Specifications

  • Size (WxDxH): 440 x 280 x 44 mm (17.32 x 11.02 x 1.73 in.)
  • Weight:
    • ECS4155-30T: 3.85 kg (8.48 lb)
    • ECS4155-30P: 4.79 kg (10.56 lb)
  • Humidity: Operating: 5% to 95% (non-condensing)
  • Altitude: Operating: 3000 m (10,000 ft)
  • Power:
    • ECS4155-30T: 88 Watts maximum Consumption
    • ECS4155-30P: 950 Watts maximum
  • PoE Budget: ECS4155-30P: 750 Watts in total, 55V max/1.64A max per port
  • AC Input:
    • ECS4155-30T: 100-240 VAC, 50-60Hz, 1 A
    • ECS4155-30P: 100-240 VAC, 50-60Hz, 10 A
  • Regulatory Compliances:
    • Emissions: EN 55032, EN IEC 61000-3-2, EN 61000-3-3, FCC Class A, VCCI-CISPR 32 Class A, BSMI (CNS 15936), ICES-003 Issue 7 Class A, EN 300 386 Class A
    • Immunity: IEC 61000-4-2/3/4/5/6/8/11, EN 55035, EN 55024, EN 300 386
    • Safety: UL (CSA 22.2 No 62368-1 & UL62368-1), CB (IEC/EN 62368-1), BSMI (CNS 15598-1), Taiwan RoHS CNS 15663

Product Usage Instructions

Installation

  1. Mount the Device: Mount the device in the rack and secure it with rack screws.
  2. Ground the Device:
    1. Attach the Brackets: Use the included flathead M4x8 screws to attach the brackets.
    2. Connect the Grounding Wire: Connect the included grounding wire to the grounding point on the rear panel. Then connect the other end of the wire to rack ground.
  3. Connect Power: Connect an AC power source to the device.
  4. Make Network Connections:
    • RJ-45 Ports: Connect Cat.5e or better twisted-pair cable.
    • SFP28 Ports: Install transceivers and then connect fiber optic cabling to the transceiver ports.

    Supported transceivers:

    • 1000BASE-SX/LX/EX/ZX and 1000BASE-T (RJ-45)
    • 10GBASE-SR/LR/ER/ZR and 10GBASE-T (RJ-45)
    • 25GBASE-SR/LR

     

Alternatively, connect DAC or AOC cables directly to the port slots.

Package Contents

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (1)

  1. L2+ Gigabit Ethernet (PoE) Switch
  2. Rack mounting kit—2 brackets and 8 screws
  3. Power cord
  4. Power cord clamp
  5. Console cable—RJ-45 to DE-9
  6. Four adhesive rubber feet
  7. Grounding wire
  8. QR code label (affixed to the top of the switch)

Overview

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (2)

  1. System LEDs
  2. Management port, Console port, USB port, and Reset button
  3. 24 x 100M/1G/2.5G RJ-45 ports
  4. 6 x 1/10/25G SFP28 ports
  5. PoE LED and Display Mode button
  6. 24 x 100M/1G/2.5G RJ-45 PoE++ (IEEE 802.3bt) ports
  7. AC power socket
  8. Ground screw

System/Port LEDs & Buttons

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (3)

  1. PWR: Green (OK)
  2. SYS: Green (OK), Blinking Green (booting)
  3. RESET Button: <1s press – restart, >10s press – factory defaults
  4. RJ-45 Ports: Green/Blinking (link/activity)
  5. SFP28 Ports: Green/Blinking (link/activity)

ECS4155-30P

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (4)

  1. PWR: Green (OK)
  2. SYS: Green (OK), Blinking Green (booting)
  3. PoE: Green (PoE display mode), Off (link/activity display mode), Blinking Green (PoE over budget)
  4. DISPLAY MODE Button: Port LED display mode selection
  5. RESET Button: <1s press – restart, >10s press – factory defaults
  6. RJ-45 Ports: Green/Blinking (link/activity), Amber (PoE link)
  7. SFP28 Ports: Green/Blinking (link/activity)

Installation

Warning: For a safe and reliable installation, use only the accessories and screws provided with the device. Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty.

Note: The drawings in this document are for illustration only and may not match your particular model.

Mount the Device

  1. Attach the Brackets
    Use the included flathead M4x8 screws to attach the brackets.Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (5)
  2. Mount the Device
    Mount the device in the rack and secure it with rack screws.Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (6)

Ground the Device

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (7)Connect the included grounding wire to the grounding point on the rear panel. Then connect the other end of the wire to rack ground.

Connect Power

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (8)Connect an AC power source to the device.

Make Network Connections

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (9)

RJ-45 Ports
Connect Cat. 5e or better twisted-pair cable.

SFP28 Ports
Install transceivers and then connect fiber optic cabling to the transceiver ports. The following transceivers are supported:

  • 1000BASE-SX/LX/EX/ZX and 1000BASE-T (RJ-45)
  • 10GBASE-SR/LR/ER/ZR and 10GBASE-T (RJ-45)
  • 25GBASE-SR/LR

Alternatively, connect DAC or AOC cables directly to the port slots.

Make Management Connections

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (10)

10/100/1000M RJ-45 Management Port
Connect Cat. 5e or better twisted-pair cable.

RJ-45 Console Port
Connect the included console cable and then configure the serial connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.

USB Port
The USB 2.0 port allows you to copy a runtime or configuration file to/from a USB memory stick. (The USB port only supports a simple data storage device using a FAT16/32 file system with or without a partition table.)

Warranty Information and Technical Support
Registering your product enables you to receive a more efficient warranty service. Be sure to register at www.edge-core.com.

