iS1500LV Sliding Gate Motor Kit with Battery Backup
“
Specifications:
- Model: iS1500LV
- Motor Voltage: 24 Volts DC motor
- Max Absorbed Power: 250 Watts
- Power Supply: 240 Volts AC
- Maximum Gate Weight: 45Kg
- Duty Cycle: Operating Temperature
- Operating Temperature: Not specified
- Motor Kit Weight: Not specified
Product Usage Instructions:
Safety Instructions:
Ensure all safety guidelines are followed to prevent injury or
damage to property.
Electrical Cabling:
Follow the electrical cabling instructions provided in the
manual for proper installation.
Mechanical Installation:
Properly install the gate opener and fix the rack to the gate
frame with the specified clearance.
Electrical Connections:
Connect the control card following the instructions provided.
Adjust limit switches and power on the control card to profile the
gate.
Quick Start Instructions:
- Place operator in correct position and fix it to the concrete
pad. - Fix rack to the gate frame with clearance between rack teeth
and Pinion wheel. - Check movement of the rack over the pinion wheel, adjust if
needed. - Install stops on the gate for fully closed and open
positions. - Connect all safety devices including Photo Electric Beams and
Safety Bump Strip.
FAQ:
Q: What should I do if the gate opener stops working?
A: Check the power supply, ensure proper electrical connections,
and refer to the troubleshooting section in the manual.
Q: How often should I perform maintenance on the gate
opener?
A: Regular maintenance is recommended to ensure smooth
operation. Follow the maintenance procedures outlined in the
manual.
“`
HIGH SPEED SLIDING GATE OPENER WITH BATTERY BACK-UP
Model: iS1500LV
Elsema’s Eclipse® Control Card
USER MANUAL Scan the QR code for more details
Safety Instructions
Save these instructions for future reference.
WARNING! FAILURE TO FOLLOW THESE SAFETY AND INSTALLATION INSTRUCTIONS
COULD RESULT IN INJURY OR DEATH AND/OR DAMAGE TO PROPERTY AND EQUIPMENT.
· Appropriately licensed and competent personnel only should install the automation equipment. · The operators are designed specifically to open and close sliding gates or doors and should not be used for any
other purpose. · The gate can operate unexpectedly, so ensure nothing remains in its path.
· Do not operate the gate unless the user has a full view of the gate and there are no objects, person/children in
the gate operation area.
· Do not let children play with the transmitters or any other gate control system. · Do not disengage the gate opener to manual when there are children, people, objects, or vehicles within the
gate’s operation area. Manual release may cause uncontrolled movement.
Always incorporate the appropriate Photo Electric Beams, Safety Bump Strip, Induction Loops and other safety devices to protect both equipment and personnel. Photoelectric Beam must be installed and operational.
· Display all necessary signs to indicate any danger areas and automatic operation of the gate or door. · The operators are not designed to be used in any hazardous areas or areas subject to flooding etc. · All electrical connections and wiring must be performed with AS/NZS 3000-2018 as the guidelines. · The manufacturer of the automation equipment is not responsible for the damage which may be caused to either
the operator, gate or door and any other person or equipment when: o Wrong or poor installation practices were performed. o No or inadequate safety devices were used. o Poor maintenance on the equipment. o Any other circumstances beyond the manufacturers control. o Automated gates must comply to AS/NZS 60335.1 in conjunction with AS/NZS 60335.2.103.
WARNING! ELECTRICITY CAN KILL
· Isolate power before attempting any maintenance.
· Only qualified personnel should carry out maintenance.
· The installer should provide all information concerning the use of the automation equipment as well as
instructions regarding the manual override and maintenance procedures to the users of the system.
· Keep loose clothing and hands away from the gate whilst its being operated or could possibly be operated!
· Inspect the gate or door, along with its supporting posts and walls, to guard against potential shearing,
compression, and other hazards that could lead to severe injuries or fatalities.
· Check the gateposts or mounting structure has the necessary strength and rigidity to support the operator and the load of the opening and closing gate motion.
Battery warning!
