Overview

The RC -4 series are multi – use data loggers with external temperature probe, where RC-4 is a temperature logger, RC-4HC is a temperature and humidity logger.

They can be used to record temperature/humidity of foods, medicines and other goods during storage, transportation and in each stage of the cold chain including cooler bags, cooling cabinets, medicine cabinets, refrigerators, laboratories, reefer containers and trucks.

Elitech Multi Use Temperature Data Logger - Overview

Specifications

Elitech Multi Use Temperature Data Logger - Specifications

Operation

Battery Activation
  1. Turn the battery cover counterclockwise to open it .
  2. Gently press the battery to hold it in position, then pull out the battery insulator strip.
  3. Turn the battery cover clockwise and tighten it.

Elitech Multi Use Temperature Data Logger - Battery Activation

Install Probe

By default, RC-4/4HC uses the internal sensor to measure temperatures.
If you need to use the external temperature probe, simply install it as shown below:

Elitech Multi Use Temperature Data Logger - Install Probe

Install Software

Please download and install the free Elitechlog software (macOS and Windows) from Elitech US:
www.elitechustore.com/pages/download
or Elitech UK: www.elitechonline.co.uk/software
or Elitech BR: www.elitechbrasil.com.br.

Configure Parameters

First, connect the data logger to your computer via USB cable, wait until the Elitech Multi Use Temperature Data Logger - Connect Icon icon shows on the LCD; then configure via:

Elitechlog Software:

– If you do not need to change the default parameters (in Appendix); please click Quick Reset under Summary menu to synchronize local time before usage;
– If you need to change the parameters, please click the Parameter menu, enter your preferred values, and click the Save Parameter button to complete the configuration.

Warning! Far first time user or after battery replacement:
To avoid time or time zone errors , please make sure you click Quick Reset or Save Parameter before usage to sync and configure your local time into the logger.

Start Logging

Press Button: Press and hold the button for 5 seconds until the ► icon shows on the LCD, indicating the logger starts logging.

Note: If the ► icon keeps flashing, it means the logger configured the start delay; it will start logging ofter the set delay time elapses.

Stop Logging

Press Button*: Press and hold the button for 5 seconds until the ■ icon shows on the LCD, indicating the logger stops logging.

Auto Stop: When the logging points reach the maximum memory of 16 ,000 points, the logger will stop automatically.

Use Software: Open ElitechLog software , click Summary menu, and Stop Logging button.

Note: *Default stop is via Press Button , if set os disabled, the button stop function will be invalid;
Please open the ElitechLog software and click Stop Logging button to stop it .

Download Data

Connect the data logger to your computer via USB cable, wait until the Elitech Multi Use Temperature Data Logger - Connect Icon icon shows on the LCD; then download via :
ElitechLog Software: The logger will auto-upload data to ElitechLog, then click
Export to select your desired file format to export. If data failed for auto-upload, please manually click Download and then follow the export operation.

Reuse the Logger

To reuse a logger, please stopped it first; then connect it to your computer and use ElitechLog software to save or export the data.
Next, reconfigure the logger by repeating the operations in 4. Configure Parameters *.
After finished, follow 5. Start Logging to restart the logger for new logging.

Warning’ • To make space for new loggings, oil previous logging doto inside the logger will be deleted after re-configuration.

Status Indication

Buttons

Elitech Multi Use Temperature Data Logger - Buttons

LCD Screen

Elitech Multi Use Temperature Data Logger - LCD Screen

LCD Interface

Elitech Multi Use Temperature Data Logger - LCD Interface

LCD-Buzzer Indication

Elitech Multi Use Temperature Data Logger - LCD-Buzzer Indication

Battery Replacement

  1. Turn the battery cover counterclockwise to open it.
  2. Install the new and wide-temperature CR24S0 battery into the battery compartment with its+ facing upward.
  3. Turn the battery cover clockwise and tighten it .

