EBYTE E860-DTU Wireless Remote Synchronization Switch User Manual

EBYTE-logo

EBYTE E860-DTU Wireless Remote Synchronization Switch

EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch-product

Disclaimer

  • EBYTE reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited.
  • The information contained herein is provided “as is” and EBYTE assumes no liability for the use of the information. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by EBYTE at any time. For most recent documents, visit www.ebyte.com

 Overview

Introduction

EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (2)

The Wireless Remote Synchronous Switch is an end-user device that uses LoRa modulation technology to enable wireless transmission of digital signals over long distances. It supports the acquisition of digital inputs (DI) and the control of relay outputs (DO). Its core functionality is to enable remote synchronous control without the need for wiring, offering high ease of use and allowing users to quickly integrate it into their own systems. The power supply voltage is 8–28 V DC.

Features

  • Utilizes the latest LoRa technology (with a built-in wireless module), supporting wireless signal transmission and control;
  • Supports models with 1- or 2-channel relay outputs (optional);
  • Supports 1 or 2 input channels (optional), with dry contacts as the default;
  • Supports a maximum transmission range of 10 km (optional);
  • Supports one-to-one and one-to-many modes;
  • Supports network outage recovery; if the outage duration exceeds a set threshold, the receiver’s output can be reset;
  • Supports encrypted transmission to prevent interference between devices in the network;
  • Multiple indicator lights display operating status;
  • Pairing and real-time control via buttons—simple and fast;
  • Features restart and factory reset buttons to handle various emergencies;
  • Constructed with a flame-retardant plastic housing for safety and reliability;
  • Power supply: DC 8–28 V;
  • Multiple protection features, including reverse polarity protection, overcurrent protection, and overvoltage protection;
  • Supports standard 35mm DIN rail mounting and mounting via positioning holes for convenient and efficient installation;
  • Supports software watchdog for more stable and reliable device operation;
  • Operating temperature: Industrial-grade range, -40 to 85 degrees Celsius;
  • Ambient humidity: 5%–95% non-condensing

 Technical Specifications

Specifications and Parameters

Category Name Parameters
Power Supply Operating Voltage DC 8–28 V
Power Indicator Blue LED indicator
Wireless Parameters Operating Frequency Band 410.125–493.125 MHz / 850.125–930.125 MHz
Transmit Power 22 dBm / 30 dBm (selectable)
Receive Sensitivity -148 dBm@2.4Kbps
Transmission Range 22 dBm: 5 km; 30 dBm: 10 km (clear, open environment; maximum power; antenna gain 5 dBi; height 2 m)
Airspeed 2.4K
Antenna Options SMA antenna connector (external thread, internal bore)
Response Time Response Time Within 300 ms
DI Input DI Channels 1/2-channel (optional)
Input Type Dry contact/NPN type
Input Indicator Green LED indicator
DO Output Number of DO

Channels

1/2 channels (optional)
DO Output Type 1 DO output: Type A relay / 2 DO outputs: Type C relays
DO Output Mode Momentary mode
Relay Contact

Rating

10 A at 30 VDC, 10 A at 250 VAC
Output Indication Green LED indicator
Power Consumption Transmit Current Draw 290mA @ DC 12V
Average Current Draw 70mA @ DC 12V
Current Draw of the Relay Along the Line 15mA @ DC 12V
Other Product Dimensions
  • E860-DTU(1010-400SL22)-S: 92*54*32mm ( Length × Width × Height)
  • E860-DTU(2020-400SL22)-S:100*90*40mm(Length × Width × Height)
  • E860-DTU(1010-400SL30)-S: 92*54*32mm ( Length × Width × Height)
  • E860-DTU(2020-400SL30)-S:100*90*40mm(Length × Width × Height)
  • E860-DTU(1010-900SL22)-S: 92*54*32mm ( Length × Width × Height)
  • E860-DTU(2020-900SL22)-S:100*90*40mm(Length × Width × Height)
  • E860-DTU(1010-900SL30)-S: 92*54*32mm ( Length × Width × Height)
  • E860-DTU(2020-900SL30)-S:100*90*40mm(Length × Width × Height)
Product Weight E860-DTU(1010-400SL22)-S:72g E860-DTU(2020-400SL22)-S:120g E860-DTU(1010-400SL30)-S:75g E860-DTU(2020-400SL30)-S:123g E860-DTU(1010-900SL22)-S:72g E860-DTU(2020-900SL22)-S:120g E860-DTU(1010-900SL30)-S:75g

E860-DTU(2020-900SL30)-S:123g

Operating -40~+85℃、5%~95%RH(No  condensation)

Mechanical Dimension Drawings

EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (3)

EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (4)

Here, we will use the E860-DTU (2020-400SL22)-S and the E860-DTU (1010-400SL22)-S as examples.

