ECOLAB AFS-1E Automated Filling Station

ECOLAB-AFS-1E-Automated-Filling-Station-PRODUCT

FAQs

  • Q: Can I use a different type of pump diaphragm than the standard Kalrez pump?
    • A: Yes, you can use Santoprene or Viton diaphragms as optional replacements for the standard Kalrez pump.
  • Q: What should I do if the compressed air pressure is below the recommended range?
    • A: If the incoming air pressure falls below 40 PSI, do not operate the unit to prevent potential operational issues. Check and adjust the air pressure accordingly before use.

SAFETY INFORMATION

Read this manual completely and understand the machine before operating or servicing it.

  • Read all instructions before installing or operating unit.
  • Unit is dedicated for the use of one product only. The product must be approved by an Ecolab application specialist.
  • Always wear appropriate personal protective equipment (PPE) when operating or servicing unit.
  • Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Material Safety Data Sheet (MSDS).
  • Incoming air pressure cannot exceed 100 PSI (7 bar).
  • Unit will not operate properly if incoming air pressure is below 40 PSI (2.7 bar).
  • Do not exceed a fluid temperature of 100˚F (37˚C).
  • Air quality must be ISO 8573-1, class 4.4.2 compliant.
  • Do not use air lubricator before the unit.
  • Do not use with hydrocarbons, solvents, degassing, or flammable products.
  • When working with hazardous substances that may harm or irritate skin and/or eyes, make sure that emergency showers and eyewash stations are available in accordance with European standards EN 15154-1/2.
  • NOTICE: It is illegal to operate or service unit in an EU member state if manual(s) is not written in that State’s language. Operators must read and understand the instruction manual before operating or servicing equipment. Please contact your equipment agent if translation is needed.

PROTECT THE ENVIRONMENT

Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations. Always remember to recycle. *Specifications and parts are subject to change without notice.

Specifications

  • Liquid Temperature …………. 40˚F to 100˚F (4.4˚C to 37˚C)
  • Priming Dry ……………….. 15 ft. (4.5 m)
  • Priming Wet………………… 20 ft. (6.1 m)
  • Flow Rate …………………… up to 5 GPM (18.9 L/min)
  • Air Supply Pressure ……… 20 to 100 PSI (1.4 to 6.9 bar)
  • Noise Level………………….. maximum 87 dB

Requirements:

Compressed Air Source Requirements: Compressed air 60 to 80 PSI (4 to 5.5 bar) with 2 CFM (56.7 l/min). Unit will not operate properly if incoming air pressure is below 40 PSI (2.7 bar). Chemical Requirements: Follow all instructions from the chemical manufacturer and Material Safety Data Sheet (MSDS).

Dimensions and Weight

  • Length ………………………………… 18.5 in (470 mm) approximately
  • Width …………………………………. 22 in (559 mm) approximately
  • Height ……………………………….. 46 in (1168 mm) approximately
  • Weight (AFS-1E) ………………………. 77 lbs (35 kg) approximately
  • Weight (AFS-1E-UPB) ………………… 80 lbs (37 kg) approximately
  • Maximum jug capacity (AFS-1E) ….. 6 gal (23 l) approximately
  • Maximum jug capacity (AFS-1E-UPB) … 2.4 gal (9 l) approximately

Air Operated Double Diaphragm Pump Models Offered:

  • P56: Polypropylene body with Santoprene diaphragm
  • P56V: Polypropylene body with Viton diaphragm
  • P56K: Polypropylene body with Kalrez diaphragm

Kalrez pump is the standard pump. Santoprene and Viton are optional replacements.

Intended use of the machinery

  • Transfer liquid from Ecolab chemical supply (220l drum/IBC) to small cans (Ecolab cans <30Kg or Ecolab User-Packs G2/G3).
  • AFS-1E for filling of Ecolab cans <30Kg from chemical supply.
  • AFS-1E-UPB for filling of Ecolab User-Pack G2/G3 from chemical supply.
  • Only Ecolab products are allowed for filling with the exception of degassing- or flammable products.
  • Filling of empty mentioned packaging specific for the same product as stored in the chemical supply

Notice: This system is designed to fill one type of chemical can / User-Pack consistently to a set level. It is not designed to fill multiple types of can / User-Pack or the same can / User-Pack to different levels.