What’s Included

• Data Logger x l
• CR24S0 battery x l
• External Temperature Probe x 1 (1.lrn)
• USB Cable x 1
• User Manual x 1
• Certificate of Calibration x 1

warningWarning

  • Please stare your logger at roam temperature.
  • Please pull out the battery insulator strip in the battery compartment before using.
  • If you use the logger far the first time, please use ElitechLag software ta synchronize system time and configure parameters.
  •  Do not remove the battery if the logger is recording.
  • The LCD screen will be auto off after 75 seconds of inactivity /by default). Press the button again to turn on the screen.
  • Any parameter configuration an ElitechLag software will delete all lagged data inside the logger. Please save data before you apply any new configurations.
  • To ensure the humidity accuracy of RC-4HC. please avoid contact with unstable chemical solvents or compounds, especially avoid long-term storage or exposure to the environments with high concentrations of ketene, acetone, ethanol, isaprapanal, toluene, etc.
  •  Do not use the logger far long-distance transport if the battery icon is less than half as Elitech Multi Use Temperature Data Logger - battery icon (Half).

Appendix

Default Parameter Configurations

Elitech Multi Use Temperature Data Logger - Default Parameter Configurations

Documents / Resources

PDF thumbnailMulti Use Temperature Data Logger
User Manual · RC-4, RC-4HC, Temperature Data Logger

References

Questions and answers

Helpful product questions tied to this manual. Each item links to the full Q&A page.

Questions & Answers

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

  1. Greetings, can you help me? I have a problem with the RC 4HC datalogger
    – Does not record data after disconnecting from the software and pressing the button does not activate the screen.
    Saludos, me pueden ayudar tengo un inconveniente con el datalogger RC 4HC
    – No registra los datos después que se desconecta del software y al presionar el botón no se activa la pantalla.

    Tatiana Guevara asks <em>Greetings, can you help me? I have a problem with the RC 4HC datalogger
    - Does not record data after disconnecting from the software and pressing the button does not activate the screen.<e/em>
    Saludos, me pueden ayudar tengo un inconveniente con el datalogger RC 4HC
    - No registra los datos después que se desconecta del software y al presionar el botón no se activa la pantalla.
    Manuals+ clarified question
    Question

    Why is my Elitech RC-4HC data logger not recording data or turning on its screen after being disconnected from the software?

    Answer

    Based on the Elitech RC-4HC manual, here are the steps to resolve issues with data recording and screen activation:

    • Screen Activation: The LCD screen automatically turns off after 15 seconds of inactivity by default. To turn it back on, simply press the button once. If the screen remains blank, check if the battery insulator strip was removed or if the CR2450 battery needs replacement.
    • Starting the Recording: Disconnecting from the software does not automatically start the logging process. You must manually start it by pressing and holding the button for 5 seconds until the play icon (▶) appears on the LCD.
    • Software Configuration: Ensure you have clicked Quick Reset or Save Parameter in the ElitechLog software before disconnecting. This synchronizes the logger's internal clock and applies your settings. If the logger was not "Started" in the software or via the button, it will not record data.
    • Check Stop Mode: If the logger has reached its maximum memory (16,000 points), it will stop automatically. You must download the data and reconfigure the device in the software to reuse it.

    If the device still does not respond, try replacing the CR2450 battery, ensuring the '+' side faces upward.

  2. Good morning, I want to know why my registered ERR appears on the screen, thank you
    Muy buen día, quiero saber por que mi registrados le aparece en la pantalla ERR, gracias

    Adda Montero asks <em>Good morning, I want to know why my registered ERR appears on the screen, thank you
    Muy buen día, quiero saber por que mi registrados le aparece en la pantalla ERR, gracias
    Manuals+ clarified question
    Question

    Why does my Elitech data logger screen display 'ERR'?

    Answer

    While the standard user manual for the Elitech RC-4 series does not explicitly list an "ERR" code in its status indication section, this message typically indicates a sensor-related issue or a configuration error. Please try the following troubleshooting steps:

    • Check the External Probe: If you are using the external temperature probe, ensure it is firmly plugged into the device. If the device is configured to read from an external sensor but none is connected, it may display an error.
    • Re-configure via Software: Connect the logger to your computer and open the ElitechLog software. Click on Quick Reset or Save Parameter to synchronize the device and clear potential internal logic errors.
    • Battery Check: Ensure the CR2450 battery is properly installed with the "+" side facing upward and has sufficient charge. A very low battery can sometimes cause erratic display behavior.
    • Sensor Damage: If the error persists after resetting the software and checking the probe, the internal or external sensor may be damaged, requiring a replacement of the probe or the unit.

    If these steps do not resolve the issue, you can contact Elitech support at support@elitechus.com or call (+1) 408-844-4070.