com/.
FortiLAN Cloud
Experience simplified cloud provisioning, zero touch deployment, configuration management, and reporting at https://fortilan.forticloud.com.
FortiSASE Integration
To configure your device as an L3 switch using the SASE WAN Ports, refer to the FortiSASE Admin Guide at https://docs.fortinet.com/product/fortisase.
Package Contents
FortiSwitch-SASE 124G Series (FS-SASE-124G, FS-SASE-124G-FPOE)
- 1x FortiSwitch-SASE Device
- 1x QuickStart Guide
- 4x Rubber Feet
- 1x AC Power Cable
- 2x Rackmount Brackets, 8x Bracket Screws (for FS-SASE-124G)
- 2x Rackmount Brackets, 8x Bracket Screws (for FS-SASE-124G-FPOE)
Setup
GUI
Connection: Port 1 to Ethernet Port (not included) via Ethernet Cable.
IP Address: https://192.168.1.99 (Default). If Static IP: 192.168.1.1/24.
Login: Username: admin, No Password.
CLI
Connection: Console Port via Console Cable (not included).
Terminal Settings: Speed (default): 115200, Data bits: 8, Stop bits: 1, Parity: None, Flow Control: None.
FortiLink
Connection: FortiSwitch Port to FortiGate Port via Ethernet Cable (not included).
- Login to the FortiGate and go to WiFi & Switch Controller > FortiLink Interface.
- Add a FortiGate Port in the FortiLink interface.
- When the device is discovered, select Authorize.
- Optional: To automatically authorize the device upon discovery, enable "Automatically authorize devices" in the FortiLink Interface settings.
FortiLAN Cloud
Connection: FortiSwitch Port to Internet via Ethernet Cable (not included).
- Visit https://support.fortinet.com for registration and cloud management license.
- Sign in at https://fortilan.forticloud.com to manage your Inventory List.
RackMount
- Secure the ears using the provided screws.
- Install in a rack using the provided screws.
FS-SASE-124G
Image description: Front view of the FS-SASE-124G switch with rackmount ears and screws.
Image description: Rear view of the FS-SASE-124G switch mounted in a rack.
FS-SASE-124G-FPOE
Image description: Front view of the FS-SASE-124G-FPOE switch with rackmount ears and screws.
Image description: Rear view of the FS-SASE-124G-FPOE switch mounted in a rack.
Front FS-SASE-124G
1 CONSOLE Port (RJ45)
2 POWER
- Green: Device is on
- Off: Device is off
ALARM
- Amber: Fault detected
- Off: No fault detected
BLE (for future use)
- Blue: BLE on
- Flashing Blue: BLE in discovery
- Off: BLE off
3 RESET Press and hold for 10secs to restore factory default settings.
4 Ports 1 to 24 (RJ45) Ports 23 & 24 are SASE WAN Ports
- Left LED (100M/10M Mbps): Amber: Connected, Flashing Amber: Data activity, Off: Not connected
- Right LED (2.5/1 Gbps): Blue: 2.5 Gbps connected, Flashing Blue: 2.5 Gbps data activity, Green: 1 Gbps connected, Flashing Green: 1 Gbps data activity, Off: Not connected
5 Ports 25 to 28 (SFP+) Ports 25 & 26 are SASE WAN Ports
- Blue: 10 Gbps connected
- Flashing Blue: 10 Gbps data activity
- Green: 1 Gbps/100 Mbps connected
- Flashing Green: 1 Gbps/100 Mbps data activity
- Off: Not connected
6 USB 2.0 Port (USB A) for future use
MGMT (RJ45)
- LINK/ACT (Left LED): Green: Connected, Flashing Green: Data activity, Off: Not connected
- SPEED (Right LED): Green: 1 Gbps, Amber: 100 Mbps, Off: 10 Mbps or not connected
Rear FS-SASE-124G
1 Power Input: 100-240V AC, 1.5A Max, 50/60Hz
Front FS-SASE-124G-FPOE
1 CONSOLE Port (RJ45)
2 POWER
- Green: Device is on
- Off: Device is off
ALARM
- Amber: Fault detected
- Off: No fault detected
BLE (for future use)
- Blue: BLE on
- Flashing Blue: BLE in discovery
- Off: BLE off
PoE MAX (up to ##W)