INSTALLATION INSTRUCTIONS

  • Team lifting is required when lifting this unit. Carefully plan the lift. Be conservative when estimating how much weight a team can handle.
  • All members must understand the lifting plan and how to complete their tasks safely.
  1. Remove all parts from the shipping box.
  2. Select the desired area to mount the AFS-1E/AFS-1E-UPB. The AFS-1E/AFS-1E-UPB should be mounted on a vertical wall no more than 2 feet (61 cm) off the floor. It is possible to mountthe system up to 30 feet (9 m) away from the chemical source but it is best to be as close as possible to ensure easy priming of the pump.
    • Keep space around the unit clear – there should be at least 3.3 feet (1m) of space on the left and right sides, and 6.6 feet (2m) in front of the unit, as shown in the diagram.ECOLAB-AFS-1E-Automated-Filling-Station-FIG (2)
  3. There is a black plastic hose barb attached to one end of the suction line. From the back of the unit, pass this end of the suction line through one of the holes in the back of the unit. Clip the hose barb into the empty port on the P56/P56V/P56K pump. Slide the clip on the pump toward the suction line to secure the suction line. Run the open end of the suction line along one of the slots in the back of the AFS-1E and out to your chemical supply.
  4. Screw PW1246-SL into HV60. The PW1246-SL will sit in your chemical supply.
  5. Measure out enough suction line to reach the chemical supply and cut to the required length. Cutting the suction line slightly longer than required is recommended as it will leave room to attach to the suction lance. NOTE: Keep all hoses off the ground and out of wthe alkway to avoid potential tripping hazards.
  6. Slide the SSC12 screw band onto the open end of the suction line and push the suction line onto the HBEL1212 hose barb. Secure by tightening the SSC12 screw band. Open the HV60 ball valve before operating unit.
  7. Screw the AP25-E quick connector into the AF14 air filter on the left side of the unit.
  8. Mount the SHF1814 shelf; the AFS-1E/AFS-1E-UPB unit will sit on this shelf. Using a level, mark the (4) holes for mounting the shelf and drill using the included BIT38M 3/8 in. masonry bit. Insert the orange WMS516A wall anchors and secure the shelf using (4) WMS516X2 lag screws. Note: Use 13 mm socket or wrench for lag screws.
  9. Set the AFS-1E/AFS-1E-UPB unit on the shelf and mark the (2) mounting holes that go through the back of the unit.
  10. Remove the AFS-1E/AFS-1E-UPB unit and drill the (2) marked holes with the BIT38M 3/8 in. masonry bit. Insert the orange WMS516A wall anchors.
  11. Set the AFS-1E/AFS-1E-UPB unit back on the shelf and secure the unit to the wall using (2) WMS516X4 long lag screws and (2) FWLG516 washers. These go through the two holes in the AFS-1E/AFS-1E-UPB unit. Note: Use 13 mm socket or wrench for lag screws.
  12. Align the L325-BRKT bracket with the two empty threaded inserts on top of the unit. Hold the bracket in place, and mark the location of the two mounting holes on the wall. Set the L325-BRKT bracket aside, then drill the mounting holes and insert orange WMS516A wall anchors.
  13. Attach the L325-BRKT bracket to the two empty threaded inserts on top of the AFS-1E/AFS-1E-UPB unit using (2) AS1 screws. This bracket will help secure the unit to the wall.
  14. Secure the L325-BRKT bracket using (2) WMS516X2 lag screws. Use this bracket to pull the unit flush against the wall.

SETUP INSTRUCTIONS FOR MODEL AFS-1E-UPB

  1. Orient the USPK-UBRKT so the flange of the USPK-UBRKT is on the opposite side as the suction nipple on the User-Pack. Note: the suction nipple must be on the same side for all User-Packs intended to be filled. User-Packs with suction nipples matched up to the flange of the USPK-UBRKT will not fit and the system will not turn on.
  2. Connect compressed air to the AFS-1E-UPB.
  3. Set the System Pressure regulator (on the right) between 60-80 PSI (4.1 to 5.6 bar). Turn dial below gauge clockwise to increase pressure.
  4. Continue with “SETTING THE FILL LEVEL.”

