ecler-logo

ecler HADA Series Networkable Amplifiers

ecler-HADA-Series-Networkable-Amplifiers-product

Specifications

  • Product Name: HADA Series Networkable Amplifiers
  • Type: Digital Amplifiers
  • Model Number: 50-0439-0105

Product Using Instructions

Description & Features

The HADA Series Networkable Amplifiers are digital amplifiers designed for high-quality audio playback. They offer advanced features and connectivity options for versatile use in various audio setups.

Panel Functions

  • The panel functions include various controls and indicators for easy operation and monitoring of the amplifier. Features like Out Configurations and Remote Volume control enhance user experience.

Installation & Connection

  • Proper installation and connection are crucial for optimal performance. Follow the provided guidelines to ensure the amplifier is set up correctly and connected to the audio sources and output devices.

Start-up & Operation

  • After installation, follow the start-up procedures to power on the amplifier and configure it for operation. The user manual provides step-by-step instructions for a smooth start-up process.

Technical Data

  • Refer to the technical data section for detailed specifications, including power ratings, impedance levels, and other technical information relevant to the amplifier’s performance.

Product Usage Instructions

Installation & Connection

Follow these steps to install and connect the HADA Series Networkable Amplifier:

  1. Choose a suitable location for the amplifier with proper ventilation.
  2. Connect the amplifier to power using the provided power cord.
  3. Connect audio input sources to the corresponding inputs on the amplifier.
  4. Connect output devices such as speakers to the amplifier’s output terminals.

Start-up & Operation

Once connected, follow these steps to start-up and operate the amplifier:

  1. Power on the amplifier using the power button.
  2. Adjust volume levels and settings as needed using the controls on the panel.
  3. Refer to the user manual for advanced operation modes and settings.

FAQ

  • Q: How do I update the firmware of the amplifier?
    • A: To update the firmware, connect the amplifier to a PC using the provided USB cable and follow the instructions in the user manual for firmware updates.
  • Q: Can I control the amplifier remotely?
    • A: Yes, you can control certain functions of the amplifier remotely using TELNET Control. Refer to the user manual for detailed instructions on remote operation.

“`

PRECAUTIONS

1.1 Important Notice

Ctrl. HW SW

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS

INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

The flashing light with an arrowhead symbol inside an equilateral triangle on it is intended to alert the user of the presence of non-insulated “dangerous voltage” within the enclosure, which might be of sufficient magnitude to pose a risk of electric shock to users. The exclamation mark within an equilateral triangle is intended to alert the user of the requirement for important operating and maintenance (servicing), for which instructions may be found in the literature accompanying the appliance.
WARNING (If applicable): The terminals marked with symbol ” ” may be of sufficient
magnitude to pose a risk of electric shock. The external wiring connected to terminals requires installation by a technician, or the use of ready-made leads or cords.
WARNING: To prevent fire or shock hazard, do not expose this equipment to rain or humidity.
WARNING: A device with Class I manufacturing ought to be connected to a mains socket
outlet with a protective earthing connection.
WARNING: Ecler products have a long lifetime of more than 10 years. This product
must never be discarded as unsorted urban waste, but must be taken to the nearest electrical and electronic waste treatment centre.
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC Rules. Such limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference in radio communications. Operation of this equipment in a residential area might cause harmful interference, in which case, the user will be required to correct the interference at his own expense.
4

Groups TELNET Control

HADA DSP MANAGER & First Steps

Automatic

1.2 Key Safety Directions

1. Read the following directions. 2. Keep the following directions. 3. Heed all warnings. 4. Follow all directions. 5. Do not use this device in proximity to
water. 6. Clean only with a dry cloth. 7. Do not block any ventilation
openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other devices (including amplifiers) that may release heat. 9. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades, being one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, contact a qualified electrician for a replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched, particularly at the plugs, convenience receptacles, and at the point of exit from the device.

11. Only use attachments/accessories specified by the manufacturer.
12. Unplug the device during lightening sorts or when unused for long periods of time.
13. Refer all servicing to qualified personnel. Servicing is required when the device has been damaged in any way, such as power supply cord or plug damage, liquid spillage or objects onto the device, the device has been exposed to rain or humidity, does not operate normally, or has been dropped.
14. Disconnecting from mains: When switching off the POWER switch, all the functions and light indicators of the unit will be stopped, but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket, therefore, it should always remain easily accessible
15. Equipment is connected to a socketoutlet with an earthing connection by means of a power cord.
16. The marking information is located at the bottom of the unit.
17. The device shall not be exposed to dripping or splashing liquids, and no liquid-filled objects, such as a filled up glass, shall be placed on top of the device.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Login Main Screen

Device

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

1.3 Cleaning Directions
Clean the unit with a soft, dry clean cloth or slightly wet with water and neutral liquid soap only, then dry it with a clean cloth. Be careful that water never gets into the unit through any hole. Never use alcohol, benzine, solvents or abrasive substances to clean this unit.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be caused to people, animal, or objects due to failure to comply with the warnings above.
5

HADA DSP MANAGER & First Steps

Automatic

WARRANTY & ENVIRONMENT

Thank you for choosing Ecler Hada Series! We greatly value your trust.
It is VERY IMPORTANT to carefully read this manual and to fully understand its contents before any connecting takes place in order to make the best use of this equipment, as well as to get the best performance from it. To ensure optimal operation of this device, we strongly recommend that its maintenance be carried out by our authorised Technical Services. All ECLER products are covered by warranty, please refer to www.ecler.com or the warranty card included with this product for the period of validity and conditions.

WARRANTY & ENVIRONMENT

PRECAUTIONS

Updates

Ctrl. HW SW

Connection with PC

PACKAGE CONTENTS

DESCRIPTION & FEATURES

Ecler is truly committed with the environment and planet sustainability, energy saving and CO2 emission reduction. Recycling materials and using non-contaminant components are also top priorities in our green crusade.
Ecler has deeply evaluated and analyzed the environmental impacts of all the processes involved in the production of this product, including packaging, and has alleviated, reduced and/or compensated for them.

Login Main Screen

Configuration

Admin Mode

3. PACKAGE CONTENTS
· 1 unit of one of the HADA Series models. · EU mains cords. · Euroblock Connectors (inputs /outputs) · Desktop feet, rack 19″ installation hardware. · First Steps Guide. · Warranty card.

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

6

HADA DSP MANAGER & First Steps

Automatic

4. DESCRIPTION & FEATURES
HADA Series is a family of digital amplifiers, with different power levels: HADA-4B150 with 125W, HADA-4B250 with 250W, HADA-4B400 with 400W, HADA-4B500 with 500W and HADA-4B750 with 750W.
All the models include 4 amplified channels that support Hi-Z and Low-Z loads down to 2, 2.7 or 4 ohms, depending on the model.
A powerful DSP allows to manage the routing and the processing of the inputs and outputs through the HADA DSP Manager Software. Routing functionality includes a matrix mixer for selecting which input channels to allocate to the outputs. Processing includes 10-band EQ, HP and LP filters, limiters, multi-band compressors, delay and factory and end-user configurable presets.
All models include a remote output volume control via the front potentiometers. It is also possible to connect external potentiometers in the rear panel, for the remote volume control of the outputs. Via an external contact, it is also possible to perform a general mute of the outputs, for emergency functions or integration purposes.
Another control option is network control via TCP/IP which allows to control the amplifier from third party control systems through customized user interfaces.

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Connection with PC

Updates

Ctrl. HW SW

Login Main Screen

DESCRIPTION & FEATURES

Configuration

4.1 Main Features
· 4 amplified outputs in Lo-Z or 2 amplified outputs in Hi-Z.
· 4 balanced analogue inputs on Euroblock connectors.
· 4 GPI for remote volume control

· Internal matrix mixer and signal processing.
· HADA DSP Manager software for device configuration and control
· Third party TCP/IP control.

Device

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

7

5. PANEL FUNCTIONS 5.1 Front Panel

Ctrl. HW SW

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

ecler-HADA-Series-Networkable-Amplifiers-fig-1

1. ON/Standby Button: the equipment is switched on by default just switching to ON the rear power switch. · When the ON LED of the front panel is lit in white, the device is operational. · To enter in standby mode, press and hold the ON button of the front panel until all LEDs on the front panel blink once. The prot. LED (red) will illuminate together with the ON LED (white) to indicate that standby mode is active. · To exit standby mode, repeat the process.
2. Control knobs (1-4): Each front panel LEVEL knob allows to control the correspondent amplified audio outputs. When two channels are bridged, potentiometer 1 or 3 will be the one taking control of the bridged channel pair, and 2 or 4 will be then inactive. For further information see HADA DSP Manager chapter.
The front panel knobs can be disabled by holding down the ON button until all front panel LEDs flash three times. The same procedure will enable them again.
3. Signal indicator LED: indicates signal presence in the amplification output. These indicators light up in white colour when the input signal exceeds -36dBV threshold.
4. Clip indicator LED: lights up in red colour when the input signal exceeds +18dBV. 5. Limit indicator LED: lights up in red colour when the output signal reaches the limit set
by software in the output limiter section. In case that any limiters are set, the LED lights up when the maximum power is reached.
Depending by the output mode configuration (Dual or Bridge Mono) and the output settings (2 Ohm, 2.7 Ohm, 4 Ohm, 8 Ohm, 8 Ohm Bridge, 70V or 100V) the behaviour of the limit LED changes. Please ensure that the output configuration matches with the load in use.
8

Groups TELNET Control

HADA DSP MANAGER & First Steps

6. Mute indicator LED: lights up in white colour when the amplified output is muted.
7. Prot. indicator LED: lights up in red colour when any protection of the power module is active (along with the mute LEDs of the channels that are failing), or when the standby mode is active (along with the ON LED).
8. Thermal indicator LED: lights up in red colour when temperature limiter is activated. 9. Ext. Mute LED: lights up in white colour when the external mute is active. 10. Data indicator LED: lights up in white colour to indicate that the software HADA DSP
Manager is online. 11. On indicator LED: in white colour indicates power energy activity.