The product comes with wireless transmitters equipped with coin/button cell batteries, which are hazardous. Ensure these devices and their batteries are kept out of reach of children. If the battery is swallowed, it can cause severe internal burns and can lead to death in as little as 2 hours. Always secure the battery compartment. If you suspect that battery has been swallowed or inserted into any part of the body, SEEK MEDICAL HELP IMMEDIATELY.
2
Technical Features
Motor Voltage Max Absorbed Power Power Supply Nominal Input Current Motor Speed Maximum Gate Weight Duty Cycle Operating Temperature Motor Kit Weight
iS1500LV 24 Volts DC motor
250 Watts 240 Volts AC
10 Amps 367 mm/sec Up to 1,200kg on level ground 80% over 12 min -20°c – +50°c
45Kg
Wiring Requirements
· Single phase 240 Volts 10 Amps non-earth leakage protected power supply to where operator is mounted.
· Low Voltage cables from operator for access control. (Shielded cable if over 8m runs).
Installation Details
After reading the previous sections in this manual, and having checked for suitable installation, proceed as follows:-
Electrical Cabling
· A suitably rated Isolator and 240 Volts power supply should be available near to where the gate operator is to be mounted. The following diagrams will provide measurements for the positioning of conduits and the appropriate position for mounting the operator.
· When bringing power and control cables into the control enclosure inside the operator, please leave enough slack in the cables, in this way, the enclosure can still be lifted in order to see and work on the controls easier. To lift up control enclosure, undo wing nut on right hand side, once lifted up, re tighten the nut to keep enclosure in upwards position, once finished, undo nut, drop enclosure back down, then re tighten wing nut.
3
Mechanical Installation
· Ensure gate rolls easily and has been installed in a manner where there is no excessive friction or binding occurring.
· A concrete base approximately 600mm long x 300 wide x 300mm deep should be laid where the gate operator is to be located.
· IMPORTANT ensure there are gate stops firmly installed in the fully open and closed positions. These stops need to be engineered and installed such that they will be strong enough to stop the gate should the limits fail at any time.
· Remove the gate operator cover and position mounting plate and operator in approximate mounting location.
· Use the rack to locate the operator the correct distance away from the gate rail (finer adjustment can be made after).
· Dynabolt or chemical anchor the bottom mounting plate to the concrete mounting pad using 12 x 100mm fixings.
· Unscrew anticlockwise the manual release knob so the drive gear free wheels. · Fix the rack to the gate rail ensuring there is approximately 1mm – 2mm gap between the meshing of
the teeth of the rack and the drive gear (no more). Move the gate by hand from one end to the other while checking that the rack is meshing correctly with the drive gear on the operator. Check also that the rack is centred around the middle of the teeth on the drive cog tighten the mounting plate nuts.
Electrical Connections
· Connect a non earth leakage protected 10 Amps 240 Volts supply to Din Rail terminals labelled Active, Neutral & Earth.
· Conduits for power & control need to preferably come up through the base plate ‘knockout’.
Control card instructions
Once the limit switches are adjusted turn the power on to the MCSv2 control card and follow on screen instructions to profile the gate. For replacements please contact Elsema.
Scan the below QR code for control card instructions.
4
Plan View Layout / Conduit Position
Quick Start Instructions
1. Place operator in correct position (Pinion wheel to be parallel to the gate and stepped out to allow for width of rack once it is mounted onto the gate frame). Mark out fixings and fix operator to the concrete pad.
2. Fix rack to the gate frame keeping 1mm-2mm clearance between the rack teeth and Pinion wheel.
3. Once the rack is fixed move the gate and sight the rack moving over the pinion wheel, check that most of the pinion wheel meshes with the rack. Make sure rack runs freely over the pinion wheel, any tights spots should be corrected by adjusting the rack height. Check the operator is firmly bolted down to the concrete pad.
4. Ensure stops are installed on the gate for the fully closed and fully open positions. 5. Connect Photo Electric Beams, Safety Bump Strip and all other safety devices as
required. 5
Limit Switch Adjustment
The limit sensor has a + marking indicating the centre of the sensor. Adjust the sensor so that the + marking is in the centre of the magnet on the gear rack.
The 2 x limit magnets should have different marking on them. One should have a and the other should have a . You cannot use the limit magnets if they have the same marking. The magnets can be installed on either side (open or close). Please see the diagram below to locate the marking on the magnets.
