Product Usage Instructions
- Ensure the supply voltage is 230 V AC.
- Connect the device to a power source with a frequency of 50-60 Hz.
- Check the apparent and dissipated power values to ensure proper functioning.
- Verify that the supply voltage tolerance is within the specified range.
- Understand the number of contacts and their rated current for appropriate usage.
- Ensure the switching power does not exceed the specified limits.
- Consider the mechanical and electrical life of the product for longevity.
- Familiarize yourself with the application and communication protocols for effective control.
- Determine the signal transmission method and frequency for proper operation.
Additional Information
- Operate the device within the specified operating temperature and position.
- Mount the product securely according to the provided guidelines.
- Take precautions based on the protection degree and overvoltage category.
- Select appropriate cable sizes for connection to ensure safety and performance.
FAQ
- Q: What is the maximum cable size allowed for connection?
- A: The maximum cable size for connection is not specified in the provided information. It is recommended to consult the manufacturer for details.
- Q: What is the electrical life of the product?
- A: The electrical life of the product under AC1 conditions is not specified. For precise information, please refer to the manufacturer’s documentation.
- Q: Can the device be operated manually?
- A: The manual control functionality is available for this device. Please follow the manual instructions for manual operation.
Connection
To assign an element to the MATTER ecosystem, scan the QR code.
- PROG button, status indication, and output control
- Terminals for external buttons/switches
- Neutral conductor
- Relay output contacts
- Phase conductor
Pairing mode
- Press the PROG button once
- Red LED fl ashes
Restore factory settings
- Hold PROG button >10s
Characteristics
- The switching element with two output relays can be used to control some appliances and lights.
- The Thread protocol guarantees compatibility with other products with the Matter support.
- The wireless controllers (RFGB-40/ MT) and also the existing wired switches/ pushbuttons can be used for control.
- The BOX-SL design offers installation directly in the junction box, soffit or cover of the controlled appliance. Easy connection of wires thanks to the screw-free terminals.
- The applicable reach is up to 200m (in free area).
- The maximum switched power is 2000W (8A), and the relay contact material AgSnO2 + Zero Cross predestines it for switching of lighting loads.
- The reset push button on the element can also be used as manual control of the input.
- The element with the controller can be paired through a border router supporting Matter and through an application supporting Matter. The border router is understood as equipment such as HomePod Mini, Google Nest Hub or Samsung SmartThings Station.
Technical parameters
Warning
The instruction manual is designated for mounting and also for the user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualifications upon understanding this instruction manual and the functions of the device, and while observing all valid regulations.
The trouble-free function of the device also depends on transportation, storage, and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives, and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to the transmissivity of the RF signal, observe the correct location of RF components in the building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation in exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – the radiofrequency signal can be shielded by an obstruction, interfered with, a battery of the transceiver can get fl at, etc. and thus disable remote control.
ELKO EP declares that the RFSAI-62B-SL/MT type of equipment complies with Directives 2014/53/EU, 2011/65/EU, 2015/863/EU and 2014/35/EU. The full EU Declaration of Conformity is at: https://www.elkoep.com/switch-unit-with-inputs-for-external-buttons-matter-rfsai-62b-slmt
CONTACT
- ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
- Tel.: +420 573 514 211, e-mail: elko@elkoep.com,
- www.elkoep.com
- www.elko.li/rfsai-62b-sl-mt
Documents / Resources
![]() |
ELKO EP RFSAI-62B Switch Unit with Inputs for External Buttons [pdf] Instruction Manual RFSAI-62B-SL-MT, RFSAI-62B Switch Unit with Inputs for External Buttons, RFSAI-62B, Switch Unit with Inputs for External Buttons, Inputs for External Buttons, External Buttons |