PRECAUTIONS

Updates

Ctrl. HW SW

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

5.2 Rear Panel

Automatic

Connection with PC

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

ecler-HADA-Series-Networkable-Amplifiers-fig-2

1. Mains socket base 2. Power switch 3. External mute port 4. Amplified outputs, OUT 1-4, 2-pin Euroblock 5. Remote Volume ports REMOTE 1-4, 6-pin Euroblock 6. Analogue inputs, IN 1-4, 3-pin Euroblock, balanced. 7. Reset button 8. RJ-45 ethernet network port, NET, RJ-45
9

HADA DSP MANAGER & First Steps

Automatic

6. INSTALL & CONNECT
The equipment must be correctly grounded (ground resistance, Rg = 30 Ohm or less). The environment must be dry and dustless. Do not expose the unit to rain or water splashes, and do not place liquid containers or incandescent objects like candles on top of the unit.
Do not obstruct the ventilation grilles with any kind of material. If the device requires any intervention and/or connection/disconnection, it must be first powered off.
Do not handle the speaker output terminals with your device turned on, there are high voltages. The output cabling should be connected by a qualified technician. Otherwise only use pre-made flexible cables. There are no user serviceable parts inside the amplifier.
Non-compliance with the instructions or neglecting warnings may cause malfunction or even damage the unit.
· Avoid turning on the device without the speakers connected to its outputs and without having previously set the volume/gain controls to minimum level.
· Always use shielded cables to make connections between devices. · In an amplifier, avoid placing the speaker output cables close to other signal cables
(micro, line…). This may cause the system to oscillate, damaging the amplifier and speakers.

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Connection with PC

Updates

Ctrl. HW SW

Login Main Screen

DESCRIPTION & FEATURES

Configuration

Admin Mode

INSTALL & CONNECT

6.1 Location, Assembly and Ventilation

HADA series devices have a 19″ rack format (2RU). It is very important not to enclose the amplifier or expose it to extreme temperatures as it generates heat. It is also necessary to encourage the airflow through the ventilation holes of the chassis. The ventilation system forces the airflow, front to back, through the unit. If multiple products are installed in the same rack or in a cabinet with closed doors, it is highly recommended to install fans in their upper and lower ends for a forced airflow from the bottom up. This upward air flow will help to dissipate the heat generated inside.
It is advisable not to place power amplifiers under other appliances, but upon these ones. Hada amplifiers can be stacked one on top of the other, leave one rack unit empty every 3 to guarantee an adequate heat sink.
Regular maintenance of dust removal is highly recommended as dust can impede airflow and hinder heat dissipation.

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

10

HADA DSP MANAGER & First Steps

Automatic

6.2 Mains Connection
HADA operates on alternating voltages from 90 to 264V and 47 to 63Hz. This device is equipped with an oversized power supply capable of adapting without any type of adjustment to the mains voltage of any country in the world.
On the rear panel, there is an on/off switch for the unit.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

In the front panel there is the button ON with its LED indicator that illuminates when the unit is in operation.
To enter in standby mode, press and hold the ON button until all LEDs on the front panel blink once. The prot. LED (red) will illuminate together with the ON LED (white) to indicate that standby mode is active. To exit standby mode, repeat the process.
Do not allow the mains cable to run parallel to the shielded cables carrying the audio signal, as this may cause humming.

Configuration

Device

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

11

HADA DSP MANAGER & First Steps

6.3 Analogue Input Connections
HADA rear panel provides analogue, balanced, line level signal inputs. The selection of hardware inputs and their routing and mixing towards either amplifier channel is performed from its embedded web application. For further information, please refer to HADA DSP Manager chapter.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Signal input connectors are 3 position screw terminal block. The wiring is:

Live or direct signal

> Pin

+

Cold or inverted signal > Pin

Ground

> Pin

Automatic

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

For unbalanced connection short-circuit pin to pin – as reported on the picture. 12

6.4 Amplified Output Connections
The rear panel is fitted with two position screw terminal block for each amplified output.

Ctrl. HW SW

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Always respect the relative polarity for outputs (+ and – on each output connector), wiring and speakers.
6.4.1 Out Configurations
HADA DSP Manager software allows to configure the amplifier to operate in high impedance/bridge mode, or low impedance.
Select the appropriate operation mode to do not damage the loudspeakers. Depending on the model in use, never connect loads below 2, 2.7 or 4 ohms when working in low impedance mode.
HiZ and Bridge modes must use the first or the second pair of channels. Please connect the loudspeakers as reported on the silkscreens when HiZ mode or Bridge mode is required.
Make sure to match the impedance of the total load connected to the loudspeakers, when working in low impedance for a correct performance. If impedance values do not match, select the closer one above.
6.4.1.1 Operation Example
AMP OUT1-2: HiZ-100V When OUT 1-2 are configured in bridge, use both + pins to connect the loudspeakers. The + on the left is the positive.
AMP OUT3: LoZ-8ohm AMP OUT4: LoZ-4ohm When LoZ is selected the channels operate independently with declared maximum power. The connection cable that joins the amplifiers outputs and the loudspeakers must be of good quality, sufficient section and as short as possible. This is most important when the distances to cover are long ones i.e., up to 10 meters it is recommended to use a section not inferior to 2.5mm2 and for superior distances 4mm2.
13

Groups TELNET Control

HADA DSP MANAGER & First Steps

Automatic

6.5 Remote Volume
HADA rear panel provides four remote control ports, labelled “REMOTE VOL 1-4”, to which you can connect analogue devices such as the WPa series wall panels or common 10 Kohm linear potentiometers. These ports allow to control the volume of the output channels: each REMOTE VOL input is associated with its own corresponding output channel.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

When GPIs are used in combination with front potentiometers, the potentiometer set at the lower value between the two, is the one that defines the maximum output level.

6.5.1 Connecting the REMOTE VOL Control Ports

The REMOTE VOL connectors are Euroblock type. The assignment of the connection is as follows:

Positive, + 3.3 VDC

> Pin

+

Variable voltage, 0-3.3 VDC > Pin

1-4

Ground

> Pin

The connection cables can be up to 500m long if a section of 0.5mm2 is used.

6.5.2 Connecting HADA to Ecler WPaVOL & WPaVOL-J wall control panels

Configuration

Device

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

14

HADA DSP MANAGER & First Steps

· RJ-45 Connection Diagram for WPaVOL & WPaVOL-J

RJ-45 Diagram for connections to WPaVOL & WPaVOL-J

Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8

White Orange Orange
White Green Blue
White Blue Green
White Brown Brown

VCC (+3,3V) REMOTE VOL (0V÷ +3,3V MIN÷MAX) VCC (+3,3V) N.C. N.C. GND VCC (+3,3V) Not available

· Mini-jack Connection Diagram for WPaVOL-J

Terminal Block Diagram (mini-Jack) for connections to WPaVOL-J

Pin 1

SLEEVE

Pin 2

RING

Pin 3

TIP

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Updates

Ctrl. HW SW

Connection with PC

Login Main Screen

DESCRIPTION & FEATURES

6.6 External Mute
HADA has on its rear panel a control input, or EXT. MUTE port which allows the activation / deactivation of the mute of audio outputs (zones) of the unit by means of a push button, relay, or external potential free contact closure.

Automatic

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

The EXT. MUTE works as normally open contact. 15

HADA DSP MANAGER & First Steps

6.7 Ethernet Ports
The RJ-45-type ETHERNET connector on the rear panel, named NET, allows the equipment to be connected to an Ethernet network, or directly to a computer or other device with an Ethernet interface, point-to-point.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

This connection enables, within a local network, the following: · Global programming and management of the HADA units using Windows® software HADA DSP Manager. · Connection of third-party devices for integration in control systems (Crestron®, Extron®, AMX®, Vity®, Medialon®, etc., registered trademarks by their manufacturers), using the Third Party TCP/IP control embedded in HADA devices. Refer to the Telnet Control chapter for more information.
6.8 Reset
The RESET button on the rear panel, allows to restore the network settings.

Automatic

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

In case you have set a fixed network address and have forgotten it, holding down the reset button for more than 10 seconds will allow you to set the network interface to DHCP mode as from the factory. In this way, using the HADA DSP Manager software in a PC with its network card set as a DHCP client, it will be possible to perform amplifier discovery and change the network settings again.
A factory default of the DSP parameters can be performed by uploading a factory default preset through HADA DSP Manager.
16

START-UP & OPERATION

7.1 Start-up
When the rear panel Power switch is ON, the amplifier is powered, and it will automatically switch on.

Ctrl. HW SW

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

When the ON LED of the front panel is lit in white, the device is operational.
To enter in standby mode, press and hold the ON button until all LEDs on the front panel blink once. The prot. LED (red) will illuminate together with the ON LED (white) to indicate that standby mode is active. To exit standby mode, repeat the process.
In a complete audio installation, it is important to start up the equipment in the following sequence:
1. sound sources 2. mixer 3. equalizers 4. active filters 5. processors 6. power amplifiers. To turn them off the sequence should follow an inverse pattern.
17

Groups TELNET Control

HADA DSP MANAGER & First Steps

7.2 HADA DSP Manager Configuration
Once the physical connections have been made, the HADA units must be connected using the HADA DSP Manager software.
The HADA network interface comes from the factory in DHCP client mode. This means that if a DHCP server is present in the network, it will automatically provide the IP address to the device. In the absence of a DHCP server, as in standard networks, the HADA network interface will take a random address in the 169.254.x.y class.
If your PC’s network card is also configured in DHCP mode, through the automatic discovery of the HADA DSP Manager software you can easily find all your networked amplifiers which will appear as a list in the main software window. Only one software interface can be connected to the amplifier at a time.
Once the list of amplifiers in the network is ready, you can click on the arrow to the right of each one to open the configuration window.

