Edge-corE-logo

Edge-corE AS9947-36XKB AC Ethernet Switch and Router

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-product

Package Contents

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (1)

  1. AS9947-36XKB AC or AS9947-36XKB DC Ethernet Switch/Router
  2. Rack mounting kit — 2 rack-rail assemblies
  3. 2 x AC power cord (included with AC PSUs only)
  4. 2 x DC power cable (included with DC PSUs only)
  5. Grounding kit — grounding lug, 2 screws, and 2 washers
  6. Console cable — RJ-45 to DB-9
  7. Documentation — Quick Start Guide (this document) and Safety and Regulatory Information

Overview

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (2)

  1. 4 x 10G SFP+ (combined with 100G port 0)
  2. 24 x 100G QSFP28
  3. 12 x 400G QSFP-DD
  4. RJ-45 Management port
  5. RJ-45 Console port
  6. System LEDs
  7. Timing ports: 1 x RJ-45 ToD port, 1 x 1PPS connector, 1 x 10MHz connector
  8. USB port
  9. Reset button
  10. Product tag
  11. Grounding points
  12. 2 x AC or DC PSUs
  13. 4 x fans

Front LEDs

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (3)

  1. SFP+ Port LEDs:
    • LED1 (left) — Yellow (10G); LED2 (right) — Link/Activity*
  2. QSFP28 Port LEDs:
    • LED1 (left) — Blue (100G), Green (40G), Cyan (25G), Yellow (10G); LED2 (right) — Link/Activity*
  3. QSFP-DD Port LEDs:
    • LED1 (top) — Magenta (400G), Blue (100G), Cyan (25G),
    • Yellow (10G); LED2 (bottom) — Link/Activity*
    • LED2 (right/bottom) — Green (all lanes linked), Yellow (not all lanes linked), Blinking (activity)
  4. Management Port LEDs:
    • RJ-45 OOB Port — Left (activity), Right (speed)
  5. System LEDs:
    • DIAG — Green (OK), Red (fault detected)
    • LOC — Flashes Blue when the command is activated
    • FAN — Green (OK), Red (fault)
    • PSU0 and PSU1 — Green (OK), Red (fault)

FRU Replacement

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (4)

PSU Replacement

  1. Remove the power cord.
  2. Press the release latch and remove the PSU.
  3. Install replacement PSU with matching airflow direction.

Fan Tray Replacement

  1. Press the release latch on the fan tray handle.
  2. Pull out to remove the fan.
  3. Install replacement fan with matching airflow direction.

Air Filter Attachment/Replacement

  1. Unscrew the filter cover captive screws.
  2. Remove the old filter and install a replacement filter.
  3. Replace the filter cover and tighten the captive screws.

Installation

Warning
For a safe and reliable installation, use only the accessories and screws provided with the device. The use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty.
Note: The device has the Open Network Install Environment (ONIE) software installer preloaded, but no software image. Information about compatible software can be found at www.edge-core.com.
Note: The drawings in this document are for illustration only and may not match your particular model.

Attach Grounding Wire
Attach the lug to a #6 AWG minimum grounding wire (not included), and connect it to the grounding points on the device’s rear panel. Then connect the other end of the wire to the rack ground.

Caution: The chassis ground connection must not be removed unless all supply connections have been disconnected.
Caution: The device must be installed in a restricted-access location. It should have a separate protective ground terminal on the chassis that must be permanently connected to a well-grounded chassis or frame to adequately ground the device chassis and protect the operator from electrical hazards.

Mount the Device

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (5)

Using the Slide-Rail Kit
Follow the instructions in the install guide provided in the slide-rail kit to mount the device in a rack.

Note: Stability hazard. The rack may tip over causing serious personal injury. Before extending the rack to the installation position, read the installation instructions. Do not put any load on the slide-rail-mounted equipment in the installation position. Do not leave the slide-rail-mounted equipment in the installation position.

Ground the Device

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (6)

Verify Rack Ground
Ensure the rack on which the device is to be mounted is properly grounded and in compliance with ETSI ETS 300 253. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment).

Connect Power

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (7)

  • AC Power

If the AC input rating is 100–127 VAC, install two AC PSUs and connect them to separate AC power outlets. (Preferred) If the AC input rating is 200–240 VAC, install one or two AC PSUs and connect them to an AC power source.
Note: When using a 100-127 VAC power input, PSUs operate in low-line mode and may not support full power redundancy under certain circumstances. It is recommended to use a 200- 240 VAC power input to achieve optimal performance.

DC Power
Install one or two DC PSUs and connect them to a DC power source using the included DC power cables.

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (8)

Caution: Use an IEC/UL/EN 60950-1 and/or 62368-1 certified power supply to connect to a DC converter.
Caution: All DC power connections should be performed by a qualified professional.
Note: Use #6 AWG/ 10 mm2 copper wire (for a -48 to -60 Vdc PSU) to connect to a DC PSU.

