1. Specification
Product Glance
Product Glance | Value |
---|---|
Model | LV06 |
Version | V2.1.0 |
Crypto algorithm/coins | SHA256 |
Typical hashrate, GH/s(1-1) | 500±10% |
Power on wall @25°C(1-2), Watt(1-1) | 15±10% |
Detailed Characteristics
Power supply
Power supply | Value |
---|---|
AC input voltage range, V(2-1) | 100~240V AC |
AC input frequency range, Hz | 50/60 |
AC input current, A(2-2) | 0.6 |
Adapted AC output power requirement, W(2-3) | 60 |
Hardware configuration
Hardware configuration | Value |
---|---|
Networking connection mode | WiFi 2.4G/Hotspot |
Server size (Length*Width*Height, w/o package), mm | 105*60*33 |
Server size (Length*Width*Height, with package), mm | 206*163*60 |
Net weight, g | 136 |
Gross weight, g | 500 |
Noise, dBA @25°C (2-4) | 38 |
Environment requirements
Environment requirements | Value |
---|---|
Operation temperature, °C | 0~30 |
Storage temperature, °C | -20~70 |
Operation humidity, RH | 10%~90% |
Operation altitude, m (2-5) | ≤2000 |
2. Conditions for using "Luckyminer LV06"
2.1 Power Requirements:
Ensure the device is connected to a stable power source and meets the corresponding voltage and power requirements.
2.2 Environmental Conditions:
It is recommended to use the device in a dry, well-ventilated environment to avoid overheating or moisture.
- 2.2.1 Good ventilation.
- 2.2.2 It is prohibited to stack multiple devices or place them close together.
- 2.2.3 Do not place the device in a confined space.
2.3 Temperature Range:
Operate within ≤30°C to ensure device stability and performance.
2.4 Equipment heat dissipation:
- 2.4.1 Ensure smooth ventilation at the air inlet and outlet of the device.
- 2.4.2 Blocking the air inlet and outlet of the device is strictly prohibited.
2.5 Network Connection:
Ensure the device is properly connected to the network and compatible with the selected mining pool protocol.
2.6 Maintenance:
Regularly clean the device and pay attention to maintaining the cooling system to ensure proper operation.
2.7 Usage Restrictions:
- 2.7.1 Avoid using the device in excessively harsh environmental conditions and adhere to manufacturer's recommendations and warnings to maintain long-term stability.
- 2.7.2 It is prohibited to upgrade to unofficial firmware. No after-sales service will be provided when upgrading firmware under unofficial guidance.
3. Recommended parameters
- 3.1 Frequency: ≤575MHz, when the power consumption is >17W, please gradually reduce the frequency.
- 3.2 Core voltage: ≤1300mV, when the power consumption is >17W, please gradually reduce the voltage.
4. Mining Mode
Mining mode | Mechanism description |
---|---|
SOLO | SOLO mining means mining cryptocurrency alone, earning full rewards upon discovering new blocks. |
PPLNS | PPLNS mining refers to a payment model where miners' rewards are calculated based on their last N submitted valid shares. |
P2P | P2P mining refers to mining directly within the blockchain network by connecting to other nodes, rather than using centralized mining pools. |
PPS | PPS mining refers to a payment model where miners receive rewards based on the number of valid shares they submit. |
5. Mineable projects
Item | Project Name | Pool 1 | Pool 2 | Pool 3 |
---|---|---|---|---|
1 | BTC | pool.vkbit.com:3333 | public-pool.io:21496 | www.viabtc.com |
2 | BCH | p2p-spb.xyz:9338 | Solo-bch.2miners.com:9090 | www.viabtc.com |
3 | BSV | bsv.gorillapool.io:3333 | europe.mining-dutch.nl:4014 | |
4 | DGB | pool4ever.com:5109 | pool.dgb256.online:8080 | p2p-spb.xyz:5027 |
5 | XEC | hashpool.live:10043 | xec.luckymonster.pro:9113 | mining.viabtc.io:3014 |
6 | RBL | mining4people.com:4181 | afinepool.xyz:4931 | pool4ever.com:5014 |
7 | BTCP | na.mining4people.com:3452 | 82.137.50.129:3420 | btcp.mr-miner.org:5448 |
8 | BIT | 38.242.200.177:4611 | 103.230.158.177:50114 | 54.39.49.96:3442 |
9 | AUR | p2p-spb.xyz:12349 | pool4ever.com:5115 | valhala.is:3730 |
10 | WCN | pool4ever.com:5112 | na.mining4people.com:3334 | 103.249.70.25:4369 |
11 | PPC | pool4ever.com:5010 | solo.1pool.org:4004 | kriptokyng.com:3312 |
12 | RVB | connect.reversedbitcoin.org:11300 | zeusminingpool.com:5110 | na.mining4people.com:3415 |
13 | ACG | pool4ever.com:5140 | mining-pool.zapto.org:3450 | |
14 | LCC | sha256.na.mine.zergpool.com:3333 | us-stratum.coinminerz.com:3310 | p2p-spb.xyz:5555 |
15 | GLT | au.merged.stratum.cminors-pool.com:58900 | pool.cryptopowered.club:1064 | |
16 | X1C | Mining4people:3355 | poolkh.com:4468 |
Notes:
- LV06 is applicable to all SHA256 algorithm projects.
- For more mining pools, please refer to https://miningpoolstats.stream/bitcoin.
- Due to regional and mining pool access difficulties, LV06 cannot access all mining pools.
