ENTTEC 73539 DIN PIXIE
Product Information
Specifications:
- Custom Protocol Creation Guide
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
Product Usage Instructions
Introduction:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
Setup Requirements:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
COMPATIBLE FIRMWARE
Custom protocol creation is featured in the following ENTTEC pixel controllers:
| SKU | Product | Firmware Version |
| 73539 | DIN PIXIE | V2.0 or above |
| 70067 | PIXELATOR MINI | V2.0 or above |
| 70068 | PIXELATOR MINI MK2 | V1.0 or above |
| 71521 | OCTO MK2 | V4.0 or above |
| 71522 | OCTO MK3 | V1.0 or above |
INTRODUCTION
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- This feature enables users to adjust the voltage timing based on the supported protocols if the data transmission method matches any of our supported protocols.
- This document provides setup instructions for creating a custom pixel protocol and verifying the criteria.
SETUP REQUIREMENTS
The following are required to create a custom protocol:
- Datasheet: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- Device: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
GUIDE TO CUSTOM PROTOCOL CREATION
This feature allows users to adjust the data voltage timing to meet specific protocol needs. To create a custom protocol:
- Verify the datasheet for the compatible pixel protocol.
- Navigate to the Device’s User Interface to enable the custom protocol feature.
- Adjust the pixel fixture’s data voltage timing via the web interface as per the manufacturer’s datasheet.
Step 1: Verify the datasheet for the compatible protocol
- Verify the data transmission method of your desired protocol from the datasheet.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- The most common method transmits data without additional bits (e.g., D1-D2-D3…Dn).
Example: Information captured from WB2812B’s datasheet
- Some protocols, like TM1814, include additional data at the front (e.g., C1-C2-D1-D2…Dn).
Example: Information captured from TM1814’s datasheet
- The most common method transmits data without additional bits (e.g., D1-D2-D3…Dn).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Nominate the matching protocol supported by the device (or choose from the above example) that shares the same data transmission method as your desired pixel protocol.
- Proceed to Step 2 for further configuration.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web interface
- Google Chrome is suggested as the web browser to access the OCTO/PIXELATOR MINI’s web interface.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC website www.enttec.com to download the app.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
Go to the output where the desired pixel fixture is connected to. Pick a pixel protocol from the dropdown list that shares the same transmission method verified in Step 1.
- Enable Custom protocol (Continue to Step 3)
Enable the ‘Custom’ tick box to access the data voltage timing setup. Untick to disable the custom protocol.
For DIN PIXIE
- Connect DIN PIXIE to a computer using USB Type-B.
- Launch EMU Software.
- Scan for the device and click on the Conf of the discovered DIN PIXIE.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
Step 3: Set custom voltage timing
- Match the voltage timing on the datasheet of your desired protocol. Custom Protocol requires 4 inputs to complete data voltage timing adjustment:
Voltage Timing Definition Bit 0 High Time (T0H) The voltage high time required for code 0. Bit 1 High Time (T1H) The voltage high time required for code 1. Overall Bit Time: The total voltage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
Reset Time The total voltage low time required to reset the data transmission between each data batch. 
- Datasheet – Data voltage timing info Example
From WB2818B’s datasheet- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage timing range.
- Fill the voltage timing range in the custom field in Output Settings.

IMPORTANT
- ENTTEC recommends taking the median value of the range for the start.
- The user will have to SAVE settings for the modified value to take effect.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
CONCLUSION
- This guide demonstrated how to set up a custom protocol for eligible ENTTEC devices and provided technical knowledge on verifying the datasheet of your desired pixel fixtures.
- By following these steps, users can create a custom pixel protocol not found in the drop-down list without waiting for technical support or a new firmware release. If you have questions or difficulty finding the right information, reach out to our friendly support team at the local offices.