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Updates

Ctrl. HW SW

Automatic

Connection with PC

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

In case your HADA amplifier cannot be found by the software, please reset the unit. For further details see chapter Reset.
Please refer to HADA DSP Manager chapter for information about parameters, settings and available features.
18

HADA DSP MANAGER & First Steps

7.3 Bridge Mode and Hi-Z Mode
Bridge or HiZ mode, which allows 100V/70V line loudspeakers to be connected, must be set via the HADA DSP Manager.
Please configure the correct output mode via software before connecting the loudspeakers line:
· Dual: Each channel work as a single channel in low impedance mode.
· Bridge Mono: Two channels are coupled in bridge for high impedance lines of loudspeakers.

WARRANTY & ENVIRONMENT

PRECAUTIONS

Updates

Ctrl. HW SW

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

The selection of the load type for each output is available only by logging into HADA DSP Manager with administrator credentials.

The following table shows the different loads supported by each model:

Model
8 Dual 4 Dual HADA-4B150 125 W 125 W HADA-4B250 250 W 250 W HADA-4B400 400 W 400 W HADA-4B500 250 W 500 W HADA-4B750 400 W 750 W

Low Impedance

2,7 Dual 2 Dual

180 W

300 W

225 W

360 W

600 W

450 W

8 Bridge 4 Bridge

250 W

500 W 500 W

800 W 700 W

1000 W 1000 W

1250 W 1400 W

High Impedance

100V Bridge 70V Bridge

250 W

250 W

500 W

500 W

800 W

800 W

1000 W

1000 W

1500 W

1500 W

Once the Bridge Mono mode is set, connect the loudspeakers line at 100V or 70V as indicated below:

· The Positive pin is the left one.

of the output in bridge mode

· When channel 1 and 2 are set as bridge, the input connector to use is the Input 1 and the volume control is the one of channel 1.

· When channel 3 and 4 are set as bridge, the input connector to use is the Input 3 and the volume control is the one of channel 3.

Groups TELNET Control

19

HADA DSP MANAGER & First Steps

7.4 Recovery Mode
In case that a firmware issue appears, or a firmware update fails, the HADA unit will automatically load an emergency firmware called “Recovery Mode”. This allows to connect with Ecler HADA DSP Manager and update the firmware again with the correct firmware of each HADA model. When the unit is in this special state, all the front LEDs of the unit (Prot., Thermal, Ext. Mute, Data and ON) will blink at the same time. Audio signal will be processed by the DSP and a special limitation of all the outputs will avoid damaging the amplifier modules.
To exit from recovery mode, please enter the administrator credentials and update the firmware of the unit.
Each HADA unit needs to be updated with the right firmware related to each model.

WARRANTY & ENVIRONMENT

PRECAUTIONS

Updates

Ctrl. HW SW

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

20

HADA DSP MANAGER & First Steps

Automatic

TECHNICAL DATA

8.1 Technical Specifications

8.1.1 HADA-4B150

HADA-4B150

INPUTS

Number of Inputs 4 analogue input channels

Analogue input connection type IN1-4: 3-pin Euroblock, balanced, pitch 3,5 mm.

Input configuration Digital matrix 4 in x 4 amp. out

(Settings by HADA DSP Manager)

AMPLIFIED OUTPUTS

Number of amplified outputs 4

Amplified output connection type 2-pin Euroblock.

Output configuration Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per channel/couple by software

(Settings by HADA DSP Manager)

OUTPUT POWER (all channels driven @ 1%THD)

Max output power @ 8 Max output power @ 4 Max output power @ 8 bridge mode Max output power @ 100V

125W 125W 250W 250W (Bridge Mode)

Max output power @ 70V 250W (Bridge Mode)

SIGNAL

Voltage gain 27 to 37 dBV 29,2 to 39,2 dBu

Input sensitivity -12 to 12 dBV

-9,8 to 14,2 dBu

0,25 to 3,98 Vrms @ Nominal power

Input impedance 21k (balanced)

Max input level 22 dBV

24,2 dBu

Frequency response 20Hz-20kHz (-3dB, 1W any load)

THD + Noise < 0,01

0.015 Typ

(@ 1kHz, from 0,1W to Full Power)

Crosstalk >60dB (@ 1kHz)

ELECTRICAL

Power supply Universal, SMPS with PFC

AC mains requirement 100-240 V @ 50-60Hz (±10%)

Power factor correction > 0,92

AC mains connector IEC C14 inlet

POWER CONSUMPTION @230VAC

Power Consumption (1/4 POWER, @ 4) Power Consumption (1/8 POWER, @ 4)
Power Consumption (IDLE)

277W (all channels driven) 145W (all channels driven) 14.5W

Power Consumption (STBY) 8.5W

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

21

HADA DSP MANAGER & First Steps

Automatic

TECHNOLOGIES Amplification technology Cooling

PROTECTIONS

Maximum fan noise DC protection

HF protection

Short-circuit protection

Thermal protection

REMOTE CONTROL CONNECTIONS ON / OFF GPIs
External MUTE

LOCAL CONTROL

Attenuators

Output mode settings

RUN/SLEEP mode

CONNECTIVITY

Power ON/OFF Ethernet

MONITORING

Programming and control
Signal Present Clipping Limit Mute Prot.

DIGITAL ENGINE

Thermal Ext. Mute
Data On
Standby
Processor

Class D Fan (Forced air, front to back airflow. Temperature controlled continuously variable speed) 46 dB (Maximum acoustical noise @1m)
Yes (Protects loudspeaker and installation against DC and infrasonic signals at the outputs) Yes (Protects the loudspeakers against non-audible, strong, non-musical high frequency signals) Yes (Protects the amplifier from overcurrent, short circuit or other stressful events for the output stages with output reduction or MUTE (automatic protection reset)) Yes (Output power reduction when output stages operating temperature up to 90 °C (194 °F) Mute when output stages operating temperature up to 100 °C (212 °F))
No x4 GPIs (0-3.3V) (5-pin Euroblock connector, rear panel) Yes, dry contact (2 pins Euroblock connector, rear panel. Euroblock pitch 3,5 mm)
Front panel knobs (Defaults: Amplified OUTs attenuators) Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per couple of channels (Software) Yes, front panel push-button (Operates when pressed more than 3 seconds) Yes, back panel switch (Red LED indicator)
Ethernet Base-Tx 100Mb (CAT5 up to 100m. Settings by embedded web application) HADA DSP Manager Application
SP LED (White) per channel (trigger @- 40 dBV) CLIP LED (Red) per channel LIMIT LED (Red) per channel MUTE LED (White) per channel PROT. LED (Red) per unit + MUTE of the protected channel THERMAL LED (Red) per unit (Temperature limiter) Ext. MUTE LED (White) per unit DATA LED (White) per unit (ON when DATA) ON LED (White) per unit (ON when RUN) ON LED (White) + PROT. LED (Red) in standby mode
Dual core 64bits

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

22

HADA DSP MANAGER & First Steps

AUDIO CONVERTERS PROCESSING

Sampling rate Resolution
Dynamic range
Digital processing Latency
Inputs processing

Outputs processing

Others

PHYSICAL

Operating temperature

Operating humidity Storage temperature
Storage humidity Installation options Included accessories
Optional accessories Dimensions (WxHxD)
Weight Shipping dimensions (WxHxD)
Shipping weight

96 kHz 24 bit 113 dB
64 bit 500uS (Analogue IN to analogue OUT) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Preset management, 4×4 Matrix Mixer (Settings via HADA DSP Manager)
Min. 0ºC; 32ºF Max. 40ºC; 104ºF (performance may be reduced above 40°C) 5 – 80% RH, non-condensing Min. -10ºC; 14ºF Max. 50ºC; 122ºF 5 – 85% RH, non-condensing Rack 19″ installation & desktop EU Main cord, Euroblock Connectors (inputs /outputs), Desktop feet, rack 19″ installation hardware. 482.6 x 88 x 281,5 mm / 19 x 3.46 x 11.08 in. 4.7 Kg / 10.36 lb 495 x 125 x 560 mm. / 19.48 x 4.92 x 22.05 in. 6,8 kg / 14.9 lb

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Connection with PC

Updates

Ctrl. HW SW

Automatic

Login Main Screen

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

23

8.1.2 HADA-4B250

HADA-4B250

INPUTS

Number of Inputs 4 analogue input channels Analogue input connection type IN1-4: 3-pin Euroblock, balanced, pitch 3,5 mm.