Port Description EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (5)

No E860-DTU(1010-X00SLXX)-S Device Port Descriptions E860-DTU(2020-X00SLXX)-S Device Port Descriptions
1 SMA Antenna Connector 8–28 V DC (V-)
2 8–28 V DC (V-) 8–28 V DC (V+)
3 8–28 V DC (V+) Digital Input Common Terminal
4 Relay Output: Normally Closed Contact 1 Digital Input Port 1
5 Relay Output Common Terminal Digital Input Common Terminal
6 Digital Input Common Terminal Digital Input Port 2
7 Digital Input Common Terminal AWS Antenna Interface
8 STATE Button Relay Output Normally Open Port 1
9   Relay Output Common Terminal
10   Relay Output Normally Closed

Terminal 1

11   Relay Output Normally Open Terminal 2
12   Relay Output Common Terminal
13   Relay Output Normally Open Terminal 2

LED Indicators and Button Descriptions

Indicator Light LED Indicator Light Colors Note
DC Red LED Power indicator light: stays on when the power is on and turns off when the power is off.
STATE/LINK Blue LED/Orange LED
  1. Press and hold for 2 seconds to enter pairing mode;
  2.  Press and hold for 6 seconds or longer to restore factory settings;
  3. Press and hold continuously to cycle through pairing mode and reset mode;
  4. While in configuration mode, press briefly to exit configuration mode;
  5. One-to-many (including one-to-one) – bidirectional (when devices share the same number of channels): As long as one slave device successfully connects to the master, the master’s LINK indicator remains steady; after a slave device successfully connects to the master, the slave’s LINK indicator remains steady;
  6. One-to-many – bidirectional (with different numbers of channels, where each channel on the master is independently controlled by a slave): The number of connected devices determines how many times the host’s LINK indicator flashes (cycle: 300 ms; after the flash cycle completes, the light turns off for 1 second, then begins flashing again). For example: If two devices are connected, the LINK indicator flashes twice per cycle, then turns off for 1 second before resuming the flash cycle;

Detailed Explanation of Features

Operating Modes
This series offers three operating modes, as shown in the table below. When using this series of products, the system automatically selects the appropriate operating mode based on the user’s usage. Each time you switch to a different pairing mode, you must reset the device to factory settings before proceeding.

One-on-one, bidirectional control EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (6)
One-to-Many—bidirectional control:

When any slave is activated, the master is controlled.

EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (7)
One-to-Many—bidirectional control(Different Number of Channels) Configuration: One master with 2 channels can be paired with two slave devices, each with 1 channel; the master’s DI1 controls the slave device’s DO1.

One-on-One, Bidirectional Work Model

  1. For example, prepare two E860-DTU (1010-400SL22)-S units, two power supplies with a 12V DC output, and two antennas, then connect the power supplies as shown in the figure below,EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (8)
  2.  At this point, designate one of the devices as the host. Press and hold the STATE button for 2 seconds to enter configuration mode; the STATE indicator will flash. Next, press and hold the STATE button on the other device for 2 seconds; once the STATE indicator flashes, it indicates that the device has entered configuration mode. The two devices will then automatically pair to complete the pairing process. Now, briefly press the STATE button once to exit configuration mode. The device that entered pairing mode first is the master; its LINK and STATE lights will remain steady. After the slave is successfully paired, its LINK light will remain steady and its STATE light will flash. As shown in the figure below, 2-1 is the master and 2-2 is the slave. EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (9)Figure 3-2-2: After Successful Pairing of Host and Slave
  3. At this point, DI1 on module 2-1 can control DO1 on module 2-2, and DI1 on module 2-2 can control DO1 on module 2-1, as shown in the figure below.
    EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (10)
  4. Channel Synchronous Switch: This mode operates on the same principle and will not be demonstrated here. DI and DO can be connected to the appropriate control system according to the user’s selection for operation.