Polarity Marking
When steel gear rack is used (or gear rack which are much slimmer), you will have to use the packing block which comes with the limit switches. Please see the diagram below.
6
Once the limit switches are adjusted turn the power on to the MCSv2 control card and follow on screen instructions to profile the gate. The MCSv2 control card has been specially configured to be used with iS motor kit. For replacements please contact Elsema.
Control Inputs
Push button
: N/O input acts as a OSC (open, stop, close) input.
Open
: N/O input acts as a open only (swipe mode) input.
Close
: N/O input close only input (force close) input.
Ped Access
: Used for initiating a partial opening.
Photo Beam (P.E) : N/C safety input. Can be set for N/O operation if needed through menu 3.1.
PE beam operation modes can be changed through menu 4.2.
Control Outputs
12VDC
24VDC devices
Output 1
Output 2
: Supplies regulated 12VDC at a max of 250mA, can be used for accessories such as pe cells warning devices etc, but must not exceed 250mA. : Supplies 24VDC 1.0A regulated output, this can be used for higher power usage
such as induction loops. This output is fused at 1.0 A. : N/O dry contact relay output. Do not exceed 5A load. Can be set for various functions
through menu 5.1 default is Lock/Brake. : Open Collector output. Can be used with Elsema’s REL 1-12 relay card.
CONTROL BOARD LAYOUT
7
Manual Release Instructions
Place key in door lock, turn clockwise till released and pull door open.
Turn knob anticlockwise approx. ½ a turn to release
Gate can now be opened by hand.
To re-engage the clutch, move the gate by hand into approx. the halfway position and turn the knob clockwise until it is very tight. If, when turning the knob clockwise and it just spins, either, try spinning it clockwise with more force to release it off the hexagonal retaining nut or hold the nut with one hand and turn the knob clockwise.
8
Maintenance Details
WARNING!
Failure to maintain equipment may result in injury or death and/or damage to property and equipment.
If the product is not used and maintained in accordance with instructions or recommendations listed in this User Manual, the warranty is negated.
Recommended maintenance to be performed on the operator and gate are as follows:-
Operator performs over 150 cycles a day
every 2 month
Operator performs between 20-150 cycles a day every 6 months
Operator performs under 20 cycles a day
every 12 months
Date: ……………………………………………………………………
Site Name: ………………………………………………………………………………………………………………….
Site Address:……………………………………………………………………………………………………………….
Before commencing maintenance on the operator, isolate the electrical supply to ensure operator will not run inadvertently.
Gate rolls freely when in manual ……………………………………………………………………… Gate wheels and guide rollers in good condition ………………………………………………… Gate stops are installed and in good condition, not loose …………………………………….. Gate rack is tight & correct clearances between pinion wheel & rack …………………….. Gate track is not damaged ……………………………………………………………………………… Gate operator mounting bolts tight …………………………………………………………………… No oil leaks from gearboxes ……………………………………………………………………………. Gearbox mounting bolts/nuts tight ……………………………………………………………………. Inside operator and control box clean……………………………………………………………….. Outdoor Insect Surface Spray around operator and control box (not on electronics) … All electrical connections tight………………………………………………………………………….. Limit Switches operate in appropriate positions ………………………………………………….. External safety devices work effectively / cleaned ………………………………………………. Electromagnetic lock, if fitted, operates correctly and is clean ………………………………. Wash down of control box and cover (particularly near corrosive/sea environments) .. General operation i.e. speed, auto close etc normal ……………………………………………. Comments…………………………………………………………………………………………………………………………… …………………………………………………………………………………………………………………………………… ….
……………………………………………………………………………………………………………………………………………
Service performed by: ……………………………………………………………………………………………………………………………….
Documents / Resources
![]() |
ELSEMA INTELLIGENT SLIDER iS1500LV Sliding Gate Motor Kit with Battery Backup [pdf] Instruction Manual iS1500LV, iS1500LV Sliding Gate Motor Kit with Battery Backup, Sliding Gate Motor Kit with Battery Backup, Gate Motor Kit with Battery Backup, Motor Kit with Battery Backup, Battery Backup |