Input configuration Digital matrix 4 in x 4 amp. out (Settings by HADA DSP Manager)

AMPLIFIED OUTPUTS

Number of amplified outputs Amplified output connection type
Output configuration

4 2-pin Euroblock. Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per channel/couple by software (Settings by HADA DSP Manager)

OUTPUT POWER (all channels driven @ 1%THD)

Max output power @ 8 Max output power @ 4 Max output power @ 2.7 Max output power @ 8 bridge mode Max output power @ 4 bridge mode Max output power @ 100V Max output power @ 70V

250W 250W 180W 500W 500W 500W (Bridge Mode) 500W (Bridge Mode)

SIGNAL

Voltage gain Input sensitivity
Input impedance Max input level
Frequency response THD + Noise
Crosstalk

30 to 37 dBV 32,2 to 39,2 dBu -12 to 12 dBV -9,8 to 14,2 dBu 0,25 to 3,98 Vrms @ Nominal power 21k (balanced) 22 dBV 24,2 dBu 20Hz-20kHz (-3dB, 1W any load) < 0,01 0.015 Typ (@ 1kHz, from 0,1W to Full Power) >80dB (@ 1kHz)

ELECTRICAL

Power supply AC mains requirement Power factor correction
AC mains connector

Universal, SMPS with PFC 100-240 V @ 50-60Hz (±10%) > 0,92 IEC C14 inlet

POWER CONSUMPTION @230VAC

Power Consumption (1/4 POWER, @ 4) Power Consumption (1/8 POWER, @ 4)
Power Consumption (IDLE) Power Consumption (STBY)

428W (all channels driven) 235W (all channels driven) 19W 13W

TECHNOLOGIES

Amplification technology Cooling
Maximum fan noise

Class D Fan (Forced air, front to back airflow. Temperature controlled continuously variable speed) 40 dB (Maximum acoustical noise @1m)

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW
24

Groups TELNET Control

Admin Mode

Login Main Screen

Device

Automatic

HADA DSP MANAGER & First Steps

HADA DSP MANAGER & First Steps

Automatic

PROTECTIONS

DC protection HF protection Short-circuit protection

Thermal protection

REMOTE CONTROL CONNECTIONS ON / OFF GPIs
External MUTE

LOCAL CONTROL

Attenuators

Output mode settings

RUN/SLEEP mode

CONNECTIVITY

Power ON/OFF Ethernet

MONITORING

Programming and control
Signal Present Clipping Limit Mute Prot.

DIGITAL ENGINE AUDIO CONVERTERS

Thermal Ext. Mute
Data On
Standby
Processor
Sampling rate Resolution
Dynamic range

Yes (Protects loudspeaker and installation against DC and infrasonic signals at the outputs) Yes (Protects the loudspeakers against non-audible, strong, non-musical high frequency signals) Yes (Protects the amplifier from overcurrent, short circuit or other stressful events for the output stages with output reduction or MUTE (automatic protection reset)) Yes (Output power reduction when output stages operating temperature up to 90 °C (194 °F) Mute when output stages operating temperature up to 100 °C (212 °F))
No x4 GPIs (0-3.3V) (5-pin Euroblock connector, rear panel) Yes, dry contact (2 pins Euroblock connector, rear panel. Euroblock pitch 3,5 mm)
Front panel knobs (Defaults: Amplified OUTs attenuators) Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per couple of channels (Software) Yes, front panel push-button (Operates when pressed more than 3 seconds) Yes, back panel switch (Red LED indicator)
Ethernet Base-Tx 100Mb (CAT5 up to 100m. Settings by embedded web application) HADA DSP Manager Application
SP LED (White) per channel (trigger @- 40 dBV) CLIP LED (Red) per channel LIMIT LED (Red) per channel MUTE LED (White) per channel PROT. LED (Red) per unit + MUTE of the protected channel THERMAL LED (Red) per unit (Temperature limiter) Ext. MUTE LED (White) per unit DATA LED (White) per unit (ON when DATA) ON LED (White) per unit (ON when RUN) ON LED (White) + PROT. LED (Red) in standby mode
Dual core 64bits
96 kHz 24 bit 113 dB

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

25

HADA DSP MANAGER & First Steps

PROCESSING PHYSICAL

Digital processing Latency
Inputs processing Outputs processing
Others
Operating temperature

Operating humidity Storage temperature
Storage humidity Installation options Included accessories
Optional accessories Dimensions (WxHxD)
Weight Shipping dimensions (WxHxD)
Shipping weight

64 bit 500uS (Analogue IN to analogue OUT) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Preset management, 4×4 Matrix Mixer (Settings via HADA DSP Manager)
Min. 0ºC; 32ºF Max. 40ºC; 104ºF (performance may be reduced above 40°C) 5 – 85% RH, non-condensing Min. -10ºC; 14ºF Max. 50ºC; 122ºF 5 – 80% RH, non-condensing Rack 19″ installation & desktop EU Main cord, Euroblock Connectors (inputs /outputs), Desktop feet, rack 19″ installation hardware 482.6 x 88 x 281,5 mm / 19 x 3.46 x 11.08 in. 5.0 Kg / 11.02 lb 495 x 125 x 560 mm. / 19.48 x 4.92 x 22.05 in. 6,8 kg / 14.9 lb

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Connection with PC

Updates

Ctrl. HW SW

Automatic

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

26

HADA DSP MANAGER & First Steps

Automatic

8.1.3 HADA-4B400

HADA-4B400

INPUTS

Number of Inputs 4 analogue input channels

Analogue input connection type IN1-4: 3-pin Euroblock, balanced, pitch 3,5 mm.

Input configuration Digital matrix 4 in x 4 amp. out

(Settings by HADA DSP Manager)

AMPLIFIED OUTPUTS

Number of amplified outputs 4

Amplified output connection type 2-pin Euroblock.

Output configuration Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per channel/couple by software

(Settings by HADA DSP Manager)

OUTPUT POWER (all channels driven @ 1%THD)

Max output power @ 8 Max output power @ 4 Max output power @ 2.7 Max output power @ 2 Max output power @ 8 bridge mode Max output power @ 4 bridge mode Max output power @ 100V

400W 400W 300W 225W 800W 700W 800W (Bridge mode)

Max output power @ 70V 800W (Bridge Mode)

SIGNAL

Voltage gain 31 to 38 dBV

33,2 to 40,2 dBu

Input sensitivity -12 to 12 dBV

-9,8 to 14,2 dBu

0,25 to 3,98 Vrms @ Nominal power

Input impedance 21k (balanced)

Max input level 22 dBV

24,2 dBu

Frequency response 20Hz-20kHz (-3dB, 1W any load)

THD + Noise < 0,01

0.015 Typ

(@ 1kHz, from 0,1W to Full Power)

Crosstalk >80dB (@ 1kHz)

ELECTRICAL

Power supply Universal, SMPS with PFC

AC mains requirement 100-240 V @ 50-60Hz (±10%)

Power factor correction > 0,96

AC mains connector IEC C14 inlet

POWER CONSUMPTION @230VAC

Power Consumption (1/4 POWER, @ 4) Power Consumption (1/8 POWER, @ 4)
Power Consumption (IDLE)

621W (all channels driven) 345W (all channels driven) 20W

Power Consumption (STBY) 9W

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

27

HADA DSP MANAGER & First Steps

Automatic

TECHNOLOGIES Amplification technology Cooling

PROTECTIONS

Maximum fan noise DC protection

HF protection

Short-circuit protection

Thermal protection

REMOTE CONTROL CONNECTIONS ON / OFF GPIs
External MUTE

LOCAL CONTROL

Attenuators

Output mode settings

RUN/SLEEP mode

CONNECTIVITY

Power ON/OFF Ethernet

MONITORING

Programming and control
Signal Present Clipping Limit Mute Prot.

DIGITAL ENGINE

Thermal Ext. Mute
Data On
Standby
Processor

Class D Fan (Forced air, front to back airflow. Temperature controlled continuously variable speed) 40 dB (Maximum acoustical noise @1m)
Yes (Protects loudspeaker and installation against DC and infrasonic signals at the outputs) Yes (Protects the loudspeakers against non-audible, strong, non-musical high frequency signals) Yes (Protects the amplifier from overcurrent, short circuit or other stressful events for the output stages with output reduction or MUTE (automatic protection reset)) Yes (Output power reduction when output stages operating temperature up to 90 °C (194 °F) Mute when output stages operating temperature up to 100 °C (212 °F))
No x4 GPIs (0-3.3V) (5-pin Euroblock connector, rear panel) Yes, dry contact (2 pins Euroblock connector, rear panel. Euroblock pitch 3,5 mm)
Front panel knobs (Defaults: Amplified OUTs attenuators) Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per couple of channels (Software) Yes, front panel push-button (Operates when pressed more than 3 seconds) Yes, back panel switch (Red LED indicator)
Ethernet Base-Tx 100Mb (CAT5 up to 100m. Settings by embedded web application) HADA DSP Manager Application
SP LED (White) per channel (trigger @- 40 dBV) CLIP LED (Red) per channel LIMIT LED (Red) per channel MUTE LED (White) per channel PROT. LED (Red) per unit + MUTE of the protected channel THERMAL LED (Red) per unit (Temperature limiter) Ext. MUTE LED (White) per unit DATA LED (White) per unit (ON when DATA) ON LED (White) per unit (ON when RUN) ON LED (White) + PROT. LED (Red) in standby mode
Dual core 64bits

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

28

HADA DSP MANAGER & First Steps

AUDIO CONVERTERS

PROCESSING

Sampling rate Resolution
Dynamic range

96 kHz 24 bit 113 dB

Digital processing Latency
Inputs processing
Outputs processing

64 bit 500uS (Analogue IN to analogue OUT) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager)

Others Preset management, 4×4 Matrix Mixer (Settings via HADA DSP Manager)

PHYSICAL

Operating temperature
Operating humidity Storage temperature
Storage humidity Installation options Included accessories
Optional accessories Dimensions (WxHxD)
Weight Shipping dimensions (WxHxD)
Shipping weight