SETUP INSTRUCTIONS FOR MODEL AFS-1E

  1. Move the PV-WHKR-VLV-ADJBRKT up or down to fit the desired jug. When properly inserted, the jug should contact the needle of PV-WHKR-VLV and bend it slightly.
  2. Tighten down the (2) AS1 screws.
  3. Connect compressed air to the AFS-1E.
  4. Set the System Pressure regulator (on the right) between 60-80 PSI (4.1 to 5.6 bar). Turn dial below gauge clockwise to increase pressure.
  5. Continue with “SETTING THE FILL LEVEL.”

SETTING THE FILL LEVEL

  1. Place the jerry can / User in the AFS-1E/AFS-1E-UPB with the neck/cap next to the chemical hose.
  2. Note the appropriate fill height for the can / User-Pack.
  3. Loosen the CGRP14K cord grip and slide the bottom of the level sensor tube 1 inch (25mm) below the desired fill level. NOTE: The LST14 level sensing tube shuts off the system when it detects back pressure. The end of the tube must be submerged before generating back pressure.
  4. Retighten the CGRP14K cord grip with a wrench.
  5. Set the Level Sensing regulator (Left gauge) between 0.5 to 2 PSI. Turn the dial below the gauge counterclockwise to increase pressure.
  6. Test the system by filling the can / User-Pack with water.
    • NOTE: The system will consistently fill the same can / User-Pack to this preset level.
  7. Perform a test with the chemical to ensure that the LST14 level sensing tube is calibrated correctly with the chemical.

OPERATION INSTRUCTIONS

Always wear the appropriate personal protective equipment (PPE) when operating the AFS-1E/AFS-1E-UPB.

  1. Use the handle to guide the fill tube into the can / User-Pack opening and place the designated can / User-Pack on to rack.
  2. Ensure that can / User-Pack is properly located on the rack. The\ can / User-Pack must push down on the whisker valve to activate the system.
  3. Close the door and secure the latch.
  4. Turn the black “Power” switch to the “ I ” position and the system will be ready to be activated.
  5. Press the green “Start” button to fill the can / User-Pack to the designated level. The system will shut off automatically at the designated fill level.
  6. The red “E-Stop” button can be used to shut off the system immediately if necessary.
  7. Turn the black “Power” switch to the “ O ” position.
  8. Open the door. Hold the handle of the fill tube while gently removing the can / User-Pack from the rack.
  9. Due to chemical residue left on fill tube, avoid touching the fill tube.

NOTICE:

  • If the door is opened while the system is filling, the system will shut off.
  • The system will not turn on unless a can / User-Pack is properly positioned on the rack.
  • if a can / User-Pack is placed with a liquid level that is higher than the set fill level, the unit will not activated when the “Start” button is pushed.
  • It is recommended to rinse the system thoroughly with water once a week.

REPLACE EMPTY CHEMICAL SUPPLY

Always wear the appropriate personal protective equipment (PPE) when operating the AFS-1E/AFS-1E-UPB.

  1. Make sure power is in “ O “ position.
  2. Close HV60 ball valve.
  3. Remove suction lance from empty chemical supply and place in full chemical supply. NOTICE: Avoid coming to contact with chemicals.
  4. Correctly position full chemical supply.
  5. Open HV60 ball valve.

TO CHANGE CHEMICAL PRODUCT

Always wear the appropriate personal protective equipment when changing chemical products.

NOTE: It is not recommended to change product. The machine is intended to be use with one product only. In case of product change followthe below instructions.

  1. Remove the suction lance from the chemical supply.
  2. Using a suitable can / User-Pack, rinse the system thoroughly with water.
  3. Place the suction lance in the new chemical drum.
  4. Cycle the system until any remaining water is flushed out and only the chosen chemical is dispensed.
  5. Verify the fill level is correct.

Maintenance

Always wear appropriate personal protective equipment (PPE) when servicing unit. There may be chemical in the system. Flush the system with sufficient water to clear out remaining chemicals.

Practice proper Preventive Maintenance:

  • Rinse and clean drip pan weekly.
  • Replace the H12B and H12CB hose every 6 months if the chemical being transferred contains one or more of the following ingredients:
    • NaOH
    • KOH
    • H2O2
    • HNO3
    • H2SO4
    • Acetic acid
    • Peracetic acid
    • Peroxyoctanoic acid
    • Surfactants

Please see the Product Data Sheet from your chemical supplier to identify ingredients in product or ask your Ecolab application specialist.

TROUBLESHOOTING

Always wear appropriate personal protective equipment (PPE) when troubleshooting unit.

