CMe3100 M-Bus Metering Gateway for Fixed Network

elvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-PRODUCT

Specifications:

  • Model: CMe3100 (Gen 2)
  • Type: M-Bus Metering Gateway for Fixed Network
  • Power Supply: 100-240 VAC, 50/60 Hz
  • Network Connectivity: Ethernet (RJ45) and USB
  • Wireless M-Bus Support: Yes
  • Mounting: DIN-rail

Product Usage Instructions:

Wireless M-Bus:

  • CMe3100 supports reading wireless M-Bus meters via Elvaco’s wireless M-Bus Receivers. Connect the M-Bus Receiver to the M-Bus master port (13) or use IR communication.

M-Bus Slave Ports:

  • Use the two M-Bus slave ports to share meter data with other M-Bus systems. Configure each port individually through the web interface.

Ethernet Connection:

  • Connect a Cat 5e or better TP cable to the Ethernet connection (9). The Yellow LAN LED (6) indicates successful connection. Red ERR LED flashes if an IP address is assigned.

IR Interface:

  • Use the IR interface for communication with specific devices.
  • Remove the IR shield (14) and mount CMe3100 close to the device for  IR communication

Getting Started via USB Slave Port:

  • Login: Set a new password on first login meeting specified criteria.
  • Mounting: Attach CMe3100 to a DIN-rail ensuring terminals are covered for safety.
  • Power Supply: Install with a 10 A circuit breaker or slow blow fuse. Connect main supply to screw terminals (1) and (2).

M-Bus Master:

  • If password is forgotten, reset to factory settings to regain access.

Factory Reset:

  • To reset to factory default settings, use the web interface or hold the push button (15) during startup until LEDs flash alternately.

LED Indications:

  • Green LED: Off (Lacks power or boot mode), 50/50 (Booting), Long flash (Normal operation), On (Error)
  • Red LED: On (Short circuit), 50/50 (Network problems or booting), Off (Normal operation)
  • Yellow LED: On (Flash), Off (Normal), Flashing (Indicates activity)

INTRODUCTION

  • CMe3100 is an M-Bus Metering Gateway for Fixed Network with logging functionality. It can read and interpret meter data from all ABB DIN-mounted electricity meters with IR interface and any M-Bus meter following the M-Bus standard protocol. Meter data can be downloaded or sent through a variety of formats and protocols, such as MQTT, HTTP, FTP, e-mail, Modbus, M-Bus slave port, M-Bus over TCP/IP and the REST-protocol. For a complete description of the product or for information in Swedish, visit the Elvaco AB website, www.elvaco.com.

OVERVIEW

elvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (1)

  1. Power supply L
  2. Power supply N
  3. Green PWR LED
  4. Red ERR LED
  5. Serial number
  6. Yellow LAN LED
  7. Blue LED
  8. USB master
  9. Ethernet connection
  10. USB slave
  11. M-Bus slave 1
  12. M-Bus slave 2
  13. M-Bus master port
  14. IR interface
  15. Push button

MOUNTING

  • The CMe3100 is mounted on a DIN-rail. The plastic clip on the bottom is used to attach and deattach the unit. For safety reasons, a DIN-rail enclosure must cover the terminals.

Using Instruction

POWER SUPPLY

  • The installation should be performed by a qualified electrician or an installer with the required knowledge.
  • The power supply must be protected with a 10 A circuit breaker of characteristic C or slow blow fuse and connected via a clearly marked, easily accessible switch so the unit can be switched off during service work.
  • Main supply should be connected to screw terminal (1) and (2). Main supply voltage should be in the range of 100-240 VAC, 50/60 Hz.

M-BUS MASTER

  • M-Bus is a multi-drop 2-wire bus with no polarity. CMe3100 is equipped with an M-Bus master for 32 slaves (32 M-Bus loads , 48 mA). Overloading the bus will turn the ERR LED (4 ) on and turn off the M-Bus bus.
  • If you wish to connect more than 32 slave devices, mount an M-Bus Master from the CMeX Series on the right side of the CMe3100 to expand the capacity.
  • All connected M-Bus slaves must have unique primary or secondary M-Bus addresses depending on addressing mode.
  • Use a cable of area 0.25-1.5 mm2, e.g. a standard telephone cable (EKKX 2x2x0.5), connect the wiring to the M-Bus master port (13). Do not exceed the maximum cable length of 1000 m.