Min. 0ºC; 32ºF Max. 40ºC; 104ºF (performance may be reduced above 40°C) 5 – 80% RH, non-condensing Min. -10ºC; 14ºF Max. 50ºC; 122ºF 5 – 85% RH, non-condensing Rack 19″ installation & desktop EU Main cord, Euroblock Connectors (inputs /outputs), Desktop feet, rack 19″ installation hardware 482.6 x 88 x 281,5 mm / 19 x 3.46 x 11.08 in. 5.4 Kg / 11.91 lb 495 x 125 x 560 mm. / 19.48 x 4.92 x 22.05 in. 7,5 kg / 16.53 lb

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Connection with PC

Updates

Ctrl. HW SW

Login Main Screen

Automatic

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

29

HADA DSP MANAGER & First Steps

Automatic

8.1.4 HADA-4B500
HADA-4B500
INPUTS Number of Inputs 4 analogue input channels
Analogue input connection type IN1-4: 3-pin Euroblock, balanced, pitch 3,5 mm. Input configuration Digital matrix 4 in x 4 amp. out (Settings by HADA DSP Manager)
AMPLIFIED OUTPUTS Number of amplified outputs 4
Amplified output connection type 2-pin Euroblock. Output configuration Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per channel/couple by software (Settings by HADA DSP Manager)
OUTPUT POWER (all channels driven @ 1%THD) Max output power @ 8 250W Max output power @ 4 500W
Max output power @ 2.7 360W Max output power @ 8 bridge mode 1000W Max output power @ 4 bridge mode 1000W
Max output power @ 100V 1000W (Bridge mode) Max output power @ 70V 1000W (Bridge mode)
SIGNAL Voltage gain 31 to 37 dBV 33,2 to 39,2 dBu
Input sensitivity -12 to 12 dBV -9,8 to 14,2 dBu 0,25 to 3,98 Vrms @ Nominal power
Input impedance 21k (balanced) Max input level 22 dBV 24,2 dBu
Frequency response 20Hz-20kHz (-3dB, 1W any load) THD + Noise < 0,01 0.015 Typ (@ 1kHz, from 0,1W to Full Power) Crosstalk >80dB (@ 1kHz)
ELECTRICAL Power supply Universal, SMPS with PFC
AC mains requirement 100-240 V @ 50-60Hz (±10%) Power factor correction > 0,92
AC mains connector IEC C14 inlet POWER CONSUMPTION @230VAC
Power Consumption (1/4 POWER, @ 4) 827W (all channels driven) Power Consumption (1/8 POWER, @ 4) 427W (all channels driven)
Power Consumption (IDLE) 25.5W Power Consumption (STBY) 20W

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

30

HADA DSP MANAGER & First Steps

Automatic

TECHNOLOGIES Amplification technology Cooling

PROTECTIONS

Maximum fan noise DC protection

HF protection

Short-circuit protection

Thermal protection

REMOTE CONTROL CONNECTIONS ON / OFF GPIs
External MUTE

LOCAL CONTROL

Attenuators

Output mode settings

RUN/SLEEP mode

CONNECTIVITY

Power ON/OFF Ethernet

MONITORING

Programming and control
Signal Present Clipping Limit Mute Prot.

DIGITAL ENGINE

Thermal Ext. Mute
Data On
Standby
Processor

Class D Fan (Forced air, front to back airflow. Temperature controlled continuously variable speed) 46dB (Maximum acoustical noise @1m)
Yes (Protects loudspeaker and installation against DC and infrasonic signals at the outputs) Yes (Protects the loudspeakers against non-audible, strong, non-musical high frequency signals) Yes (Protects the amplifier from overcurrent, short circuit or other stressful events for the output stages with output reduction or MUTE (automatic protection reset)) Yes (Output power reduction when output stages operating temperature up to 90 °C (194 °F) Mute when output stages operating temperature up to 100 °C (212 °F))
No x4 GPIs (0-3.3V) (5-pin Euroblock connector, rear panel) Yes, dry contact (2 pins Euroblock connector, rear panel. Euroblock pitch 3,5 mm)
Front panel knobs (Defaults: Amplified OUTs attenuators) Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per couple of channels (Software) Yes, front panel push-button (Operates when pressed more than 3 seconds) Yes, back panel switch (Red LED indicator)
Ethernet Base-Tx 100Mb (CAT5 up to 100m. Settings by embedded web application) HADA DSP Manager Application
SP LED (White) per channel (trigger @- 40 dBV) CLIP LED (Red) per channel LIMIT LED (Red) per channel MUTE LED (White) per channel PROT. LED (Red) per unit + MUTE of the protected channel THERMAL LED (Red) per unit (Temperature limiter) Ext. MUTE LED (White) per unit DATA LED (White) per unit (ON when DATA) ON LED (White) per unit (ON when RUN) ON LED (White) + PROT. LED (Red) in standby mode
Dual core 64bits

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

31

HADA DSP MANAGER & First Steps

AUDIO CONVERTERS

Sampling rate 96 kHz Resolution 24 bit
Dynamic range 113 dB

PROCESSING PHYSICAL

Digital processing Latency
Inputs processing Outputs processing
Others
Operating temperature

Operating humidity Storage temperature
Storage humidity Installation options Included accessories
Optional accessories Dimensions (WxHxD)
Weight Shipping dimensions (WxHxD)
Shipping weight

64 bit 500uS (Analogue IN to analogue OUT) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Preset management, 4×4 Matrix Mixer (Settings via HADA DSP Manager)
Min. 0ºC; 32ºF Max. 40ºC; 104ºF (performance may be reduced above 40°C) 5 – 80% RH, non-condensing Min. -10ºC; 14ºF Max. 50ºC; 122ºF 5 – 85% RH, non-condensing Rack 19″ installation & desktop EU Main cord, Euroblock Connectors (inputs /outputs), Desktop feet, rack 19″ installation hardware 482.6 x 88 x 281,5 mm / 19 x 3.46 x 11.08 in. 5.6 Kg / 12.35 lb 495 x 125 x 560 mm / 19.48 x 4.92 x 22.05 in. 7,7 8 kg / 16.97 lb

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Connection with PC

Updates

Ctrl. HW SW

Login Main Screen

Automatic

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

32

HADA DSP MANAGER & First Steps

Automatic

8.1.5 HADA-4B750

HADA-4B750

INPUTS Number of Inputs 4 analogue input channels
Analogue input connection type IN1-4: 3-pin Euroblock, balanced, pitch 3,5 mm. Input configuration Digital matrix 4 in x 4 amp. out (Settings by HADA DSP Manager)
AMPLIFIED OUTPUTS Number of amplified outputs 4
Amplified output connection type 2-pin Euroblock. Output configuration Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per channel/couple by software (Settings by HADA DSP Manager)
OUTPUT POWER (all channels driven @ 1%THD) Max output power @ 8 400W Max output power @ 4 750W
Max output power @ 2.7 600W Max output power @ 2 450W
Max output @ 8 bridge mode 1250W Max output @ 4 bridge mode 1400W
Max output power @ 100V 1500W (Bridge Mode) Max output power @ 70V 1500W (Bridge Mode)
SIGNAL Voltage gain 31 to 38 dBV 33,2 to 40,2 dBu

Input sensitivity -12 to 12 dBV -9,8 to 14,2 dBu 0,25 to 3,98 Vrms @ Nominal power

Input impedance 21k (balanced) Max input level 22 dBV 24,2 dBu

Frequency response THD + Noise
Crosstalk ELECTRICAL
Power supply AC mains requirement Power factor correction
AC mains connector POWER CONSUMPTION @230VAC
Power Consumption (1/4 POWER, @ 4) Power Consumption (1/8 POWER, @ 4)
Power Consumption (IDLE) Power Consumption (STBY)

20Hz-20kHz (-3dB, 1W any load) < 0,01 0.015 Typ (@ 1kHz, from 0,1W to Full Power) >80dB (@ 1kHz)
Universal, SMPS with PFC 100-240 V @ 50-60Hz (±10%) > 0,96 IEC C14 inlet
1220W (all channels driven) 601W (all channels driven) 23W 10W

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Groups TELNET Control

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

33

HADA DSP MANAGER & First Steps

Automatic

TECHNOLOGIES Amplification technology Cooling

PROTECTIONS

Maximum fan noise DC protection

HF protection

Short-circuit protection

Thermal protection

REMOTE CONTROL CONNECTIONS ON / OFF GPIs
External MUTE

LOCAL CONTROL

Attenuators

Output mode settings

Class D Fan (Forced air, front to back airflow. Temperature controlled continuously variable speed) 46 dB (Maximum acoustical noise @1m)
Yes (Protects loudspeaker and installation against DC and infrasonic signals at the outputs) Yes (Protects the loudspeakers against non-audible, strong, non-musical high frequency signals) Yes (Protects the amplifier from overcurrent, short circuit or other stressful events for the output stages with output reduction or MUTE (automatic protection reset)) Yes (Output power reduction when output stages operating temperature up to 90 °C (194 °F) Mute when output stages operating temperature up to 100 °C (212 °F))
No x4 GPIs (0-3.3V) (5-pin Euroblock connector, rear panel) Yes, dry contact (2 pins Euroblock connector, rear panel. Euroblock pitch 3,5 mm)
Front panel knobs (Defaults: Amplified OUTs attenuators) Lo-Z/Hi-Z, 70V/100V, 4/8 Output mode selection per couple of channels (Software)

RUN/SLEEP mode

CONNECTIVITY

Power ON/OFF Ethernet

MONITORING

Programming and control
Signal Present Clipping Limit Mute Prot.