Unit does not begin fill process

  1. Check that the can / User-pack is placed firmly on top of the whisker valve. If the can / User-pack is not holding the whisker valve open the system will not run. If the valve has been bent it may need to be straightened by bending it back into place so that the can / User-pack can properly contact the whisker valve.
  2. Check the door. The system will not run if the door is not properly closed. There is a secondary air switch that needs to be contacted for the proper operation of the unit.
  3. With the door closed, switch the filling station on. Undo the thumb screws on the control box to access the regulators. The gauge on the right should read 60 to 80 PSI (4.1 to 5.6 bar). If no pressure is indicated, turn the system off and proceed to No Pressure Detected, below. If the pressure is correct, skip to Pressure Detected.

No Pressure Detected

  1. Adjust the regulator below the gauge on the right.
  2. Check the Air In connections. Open the door and check the lines running to the door switch and from the door switch to the control box. This line is labeled “AIR IN” at the control box.
  3. Check your compressed air system.

Pressure Detected

  1. Check if the door switch can be depressed. It should move when pressed and spring back to its resting position when released.
  2. Make sure the door switch is fully depressed when the door is in the closed position. If the bracket is bent the switch may not contact the door and the bracket will have to be readjusted to contact the door when the door is in the closed position.
  3. With the system off, open the control box and verify that all the tubes are correctly and securely connected. Also, check the air connection behind the whisker valve and the air connection from the control box to the pump. Make sure air lines are not kinked.
  4. Verify that the LST14 level sensing tube is not plugged or creased. The PSI on the level sensor regulator (located in the control box) should be set to 0.5 to 2 PSI. If the regulator is set too low the system will not dispense chemical.

Can / User-pack is not being filled completely

  1. Check the height of the LST14 level sensing tube.
  2. Check the chemical levels.

Can / User-pack is being overfilled

  1. Make sure the LST14 level sensing tube is inside the can/user pack. If it is outside the can / User-pack it will not detect the level.
  2. 2. Check the height of the LST14 level sensing tube. It should be about 1 in (2.5 cm) below the full line of the can / User-pack when the fill tube is in the can / user pack.
  3. 3. Check the left gauge inside the control box. It should be set to 0.5 to 2 PSI. If it is set above 2 PSI the system will not shut off properly.

Air passes through the pump, but does not dispense chemical

  1. Verify that the HV60 ball valve, located at the top of the suction lance, is in the open position.
  2. The pump must be replaced.

To change pump

Always wear appropriate personal protective equipment (PPE) when changing pump. There may be chemicals still in the system.

  1. Rinse the system thoroughly with water to clear out the remaining chemicals.
  2. Turn system OFF.
  3. Disconnect the red air line from the pump.
  4. Disconnect the suction line from the pump.
  5. Undo the 3 screws along the bottom edge of the black plate.
  6. Carefully remove the plate by pulling the bottom edge out, then pulling down.
  7. Disconnect the chemical dispensing line from the pump.
  8. Remove the 4 screws holding the pump to the plate.
  9. Install replacement pump by following steps 3 to 8 in reverse.

MODEL

ECOLAB-AFS-1E-Automated-Filling-Station-FIG (3)

ASSEMBLY

DOOR ASSEMBLY

BACK PLATE

BACK PLATE

ECOLAB-AFS-1E-Automated-Filling-Station-FIG (5)ECOLAB-AFS-1E-Automated-Filling-Station-FIG (6)

OVERVIEW

CONTROL BOX: FRONT COVER VIEW

ECOLAB-AFS-1E-Automated-Filling-Station-FIG (7)

CONTROL BOX: INSIDE VIEW

ECOLAB-AFS-1E-Automated-Filling-Station-FIG (8)

ASSEMBLY

ECOLAB-AFS-1E-Automated-Filling-Station-FIG (9)ECOLAB-AFS-1E-Automated-Filling-Station-FIG (10)

MOUNTING HARDWARE

ECOLAB-AFS-1E-Automated-Filling-Station-FIG (11)

ECOLAB-AFS-1E-Automated-Filling-Station-FIG (12)

  1. AF14
  2. B4WV18 (1) + AIRBTNGRN assembly
  3. B4WV18 (2) + PV-TBNC-18 assembly
  4. AFS-CTRL-BRD
  5. BSV18 (1)
  6. PV-BNC-18-GR
  7. PV-BNC-18-RD
  8. BSV18 (2)
  9. PV-WHKR-VLV
  10. Level Sensor Tube
  11. P56K
  12. Level Sensor Regulator
  13. System Pressure Regulator
  14. Level Sensor Gauge
  15. System Pressure Gauge
  16. PV-1
  17. PV-2P
  18. Limit Valve
  19. Level Sensor

