ELKO EKO60000 Timer Socket Instruction Manual

ELKO-LOGO

ELKO EKO60000 Timer Socket

ELKO-EKO60000-Timer-Socket-PRODUCT

MODELS

EKO60000
EKO60001
EKO30437
EKO50111
EKO50112

Necessary accessories

Insert without frame can be completed with: Frame in the corresponding design and colour.

PKR66748-03 07/25

ELKO-EKO60000-Timer-Socket-FIG-1

Timer socket outlet

With the Timer socket-outlet, you can switch on attached loads (e.g. coffee machines, irons, etc.) for a preset time period using the installed push-button (A).

The timer socket-outlet has six selectable time delays (15 min, 30 min, 1 h, 2 h, 4 h, 8 h). After the set time has elapsed, the timer socket-outlet switches off again automatically. The timer socket-outlet can be switched off by pushing the button again before the time has elapsed. The power status of the socket-outlet is shown with the LED (B).

ELKO-EKO60000-Timer-Socket-FIG-2

  • Green LED: Socket outlet switched on
  • LED off: Socket outlet switched off

Check the time delay
Press the button 3 times short (<0.5 s) to find out the current time delay. The status LED shows the actual setting.

ELKO-EKO60000-Timer-Socket-FIG-3

Connection

ELKO-EKO60000-Timer-Socket-FIG-4 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

Safe electrical installation must be carried out only by skilled professionals. Skilled professionals must prove profound knowledge in the following areas:

  • Connecting to installation networks.
  • Connecting several electrical devices.
  • Laying electric cables.
  • Safety standards, local wiring rules and regulations.

Failure to follow these instructions will result in death or serious injury.

The socket outlet is part of the building installation. The relevant standards and directives of the country must be observed during planning and construction. The operation of the device is permissible only on the 230V / 50 Hz alternating current network.

The installation may only be carried out in commercially available flush-mounted wall-boxes (installation boxes), with a minimum depth of 40mm, in accordance with EN 60670-1.

Mounting

ELKO-EKO60000-Timer-Socket-FIG-5

Connecting

ELKO-EKO60000-Timer-Socket-FIG-6

Note: Do not mix different load types in the controlled socket.

  • Do not use multiple sockets in the controlled socket.
  • Do not use for EV charging

ELKO-EKO60000-Timer-Socket-FIG-4 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

The socket is 1-pole switched. Depending on the installa-tion, voltage may be present at the other contact.
Failure to follow these instructions will result in death or serious injury.

Set up time delay
To enter the timer setup mode, press and hold the push button (A) for more than 5 seconds until the LED (B) lights up green. Place your finger so that you can see the LED.

ELKO-EKO60000-Timer-Socket-FIG-7

As soon as the device switches to setup mode, the LED (B) lights up green. When the button is released, the LED goes out. The LED flashes according to the current delay time (in the default factory setting 2 times for 30 minutes).

Note: In case the socket is switched on when entering setup mode, it will switch off automatically after pressing for 5 seconds.

The delay time is set according to the number of short presses of the button (A). The LED (B) flashes accordingly.

ELKO-EKO60000-Timer-Socket-FIG-8

Save the delay time

To save the selected delay time, press and hold the button (A) for 5 seconds. The LED (B) lights up green. When the button is released, the LED goes out. The LED flashes according to the current delay time.

ELKO-EKO60000-Timer-Socket-FIG-9

After 30 seconds without pressing the button, the device automatically exits the setup mode and the current delay time is not saved. The LED (B) blinks fast.

Device Protection

Note: The device is equipped with temperature and overload protection. When the device is used with a high load over a long time, the protection can switch the socket off. In this case, the LED (B) blinks fast in red. After the device has cooled down, it is possible to switch back to normal mode. To clear the alarm, press and hold the push button for 5 seconds. After 5 seconds, the blinking will stop and the alarm will be cleared. You can use the socket outlet again.

Technical data

ELKO-EKO60000-Timer-Socket-FIG-10

ELKO-EKO60000-Timer-Socket-FIG-11 Dispose of the device separately from household waste at an official collection point. Professional recycling protects people and the environment against potential negative effects.

Schneider Electric Industries SAS 35, rue Joseph Monier
FR – 92500 Rueil-Malmaison
elko.no/contact

PKR66748-03 07/25

Documents / Resources

PDF thumbnailEKO60000 Timer Socket
Instruction Manual · EKO60000, EKO60001, EKO30437, EKO50111, EKO50112, EKO60000 Timer Socket, EKO60000, Timer Socket, Socket

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.