Perform Initial System Boot

  1. ONIE Installer Software
    If the network operating system (NOS) installer is located on a network server, first connect the RJ-45 Management (Mgmt) port to the network using a 100-ohm Category 5, 5e, or better twisted-pair cable. (Not required if the NOS installer is located onthe  attached storage.)
  2. Boot the Device
    Wait for the ONIE software to locate and execute the NOS installer, and then wait for the installer to load the NOS software image. Subsequent device boots will bypass ONIE and directly run the NOS software.

Note: For devices with ONIE software pre-loaded, refer to the network operating system (NOS) installer and NOS documentation for details on software options and setup for ONIE.

Connect Timing Ports

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (9)

RJ-45 ToD
Use a Cat. 5e or better twisted-pair cable to connect the Time of Day to other synchronized devices.

10MHz 1PPS
Use coax cables to connect the 10MHz and 1-pulse-per-second (1PPS) ports to other synchronized devices.

Make Network Connections

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (10)

10G SFP+ Ports
Install transceivers and then connect fiber optic cabling to the transceiver ports.
The following transceivers are supported in the SFP+ ports: 1000BASE-T, SX, LX 10GBASE-SR, LR
Alternatively, connect DAC or AOC cables directly to the SFP+ slots.

Note: The 10G SFP+ ports are combined with 100G
QSFP28 port 0. You can use one or more of the SFP+ ports or the QSFP28 port, but not both at the same time.

100G QSFP28 Ports
Install transceivers and then connect fiber optic cabling to the transceiver ports.
The following transceivers are supported in the QSFP28 ports:

  • 40GBASE-SR4, LR4
  • 100GBASE-SR4, CWDM4, LR4, ER4, ZR4
  • Alternatively, connect DAC or AOC cables directly to the QSFP28 slots.

400G QSFP-DD Ports

  • Install transceivers and then connect fiber optic cabling to the transceiver ports.

The following transceivers are supported in the QSFP-DD ports: 400GBASE-SR8, DR4, FR4
Alternatively, connect DAC, AOC, or AEC cables directly to the QSFPDD slots.

Make Management Connections

Edge-corE-AS9947-36XKB-AC-Ethernet-Switch-and-Router-fig- (11)

MGMT RJ-45 Port
Connect Cat. 5e or better twisted-pair cable.

RJ-45 Console Port
Use the included RJ-45-to-DB-9 null-modem console cable to connectto a PC running terminal emulator software. Use a USB-to-male DB-9 adapter cable (not included) for connections to PCs that do not have a DB-9 serial port.
Configure the serial connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control. Console cable pinouts and wiring:

  • Device’s RJ-45 Console Null Modem PC’s 9-Pin DTE Port
  • 6 RXD (receive data) <————— 3 TXD (transmit data)
  • 3 TXD (transmit data) —————> 2 RXD (receive data)
  • 4,5 SGND (signal ground) —————– 5 SGND (signal ground)

Hardware Specifications

Interfaces

  • Management 1 x RJ-45 Console port 1 x RJ-45 10/100/1000BASE-T
  • Management port Network 4 x 10G SFP+ 24 x 100G QSFP28 12 x 400G QSFP-DD

Chassis

  • Size (WxDxH) 440 x 649.2 x 87 mm (17.3 x 25.5 x 3.4 in)
  • Weight 20.5 kg (45.18 lb)

Operating

  • Temperature 0° C to 45° C (32° F to 113° F)
  • Storage Temperature -40° C to 70° C (-40° F to 158° F)
  • Humidity Operating: 5% to 85% (non-condensing) Storage: 5% to 95% (non-condensing)
  • Typical Power
  • Consumption 421.5 W at 25° C (77° F), excluding transceivers.

System Input

  • DC Input -48 – -60 VDC, 50 A max. per PSU
  • AC Input 100-127 VAC, 50/60 Hz, 12 A max. per PSU
  • (Preferred) 200-240 VAC, 50/60 Hz, 10 A max. per PSU

Regulatory Compliances

  • Emissions EN 55032
  • EN 61000-3-2
  • EN 61000-3-3
  • FCC Part 15 subpart B Class A
  • Immunity EN 55024

EN 55035

  • IEC 61000-4-2/3/4/5/6/8/11
  • Safety UL/CUL (CAN/CSA22.2 No 62368-1 & UL 62368-1)
  • CB (IEC/EN 62368-1)
  • Taiwan RoHS CNS 15663

Documents / Resources

Edge-corE AS9947-36XKB AC Ethernet Switch and Router [pdf] User Guide
AS9947-36XKB AC, AS9947-36XKB DC, AS9947-36XKB AC Ethernet Switch and Router, AS9947-36XKB AC, Ethernet Switch and Router, Switch and Router, Router
Edge-corE AS9947-36XKB AC Ethernet Switch and Router [pdf] User Guide
AS9947-36XKB AC, AS9947-36XKB DC, AS9947-36XKB AC Ethernet Switch and Router, AS9947-36XKB AC, Ethernet Switch and Router, Switch and Router, Router

References

Leave a comment

Your email address will not be published. Required fields are marked *