DIGITAL ENGINE

Thermal Ext. Mute
Data On
Standby
Processor

Yes, front panel push-button (Operates when pressed more than 3 seconds) Yes, back panel switch (Red LED indicator)
Ethernet Base-Tx 100Mb (CAT5 up to 100m. Settings by embedded web application) HADA DSP Manager Application
SP LED (White) per channel (trigger @- 40 dBV) CLIP LED (Red) per channel LIMIT LED (Red) per channel MUTE LED (White) per channel PROT. LED (Red) per unit + MUTE of the protected channel THERMAL LED (Red) per unit (Temperature limiter) Ext. MUTE LED (White) per unit DATA LED (White) per unit (ON when DATA) ON LED (White) per unit (ON when RUN) ON LED (White) + PROT. LED (Red) in standby mode
Dual core 64bits

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Groups TELNET Control

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

34

HADA DSP MANAGER & First Steps

AUDIO CONVERTERS PROCESSING

Sampling rate Resolution
Dynamic range
Digital processing Latency
Inputs processing

Outputs processing Others

PHYSICAL

Operating temperature

Operating humidity Storage temperature
Storage humidity Installation options Included accessories
Optional accessories Dimensions (WxHxD)
Weight Shipping dimensions (WxHxD)
Shipping weight

96 kHz 24 bit 113dB
64 bit 500uS (Analogue IN to analogue OUT) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Delay, Parametric EQ, Limiter, Multiband compressor (Settings via HADA DSP Manager) Preset management, 4×4 Matrix Mixer (Settings via HADA DSP Manager)
Min. 0ºC; 32ºF Max. 40ºC; 104ºF (performance may be reduced above 40°C) 5 – 80% RH, non-condensing Min. -10ºC; 14ºF Max. 50ºC; 122ºF 5 – 85% RH, non-condensing Rack 19″ installation & desktop EU Main cord, Euroblock Connectors (inputs /outputs), Desktop feet, rack 19″ installation hardware 482.6 x 88 x 281,5 mm / 19 x 3.46 x 11.08 in. 6.0 Kg / 13.22 lbs 495 x 125 x 560 mm / 19.48 x 4.92 x 22.05 in. 8,1 kg / 17,85 lb

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Connection with PC

Updates

Ctrl. HW SW

Automatic

Login Main Screen

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

35

3 6

Ctrl. HW SW

HADA DSP MANAGER & First Steps

Automatic

Login Main Screen

Device

Updates

Connection with PC

Configuration

Admin Mode

Groups TELNET Control

PRECAUTIONS

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

DESCRIPTION & FEATURES

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

8.2 Mechanical Diagrams 8.2.1 HADA-4B150

3 7

Ctrl. HW SW

HADA DSP MANAGER & First Steps

Automatic

Login Main Screen

Device

Updates

Connection with PC

Configuration

Admin Mode

Groups TELNET Control

PRECAUTIONS

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

DESCRIPTION & FEATURES

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

8.2.2 HADA-4B250

3 8

Ctrl. HW SW

HADA DSP MANAGER & First Steps

Automatic

Login Main Screen

Device

Updates

Connection with PC

Configuration

Admin Mode

Groups TELNET Control

PRECAUTIONS

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

DESCRIPTION & FEATURES

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

8.2.3 HADA-4B400

3 9

Ctrl. HW SW

HADA DSP MANAGER & First Steps

Automatic

Login Main Screen

Device

Updates

Connection with PC

Configuration

Admin Mode

Groups TELNET Control

PRECAUTIONS

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

DESCRIPTION & FEATURES

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

8.2.4 HADA-4B500

4 0

Ctrl. HW SW

HADA DSP MANAGER & First Steps

Automatic

Login Main Screen

Device

Updates

Connection with PC

Configuration

Admin Mode

Groups TELNET Control

PRECAUTIONS

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

DESCRIPTION & FEATURES

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

8.2.5 HADA-4B750

HADA DSP MANAGER & First Steps

Automatic

9. HADA DSP MANAGER
HADA series digital amplifiers are configured and controlled through their windows application HADA DSP Manager. This interface allows programming and control devices through different access levels.
Demo version available with no physical connection! Visit our website www.ecler.com and download the HADA DSP Manager softw0are ready to be used in DEMO mode to explore the capabilities of these devices. Note that some features, such as firmware update or output mode among others, require a physical connection to HADA device.

PRECAUTIONS

Updates

Ctrl. HW SW

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Configuration

HADA DSP MANAGER

9.1 Updates
· Current version: V4.0.0 (October 2024) o New graphic visualization and restrictions for user profile. o Improved management of output mode (Bridge mode) o 2 Ohm and 2.7 Ohm loads supported (Depending on model) o Maximum Delay time increased for Input and Outputs (2s) o Minor bug fixes and performance improvements.
· Previous version: V3.9.1 (March 2024) o Official release version of HADA Series.
9.2 First Steps
To access the HADA DSP Manager software, it is necessary to download and install the Windows application by clicking on this link.
First, make sure that both devices are physically connected to the same local area network (LAN), and configured as DHCP clients.
0 HADA device is in DHCP network configuration mode by factory default. If you have a router/switch with a DHCP server (see the specifications for your device), network configuration is automatic so there is no need for you to do any re-configuration.
If new software releases are installed, 0it is necessary to uninstall the previous version via the Windows program manager.

Admin Mode

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

41

HADA DSP MANAGER & First Steps

9.3 Automatic Connection using a Computer
1. Connect the HADA device to the router/switch or point to point by using a CAT5 or higher cable.
2. Set your computer to DHCP client mode by selecting “obtain an IP address automatically” in the network settings (this is the usual default setting).
3. Open the HADA DSP Manager application. All HADA units connected to your network will be listed.
In the event that some HADA unit is static IP configured instead of the factory network settings, it will be necessary t0o configure the computer’s network card the same network range in order the application locate all units.
4. Once HADA units connected to the network appear listed on the screen, click on the arrow to the right of the unit to open the configuration window of the selected one.

WARRANTY & ENVIRONMENT

PRECAUTIONS

Updates

Ctrl. HW SW

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

In the event that your HADA amplifi0er does not appear, please reset the unit. For further details, please refer to the Reset chapter.

Automatic

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

42

9.4 Login
There are 2 profiles that can access the app:
1. Admin: An administrator has access to all features of the HADA device, is allowed to configure any parameter of the amplifier as well as assigning password to the users who will have limited access to the features.
2. User: the user has limited access. The only role available to users is as controllers and restrictions will be determined by the administrator.

PRECAUTIONS

Ctrl. HW SW

HADA DSP MANAGER & First Steps

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Administrator access is password-protected. Enter the password in “Hardware > Enter Password”:
· Password (by default): admin The administrator can change his own a0ccess password from the HADA DSP Manager
application and, in addition, can manage the user rights. Usernames and passwords are case-sen0sitive. The user has no password preset by defa0ult. To switch from administrator mode to user
mode, simply leave the password field empty and press “enter” on the keyboard. 43

Groups TELNET Control

9.5 Main Screen
HADA DSP Manager main screen elements:

Ctrl. HW SW

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

1. App bar allows to perform actions on the projects and on general settings. 2. Displays information on the number of connected units listed on the main screen. 3. Displays information about each of the connected units listed.
When the application is opened, all HADA units connected to your network will be listed.
0 In the event that some HADA unit is static IP configured instead of the factory network settings, it will be necessary to configure the computer’s network card the same network range in order the application locate all units. 4. Press to access the configuration menu for the selected device.
Features of the main screen menu are de0tailed in the following chapters.
44

Groups TELNET Control

HADA DSP MANAGER & First Steps

9.5.1 File
Project management functions for replication or replacement in case of hardware changes.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

· New Project: select to create a new project. · Open Project: select to open an existing project. · Save Project: select to save the new created project.
9.5.2 Tools
Application configuration options.

Automatic

Connection with PC

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

· Set Software Password: lets you assign a password to access the HADA DSP Manager. To disable this feature, simply leave t0he password blank.
· New Group: lets you create a group of devices and control some parameters, such as mute and volume, simultaneously.
· Open Group: lets you open a device group previously created. For further information, please refer to 0the Groups chapter.
· Language: lets you choose the UI language.
45

HADA DSP MANAGER & First Steps

· Use High DPI display: lets you modify the UI display size in case of using computers with high screen resolution.
· Enter Demo Mode: lets you explore the HADA DSP Manager functionalities without being physically connected to a device.
· Enable Update: By assigning a password it is possible to enable or disable the firmware update feature on main menu.
· Select Background Image: lets you upload a background image on the app, such as floor plans to help the user to use the groups in a more intuitive and user-friendly way.
· Remove Background Image: lets you remove the current background image in use.
For more information, refer to Groups0chapter.

PRECAUTIONS

Updates

Ctrl. HW SW

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

9.5.3 Window
To manage the amplifier and group configuration windows.

Automatic

Connection with PC

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

· Main: redirects to the main menu of HADA DSP Manager. · Show All Units: opens the configuration windows of connected amplifiers. · Show All Groups: opens all the configuration windows of created groups. · Close All Units: closes all configuration windows of connected amplifiers. · Close All Groups: closes all the configuration windows of all the groups. · Unit: opens the configuration window of the indicated amplifier.
46

HADA DSP MANAGER & First Steps

Automatic

9.5.4 Help
Provides technical support and software version info.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

· Request Support: automatically redirects to the Ecler Support website. · About: provides info about the software version.
9.6 Device Configuration
Allows to configure all parameters of the HADA amplifier according to the selected user type.
· User mode: The HADA DSP Manager software is connected to the amplifier with user credentials by default. This profile does not require a password. The administrator (admin) is allowed to limit the features to the end-user. For further details see chapter Change Access Rights for User level.
By default, the user mode has no access to the load type configuration (2 Ohm, 2.7 Ohm, 4 Ohm, 8 Ohm, 8 Ohm Bridge, 100V0, 70V), nor saving presets, but is only able to load the presets saved by the administrator and is not permitted to update the firmware of the devices.
· Admin mode: is intended for installers and allows access to all amplifier configuration parameters.
From the HADA DSP Manager main screen, click on the arrow to the right of the unit to access the configuration menu of the selected unit.