 One-to-Many Bidirectional Control

  1. This mode supports up to 1 master and 200 slaves. When a DI signal is input to any slave, the master is controlled; the first device to enter pairing mode becomes the master. The master’s DI can control the DO of all slaves.
  2.  Prepare two E860-DTU (2020-900SL22)-S units, two E860-DTU (2020-900SL30)-V2 units, three 12V DC power supplies, and three antennas, then connect them to power.
  3. Here, we will use the E860-DTU (2020-900SL22)-S as the master unit, hereinafter referred to as 2-1. The two slave units are the E860-DTU (2020-900SL30)-S and the E860-DTU (2020-900SL22)-S, referred to as 2-2 and 2-3, respectively. Press and hold the STATE button on 2-1 for 2 seconds to enter configuration mode; the STATE indicator light will flash. Next, press and hold the STATE button on 2-2 for 2 seconds; once the STATE indicator light flashes, it indicates that configuration mode has been entered. At this point, the two devices will automatically pair, completing the pairing process. Next, briefly press the STATE button on unit 2-2 to exit configuration mode. This completes the pairing between units 2-1 and 2-2. Next, put unit 2-3 into pairing mode; units 2-1 and 2-3 will then automatically pair. Afterward, briefly press the STATE button on each unit to exit pairing mode. This completes the one-to-many pairing for devices with the same channel number, where 2-1 is the master and 2-2 and 2-3 are the slaves, as shown in Figure 3-3-1 below. At this point, the STATE indicator lights on 2-2 and 2-3 will flash, indicating they are slaves, while the STATE indicator light on 2-1 will remain steady, indicating it is the master.EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (11)

EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (12)

Figure 3-3-2: Host digital input DI1 controls the digital output DO1 of two slave devices EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (13)

One-to-Many Bidirectional Control (Different Channel Counts)

  1. Configuration: For example, if the master is a 2-channel synchronous switch, it can be paired with two 1-channel slaves. The DI and DO channel indicator lights correspond to different slaves; for instance, if Slave 1 has 2 channels, then the master’s DI1, DI2, DO1, and DO2 correspond to Slave 1.
    Note: The total number of channels across all slaves must not exceed the number of channels on the master.
  2. In this example, one E860-DTU (2020-400SL30)-S, referred to as 2-1, serves as the master, and two E860-DTU (1010-400SL22)-S units, referred to as 1-1, 1-2 as Slave 1 and Slave 2, respectively. After a successful connection, the master’s yellow LINK indicator will flash in a pattern of two on, one off. Two flashes of the yellow light indicate that two slaves are connected. Once the slaves are successfully connected in the correct order, the digital I/O mapping is complete. At this point, the correspondence between the master’s DI and the slave’s DO is as shown in the table below: 3.
Host Slave
DI1 on 2-1 Slave 1: DO1 at 1-1
DI2 on 2-1 Slave 2: DO2 at 1-2

Pairs of digital I/O between the master and slave under various one-to-many bidirectional configurations with different numbers of channels

EBYTE-E860-DTU-Wireless-Remote-Synchronization-Switch- (1)

Revision history

Versions Revision Date Revision Notes Maintaining people
1.0 2026-06-29 Initial Version  ZT

About us

Documents / Resources

PDF thumbnailE860-DTU Wireless Remote Synchronization Switch
User Manual · EBYTE, Chengdu Ebyte Electronic Technology Co. Ltd., E860-DTU x0x0-x00SLxx -S, E860-DTU 1010-400SL22 -S, E860-DTU 2020-400SL22 -S, E860-DTU 1010-400SL30 -S, E860-DTU 2020-400SL30 -S, E860-DTU 1010-900SL22 -S, E860-DTU 2020-900SL22 -S, E860-DTU 1010-900SL30 -S, E860-DTU 2020-900SL30 -S, E860-DTU, wireless switch, LoRa remote control

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.