PARTS

ECOLAB-AFS-1E-Automated-Filling-Station-FIG (13)ECOLAB-AFS-1E-Automated-Filling-Station-FIG (14

DESCRIPTION

ITEM NUMBER DESCRIPTION
AF-14 AIR FILTER – 1/4 FPT -25 MICRON FILTER
AFS-BODYBL BASE FOR AFS UNITS
AFS-CTRL-BRD CONTROL BOARD FOR AFS
AFS-DOORBL BLUE DOOR FOR AFS UNITS
AFS-GRATE AFS DRIP PAN GRATE [REV 1]
AFS-PAN COLLECTION PAN FOR AFS UNITS
AFS-WINDOW 28×15 3/16 CLEAR PVC
AIRBTNGN AIR PUSH BUTTON GREEN
AP25-E AIR PLUG (EUR) – 1/4 MPT X PLUG
AS1 1/4-20 X 1/2 PHIL TRUSS M/S, S/S
B10321 10-32 X 1 PHIL TRUSS MACH SCR 18-8
B103225 10-32 X 1/4in PHIL MACH SCREW 18-8
B103234 10-32 X 3/4 PHIL TRUSS MACH SCR 18-8
B38162 HEX HEAD BOLT 3/8-16X2 18-8SS
B4WV18 BRASS 4-WAY VALVE 1/8 INCH PORTS
B8X58 8-15 X 5/8 inch PHIL FLAT TY-A 316 S.S.
BIT38M 3/8 X 6 MASONRY DRILL BIT
BSV18 BRASS SHUTTLE VALVE 1/8 INCH PORTS
CGRP14K CORD GRIP 1/4 INCH KYNAR
CV1438T-3 426-4MGB-F, 3 LB HASTELLOY
EC18 OETIKER CLAMP – 11.3
FB1187 FIBOX 11X7.5X7.1
FT-HNDL STAINLESS FILL TUBE HANDLE [REV 1]
FW14 1/4 X 5/8 OD FLAT WASHER 18-8 PLN
FW38X78 FLAT WASHER 3/8X7/8 X.050
FWLG14 .569 ID X 1.28 OD X .08 THICK FLAT WASHER SS 18-8
FWLG516 5/16” ID Stainless fender washer, 1.5” OD 18-8SS
FWP12 7/8 ID X 1.5 OD X 0.05 THK SSFW
FWP78 7/8in BY .137 BY 1 1/4in FLATWASHER 18-8 PLN
H12B 1/2in BLUE PLIOVIC HOSE – Available per ft.
H12-BRKT AFS FILL HOSE BRACKET [REV 1]
H12CB 1/2 IN (ID) CLEARBRAID RF SERIES – Available per ft.
H14B 1/4 in BLUE PLIOVIC HOSE – Available per ft.
H14KT 1/4 IN Kynar PVDF TUBING – Available per ft.
H14TU Translucent Green Polyurethane .25ODx.17ID – Available per ft.
HB1412 1/4in MPT X 1/2in HOSE BARB
HBBL103217 MINI HOSE BARB – 10-32X.17 EL
HBSS1212 STAINLESS HOSE BARB 1/2 X 1/2
HBSS14P STAINLESS STEEL HOSE BARB 1/4 INCH – FOR P56
HBSSEL1212 304 S.S. 1/2in MPT BY 1/2 in H.B. ELBOW
HV60 1/2in STAINLESS BALL VALVE – w/ WELDED NUT
ITEM NUMBER DESCRIPTION
L325-BRKT STAINLESS STEEL EL BRACKET WITH FOUR HOLES [REV 1]
LN14 1/4-20 NE NYL INS LOCKNUT 18-8 PLN
P56K 5700 PUMP WITH KALREZ SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
PL-AFS AFS Plate, ¼ in black PP
PV-1 PULSE VALVE #10-32 OPEN 3-WAY VALVE
PV-BNC-GR-18 PNEUMATIC PUSH-BUTTON – GREEN – 1/8 FPT- 3 PORT NORMALLY CLOSED
PV-BNC-RD-18 PNEUMATIC PUSH-BUTTON – RED – 1/8 FPT- 3 PORT NORMALLY CLOSED
PVC-DR-PIN-3/8 PVC DOOR PIN 3/8 DIAMETER X 1 9/16 INCHES LONG
PV-TBNC-18 PNEUMATIC TWIST SELECTOR BUTTON – 1/8 FPT- 3 PORT NORMALLY CLOSED
PV-TBNC-18A ADAPTER FOR CLIPPARD ACTUATOR
PV-WHKR-VLV PNEUMATIC WHISKER VALVE – 1032 FEM PORT – BRASS – AFS JUG SENSOR
PW1248-120 1/2in BLACK POLY PRO X 48in – SCH.120 – 1/2in MPTOE &