- Amber: Max PoE power reached
- Off: PoE+ available
3 RESET Press and hold for 10secs to restore factory default settings.
4 Ports 1 to 24 (RJ45) Ports 23 & 24 are SASE WAN Ports
- Left LED (100M/10M Mbps): Amber: Connected, Flashing Amber: Data activity, Off: Not connected
- Left LED (PoE): Amber: Supplying PoE, Off: Not suppling PoE
- Right LED (2.5/1 Gbps): Blue: 2.5 Gbps connected, Flashing Blue: 2.5 Gbps data activity, Green: 1 Gbps connected, Flashing Green: 1 Gbps data activity, Off: Not connected
5 Ports 25 to 28 (SFP+) Ports 25 & 26 are SASE WAN Ports
- Blue: 10 Gbps connected
- Flashing Blue: 10 Gbps data activity
- Green: 1 Gbps/100 Mbps connected
- Flashing Green: 1 Gbps/100 Mbps data activity
- Off: Not connected
6 USB 2.0 Port (USB A) for future use
MGMT (RJ45)
- LINK/ACT (Left LED): Green: Connected, Flashing Green: Data activity, Off: Not connected
- SPEED (Right LED): Green: 1 Gbps, Amber: 100 Mbps, Off: 10 Mbps or not connected
Rear FS-SASE-124G-FPOE
1 Power Input: 100-240V AC, 12A Max, 50/60Hz
Cautions and Warnings
Environmental specifications
- Ambient operating temperature: 0°C to 45°C
- Rack Mount Instructions: Consider ambient temperature and airflow in rack assemblies. Ensure safe operation by not compromising airflow. Avoid hazardous conditions due to uneven mechanical loading. Consider circuit overloading and ensure reliable earthing. Refer to specific Product Model Data Sheet for detailed Environmental Specifications.
Safety
- Battery: Risk of explosion if replaced with an incorrect type. Do not dispose of batteries in fire. Dispose of used batteries according to local regulations.
- CAUTION: Danger of explosion if battery is replaced incorrectly. Replace only with the same or equivalent type. Dispose batteries according to manufacturer's instructions. Avoid conditions that can lead to explosion or leakage (fire, hot oven, crushing, cutting, extreme temperatures, low air pressure).
- WARNUNG (German): Lithium-Batterie Achtung: Explosionsgefahr bei fehlerhafter Batteriewechsel. Ersetzen Sie nur den gleichen oder gleichwertigen Typ. Batterien gemäß den Anweisungen des Herstellers entsorgen. Beseitigung einer BATTERIE in Feuer oder einen heißen Ofen oder mechanisches Zerkleinern oder Schneiden einer BATTERIE, die zu einer EXPLOSION führen kann. Verlassen einer BATTERIE in einer extrem hohen Umgebungstemperatur, die zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder Gas führen kann. Eine BATTERIE, die einem extrem niedrigen Luftdruck ausgesetzt ist, der zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder Gas führen kann.
- 警告 (Chinese): 本電池如果更換不正確會有爆炸的危險. 請依製造商說明書處理用過之電池.
- Caution: This equipment is to be used in a Network Environment 0 per IECTR 62101. This product is connected only to PoE networks without routing to the outside plant.
- Attention (French): Ce matériel doit être utilisé dans un Environnement Réseau 0 par IECTR 62101. Ce produit est uniquement connecté aux réseaux PoE sans installation externe de routage.
- Grounding: To prevent damage, connections entering from outside should pass through a lightning/surge protector and be properly grounded. Use an ESD workstation and/or anti-static wrist strap. The product has a separate protective earthing terminal on the back panel in addition to the plug's grounding terminal. This terminal must be permanently connected to earth with a green/yellow stripe conductor (minimum #14AWG) and installed by qualified personnel.
- Mise à la terre (French): Pour éviter d'endommager votre matériel, assurez-vous que les branchements qui entrent à partir de l'extérieur du bâtiment passent par un parafoudre / parasurtenseur et sont correctement mis à la terre. Utilisez un poste de travail de décharge électrostatique (ESD) et/ou portez un bracelet anti-statique lorsque vous travaillez. Ce produit possède une borne de mise à la terre qui est prévu à l'arrière du produit, à ceci s'ajoute la mise à la terre de la prise. Cette borne de mise à la terre séparée doit être connecté en permanence à la terre avec un conducteur vert avec la taille bande jaune de minimum # 14AWG et la connexion doit être installé par un personnel qualifié.
Regulatory Notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
WARNING: Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Innovation, Science and Economic Development (ISED) – Canada
CAN ICES-003 (A) / NMB-003 (A)
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Cet appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicte par le ministère des Communications du Canada.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20cm de distance entre la source de rayonnement et votre corps.
This radio transmitter (IC: 7280B-240701) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (IC: 7280B-240701) a été approuvé par ISED pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
This device and its antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC multi-transmitter product procedures.
Cet appareil et son antenne (s) ne doit pas être co-localisés ou fonctionnement en association avec une autre antenne ou transmetteur.
