Safety Instructions
Disclaimer

Before using this product, please read and fully understand this document and all related documents of this product. After reading this document, please keep it well for future reference. Failure to properly operate this product could cause serious injury to yourself or others, or damage to this product and other property. By using this product, you are deemed to have understood, acknowledged and accepted all terms and contents of this document. The user undertakes to be responsible for his/her actions and all consequences arising therefrom. EcoFlow is not liable for all losses caused by the user’s failure to use this product according to the disclaimer and safety instructions.

EcoFlow reserves the right of final interpretation of this document and all related documents of this product where permitted by laws and regulations. These documents are subject to update, revision or termination from time to time without prior notice, please visit EcoFlow website for the latest product information.

I. Installation
  1. The installation and operating environment must meet relevant international, national, and local standards, and are in accordance with the local laws and regulations.
  2. Ensure the charge point is protected against lightning and heavy rain.
  3. Keep the product away from explosive or flammable materials, chemicals, vapors and other hazardous objects.
  4. The mounting structure where the equipment is installed must be fire resistant. Do not install the equipment on flammable building materials.
  5. Ensure that the installation surface is solid enough to bear the weight of the equipment. 
  6. Reserve sufficient clearance around equipment to ensure sufficient space for installation and heat dissipation. 
  7. Adaptors or conversion adapters are not allowed to be used. Cord extension sets are not allowed to be used.
II. Wiring
  1. Before connecting to the power source, make sure that the main circuit is disconnected. Wear insulated protective equipment when operating, otherwise serious personal injury can occur.
III. Use and Disposal
  1. Do not touch the socket pin when the unit is powered on. 
  2. Do not use the charge point if it shows any visible product damage such as cracks, abrasions, bare leakage, and other visible defects. Contact a qualified technician immediately at the first sign of such damages. 
  3. Do not attempt to disassemble, repair or refit the charge point. If necessary, please contact the qualified technician. Improper operation will result in device damage, electric leakage and other hazards.
  4. In case any abnormal condition happens, please turn off incoming power supplies immediately.
  5. During charging, do not drive the EV. Charge only when the EV is stationary. For hybrid cars, charge only when the engine is switched off. 
  6. Keep children away from the charge point.
  7. Keep the charge point socket clean and dry. If it gets dirty, please wipe it with a clean, dry cloth. 
  8. Our packaging materials are environmentally friendly and can be recycled. Please put the packaging in applicable containers to recycle it. Do not dispose of this device with household waste. It should be taken to a suitable facility for recycling electrical and electronic devices. For more detailed information about recycling of this device, please contact your local city/town council office or your household waste disposal service. 
Technical Specifications
Model EF-PP-H01-1
Input & Output specifications
AC input (three-phase) 400V~16A per phase (L1/L2/L3/N/PE)
AC output (three-phase) 400V~16A per phase, max. 11kW, mode 3
Rated frequency 50 Hz
Approved grid configurations TN, TT
RCD  TypeA+6mA DC detection
Communication
Wi-Fi (2.4G) Frequency range: 2400 ~ 2484.5 MHz
Maximum output power: 20 dBm
Bluetooth Frequency range: 2412 ~ 2480 MHz
Maximum output power: 10 dBm
Environment requirement
Ambient temperature for storage -40ºC to +70ºC
Ambient temperature for operation -30ºC to +50ºC
Relative humidity (condensing) 5% to 95%, condensation-free
Basic information
Net weight 3.3 kg
Dimensions Charging box: 283x178x99 mm
Charging cable: 5 m
Altitude ≤ 2000 m
Pollution Degree 3
IP rating IP65
Compliance standard EN61851-1
EN61851-21-2
Tools & Accessories Checklist
Installation

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - a1                      ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - a2
Hammer drill                                Screwdriver
Φ6mm                                                PH2

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - a3                 ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - a4
Electrical screwdriver                        Mallet
PH2

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - a5                    ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - a6
Measuring tape                                Marker

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - a7                     ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - a8
Level                      Protective equipment Gloves & googles

Power Source Wiring

a

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - b1
Three-phase/single-phase AC circuit breaker

b

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - b2
L1 (+L2+L3)+ N+PE AC cables

c

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - b3        ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - b4         ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - b5
Multimeter                 Wire stripper        Tube type crimp tool

a. Rated voltage >230V per phase, 400V total (three-phase)Rated current >16A per phase
With overload protection and short-circuit protection

b. Cross-section area ≤6 mm²
Outer ring girth ≤17.5 mm
Capable of carrying currents of 16A and above per cable

c. AC voltage measurement range ≥ 400V

Communication Wiring(optional)

a

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - c1                    ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - c2
RJ45 network cable            RJ45 crimp tool (8P)

b

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - c3
Tube type wire terminals*2

a. CAT 5 or higher, in accordance with T568B, length ≤15 m

b. 0.2 mm²

Product Overview

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d1

  1. Indicator light
  2. Main charging box
  3. Cable winder
  4. Charging cable
  5. Cable Cover
  6. Communication port
  7. Power input port
What’s in the Box
(A) ×1