1/4in FPTOE

PW12F 1/2 INCH X 1/2 INCH POLYPRO SCHE 120 BLACK FPTX FPT
QF103214 MALE CONNECTOR #10-32 BY 1/4IN TUBE PUSH IN
QF14P MALE CON. 1/4in TUBE X 1/4in MPT POLYPROPYLENE
QF18 MALE CON. 1/4in X 1/8in MPT BRASS
QF1814 MALE CONNECTOR 1/8in NPT BY 1/4in TUBE POLYPROPYLENE
QFA1414K 1/4in TUBE X 1/4in HOSE STEM – KYNAR
QFEL1814 FIXED ELBOW 1/8in MPT X 1/4in TUBE – POLYPROPYLENE
QFU14 UNION CON. 1/4in TUBE – POLYPROPYLENE
S1034FHL 10 X 3/4 PHIL FLAT HI-LO THRD SCREW 18-8
S142034 1/4-20 X 3/4 PHIL TRUSS M/S 18-8
SEL12F S.S. ELBOW 1/2in FPT X 1/2in FPT
SHF1814 Shelf 18 X 14 inch for Wall mounting AFS-1E [REV 1]
SS1B2WV-BRKT BRACKET FOR TWO WAY BRASS AIR VALVE [REV 1]
SSA14 SS304 MALE/FEMALE ADAPTOR 1/4 NPT X 1/4 NPT
SSC12 WORM GEAR CLAMP, S/S (.31-.91)
SSE12 STREET ELBOW 1/2in – 316 S.S.
SSK2H STAINLESS STEEL KEEPER – 2 HOLE MOUNTING
SSL2.25 STAINLESS STEEL LATCH – 2.25in DRAW – ELECTROPOLISHED

– PADLOCKING

TLCLAMP12 Tefzel Loop Clamp for 1/2” Outside Diameter
USPK-BRC BRACE FOR USER PACK AFS-1-E [REV 1]
USPK-SHF UserPack Shelf for AFS-1E [REV 1]
USPK-UBRKT U-BRACKET FOR USER PACK AFS-1-E [REV 1]
WMS516A concrete wall anchor, 3/8 in. drill size for 5/16 in. screws,

2.5 in. long

WMS516X2 5/16 X 2 IN stainless lag bolt, w/hex head 18-8SS
WMS516X4 WALL MOUNT SCREWS 5/16 X 4

CONTACT INFORMATION

Ecolab Austria

  • Erdbergstrasse 29
  • 1030 Wien
  • Telephone: 43 1 715 25 50
  • Fax: 43 1 715 25 50 2850

Ecolab Germany

  • Ecolab Deutschland GmbH
  • Ecolab-Allee 1
  • 40789 Monheim am Rhein
  • Telephone: 49 2 173 599 0

Ecolab United Kingdom

  • David Murray John Building
  • Swindon, Wiltshire
  • SN1 1NH
  • Telephone: 44 1793 51 12 21
  • Fax: 44 1793 61 85 52

Ecolab Turkey

  • Altaycesme Mah.
  • Toygun Sok. No:1
  • 34843 Maltepe-Istanbul
  • Telephone: 90 216 441 20 30
  • Fax: 90 216 441 14 35

Ecolab Netherlands

  • Iepenhoeve 7
  • 3438 MR Nieuwegein
  • Netherlands
  • Telephone: 31 30 6082 222
  • Fax: 31 30 6082 228

Ecolab Ireland

  • La Vallee House
  • Upper Dargle Road
  • Bray, Co. Wicklow
  • Telephone: 353 1 2763500
  • Fax: 353 1 2869298