Configuration

Admin Mode

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

47

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Ctrl. HW SW
1. Configuration window bar lets you access to the device features. 2. Page displays all the configuration parameter options for the selected setting, only
accessible from “Admin” mode. Features and options of the Devic0e Configuration Menu are detailed in the following chapters.
9.6.1 File
To manage presets.
· Import: lets you load local presets previously saved on the PC by the admin. Please note that with user profile it 0is only permitted to load presets, while with
the administrator (admin) profile, loading and saving presets are permitted. For further information on preset man0agement, please refer to the chapter Boot-Up
Mode. · Quit: lets you close the configuration window.
48

Groups TELNET Control

HADA DSP MANAGER & First Steps

Automatic

9.6.2 Edit

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

· Copy Channel: After selecting an input or output channel, this option lets you copy the channel DSP parameters for a quick replica to other channels.
· Paste Channel: lets you paste the copied parameters into another channel. · Snapshots: “Make a snapshot” option lets you create “snapshots” of the DSP parameters
and move them from one snapshot to another in a quick way by using “Restore”, without the need to use the preset feature.
Restore feature allows you to view t0he record of changes and revert to previous configurations in case of errors.
This feature is very useful for example when comparing volumes or equalizations. Example:
After creating two snapshots named EQ Zero (flat equalization) and EQ1, it is very easy to compare the two results by selecting the related snapshots.
Snapshots will not be saved on the 0device. Therefore, so they will disappear at the end of the session.
· Output Limiter Unit: lets you to select the measurement unit for input and output limiters to facilitate the configuration depending on the system in use. Any of the following options can be selected:

Configuration

Admin Mode

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

49

HADA DSP MANAGER & First Steps

9.6.3 Window
Allows direct access to the unit configuration windows, starting by the windows of all the units or the groups created.
In the same way it also lets you to quickly close all the configuration windows of the units or groups.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

For further details on each one of the op0tions in this menu, please refer to the Window chapter of the HADA DSP Manager Main screen.
9.6.4 Hardware
Allows access to password management and device status mode.

Automatic

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

· Enter Password: this option automatically opens a window to enter the user or administrator password in order to access to configuration mode menus.
· Go to Standby/Exit Standby: to enter and exit Standby mode in the same way as by the ON button on the front panel of the unit.
· Status details: informs about the current temperature, the status of the front panel and any possible errors detected by the DSP.
50

HADA DSP MANAGER & First Steps

9.6.5 Help
Displays useful unit’s information such as IP and MAC addresses and the firmware version in use as well.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

9.6.6 Main
Allows a global display of the amplifier signals status.

Automatic

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

1. Routing section lets you select one of the following signals for each input: This allows to assign to a DSP input the related analogue input, the sum of two inputs (if for example a mono sum is needed) or a signal coming from one of the internal generators.
51

HADA DSP MANAGER & First Steps

Automatic

2. Display and Control section displays the input and output levels through its VU meters. It is possible to modify the levels through the faders or by directly entering the values in the numerical boxes below the faders. In addition, lets you link the faders (in the case of stereo inputs or outputs), activate or deactivate the input and output mute and, also, change the name of the inputs and outputs for easy identification.
3. Presets section lets you manage presets, saving or selecting presets stored in the memory of the unit itself or local presets (saved on the PC).
To save presets, it is necessary to ac0cess with administrator (admin) credentials.
4. Link section provides information on the status of the software connection. When LED is green the connection is active, while if it is red, it means that it is not connected.
5. Unit Name section lets you change the name of the unit.

WARRANTY & ENVIRONMENT

PRECAUTIONS

Updates

Ctrl. HW SW

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Configuration

9.7 Admin Mode
To access this mode, you need to go to “Hardware” >”Password” and then type “admin”. This section details the advanced functions that the installer will need to start-up the amplifier, such as:
· X-over · Inputs (Filters, Delay, Limiter, Polarity, Compressor, Gain). · Outputs · Output mode (Low Impedance, Low and High Impedance in Bridge Mode). · Network configuration. · Auto standby configuration. · Boot-Up Mode. · User Rights management. · Firmware update. · Create Flash Image.
For further details on each of these fun0ctions, please see the following chapters.

Admin Mode

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

52

HADA DSP MANAGER & First Steps

9.7.1 X-over
This screen provides a panoramic display of of each HP and LP filter configuration for the different outputs of the amplifier. This will be very useful when using HADA amplifier as a crossover.
This allows the crossover cut filters as well as the possible acoustic alignment delays of the loudspeakers to be displayed graphically on a single screen.
It is also possible to display the 4 outputs levels and manage their respective link, mute, and polarity as well.

PRECAUTIONS

Updates

Ctrl. HW SW

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

DESCRIPTION & FEATURES

9.7.2 Inputs
To manage each of the 4 inputs of the HADA amplifier.

Automatic

Login Main Screen

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

53

HADA DSP MANAGER & First Steps

1. FILTERS Each input has 10 selectable parametric filters. For each filter it is possible to modify its frequency, bandwidth and gain. By default, the bandwidth is indicated as resonance factor Q.
By clicking on the green Q button, the filter width can be expressed as a bandwidth in fractional octave (BW).

PRECAUTIONS

Updates

Ctrl. HW SW

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Each filter can be activated / deactivated by pressing the ON button.

DESCRIPTION & FEATURES

In addition to the 10 parametric filters, a high-pass filter (HPF) and a low-pass filter (LPF) are available for each input. Typologies of these filters are as follows:

Automatic

Login Main Screen

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

It is possible to assign the cut-off 0frequencies to the HPF and LPF filters by typing the frequency value in the text field.
To disable these filters, use the ON0/OFF button or, alternatively, you can write 0 (zero) in the frequency field.
The HPF and LPF filters are the s0ame as those summarised in the X-over chapter.
54

HADA DSP MANAGER & First Steps

Automatic

A Following screen options are available: Full screen. Screenshot to export the filter plots.
Zoom. Textual indications on each filter.

PRECAUTIONS

Updates

Ctrl. HW SW

WARRANTY & ENVIRONMENT

2. DELAY Each input has a delay module. Delay unit’s measurement can be chosen between:

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Configuration

The maximum delay value for the 0inputs is 2s.
3. LIMITER The limiter works on the level of the input signal to the DSP. It is possible to modify the threshold value (by default in dBu) and the reaction times of the limiter as well.
4. POLARITY Phase of the signal can be inverted with the polarity button. When the button is active (blue), 0the phase is inverted.

Admin Mode

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

55

HADA DSP MANAGER & First Steps

Automatic

5. COMPRESSOR

Click on the green

“COMPRESSOR” button, to

display

the

integrated

multiband compressor control

window.

This compressor includes 4 bands, and each band can be configured as follows:

PRECAUTIONS

Updates

Ctrl. HW SW

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

It can operate at different frequency, bandwidth, threshold and with adjustable reaction times. It shows the input signal level and the amount of gain reduction when the compressor is running.
To close the compressor con0figuration window ad return to the programming window, press the green highlighted “Back” button to the right of Compressor.
6. GAIN The Gain fader acts on the gain of the input channel before the matrix mixer and is a replica of the input fader on the Main screen as well as the mute button.
The measurement unit of the input l0imiter follows that of the output limiter and can be selected in the Edit menu of the setup menu.

Configuration

Device

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

56

9.7.3 Outputs
Allows to manage each of the 4 outputs of the HADA amplifier.

Ctrl. HW SW

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

1. MIXER The Mixer section of each output allows you to mix the different inputs before sending them to the amplifier module. By default, each input is assigned to the corresponding output.
2. FILTERS Each output has 10 selectable parametric filters. For each filter it is possible to modify its frequency, bandwidth and gain. By default, the bandwidth is indicated as the resonance factor Q. By clicking on the green Q button, the filter width can be expressed as a bandwidth in fractions of an octave (BW).
Each filter can be activated and deactivated via the ON button.
In addition to the 10 parametric filters, a high-pass filter (HPF) and a low-pass filter (LPF) are available for each input. Typologies for these filters are as follows:
57

Groups TELNET Control

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Ctrl. HW SW
By typing the frequency value in 0the text field, it is possible to assign the cut-off frequencies to the HPF and LPF filters.
To disable these filters, use the 0ON/OFF button or type 0 (zero) in the frequency field instead.
The HPF and LPF filters are the s0ame as those summarised in the X-over chapter. A Following screen options are available:
Full screen. Screenshot to export the filter plots. Zoom. Textual indications on each filter. 3. DELAY Each output has a delay module. Delay measurement unit can be selected between:
The maximum delay value for the0outputs is 2s.
58

Groups TELNET Control

HADA DSP MANAGER & First Steps

4. LIMITER This limiter, unlike the input limiter, allows limiting the level of the signal that will go to the amplifier module. It is possible to modify the threshold value (in dBu) and the limiter reaction times as well.
The most typical application of this limiter is to protect the loudspeakers in case their power is lower than the output power of the amplifier.
The limiter measurement unit can be selected in the Edit menu. The limiter 0
can be configured in a very user-friendly way in relation to the speakers used by using the unit Watt RMS @ 4 Ohm or Watt RMS @ 8 Ohm.
5. POLARITY Phase of the signal can be inverted with the polarity button. When the button is active (blue), 0the phase is inverted.
6. COMPRESSOR Click on the green “COMPRESSOR” button, to display the integrated multiband compressor control window.

