Elitech RCW-360 Pro Temperature Humidity Data Logger User Manual

RCW-360 Pro Temperature Humidity Data Logger

Specifications

  • Power input:
  • Temperature display resolution:
  • Humidity display resolution:
  • Number of offline recording groups:
  • Data storage mode: circular storage
  • Record, upload interval, and alarm interval:
  • Battery life:
  • Indicator light: alarm indicator, charging indicator
  • Screen: TFT color screen
  • Buttons:
  • Alarm buzzer:
  • Communication:
  • Location mode:
  • Alarm modes: local alarm and cloud alarm
  • Waterproof grade:
  • Working environment:
  • Specification and dimension:

Product Usage Instructions

1. Installing and Removing the Probe

Follow the instructions provided in the manual for installing
and removing the probe correctly.

2. Charging

Connect the device to the power adapter using the USB cable for
charging. The charging indicator will flash during charging and
remain on when fully charged.

3. Power On/Off

Turn on the device to start recording data based on the set
recording interval and report data as per the upload interval.

4. Real-Time Data

Access real-time monitoring data through the device’s
display.

5. Maximum and Minimum Values

Press the Menu key to view maximum and minimum values recorded
by the device.

6. Viewing Records and Setting Upload Intervals

Access the Record and Upload Interval settings by pressing the
Menu button. Adjust these settings as needed through the
accompanying APP.

7. View Device Information

Press the Menu button to view detailed device information
including model, sensor details, version, GUID, IMEI, and SIM card
ICCID (only for Wi-Fi version).

Frequently Asked Questions (FAQ)

Q: What probe types are compatible with this device?

A: The compatible probe types are listed in the provided
selection list in the manual.

Q: How do I access historical data using the Elitech iCold
platform?

A: You can access historical data by logging into the Elitech
iCold platform or using the accompanying APP for remote data
viewing and historical data queries.

“`

RCW- Pro 4G/WiFi
USER MANUAL
Elitech iCold Platform: new.i-elitech.com

This product is a wireless Internet of Things monitor, providing such functions as real-time monitoring, alarm, data recording, data uploading, large screen display, etc. of temperature and humidity at monitoring points.Together with the “Elitech iCold” platform and APP, it can realize functions such as remote data viewing, historical data query, remote alarm push, etc. It is widely used in food, medicine, catering, international warehousing and logistics industries.
1. Features The product is suitable for various occasions, including warehouse, refrigerated storage, refrigerator car, shade cabinet, medicine cabinet, refrigerator lab, etc; Compact size, fashionable appearance, magnetic card tray design, easy installation; Large TFT color screen display, rich in content; Built-in rechargeable lithium battery enables long-time real-time data upload after power cut; Built-in sound-light alarm device can realize local alarm;
probe types see the selection list.
2. Interface

Figure: Gel bottle Sensor

Charging indicator

Charging interface Alarm status indicator “Menu” button
1

Magnetic card tray Screen

3. Model Selection List

Tips:The specific host model is subject to the actual product;

Probe model: the conventional probe models are shown in the table below:

Probe type

Single

Dual

temperature temperature

Gel bottle temperature

Temperature and humidity

Ultra low temperature

Low

High

Concentration Concentration

Model

Cable

Point

One

Two

One

temperature temperature temperature

probe

probe

probe

humidity probe

One temperature
probe

Concentration Concentration

Range

Accuracy
Sensor type Digital temperature and humidity sensor, Digital temperature sensor Analog to digital sensor Sensor interface Note:

reading) reading) Carbon Dioxide Sensor

adapt to the above types of probes.

1. Power input: 2. Temperature display resolution: 3. Humidity display resolution: 4. Number of offline recording groups: 5. Data storage mode: circular storage. 6. Record, upload interval and alarm interval:

7. Battery life:
8. Indicator light: alarm indicator, charging indicator. 9. Screen: TFT color screen. 10. Buttons: 11. Alarm buzzer: 12. Communication: 13. Location mode: 14. Alarm modes: local alarm and cloud alarm. 15. Waterproof grade: 16. Working environment: 17.Specification and dimension:
2

1. Installing and removing the probe
2. Charging Connect to the power adapter via USB cable. When charging, the charging indicator flashes, when it is fully charged, the charging indecator is always on. 3. Power on/off Start recording data according to the recording interval after turn on, and report data according to the upload interval. 4. Real time data
Networking signal icon: Connect to the base station and display a signal bar. If the device networking is abnormal, an “X” will be displayed in the upper left corner of the signal. Channel identification: Real time temperature or humidity: probe, the corresponding position will display “OFF”. Upper and lower alarm limits: The data below the lower limit will be displayed in blue, and the data above the upper limit will be displayed in red. Number of data not uploaded: Displays the number of recorded but not uploaded data. Battery icon: Four bar battery indicator. When charging, the battery indicator flashes and Time and date
3

5. Maximum and Minimum Short press the “Menu” key to enter the “Maximum and Minimum” page, as shown in the or single temperature probe. The B data displays “-~-“.
6. Viewing records and uploading intervals Short press the “Menu” button to enter the “Record and Upload Interval” page, as shown in the following figure, which can be set through the APP.
7. View device information Press the “Menu” button to enter the “Device Information” page, as shown in the following figure. You can query the model, Sensor, version, GUID, IMEI, SIM card ICCID(only for Wi-Fi version)
8. Adding devices to the platform and basic operations Adding decices to the platform and operation, please refer to “IV Elitech iCold”.
4

The Elitech iCold Cloud platform supports two methods for adding and managing devices: APP or WEB client. The following mainly introduces the APP method. WEB client can log in to new.i-elitech.com for operation. 1. Download and Install APP Please scan the QR code on the cover of the manual or search Elitech iCold APP Store or Google play to download Elitech App. 2. Account registration and APP Login information, and click “Login”After entering the APP, select ” New “. PS: a. If you have not an account, please click on “Register
follow the prompts and enter verification information to complete account registration. b. If you forget the password, click “Forget password
According to the prompts to finish verfication and find out password.
5

3. Add Device
1. Click ” ” in the upper right corner 2. Click ” ” in the upper right corner, scan the QR code or enter GUID back on the device, then fill
in the device name and choose time zone. 3. Click ” “, the device is added.

1

2

3

Tip

restart the device before turning it on. The device uploads data according to the set reporting

unable to resolve, please call the service hotline for consultation.

4. WIFI distribution network(WIFI version only)

corner of the device
Note: Please do not exit this page during the distribution network process.
6

following figures ~

5. Configure probe type When using the device for the first time or changing the probe type, it is necessary to

Operation method: Log in to the APP select the device to be changed select “Parameter Configuration” select “User Parameters” select the corresponding probe model based on the actual selected probe type and channel click “SET”.

Note:

Figure 4

Figure 5

the probe type to the device, or the device can be restarted to synchronize immediately.

there may be faulty data in the data list.

7

6. Device management Click on the device on the main page of the APP to enter the device management related page. You can view device information, change device names, view data lists, set alarm upper and lower limits, record/upload intervals, configure alarm push, view maps, export reports, and other operations.
For more functions, Please log in Elitech iCold Platform: new.i-elitech.com. Free data & advanced platform service will be activated after the device be first time registered to Elitech platform. After the probation period, customers need to recharge the device by referring to operation manual.
8

V1.4

Documents / Resources

Elitech RCW-360 Pro Temperature Humidity Data Logger [pdf] User Manual
RCW-360Pro, RCW-Pro 4G-WiFi, RCW-360 Pro Temperature Humidity Data Logger, RCW-360, Pro Temperature Humidity Data Logger, Humidity Data Logger, Data Logger

References

Leave a comment