6. Operating instructions
6.1 Product list
- LV06 miner * 1
- Adapter(5V/6A,100-240V Input) *1
- AC line *1
6.2 Power on
- Connect the AC cable to the adapter input.
- Connect adapter output to miner DC port.
- After power on, the adapter indicator light is green, the miner fan is running, and the miner screen displays "connect to ssid: Lucky_ ****".
6.3 Connect to network
- Search for the miner hotspot "Lucky_ ****" through WiFi on your phone or computer.
- Select the "Lucky_ ****" hotspot (mobile or computer).
- Wait for 5-10 seconds, automatically redirect to the mining configuration interface.
6.4 Mining configuration
6.4.1 We can enter the settings interface in 6.3.3 or by entering the IP in the browser.
6.4.2 Explanation of Setting Interface:
No. | Setting items | Explanation |
---|---|---|
1 | WiFi SSID | WiFi name (special characters are strictly prohibited) |
2 | WiFi Password | WiFi password (special characters are strictly prohibited) |
3 | Stratum URL | Mining pool address or IP address |
4 | Stratum Port | Mining pool port number (multiple ports in the same mining pool correspond to different difficulties) |
5 | Stratum User | Registered username or main network wallet address for the mining pool |
6 | Frequency | ASIC IC operating Frequency(500-575MHz) |
7 | Core Voltage | ASIC IC core voltage(1200-1300mV) |
6.4.3 Settings completed, click the "Save" button.
6.4.4 After saving the settings, click the "Restart" button.
6.5 View running status
- Restart completed, wait for 30-60 seconds, the Home page will display the real-time running status of the miner. Contains information such as "Overview", "Power", "Pool information", "Results", etc...
- The miner screen will synchronously scroll to display the above information.
6.6 View the status of pool
- Log in to the mining pool website or app used by Miner.
- Check online device status through username or wallet address.
6. FAQ for Luckyminer LV06
No. | Fault Description | Fault pictures | Possible causes | Solution | Solving diagram |
---|---|---|---|---|---|
1 | Miner is powered on but cannot connect to WiFi | Image of miner screen showing "connect to ssid: Lucky_1860" | Using non 2.4G WiFi | Check WiFi type, must use 2.4G WiFi (Router/Hotspot) |
WiFi SSID: xsl_h1 WiFi Password: xiaoqiang |
WiFi name or password has special characters | WiFi name and password must be in English/numbers, or a combination of English and numbers. | ||||
2 | Miner is powered on, the screen and fan do not work. | [Miner Fan] | The control IC is not started | When powered on, press the reset button to reset the main control chip (1-3 times). | [Reset Button] |
3 | Miner is powered on, the screen does not light up and the fan works. | [Miner Fan] | The control IC is not started | When powered on, press the reset button to reset the main control chip (1-3 times). | [Reset Button] |
4 | The adapter light does not light up or keeps flashing. | [Adapter Indicator Light] | The adapter does not output or the output is unstable. | Replace adapter. | |
5 | WiFi, Power consumption is normal, hash value is 0. |
Power: Power Consumption: 15.67 W Input Voltage: 4.841 mV Input Current: 3.238 mA Frequency: 575 Mhz Core Voltage: 1250 mV Measured Core Voltage: 1250 mV Fan Speed: 3082 RPM Chip Temperature: 60 C Results: Hash Rate: 0.00 Gh/s Efficiency: 0∞ W/Th Best Difficulty: 0 |
Mining pool address Check the mining pool address carefully and query mining pool related information: https://miningpoolstats.stream/bitcoin Port number There may be multiple port numbers in the same mining pool. Generally, different port numbers correspond to the difficulty of access. Please choose the appropriate port number. Mining pool difficulty All mining pools have a minimum access difficulty. Please ensure that the device computing power is below the mining pool access difficulty. Experience value: 500G can access a mining pool with difficulty <1000 (port number) Wallet address You must use the mainnet wallet address of the currency being mined. For example: the BTC mainnet address generally starts with 1/3/bc1. Username Some mining pools require a registered account to use. For this kind of mining pool, you need to fill in the miner name of the mining pool during configuration. |
Stratum Port: 3014 [Pool Default Difficulty: 1024] [Pool Minimum Difficulty: 256] Stratum User: bc1qsn80udljur00zn58eg7y7 Stratum User: super66.0x0x19 |
|
6 | Miner runs with low power consumption, <5W |
Power: Power Consumption: 2.70 W Input Voltage: 5,304 mV Input Current: 509 mA Frequency: 575 Mhz Core Voltage: 1250 mV Measured Core Voltage: 1251 mv Fan Speed: 4878 RPM Chip Temperature: 45 C |
The control IC is not started | When powered on, press the reset button to reset the main control chip (1-3 times). | [Reset Button] |
7 | Successfully connected to WiFi, miner restarted repeatedly. | Miner screen displaying status: Gh: 0.0 W/Th: nan, UT: Od 0h 0m, IP: 10.0.0.19, 0.00 h/s, 131.13 Gh/s, 202 | Mining pool resolution failed | Change mining pool. | |
8 | Miner keeps restarting and the Hashrate is unstable. | [Graph showing Hashrate fluctuation] | WiFi congestion and instability. | Change to a stable WiFi or hotspot. | |
Mining pools are regulated. | Change to a locally allowed mining pool or a well-known mining pool. | ||||
[Power Supply Unit] | High power consumption, high temperature, temperature protection. | The environment temperature is <30℃, and the equipment should be placed in a well-ventilated place. |
FCC Compliance
FCC Warning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution:
Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.