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Connection with PC

Updates

Ctrl. HW SW

Automatic

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

This compressor includes 4 bands, and each band can be configured as follows:
It can operate at different frequency, bandwidth, threshold and with adjustable reaction times. It shows the input signal level and the amount of gain reduction when the compressor is running.
To close the compressor con0figuration window ad return to the programming window, press the green highlighted “Back” button to the right of Compressor.
59

HADA DSP MANAGER & First Steps

7. GAIN The Gain fader acts on the gain of the input channel before the matrix mixer and is a replica of the input fader on the Main screen as well as the mute button.
If the user does not set any lim0iter on the output, the scale shall be referenced to the level of the output limiter or the internal limiter (maximum power).

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

9.7.4 Output Mode
It allows you to choose whether the amplifier will work with 4 channels or, if required, it will be possible to configure the first and/or the second channel pair in bridge mode.

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

1. Dual Mode Each channel pair is configured in dual mode by default. This means that each of the 4 channels will work in low impedance. By default, the internal limiters of the amplifier are configured for a load of 4 Ohms. The amplifier module will work correctly with this output load impedance and the limiter will act when the output level is too high.
In case you need to use loads other than 4 Ohm, it is necessary to select the type of load to be used through the routing buttons section above the output faders in the Main menu. In this way, the internal maximum power limiters will be adjusted automatically.
0
60

HADA DSP MANAGER & First Steps

2. Bridge Mode With Bridge mode it is possible to get the sum of the power of two channels in a single output, in low impedance (minimum 8 Ohm) or high impedance (70V and 100V).
In this case, as in Dual Mode, the outp0ut mode of the pair of channels to be used must be configured, through the routing buttons section located above the output faders in the Main menu.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

When a channel pair is configured in0bridge mode, input channels 1 and 3 will act as the source and output faders 1 and 3 will act as the volume control for the bridged pair, as well as the output potentiometers 1 and 3 on the front of the amplifier. The inputs, output faders and potentiometers 2 and 4 will not act on the bridged outputs.

Automatic

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

61

HADA DSP MANAGER & First Steps

9.7.5 Network Settings
Allows you to configure the amplifier’s network interface in DHCP or static mode and to enable or disable third party control as well.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

By default, the amplifier is in DHCP mo0de. So, to make the connection correctly, it is also necessary to configure in the same way the network interface of the computer where the HADA DSP Manager software is installed.
If you need to assign a static IP addres0s, please type the required network parameters in the network configuration menu.

Automatic

Connection with PC

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

62

6 3

Ctrl. HW SW

HADA DSP MANAGER & First Steps

Automatic

Login Main Screen

Device

Updates

Connection with PC

Configuration

Admin Mode

Groups TELNET Control

PRECAUTIONS

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

DESCRIPTION & FEATURES

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

The delay time before the unit goes to standby when no signal is present can be set in minutes or fractions of minutes e.g. 0.5.

9.7.6 Auto Standby
Allows you to configure the automatic standby if no signal is detected at the inputs.

HADA DSP MANAGER & First Steps

9.7.7 Boot-Up Mode
1. Boot-Up Mode Allows you to select the preset the amplifier will start up with.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

By default, the selected option is Last Setting, so the unit will remember the last setting and restart with it.

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Configuration

2. Preset management In admin mode it is possible to fully manage the presets.
In user mode, the end user can load 0the presets of the unit (stored in the amplifier memory) and can only choose from the presets created by the administrator. If user tries to save a preset to the unit or to load/save a local preset, the following message will appear indicating that the user has no sufficient access rights to save presets.

Automatic

Device

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

64

HADA DSP MANAGER & First Steps

In admin mode, allows you to export presets (one at a time) to a local folder on the control PC by using the store buttons, as well as load presets from the PC to the amplifier with the Load button.
The Backup Presets option in the File menu, allows you to make a backup of all presets stored in the unit and later load them into other units with the Restore Presets option.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Connection with PC

PACKAGE CONTENTS

DESCRIPTION & FEATURES

The Restore Presets option executes 0an automatic reset of the unit.
9.7.8 Global Access Rights
In Admin mode, this option allows you to extend or limit the rights of the user mode.

Automatic

Login Main Screen

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

65

9.7.9 Firmware Update
1. Upgrading the amplifier with the firmware included in the software.
Each HADA DSP Manager softwar0e version includes firmware. Updating the firmware of a HADA unit requires logging into administrator mode unless the administrator has previously added the update right to the user.
In the configuration menu, select Hardware and click on Firmware Update.

PRECAUTIONS

Ctrl. HW SW

HADA DSP MANAGER & First Steps

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

A warning message will inform yo0u that a backup of the current preset is required. Otherwise, the current settings will be lost.
Do not switch off the device or u0nplug from the mains during the update process.
2. Updating all amplifiers connected to the network from the main window. If you wish to update all amplifiers co0nnected to the network, the update can be
activated from the main menu, without having to open each individual unit’s configuration window. In the main menu select Tools and click on Enable Update.
66

Groups TELNET Control

Ctrl. HW SW
. By entering the admin mode password, the update button next to each unit discovered on the network, will be activated in orange colour. Then press this button and the process to update the firmware will be the same as indicated in the previous paragraph.
6 7

HADA DSP MANAGER & First Steps

Automatic

Login Main Screen

Device

Updates

Connection with PC

Configuration

Admin Mode

Groups TELNET Control

PRECAUTIONS

WARRANTY & ENVIRONMENT

PACKAGE CONTENTS

DESCRIPTION & FEATURES

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

9.7.10 Create Flash Image
Allows you to create a clone of the unit, concerning configuration, presets, and firmware.
Available in admin mode only. 0
In the configuration menu, select File and click on Create Flash Image to save the desired configuration locally on the control PC.

Ctrl. HW SW

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

By the Flash Image feature, the previou0sly saved configuration can be loaded into another unit.
Please, always observe the correspond0ence of the amplifier models. Loading a picture of a model which does not correspond to the connected model can damage the device and the loudspeaker as well.
68

9.8 Groups
It allows that several amplifiers can be controlled through the same control page. To create a group, from the main screen, select Tools and click on New Group.

Ctrl. HW SW

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Admin Mode

You must then assign a name to each group you create.

Configuration

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Once the group is created, click on

to determine the units that are members of the

group and the functions to be grouped.

69

Groups TELNET Control

HADA DSP MANAGER & First Steps

Select the type of control:
· Carbon Copy: will allow multiple units to be controlled from a single configuration window. · Mute: will allow control of channel mutes only.

Ctrl. HW SW

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Press Select to add more units to the same group.

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

It is possible to add physical units pre0sent on the network, or virtual units to create a group without physical units to add them later.
70

HADA DSP MANAGER & First Steps

Automatic

10. TELNET CONTROL
HADA amplifiers can be controlled by Third-party control systems via Telnet protocol. It is just necessary to use a TCP/IP client terminal by connecting to the IP address of the amplifier on port 23 to send the desired control commands. Commands available are as follows:
· 4 inputs’ volume control Character String: c0i0m1n1v600e<cr><lf> c0 a c3 = IN1 a IN4
Right after the character “v” indicate the absolute value of the volume with two decimals. E.g.: 600=6.00dB; -1200=-12.00dB
· 4 outputs’ volume control Character String: c128i0m1n1v600e<cr><lf> c128 a c131 = OUT1 a OUT4
Right after the character “v” indicate the absolute value of the volume with two decimals. E.g.: 600=6.00dB; -1200=-12.00dB
· Mute/Unmute Character String: c0i0m2n2v1e<cr><lf> c0 a c3 = IN1 a IN4 c128 a c131 = OUT1 a OUT4 v1=Mute v0=Unmute
· Preset Recall Preset selection character string: c0i0m4n4v2e<cr><lf>
Right after the character “v” indicate the preset number
Preset execution character string: m3n3i1e<cr><lf>
After executing the preset, it will be ac0tive. The graph in HADA DSP Managers (e.g. in case of volume change) will not be updated in real time but will be updated with the next connection to the software.

DESCRIPTION & FEATURES

PACKAGE CONTENTS

WARRANTY & ENVIRONMENT

PRECAUTIONS

Configuration

Connection with PC

Updates

Ctrl. HW SW

Admin Mode

Login Main Screen

Device

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Groups TELNET Control

71

HADA DSP MANAGER & First Steps

PRECAUTIONS

Updates

WARRANTY & ENVIRONMENT

Automatic

Connection with PC

PACKAGE CONTENTS

Login Main Screen

DESCRIPTION & FEATURES

Device

Configuration

Admin Mode

PANEL FUNCTIONS INSTALL & CONNECT START-UP & OPERATION TECHNICAL DATA

Ctrl. HW SW
All product characteristics are subject to variation due to production tolerances. NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications. For technical queries contact your supplier, distributor or complete the contact form on our website, in Support / Technical requests.
72 Motors, 166-168 | 08038 Barcelona, Spain | Tel. (+34) 932238403 | information@ecler.com | www.ecler.com

Documents / Resources

ecler HADA Series Networkable Amplifiers [pdf] User Manual
HADA Series Networkable Amplifiers, HADA Series, Networkable Amplifiers, Amplifiers

References

Leave a comment

Your email address will not be published. Required fields are marked *