WIRELESS M-BUS

  • CMe3100 supports reading of wireless M-Bus meters via an Elvaco’s wireless M-Bus Receivers. The M-Bus Receiver is connected to
    the M-Bus master port (13) or placed right next to the CMe3100 to communuicate by IR. Elvaco’s wireless M-Bus system is automatically configured and wireless meters can be read directly.

M-BUS SLAVE PORTS

  • CMe3100 is equipped with two M-Bus slave ports used to share meter data with other M-Bus systems. The ports can be configured individually in the web interface. Connect the master device to M-Bus slave port 1 (11) or M-Bus slave port 2 (12).

ETHERNET CONNECTION

  • Connect a TP cable of type Cat 5e or better to the Ethernet connection (9), RJ45. On successful connection to the switch/hub, the Yellow LAN LED (6) will be permanently on or flashing. If CMe3100 has or will be assigned an IP
    address, the Red ERR LED will flash 50/50.

IR INTERFACE

  • The IR interface can be used for communication with an ABB electricity meter or a CMeX module. Remove the IR shield (14), mount CMe3100 on the left side of the other device and leave no space between the products. Do not remove the IR shield unless the IR interface is used.

GETTING STARTED VIA USB SLAVE PORT

  • The CMe3100 is configured via the integrated web interface. This is easily reached via the local USB slave port (10) that is connected to a PC. Connect the included USB cable between the computer and USB slave port. After approximately 30 seconds, a removable disk will be available on the computer. Open the folder on the removable disk and run the file CMe3100-SETUP.EXE and follow the instructions. When the installation has completed, a browser with the IP address 169.254.254.1 will open.
  • (For software versions older than 1.6.0, the IP address 192.168.100.1 will be used.)
  • It is also possible to log in via the network that the product is connected to. In this case, a DHCP server is needed in the network or that CMe3100 has a static IP address configured. Find out which IP address CMe3100 uses and enter it in a browser.

LOGIN

  • At the first login, the user is required to set a new password. The password must be at least 12 characters long and include at least one special character, one number, and both uppercase and lowercase letters.
  • Note: If the password is forgotten, the device must be restored to factory settings to regain access.

WIRING DIAGRAM

elvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (2)

FACTORY RESET

  • CMe3100 can be reset to factory default settings by using the web interface. It can also be done by holding the push button (15) pressed down on the device during startup until the green and red LEDs are flashing alternately (release of the button starts the factory reset).

LED INDICATIONS

  • Green LED

elvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (3)

  • Red LEDelvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (4)
  • Yellow LEDelvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (5)
  • Blue LED – Not used

TECHNICAL SPECIFICATIONS

  • Mechanicselvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (6)
  • Electrical connectionselvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (7)
  • Electrical characteristicselvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (8)
  • User interfaceelvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (9)
  • Integrated M-Bus Masterelvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (10)
  • M-Bus slave interfaceelvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (11)
  • Approvalselvaco-CMe3100-M-Bus-Metering-Gateway-for-Fixed-Network-FIG- (12)

TROUBLESHOOTING

  • All LEDs are permanently off
  • Verify that the product is powered up. If the product is in the first stage of the start-up process, wait approximately 20 s.

Red LED is permanently on

  • Verify no short-circuit of the M-Bus bus by measuring the voltage over the M-Bus master. The voltage should be between 24-30 VDC.

Red LED is flashing, the unit can not be accessed via LAN

  • Is the CMe3100 configured with static IP or dynamic IP (dynamic IP is set as default). If static IP assignment is used, make sure that there are no IP conflicts.
  • For dynamic IP, check that the CMe3100 is connected to a network with a correctly working DHCP server.

SIMPLIFIED DECLARATION OF CONFORMITY 

  • Hereby, Elvaco declares that the product is in compliance with the following directives:
  • EU:
    • 2014/30/EU (EMC)
    • 2014/35/EU (LVD)
    • 2011/65/EU + 2015/863 (RoHS) UK:
    • 2016 No. 1091
    • 2016 No. 1101
    • 2012 No. 3032
  • North America:
    • FCC 47 CFR Part 15 Subpart B
    • ICES-001 Issue 4
    • CB certificate No. SE-103859
    • ETL No:5017602

CONTACT INFORMATION

Frequently Asked Questions

Q: What is the default password for CMe3100?

A: The default password is not set. Upon first login, you must set a new password meeting specified criteria.

Q: How do I reset CMe3100 to factory settings?

A: You can reset CMe3100 to factory default settings using the web interface or by holding down the push button during startup until LEDs flash alternately.

Q: What is the range of the main power supply voltage for CMe3100?

A: The main supply voltage should be in the range of 100-240 VAC, 50/60 Hz.