Antenna No. | Antenna Type | Antenna Peak Gain |
---|---|---|
1 | Network FPC | 2.0 dBi |
Bluetooth |
European Conformity (CE) - EU
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
The product transmits within the frequency ranges and less than or equal to the power listed below: 2402-2480MHz less than 20dBm.
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products provided by Fortinet or Fortinet's authorized partners to the end customer directly for use within the EU or countries that have implemented the EU Directives and/or spectrum regulation. Any Fortinet products not obtained directly from Fortinet or Fortinet's authorized partners may not comply with EU Directives and Fortinet makes no assurances for such products.
Български: Този продукт е в съответствие с Директива 2014/53/EC.
Česky: Tento produkt je v souladu se směrnicí 2014/53/EU.
Dansk: Dette produkt er i overensstemmelse med direktiv 2014/53/EU.
Deutsch: Dieses Produkt entspricht der Richtlinie 2014/53/EU.
Eesti: See toode vastab direktiivile 2014/53/EL.
English: This product is in compliance with Directive 2014/53/EU.
Español: Este producto cumple con la Directiva 2014/53/UE.
Ελληνική: Το προϊόν αυτό συμμορφώνεται με την Οδηγία 2014/53/ΕΕ.
Français: Ce produit est conforme à la Directive 2014/53/UE.
Hrvatski: Ovaj proizvod je u skladu s Direktivom 2014/53/EU.
Italiano: Questo prodotto è conforme alla Direttiva 2014/53/EU.
Latviski: Šis produkts atbilst Direktīvai 2014/53/EU.
Lietuvių: Šis gaminys atitinka direktyvą 2014/53/ES.
Malti: Dan il-prodott huwa konformi mad-Direttiva 2014/53/UE.
Magyar: Ez za termék megfelel a 2014/53/EU irányelvnek.
Nederlands: Dit product is in overeenstemming met Richtlijn 2014/53/EU.
Norsk: Dette produktet er i samsvar med direktiv 2014/53/EU.
Polski: Ten produkt jest zgodny z dyrektywą 2014/53/UE.
Português: Este produto está em conformidade com a Diretiva 2014/53/UE.
Rumunski: Acest produs este în conformitate cu Directiva 2014/53/UE.
Slovensky: Tento produkt je v súlade so smernicou 2014/53/EÚ.
Slovensko: Ta izdelek je v skladu z Direktivo 2014/53/EU.
Suomi: Tämä tuote on direktiivin 2014/53/EU mukainen.
Svenska: Denna produkt överensstämmer med direktiv 2014/53/EU.
Note: The full declaration of conformity for this product is available at the link: https://site.fortinet.com/ProductRegulatory/EU
UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to the power listed below: 2402-2480MHz less than 20dBm.
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
This product is in compliance with Statutory Instrument 1206 Radio Equipment Regulations 2017.
The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/UK
Voluntary Control Council for Interference (VCCI) – Japan
この装置は、クラスA機器です。この装置を住宅環境で使用すると電波妨害を引き起こすことがあります。この場合には使用者が適切な対策を講ずるよう要求されることがあります。 VCCI-A
Product Safety Electrical Appliance & Material (PSE) – Japan
日本では電気用品安全法(PSE)の規定により、同梱している電源コードは本製品の専用電源コードとして利用し、他の製品に使用しないでください。
Bureau of Standards Metrology and Inspection (BSMI) – Taiwan
The presence conditions of the restricted substance (BSMI RoHS table) are available at the link below: https://www.fortinet.com/bsmi
警告: 為避免電磁干擾,本產品不應安裝或使用於住宅環境。
請仔細閱讀以下說明
- 本設備勿置於潮濕處。
- 連接至電源前,請先檢查電壓。
- 當設備不用時,請將所有電源線拔除,避免電壓不穩而造成傷害。
- 勿將任何液體濺入設備中,避免線路短路。
- 基於安全理由,只有受到專業訓練的從業人員,才可以打開本設備。
- 請勿自行調整或修理已通電的設備,以確保您的安全。
- 如不小心受傷,請立刻找急救人員給予您適當的救護,千萬別因傷勢輕微而忽略自己的傷勢。
- 請依照台灣法規處置電池。
- 若不正確替換電池可能導致爆炸危險,替換電池時,請使用設備生產商推薦使用的電池。
- 請勿拆卸、刺穿或以其他方式損壞電池。
- 雷射設備非用戶維修設備,請與生產商聯繫維修事宜。
英屬蓋曼群島商防特網股份有限公司台灣分公司 地址:台北市內湖區行愛路176號2樓 電話:(02)27961666
National Telecommunications Commission (NCC) – Taiwan
NCC警語 取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前述合法通信,指依電信管理法規定作業之無線電通信。低功率射頻器材須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。
China
警告:在居住环境中,运行此设备可能会造成无线电干扰。