Safety & Regulatory Information

  • L2+ Gigabit Ethernet (PoE) Switch
  • ECS4155-30T | ECS4155-30P
  • FCC Class A

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

  • You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
  • You may use unshielded twisted-pair (UTP) for RJ-45 connections – Category 3 or better for 10 Mbps connections, Category 5 or better for 100 Mbps connections, Category 5, 5e, or 6 for 1000 Mbps connections. For fiber optic connections, you may use 50/125 or 62.5/ 125 micron multimode fiber or 9/125 micron single-mode fiber.

CE Mark

  • CE Mark Declaration of Conformance for EMI and Safety (EEC)
  • This information technology equipment complies with the requirements of the Council Directive 2014/30/EU on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 2014/ 35/EU for electrical equipment used within certain voltage limits. For the evaluation of the compliance with these Directives, the following standards were applied:

RFI Emission:

  • Limit according to EN 55032, Class A
  • Limit according to EN 300 386 Class A
  • Limit for harmonic current emission according to EN 61000-3-2, Class A
  • Limitation of voltage fluctuation and flicker in low-voltage supply systems according to EN 61000-3-3

Immunity:

  • Product family standard according to EN 55024
  • Product family standard according to EN 55035
  • Product family standard according to EN 300 386
  • Electrostatic Discharge according to IEC 61000-4-2
  • Radio-frequency electromagnetic field according to IEC 61000-4-3
  • Power frequency magnetic field immunity test according to IEC 61000-4-8
  • Voltage dips, short interruptions and voltage variations immunity test according to IEC 61000-4-11

LVD:

  • EN 62368-1:2014/A11: 2017

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (11)The Declaration of Conformity (DoC) can be obtained from www.edge-core.com -> support -> download.

 

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (12)Mayflex UK Ltd
Junction Six Industrial Park, Electric Avenue, Birmingham B6 7JJ United Kingdom

Vesper Technologies Limited
Unit 5/6 Rugby Park, Bletchley Road, Heaton Mersey, Stockport SK4 3EJ United Kingdom

Japan – VCCI Class A

Laser Safety

Warning: Fiber Optic Port Safety:

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (13)The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly into the laser light emitted by a transceiver.

Power and Battery Safety

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (14)Warning: If your device uses a lithium battery, do not attempt to replace the battery yourself. Return the device to the manufacturer for battery replacement.

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (15)If the device contains lithium batteries that are encased in a sealed chassis, do not attempt to open the sealed chassis under any circumstances.

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (16)Risk of explosion if the battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- (18)Caution – Risk of Electrical Shock: To disconnect power, remove all power cords from the unit.

Power Cord Safety
Please read the following safety information carefully before installing the device:

Warning: Installation and removal of the unit must be carried out by qualified personnel only.

  • The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.
  • Do not connect the unit to an A.C. outlet (power supply) without an earth (ground) connection.
  • The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN 60320/IEC 320 appliance inlet.
  • The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet.
  • This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950-1 and/or 62368-1. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.

This unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labeled Neutral, connected directly to earth (ground).

Important!
Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following:

Power Cord Set

U.S.A. and Canada

  • The cord set must be UL-approved and CSA certified.
  • The minimum specifications for the flexible cord are:
    • Min. 1.5 m and Max. 4.5 m long, Type SJE, SJT, ST or SJTO, No. 16 AWG.
    • Min. 1.5 m and Max. 2.4 m long, Type SVT or SPT-2, No. 16 AWG
    • 3-conductor
  • The cord set must have a rated current capacity of at least 10 A.
  • The attachment plug must be an earth-grounding type with NEMA 5-15P (15 A, 125 V) configuration.

U.K.

  • The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with a 5 A fuse which complies with BS1362.
  • The mains cord must comply with IEC 60227 (designation 60227 IEC 52).

Europe

  • The supply plug must comply with CEE7/7 (“SCHUKO”).
  • The mains cord must comply with IEC 60227 (designation 60227 IEC 52).
  • IEC-320 receptacle.

Warnings and Cautionary Messages

  • Warning: This product does not contain any serviceable user parts.
  • Warning: Installation and removal of the unit must be carried out by qualified personnel only.
  • Warning: When connecting this device to a power outlet, connect the field ground lead on the tri-pole power plug to a valid earth ground line to prevent electrical hazards.
  • Warning: This device uses lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look  directly at a transmit port when it is powered on.
  • Warning: When selecting a fiber SFP28 device, considering safety, please make sure that it can function at a temperature that is not less than the recommended maximum operational temperature of the product. You must also use an approved Laser Class 1 SFP28 transceiver.
  • Caution: Wear an anti-static wrist strap or take other suitable measures to prevent electrostatic discharge when handling this equipment.
  • Caution: Do not plug a phone jack connector in the RJ-45 port. This may damage this device.
  • Caution: Use only twisted-pair cables with RJ-45 connectors that conform to FCC standards.

Edge-Core-ECS4155-30T-Gigabit-Ethernet-Poe-Switch-FIG- 19

FAQs

Q: What type of cables can be used for network connections?
A: For RJ-45 ports, Cat.5e or better twisted-pair cables can be used. For SFP28 ports, fiber optic cabling with compatible transceivers or DAC/AOC cables can be used.

Q: How do I reset the device to factory defaults?
A: Press and hold the RESET button for 10 seconds to restore the device to factory defaults.

Documents / Resources

Edge Core ECS4155-30T Gigabit Ethernet Poe Switch [pdf] User Guide
ECS4155-30T, ECS4155-30P, ECS4155-30T Gigabit Ethernet Poe Switch, ECS4155-30T, Gigabit Ethernet Poe Switch, Ethernet Poe Switch, Poe Switch

References

Leave a comment

Your email address will not be published. Required fields are marked *