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d2

Charging Box

(B) ×1

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d3

Cable Winder

(C) ×1

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d4

Mark-off Template

(D1) ×8

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d5M4
32mm

(D2) ×8

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d6ø6mm
30mm

(E) ×1

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d7

Power Input Connectors

Wall Installation Kits

(F) ×1

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d8

RJ45 Waterproof Connectors

(G) ×6

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d9

Tube Type Wire Terminals

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - d10

Manuals & Warranty Card

Installation Guide
Pre-installation Requirements
  • It is recommended that the installation position is close to both the parking spot (car charging port) and distribution box to ensure that the cable is not stretched by force; 
  • There should be enough storage space between the cable winder and the charging box, and it meets the height above ground requirement of this product.
Ground Clearance

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - e1

CAUTION

Certified RCBO should be installed upstream close to the charging station, All these protection devices shall be chosen with appropriated technical specification, working voltage ≥ charging station working voltage, working current ≥ charging station working current, Ingress Protection (IP) ≥ IP54 or installed inside IP54 protection box for outdoor use.

Wall Installation
I. Charging Box

On Concrete Wall

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - e2

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - e3
Exposed Length

NOTICE

  • When installed on a wooden wall, drill the bolts directly into the wall without using expansion bolts.
II. Cable Winder

On Concrete Wall

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - e4

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - e5

NOTICE

  • Please lock the bolt at the bottom after installation and wiring.
Wiring Guide
  • Please make sure that the wires, circuit breakers and other accessories used for wiring are undamaged, fit the product parameters and specifications, and comply with the relevant standards and regulations of your country or region. 
  • Before installing this product, it is important to measure the present load of your home electrical circuit and ensure that it can carry the operating current of this product, otherwise the circuit will be tripped.
  • After powering on the product, it will initiate device wiring testing. To confirm that the self-check process has been successful, verify that there are no abnormal indicator light effects (refer to the section on Indicator Light for more information).
I. Power Input Port

Three-phase: L1 ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f1    Single-phase: L1 ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f1
L2 ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f2                                                N ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f4
L3 ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f3                                              PE ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f5
N ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f4
PE ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f5

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f6    ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f7

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f9

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - f10

II. Communication Port (Optional)

NOTICE

  • In solar storage charging, standalone operation (solar charging or load balancing) scenarios, PowerPulse needs to communicate with external devices or a smart meter.

Connecting to PowerPulse

(1)

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g1 ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g2 ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g3

(2)

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g4 ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g5

Standalone Operation (communicate with smart meter)

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g6

  1. PowerPulse
  2. Breaker
  3. Smart meter
  4. Utility Meter
  5. Fuse
  6. Grid

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g7

sold separately

  1. GRID
  2. LOAD
  • Set the baud rate to 2.4k and parity check to Even referring to the manual.

Solar storage charging (communicate with PowerOcean)

Ethernet

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g8

a) COM Terminal

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - QR Code 3
PowerOcean
User Manual


Wi-Fi

ECOFLOW - WiFi

Accessing the same wireless network

  • Go to PowerOcean ECOFLOW - Device Settings Device Settings to add device on system component page.
III. System Power-On

NOTICE

  • To energize the PowerPulse, turn ON the branch breaker. The product is ready to use after wiring test completes.

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - g9

  1. Repeat
  2. Wiring test status
Indicator Light

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h1 Off    ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h2 Solid   ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h3 Breathing   ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h4 Flashing

Indicator status

Indications
White light

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h2 (1s) – ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h1 (3s), repeat

Standby

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h2 (1s) – ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h1 (1s), repeat

Charging cable plugged in, please power on in EcoFlow App
ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h3 Charging
ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h2 Vehicle/Battery fully charged

AC input power insufficient, charging suspended

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h2 (0.1s) – ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h1 (0.1s) repeat

Firmware upgrade
Orange light ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h4

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox - h2

Error occurs. Please refer to User Manual for more information, or check it on the device page of EcoFlow App

ECOFLOW - PAP 22Raccolta carta

© 2023 EcoFlow Inc. All rights reserved.

Documents / Resources

ECOFLOW EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox [pdf] Installation Guide
EF-PP-H01-1 Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox, EF-PP-H01-1, Type 2 Mode 3 16 A 11 kW Power Pulse Wallbox, A 11 kW Power Pulse Wallbox, Power Pulse Wallbox, Pulse Wallbox

References

Leave a comment

Your email address will not be published. Required fields are marked *